Loading...
Specifications (53) 30302oiG — ooa37 /&58 g'd 5 VI/ -rte A I/6 Project: CWS Durham AB -4 Baffle Walls • 16580 SW 85 Avenue .00 PROFe Tigard, OR 97224 „c , NG' NE-4 • Longitude: - 122.76458 °, Latitude: 45.40078° •�� �/I //r -- Client: West Yost & Associates • ' GO 8100 SW Nyberg St, St 400 g 20 0` q_ �o Tualatin, OR 97062 ' LIAM P� EXPIRES 12/31 /1 THESE CALCULATIONS HAVE BEEN SUBMITTED ELECTRONICALLY. RECORD COPIES ARE ON FILE WITH THE ENGINEER OF RECORD. Structural Calculations Scope: To provide structural calculations for the proposed baffle walls at the above referenced location. The baffle wall is designed for seismic loads for when the basin is empty only. Elements not specifically referenced in these calculations are outside the purview of these calculations and are designed by others References: 1. 2010 Oregon Structural Specialty Code (OSSC) 2. 2009 International Building Code (IBC) 3. SEUASCE 7 -05, Second Edition, Minimum Design Loads for Buildings and Other Structures, American Society of Civil Engineers 4. Steel Construction Manual, American Institute of Steel Construction (AISC), 13 • Edition. 5. ACI 318 -08, Building Code Requirements for Structural Concrete, American Concrete Institute 6. Roark's Formula's for Stress & Strain, 6 Edition Table of Contents Scope & References 1 Table of Contents 1 Design Criteria 2 Wall Sketch 3 Lateral Load Determination 4 Wall Design, Seismic on Empty Tank 6 Wall Analysis, Gravity 11 Concrete Infill Analysis 12 /\Revision — 12/15/2010 Revise to Category III structure, I 1.25, Iw =1.15 File: Pse \09- 182 -03 MSC Peterson Structural Engineers, Inc. project e22, date I (� 12 f �, Q 6 5319 S.W. Westgate Drive, Suite 215 1 ) Portland, Oregon 97221 -2411 Phone (503) 292 - 1635 designer sheet I of 1 Fax: (503) 292 -9646 041 • Design Criteria: • Concrete f c= 4,000 psi, Fy=60 ksi Soil SB 1,500 PSF (net) SB 1,500 +y,v(21.87') = 2,865 PSF (gross) SBau - secs= SBau(l .33) =3,810 PSF (seismic, empty) Design Loads: Wind: ASCE 7 -05 95 mph, exp. B Seismic: From USGS Earthquake Ground Motion Parameters S5 92.6 % g S( =33.4 % g Site Class 12-/6/2.10 MSC Peterson Structural Engineers, Inc. project C .' Cl - ' �, date 5319 S.W. Westgate Drive, Suite 215 1J C,i Portland, Oregon 97221-2411 _ 1. Phone (503)292-1635 designer I_ (,; f-� sheet Fav (503) 292 -9846 1 � - of t EL 162.00 CELL 6 C -LL 5 20 -OD EL 142,00 n5IN Peterson Slruclunsl Englneera, Inc. 5719 S.W. Westgate Drive, Sults 215 project ./( �., date Portland, Oregon 97221.2411 �' I O / ry uJ /-)-0 . Phone (507) 292 -1675 designer �' „4 sheet 1 Fax. (507) 292 -9946 of 5A5(IN -1 _ e LoA 1.) 93.75 _ • _ ... (... .--.. ,.-4 --1 ._"... .....' • - • 7 -- - -/-_, 1; ---• -,--- 0 ( p (..:' ) — :--- 0. ter,c/ = e----- c c2IN,YT t•?._() L. C .4.,, = c„? ,5 R. 5 )./... , .=_. (..) • ovo rz -`-' (../.'„, W 7:" (. 0 2)( I 0 . 't:I.r.)(11 ..:. ) .7. 43, , . ..., , F i . 'v --' (43.6 v( (D.-c; ') --e----w---- 1 -A0 tAT M :: V C*. ) = (07(0 rty)(?... ) wt-ip 1_4 C-f. 4 ( ,,\• 1 o-5 I ezi 62 27 j FT< -, Es7 , k-M011\1e-r- • ■-v4-1.4_.$) ., s 0 . 060_5 („K z KA,V 1 4 11 )2. KZt:"1'6) ob L – Q, P..5F - Nci.. 7 - 0.eh - 1 A , ..,. ;,:., 0 !.) i : .,- -21 0 4.41 f4 ' 't t i I ' r i / Vb 1 f4 — F ---' (.a I 1 et:' y It.' sy.2_0c } , 4 r F- e 4 ,EL v-4.A kL, • - ‘,.. 4: _ ,.....i--/ 'i - ., 97221.2411 project - date 1 5797971:. e E'' 9n71; inc 1 Portland Oregon Phone (503) 292.1635 Fax: (503) n2-9846 designer 01 1 b`L r ,,:-, , I ... k....„ . IV tstze a 0 i 0 i.). 1.:L..„. c., t . , sheet d ' of I • sliAr c ot-.; . 7 FE R 126A ro m (.4 LA t:ok. - • • 5".„ I.! I.: ) dx) - to 4 ( 2 ' .3b R;F Fz,EsoLvE, tt..11 A tato E 0T ) )( ) R - 11 1] 43+6 I gn _ lb ' • • „ 1\1= et - , 840. 1) - 561/ ib f WALL P.?) AS _ 4-7 " 1 a 0 • ca41 ti — 0. 1 <0 37.5 -res.Nf NI 601`4 6.1 ID" r 4( .S5f c l 10 a.--X6 22 ) = ,1 ffj (40W tX)(04.0=4-1)).(t0' - = 7 .1;1,893 16 —7: I9 1'7S / 4 _ Of ok A 12./ I _zis Peterson Structural Engineers, Inc. 5319 S W. Westgate Drive, Suite 215 Portland, Oregon 97221-2911 PhOne (503) 292.1635 project () (.1 I 62 0 designer 1: i 1 date ( sheet of Fax: (503) 292-91346 ►''i ' 1..� 1_.�j 12 a `" /EiJtr RED s \\\\ Palercon uClurel Englne Inc. J SJ9 S.W. W Drlv e, SW(e 2!5 project /� r , l date Portland, Ore gon 97221 -2011 (� ( f� J f._ +�- Phone (503) 292 -1635 designer r Sheet (^ of Fax: 1503) 292 -9946 -, L'( j._` U . www.hilti.us PROFIS Anchor 2.0.7 • Company: Peterson Structural Engineers Page: - 1 Specifier: Elias Hahn Project: CWS Durham Address: Sub - Project I Pos. No.: AB4 Baffle Wall Anchor Phone I Fax: - I - Date: 12/15/2010 E -Mail: Specifier's comments: 1. Input data Anchor type and diameter: HIT -RE 500-SD + Rebar A 615 Gr:60, #6 Effective embedment depth: h, = 10.395 in. = 15.000 in.) •-main ABOSIMSENIfifffiffilatida Material: ASTM A 615 Gr.60 Evaluation Service Report:: ESR 2322 �R.AE oo-so Issued I Valid: 11/01/20071 - Proof: design method ACI 318 / AC308 Stand -off installation: e, = 0.000 in. (no stand -off); I = 0.500 in. Anchor plate: Custom; f = 35998 psi; I, x l x t = 12.000 x 24.000 x 0.500 in. (Recommended plate thickness: not calculated) Profile no profile Base material: cracked concrete , 4000, f, = 4000 psi; h = 24.000 in., Temp. short/long: 32/32 F Installation: hammer drilled hole, installation condition: dry Reinforcement: condition A; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Geometry [in.] y Z x I�r *NM t= 0.500 o° h,,= 10.395 El _ o ° x h = 24.000 ,_ I re Loading (Ib, FtLb] Governing loads Governing loads (Load case 1) N =0 VP =0 0 M 0.000 M1.= 17520.000 V, 1752 Z V 0 9 M. 0.000 v M 17520.000 M 0.000 x Eccentricity (structural section) [in.] e, = 0.000; e, = 0.000 Seismic loads (cracked concrete assumed; categories C, D, E, or F): no V, = 1752 M, = 0.000 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor (c ) 2003 -2009 Hilti AG, FL -9494 Schaan Milk is a registered Trademark of Hilti AG, Schaan 1- 1 1 www.hilti.us PROFIS Anchor 2.0.7 Company: Peterson Structural Engineers Page: 2 _ Specifier: Elias Hahn Project: CWS Durham Address: Sub - Project I Pos. No.: AB4 Baffle Wall Anchor Phone I Fax: - I - Date: 12/15/2010 E -Mail: 2. Load case /Resulting anchor forces Load case (governing): Anchor reactions [Ib] Tension force: ( +Tension, - Compression) Anchor Tension force Shear force Shear force x Shear force y it 1 10834 438 438 0 A y 2 0 438 438 0 3 11708 438 438 0 4 705 438 438 0 > Tension Compression max. concrete compressive strain [ 1: 0.29 Ef 0 max. concrete compressive stress [psi]: 1252 � ' resulting tension force in (x/y) =(- 3.740/ - 2.402) [lb]: 23245 resulting compression force in (x/y)= (5.304/- 2.411) [lb]: 23245 4 3. Tension load Proof Load N. [Ib] Capacity i N,, [Ib] Utilization ]i„ [ %] = NJ¢N„ Status Steel Strength* 11708 29700 39 OK " Bond Strength* 23247 23404. 99 OK Concrete Breakout Strength ** 23247 29675 78 OK " most unfavorable anchor * *anchor group (anchors in tension) Steel Strength N. [Ib] 4, +N.. [Ib] N,.. [Ib] 39600 0.750 29700 11708 Bond Strength A. [ ] A „r, [in I so.„. [in.] cn. „. [in.] c [in.] c. [in.] 737.86 320.44 17.901 8.950 393.701 15.591 k..a 2 e.,,w,25e0 [p Kt., .r„ [psi] x, ,, [psi] W „.o P WB „ . 17 2065 1.00 1000 1471 1.322 1.121 e.,.„ [in.] W..,.„. a ,,„ [in.] W.c2. 146 W, „. 4 ad 2.424 0.787 3.411 0.724 1.000 1.000 N. [Ib] 4, 4tN. [Ib] N. [Ib] 24491 0.650 23404 23247 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003 -2009 Hits AG, FL -9494 Schaan Rib is a registered Trademark of HO AG, Schaan U • • • ILTI - www.hilti.us PROFIS Anchor 2.0.7 Company: Peterson Structural Engineers Page: 3 - Specifier. Elias Hahn Project: CWS Durham Address: Sub - Project I Pos. No.: AB4 Baffle Wall Anchor Phone I Fax: - I - Date: 12/15/2010 E -Mail: Concrete Breakout Strength A. [in ] A [in ] c [in.] c [in.] 1735.07 972.33 393.701 15.591 eeu [in.] Wwl,N e aN [in.] W.rz.N INN WON kn 2.424 0.865 3.411 0.821 1.000 1.000 17.000 N, (lb] 4, $N nb) N. [lb] 36029 0.650 29675 23247 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor (b ) 2003.2009 Hilti AG, F1 -9494 Schwan Hilt is a registered Trademark ot Hilll AG, Schwan - - www.hilti.us PROFIS Anchor 2.0.7 Company: Peterson Structural Engineers Page: 4 - Specifier: Elias Hahn Project: CWS Durham Address: . Sub - Project I Pos. No.: AB4 Baffle Wall Anchor Phone I Fax: - I - Date: 12/15/2010 E -Mail: 4. Shear load Proof Load V.. [Ib] Capacity 4tV, [Ib] Utilization 13,,1%) = V,./0V, Status Steel Strength' 438 15444 3 OK Steel failure (with lever arm)* N/A N/A N/A N/A Pryout Strength** 1752 94989 2 OK Concrete edge failure in direction" N/A N/A N/A N/A • most unfavorable anchor "'anchor group (relevant anchors) Steel Strength V. [lb] (IV„ [Ib] V. [Ib] 23760 0.650 15444 438 Pryout Strength (concrete breakout relevant) AN. [in ] A [in ] c kq, 1831.07 972,33 - 2.000 ec,,0 [in.] W.,,,N ecv.v [in.] Wsx.N W...N W,,.N ko 0.000 1.000 0.000 1.000 1.000 1.000 17.000 N, [lb] 4) 0V„, [Ib] V. [Ib] 36029 0.700 94989 1752 5. Combined tension and shear loads ON = N /0N, p, = Vu /4V, Utilization p „„ [%] Status 0.993 0.028 - 85 OK pNV =(pN + pV)/ 1 .2 < =1 6. Allowable Stress Design (Refer to ICC -ES Evaluation Service Report) single anchor relevant (tension); relevant to a single anchor (shear) Tension [Ib] Shear [Ib] including excluding including excluding Reference for load seismic seismic seismic seismic ACI318 Section D.4.4 - 23404 - 15444 ACl318 Section D.4.5 - 11702 - 7722 R = R. / a TfT,„• + VA/„.,,,,,,, <= 1.2 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor (c ) 2003 -2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan l0 uIl n.rr u 1 - www.hilti.us PROFIS Anchor 2.0.7 Company: Peterson Structural Engineers Page: 5 - Specifier: Elias Hahn Project: CWS Durham Address: Sub- Project I Pos. No.: AB4 Baffle Wall Anchor Phone I Fax: - I - Date: 12/15/2010 E -Mail: 7. Warnings Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. Although the user chose Condition A the calculation was performed for Condition B. Condition B applies where supplementary reinforcement is not provided, or where pullout or pryout strength governs! Design Strengths of adhesive anchor systems are influenced by the cleaning method. Refer to the INSTRUCTIONS FOR USE given in the Evaluation Service Report for cleaning and installation instructions The present version of the software does not account for special design provisions for overhead applications. Refer to related approval (e.g. section 4.1.1 of the ICC -ESR 2322) for details. IBC 2006, Section 1908.1.16, requires that the governing design strength of an anchor or group of anchors be limited by ductile steel failure, if this is NOT the case, ACI 318 -D Section D.3.3.5 requires that the attachment that the anchor is connecting to the structure shall be designed so that the attachment will undergo ductile yielding at a load level corresponding to anchor forces no greater than the design strength of anchors specified in ACI 318 -D section D.3.3.3, or the minimum design strength of the anchors shall be at least 2.5 times the factored forces transmitted by the attachment. Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI318 or the relevant standard! The anchor plate is assumed to be sufficiently stiff in order to be not deformed when subjected to the actions! Fastening meets the design criteria! Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003 -2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan i ` • 104116119 www.hilti.us PROFIS Anchor 2.0.7 Company: Peterson Structural Engineers Page: 6 Specifier: Elias Hahn Project. CWS Durham Address: Sub - Project I Pos. No.: AB4 Baffle Wall Anchor Phone I Fax: - I - Date: 12/15/2010 E -Mail: 8. Installation data Anchor plate, steel: Custom; f = 35998 psi Anchor type and diameter: HIT -RE 500 -S13 + Rebar A 615 Gr.60, #6 Profile: no profile Installation torque: 0.000 FtLb Hole diameter in the fixture: d, = 0.750 in. Hole diameter in the base material: 0.875 in. Plate thickness (input): 0.500 in. Hole depth in the base material: 10.395 in. Recommended plate thickness: not calculated Minimum thickness of the base material: 12.145 in. n y 0 0 O 4 0 0 0 0 0 3 x 0 2 0 0 0 0 (\i 0 o' 1 0 0 (6 .000) 2.000) 6.0000 6.0000 Coordinates Anchor [in.] Anchor x y c„ c„ • 1 -4.000 -9.000 - - - 2 4.000 -3.000 - - - - 3 -4.000 3.000 - - - - 4 4.000 9.000 - - - - Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003 -2009 Hi15 AG, FL -9494 Schaan HIIU is a registered Trademark of Hilti AG, Schaan 1 6 2. • A i•C:t !_ `SAL ".:) w4 I.. d I 50 P d i P ' • 'i } y L. v..1 x - d Peterson Structural Engineer', Inc sue° 9 6 5319 S.W. Westgate Drive, Suite 215 :::: Portland, Oregon 97221 -2ss 5 Cf PAOne (503) 292.1 t{35 Fes: (503) 292.9848 r sheet a) of Cor..\c.gV -r E 014. it-4 FImay- I I i R (� II � I 1 EL. 165.0' 1 i 1 ,.. .- 4 • . ;.-, . -t I �� � EL. 155.0' A L - W'__ vv4.4.1,-oef;KtoY5) ., i •i.• .• -. .. 1 ..• .. .: 1 fb//f I - ' ` �� ) e , 11! I rf a) _- c u✓ P 1 it, /. I I C) :e . II. 1 I i , k 7r 1.:( o.. I ° 1 l' • I I ea I HECK MOMi -N`T f• }r_ I I� ° ° CHECK - t� 1l . • 1 ' � EL 1--- I 4:2: a. e " e e • ` ° e f as ° e ___ u °°___�,__ • I 0 1L 2.C.4 TUE Peterson Structural Engineers, Inc. 5319 S.W. Westgate Drive, Suite 215 project D (;i ' dell=, Portland, Oregon 97221 -2a11 1 L i t- • • ( r'` "'I ^ '^' i �� Phony (503) 292.1635 g )Of sheet Fax: (50 3) 292 -9846 designer 1 ,,tt I.54 4 I W-ry (7( S '..) ( 1=5 pc /3107:5 C ) ot..1 F n-F : MOME1\17 1 '4 :7 ( (ep 7 , 7 F / k I 4 et 2" P s 4 16 - , • __ _ NOTE X4 4s-v , IA RES 91 e m o v-krr TAAP_. -ro 11/15/.2_010 Peterson Structural Engineers, Inc. 5319 S.W. Westgate Drive, Salle 215 Portland, Oregon 97221.2411 Phone (503) 292-1635 Fax: (503) 292-9546 project . date j ;_c: designer r - r :■ t I 10 / sheet (•";'' ') of Peterson Structural Engineers, Inc. Title : CWS DURHAM - A84 IMPROVEMENTS Job # 09 -182 nun 5319 Sd, Westgate Drive, Suite 215 c EGH • Portland, Oregon 97221 Pro Projeect Desc.: Pc erscn s„"et, el &einem. Inc _ Phone: 503.292.1635 Project Notes : Fax: 503.292.9846 . www.psengineers.com hinted 15 DEC 2010. 501AM Concrete Beam Design File: G :,Pro)ectFlles,2009109- 176to09- 200109 -1821 Enercalc109- 182 -01.ec6 ENERCALC, INC. 1983-2009, Ver.. 6.1.00 Lic #': KW r. „w. .- .. ,.. 1L aense1O neY Peterson structural engineers Description : Check Existing Concrete Stem Material Properties Calculations per IBC 2006, CBC 2007, ACI 318 -05 fc i = 4.0 ksi 4 Phi Values Flexure : 0.90 fr = fc * 7.50 = 474.34 psi Shear : 0.750 y! Density = 145.0 pcf 131 = 0.850 Elastic Modulus = 3,605.0 ksi Load Combination 2006 IBC & ASCE 7 -05 Fy - Main Rebar = 60.0 ksi Fy - Stirrups = 40.0 ksi " E - Main Rebar = 29,000.0 ksi E - Stirrups = 29,000.0 ksi Stirrup Bar Size # # 3 Num of Bars Crossing Incl Crack = 2 I I 12 In E(3 26) i - - . S 12 "wx24 "h -_ -- Span =23.0 ft _Cross Section & Reinforcing Details Rectangular Section, Width = 12.0 in, Height = 24.0 in Span #1 Reinforcing.... 147 at 3,0 in from Bottom, from 0.0 to 23.0 ft in this span 147 at 3.0 in from Top, from 0.0 to 23.0 ft in this span ' Applied Loads Service loads entered. Load Factors will be applied for calculations, Load for Span Number 1 Point Load : E = 3.526 k (a, 17.250 fl DESIGN SUMMARY Design N.G. Maximum Bending Stress Ratio = 1.023: 1 Maximum Deflection Section used for this span Typical Section Max Downward L +Lr +S Deflection 0.000 in Ratio = 0 <360 Mu : Applied - 60.824 k -ft Max Upward L +Lr +S Deflection 0.000 in Ratio = 0 <360 Mn ' Phi : Allowable 59.450 k -ft Max Downward Total Deflection 0.438 in Ratio = 1258 Load Combination +1.20D+0.50L+0.20S+E Max Upward Total Deflection 0.000 in Ratio = 999 <180 Location of maximum on span 0.000ft Span # where maximum occurs Span # 1 Vertical Reactions - Unfactored Support notation : Far left is #1 Load Combination Support 1 Support 2 Overall MAXimum 3.526 D+E 3.526 Shear Stirrup Requirements No Stirrups Required from 0.00 to 23.00 ft along span, Condition : Vu < PhiVc/2 Maximum Forces & Stresses for Load Combinations Load Combination Location (ft) Bending Stress Results (k -ft ) Segment Length Span # in Span Mu : Max Phi'Mnx Stress Ratio MAXimum BENDING Envelope Span # 1 1 -60.82 59.45 1.02 +1.20D+0.50L+0.20S+E Span # 1 1 -60.82 59.45 1.02 +0.90D+E +1.60H Span # 1 1 -60.82 59.45 1.02 / ' ` 1211W2-4= i o Overall Maximum Deflections - Unfactored Loads Load Combination Span Max. "= Dell Location in Span Load Combination Max. " +" De0 Location in Span D+E 1 0.4384 23.000 0.0000 0.000 D`1 '/b7- 10(2-q/-ora f6,-14 I G of j o