Plans
LABELS ELECTRICAL NOTES GENERAL NOTES LEGEND ABBREVIATIONS WARNING! ELECTRIC SHOCK HAZARD! 1. WHERE ALL TERMINALS OF THE 1. THIS SYSTEM IS GRID- INTERTIED VIA A UL- LISTED O (E) UTILITY METER A AMPERE RECEIVE 1 DISCONNECTING MEANS MAY BE ENERGIZED POWER - CONDITIONING INVERTER. AC ALTERNATING CURRENT RECEI Y G ( +) "" � IN THE OPEN POSITION, A SIGN WILL BE 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. PROVIDED WARNING OF THE HAZARDS PER 3. ALL INVERTERS AND ARRAYS ARE NEGATIVELY GROUNDED. ® GRID -TIED INVERTER BLDG BUILDING ='''- CONC CONCRETE FEB 18 2011 --- SolarCit . ART. 690.17. 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED. Dc C COMBINER BOX 2. EACH UNGROUNDED CONDUCTOR OF THE 5. ALL WORK TO BE DONE TO THE CURRENT UBC. DC DISCONNECT D DISTRIBUTION PANEL ARNINGI ELECTRIC SHOCK HARD! MULTIWIRE BRANCH CIRCUIT WILL BE 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE CURRENT I-'-1 AC DISCONNECT CITY OF TIG/1RD HAZARD! OPERATING VOLTAGE V IDENTIFIED BY PHASE AND SYSTEM PER NATIONAL ELECTRIC CODE AS AMENDED BY THE OREGON A C EPT C URRENT ii❑❑�rr IVISII EGC EQUIPMENT GROUNDING 2 MAXIMU URRENT M OPERATING A ART. 210.5. 3, A NATIONALLY- RECOGNIZED TESTING ELECTRICAL SPECIALTY CODE. c COMBINER BOX (E) EXISTING C LABORATORY SHALL LIST ALL EQUIPMENT IN EMT ELECTRICAL METALLIC TUBING " "al =�- _• G SOLAR GUARD METER s ` SoIarblt ..,;: wRU 0. COMPLIANCE WITH ART. 110.3. O DISTRIBUTION PANEL 4. CIRCUITS OVER 250V TO GROUND SHALL GALV GALVANIZED •PHOTOVOLTAIC DC DISCONNECT GEC GROUNDING ELECTRODE CONDUCTOR WARNING! ELECTRIC SHOCK HAZARD! COMPLY WITH ART. 250.97, 250.92(3) O SOLAR GUARD GATEWAY GND GROUND 3 �« ;x V 5. DC CONDUCTORS EITHER DO NOT ENTER INDEX HDG HOT DIPPED GALVANIZED ( ) BUILDING OR ARE RUN IN METALLIC a PHOTOVOLTAIC MODULE I CURRENT Imp A RACEWAYS OR ENCLOSURES TO THE FIRST PV1 COVER SHEET Imp CURRENT AT MAX POWER r - ACCESSIBLE DC DISCONNECTING MEANS PER PV2 SITE PLAN JT • (E) VENT PIPE INVS INVERTERS ��� SOIarCity.. °'>D E.n . PV3 STRUCTURAL VIEWS REVISION l SIO Isc SHORT CIRCUIT CURRENT ART. WIRES PV4 UPLIFT CALCULATIONS 6. ALL WIRES SHALL BE PROVIDED WITH 1:30W-0 CZ7 - CC2 ?-5 (E) SKYLIGHT kVA KILOVOLT AMPERE Solar Disconnect STRAIN RELIEF AT ALL ENTRY INTO BOXES PV5 SINGLE LINE ,ty091 Tigard kW KILOWATT AS REQUIRED BY UL LISTING. PV6 ELECTRICAL CA L (E) CHIMNEY LBW LOAD BEARING WALL (4) 7. MODULE FRAMES SHALL BE GROUNDED AT P CUTSHEETS p •r oved Plans MIN MINIMUM WARNING ' ock Hazard THE UL- LISTED LOCATION PROVIDED BY THE ,, A 4 ►,, PV8 CUT SHEETS 4 Date Z- DO NOT 704 RMINALS By l t i _ (N) NEW Terminals on / �tth Band Load sides MANUFACTURER USING UL LISTED PV9 CUTSHEETS LICENSE NEC NATIONAL ELECTRIC CODE may be ener5y[ed in the open PDaitinn GROUNDING HARDWARE. 1 ,'Z,Cj2_T j l �C" ,Q� `� r. NIC NOT IN CONTRACT /��/ " 8. ALL EXPOSED METAL PARTS (MODULE OR # 180498 NTS NOT TO SCALE DC Disconnect FRAMES, RAIL, BOXES, ETC.) SHALL BE OFFICE COPY OC ON CENTER I I GROUNDED USING UL LISTED LAY -IN LUGS P PANEL BOARD LISTED FOR THE PURPOSE. POSTS SHALL BE PL PROPERTY LINES WARNING — EIedtri ock Hazard MADE ELECTRICALLY CONTINUOUS WITH PV PHOTOVOLTAIC DO NOT TO RMINALS ATTACHED RAIL. VICINITY MAP PVC POLYVINYL CHLORIDE Terminals on b and d sid may be ener ed im Ills open Loa PDSIt.on es 9. MODULE FRAMES, RAIL, AND POSTS SHALL ,� r x .. \ p h . " M= t =-� --- {f � . r S SUBPANEL BE BONDED WITH EQUIPMENT GROUND r _ ° ` r 3 � ` r u3, ti — r I ' SCH SCHEDULE DC VOLTAGE IS ALWAYS PRESENT WHEN CONDUCTORS AND GROUNDED AT THE MAIN - - , f y1 y s, { .'' F� , x ` ,_ - a.. -� _ SS STAINLESS STEEL TO SUPILIGHT .. . '� .i,,,,,,,_ � . ELECTRIC PANEL. ( ��;,� -,' �� , -r _ SSD SEE STRUCTURAL DRAWINGS " 7; SOLAR MODULES ARE EXPOSED IF THE EXISTING AC GROUNDING ELECTRODE ' Q ' i '`t , °' �•± "'' i STC STANDARD TESTING CONDITIONS " "� " SW I SOLAR WATER HEATER 6 WARNING —Dual Power Sources IS A COPPER ROD, THE DC GEC SHALL BE . . W' Second source is photovoltaic system 10. ,' , � „_ EITHER #8 THWN -2 RUN INSIDE CONDUIT 'a air a• z .F ' -` - "aj , f TYP TYPICAL 7 ' WARNING – Electric Shock Hazar BONDED AT BOTH ENDS, OR #6 BARE eE �, S�� . y . s UON UNLESS OTHERWISE NOTED No user servlceabb parts nslds ? tA �.} +i F �: -�a ,1 �IAY�S ) ` C ont t thorizedservicerforIasalstance COPPER RUN ALONG BUILDING AS LONG AS �_� per :. r � ° s w Gerrrlan UPS UNINTERRUPTIBLE POWER SUPPLY IT IS NO SUBJECT TO PHYSICAL HARM PER ! ttF ,_s • �` ,. a a VOLT CAUTION I F ;� •,,y o1 VOLTAGE AT MAX POWER (8) so- 4 rs,E��S,�,,,ED.a�E "I Ia15Da�,,, „I , ART. 250.166(8) &(C), 250.64(8) &(E) IF _ s WOa V V m p e " "�M°a "'"D' "� `ro'a"` "n " " �` e E `. ) . ' Voc VOLTAGE AT OPEN CIRCUIT RE14tH ENERGIZED DURING WriIGH HOVRS THE EXISTING AC GROUNDING ELECTRODE IS is " ' WATT n , _; W PV COMBINER BOX A CONCRETE- ENCASED ELECTRODE, THE DC I . > ., -- 1 • (9) WARN I NG - GEC SHALL BE A #6 THWN -2 PER ART. , '� l_ 3R NEMA 3R, RAIN ELECTRIC SHOCK HAZARD 1L--4' • ,,•' *" Ch . - '• r 1 1 ' _ . \ -. 250.166(D). THE GEC SHAL BE :. r I x. !; : - � � k WARNING CONTIGUOUS AS DESCRIBED IN ART A �,> . f ti ', . . t ELE ISHOCK CAT HAZARD IF A GR 250.64(C). _ } �" -- I ✓; REV BY DATE COMMENTS F AULT IS NDIED.THE NORMLLY '� - rv. s - ( 10 ) t„..„: - '�r 6 2 r . � a�14 GROUNDED CONDUCTORS MAY ENER- GIZED AND UNGROUNDED b a „ a iii ®O 1/5/11 CHO MOD FRIA KYO 210 LPU TO KYO 210 LFBS ' $ WARNING ti , �� INVERTER OUTPUT CONNECTION au :& � , ?' Y, o - rt Y (11 DO NOT RELOCATE .:j. s. - ?...:_ .. >• � - ,. - . t> � '. 5 . .:., ► - F 7�e - 5 '. THIS OVER CURRENT DEVICE . CONFIDENTIAL -THE INFORMATION HERON MARKET: MODULES: PREMISE OW(ER: DESCRIPTION: IX8 INEMEIE %.‘ ir D AVIES, BRIAN DAVIES RESIDENCE J 972059 00 't 't”! CONTAINED SHALL NOT BE USED FOR r� RESI 20 KYOCERA KD210GX -LFBS � N IAN EXCEPT A CIT oINC., DESIGN: MO NC SYSTEM: 12025 SW SPRINGWOOD DR 4.2 kW ROOF MOUNT PV SYSTEM DAB ;it sola�' PART TO OTHERS OUTSIDE DISCLOSED I RECIPIENTS SOLARCITY CANOPY C AND RAIL ORGANIZATION, EXCEPT IN CONNECTION WTH PROJECT MANAGER: N TER: TIGARD OR 97223 12/6/2010 THE SALE AND USE OF THE RESPECTIVE • (1) FRONIUS # IG 4000 393 V Foster Park Drive, Suite 140 SOLARaTY EQUIPMENT, WTHOUT THE WRITTEN PAYMENT TYPE: PAGE NAME' T:(650) 638 1028 I �F (6 0) 638 1029 PERMISSION OF SOLAROTY INC. PPA 9716450489 COVER SHEET PV 1 A (888) -SOL -CITY (765 -2489) I www.solarcity.com N SITE PLAN W 4111, Scale: 1/8" = 1' `+ E * TOTAL ARRAY AREA: 329 SQFT. S * TOTAL ROOF AREA: 2260 SQFT. f * 15% OF PV ROOF COVERAGE 40' TO It 1 MP1 ROOF MOUNT (II T PITCH: 18 ARRAY PITCH: 18 DC ED AZIMUTH: 175 ARRAY AZIMUTH: 175 HTOH 8' I — ,- 1 MATERIAL: Comp Shingle Roof ( STORY: 1 M O RAFTERS ROOF SIZE: 2x4 PENETRATION �1 SPACING: 24" O.C. 4 SUPPORT: 2x4 TRUSS 1' FIRE SETBACK MAX. SPAN: C -4" i ji NOTES — ; "\ 1„ 9 PLYWOOD SHEATHING I k % I H T ' H ATTACHMENTS SHALL BE SPACED NO L — — J O GREATER THAN 24 INCHES ON CENTER IN ANY DIRECTION WHERE ARRAY IS ® LOCATED WITHIN 3 FEET OF A ROOF EDGE, HIP, EAVE OR RIDGE. O8ISC 306.4.3 (8) B PV3 GATE SHEET NOTES 0 INVERTER, DC DISCONNECT, & WARNING LABELS(3),(4),(5),(6; A FRONT OF 30 ' 20 DEDICATED PV SYSTEM METER. PV3 HOUSE TO It 10 NOT USED. 1 ® UTILITY METER (6). 1 ® DC DISCONNECT (4),(5). SW SPRINGWOOD DR. ® NOT USED. 0 NOT USED. ® DISTRIBUTION PANEL & WARNING LABELS (1),(2). 0 CONDUIT ROUTED THROUGH INTERIOR Sc WARNING LABEL (8). ®. CONDUIT ROUTED ON ROOF 0 1' 8' 16' _ Q1 NOT USED. REFER TO PV1 FOR WARNING LABELS. CONFIDENTIAL THE INFORMATION HEREIN MARKET: NODULES: PREMISE OMMER: DESCRIPTION: JOB NUMBER: ■%► /�' CONTAINED SHALL NOT BE USED FOR THE RESI (20) KYOCERA # KD210GX —LFBS DAVIES, BRIAN DAVIES RESIDENCE J8- 972059 00 1.= = NT OF BT INC., D N SYSTEM: 12025 SW SPRINGWOOD DR 4.2 kW ROOF MOUNT PV SYSTEM 'I, S o l arCity NOR OR S SHALL IT T BE E DI DISCC LOSEOSE IN WHO D IN WHOLE E LH SOLA OR IN LH SOLARCCITY CANOPY C AND RAIL PART TO OTHERS OUTDE THE RECIPIENTS DATE: ORGANIZATION, EXCEPT IN CONNECTION IWTH PROJECT MANAGER: IN,BTER: TIGARD, OR 97223 12/6/2010 THE SALE AND USE OF THE RESPECTIVE * (1) FRONIUS # IG 4000 393 Vintage Park Drive, Suite 140 SOLARCITY EQUIPMENT, MATHOUT THE WRITTEN IAEN p PAGE NAME: SHEET: REV: Foster Gty, CA 94404 PERMISSION OF SOLARCITY INC. PAT TYPE: 97164504°9 T:(650) 638 -1028 I F:(650) 638 -1029 PPA SITE PLAN PV 2 A (888)-50L-CITY (765-2489) I www.solarcity.can 4' BETWEEN / FOOTINGS —/ SOLAR PANEL INSTALLATION ORDER STAGGERED (PER OR) ATTACHED WITH MODULE O STANDOFF / LOCATE RAFTER, MARK HOLE CLAMPS, " -16 BOLTS, Scale: 11/2" = 1' (1) .— LOCATION, AND DRILL PILOT I L A i r ND CHANNEL NUT HOLE. CUT SHINGLE AROUND , I SOLARCITY SOLAR RAIL \ FLASHING COLLAR. & BOLT ( - SEAL PILOT HOLE AND BOTTOM N N N N CANOPY BOLT ASSEMBLY AilinillIllfat (3) (2) OF CANOPY BASE WITH POLYURETHANE SEALANT. 2' TYP CANOPY FLASHING / LAG CANOPY BRACKET IN (E) 2x4 RAFTERS & BRACKET 1 (3) RAFTER WITH (1) DIA. LAG ®24" SPACING (E) COMP. SHINGLE -- � BOLT IN HOLE CLOSEST TO POST. (E) ROOF DECKING INSTALL CANOPY FLASHING ONTO ( BRACKET. ATTACH RAIL WITH FRONT VIEW OF MOUNTING PLANE B a" DIA LAG BOLT (2 -" EMBED, MIN) CANOPY CLAMP. Scale: 1/2 " =1' -0" (E) RAFTER ATTACHMENTS SHALL BE SPACED NO ATTACHMENTS SHALL BE SPACED NO GREATER THAN 24 INCHES ON CENTER C..:: . TER THAN 24 INCHES ON CENTER IN ANY DIRECTION WHERE ARRAY IS IN ,..., DIRECTION WHERE ARRAY IS LOCATED WITHIN 3 FEET OF A ROOF Lo' ' -:'ED WITHIN 3 FEET OF A ROOF EDGE, HIP, EAVE OR RIDGE ELLit. HIP, ERNE OR RIDGE. 08150 306,4.3 (B) OSISC 306.4.3 (B) w (E) 2x4 TOP CHORD -_,..- 1.11...---ii illir liwf (E) 2x4 16. pp (E) ,I� -2 6' -4" /4' -10" / 4' -10 "—/ (E) 2x4 BOTTOM N (E) LBW CHORD RAFTERS: 2x4 © 24" O.C. SUPPORT: 2x4 TRUSS MAX SPAN: 6' -4" A SIDE VIEW OF MOUNTING PLANE Scale: 1/4 " =1' -0" CONFIDENTIAL THE INFORMATION HEREIN MARKET: MODULES PREMISE OMNER: DESCRIP110N JOB NUMBER: '�∎ 4 CONTAINED SHALL NOT BE USED FOR THE RES � I (20) KYOCERA 1/ KD210GX -LFBS DAVIES, BRIAN DAVIES RESIDENCE JB- 972059 00 1.; ,: B T E PT LA RO T INC., DESIGN: MOUNTING SYSTEM: 12025 SW SPRINGWOOD DR 4.2 kW ROOF MOUNT PV SYSTEM " S o I arCit LH SOLARCITY CANOPY C AND RAIL PART TO OTHERS OUTSIDE THE RECIPIENT'S DATE: ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: TIGARD, , OR 97223 12/6/2010 THE SALE AND USE OF THE RESPECTIVE * (1) FRONIUS # IG 4000 393 Vintage Park Drive, Suite 140 SOLARCITY EQUIPMENT, THOUT THE WRITTEN PAYMENT TYPE: PAGE NAME' REV Foster City, CA 94404 ENT, T:(650) 638-1028 I F:(650) 638 -1029 PERMISSION OF SOLARCITY ENT INC. PPA 9716450489 STRUCTURAL VIEWS PV 3 A (888)-50L-CITY (765 -2489) I www.solarcity.com UPLIFT CALCULATIONS Input Variables Calculations and Values Required Variables Design wind pressures based upon: Mean roof height: 15 ASCE 7 -05 Chapter 6 Wind Loading Exposure category: C Basic wind speed (or city in the future): 90 Equation 6.5.13.3: Component and Cladding Elements Importance factor (1 for residential): 1 Wind pressure P = qh*Cn*G Roof shape: pitched 6.5.10: Velocity pressure Roof angle (degrees): 18 qh = 0.00256`Kz *Kzt`Kd *V ^2`I Roof zone: 3 Contiguous sq. feet of array: 96 From Table 6 -3: Least width of the building: 20 Kz = 0.85 Obstructed wind flow'? TRUE From Figure 6 -4: Kzt = 1.00 Local Topograhphical Features From Table 6-4: (choose "standard or refer to pictures right and below) Kd = 0.85 Type of hill: none From figure 6 -1: Hill height (h) (ft): V = 90 Slope of hill (degrees): From table 6 -1: Horizontal distance from hilltop to house (x): I = 1 leight from bottom of hill to mean roof height (z): From Velocity Pressure Equation: qh = 14.98 Design Wind Pressures From Figure 6 -19B P (lbs. per sq. ft) = qh *Cn *G Cn (uplift) = -1.52 Pd (downforce pressure) = 6.37 Cn (down) = 0.50 Pu (uplift pressure) = -19.36 From 6.5.8.1 G = 0.85 Max Tributary Area Feet Inches Individual Rows in Portrai X (E -W distance between standoffs) = 4 0 Kyocera KD210GX -LP Y (N -S distance between standoffs) = 2 5 Amax (sq. ft.) = 0.5 *L*X L (length of panel in ft. perpendicular to rail) 4.93 X = 4.00 Module Rail Max. Span ! Cantilever (in) = 71 33 1/2 Y = 2.42 Max Uplift Force on a Single Standoff L = N/A Pmax (lbs.) = Amax *Pu Amax = 9.85 Pmax = -191 Factor of safety = Fl *D`NI /Pmax 250 = Fl (pullout capacity of lag (lbs/inch)) Dead Load Calculations 2.50 = D (minimum lag thread depth) DL (lbs/sq. ft.) = (Mm+Mh)/(L*W) 1 = NI (number of lags per standoff) L (length of Kyocera KD21OGX LP modules) 4.93 r 3.27 = Factor of safety W (width of Kyocera KD210GX LP modules) 3.25 Mm (weight of Kyocera KD210GX -LP modules) 40.80 Point Load Calculations Mh (weight of hardware per module) = 7.76 PL (Ibs) = Amax *DL PL = 325 DL = 3.03 Version 6_5 CONFIDENTIAL THE INFORMATION HEREIN MARKET: MODULES: PREMISE OVWIER: DESCRIPTION: JOB NUMBER: ` I b ij, r CONTAINED SHALL NOT BE USED FOR THE RESI (20) KYOCERA # KD210GX -LFBS DAVIES, BRIAN DAVIES RESIDENCE JB- 972059 00 := BENEFIT OF ANYONE EXCEPT SOLARCITY INC., DESIGN: SW SPRINGWOOD DR 4.2 kW ROOF MOUNT PV SYSTEM IN: MOUNTING SYSTEM: PA S oiarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN LH SOLARCITY CANOPY C AND RAIL PART TO OTHERS OUTSIDE THE RECIPIENT'S DATE: ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: INVERTER: TIGARD, OR 97223 12/6/2010 THE SALE AND USE OF THE RESPECTIVE * (1) FRONIUS # IG 4000 393 Vintage Park Drive, Suite 140 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: PAGE NAME: SHEET: REV: T:(650) Foster City, I C (F:(650) 638 - 1029 PERMISSION OF SOLARCITY INC. PPA 9716450489 UPLIFT CALCULATIONS PV 4 A (888)- SOL- CITY(765 -2489) I www.solarcity.com MODULE VOLTAGE RATINGS Voc: 33.2 VDC Vpmax: 26.6 VDC *MODULE CURRENT RATINGS ARE SHOWN AS Isc AND Imp IN THE DC 2 STRINGS OF 10 MODULES STRINGS IDENTIFIER OF THE SINGLE LINE DIAGRAM. (20) KYOCERA # KD210GX -LFBS PV Module; 210W, 190W PTC cr ( 4 ) AWG #10, USE -2 /RHW -2, Black I (N) ARRAY GROUND PER 690.47(D). NOTE: PER 1 I,a . n =, aa . n ,. .a , ,�, 0___ _ ( 1 ) AWG #6, Stranded Bare Copper EXCEPTION NO. 2, ADDITIONAL ELECTRODE MAY NOT BE ; " "E� Li ni l rl ri rm I • Voc = 332 VDC REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE. : : DC, - i • • Vmp = 266 VDC r _ - L `J Ail _ GND : • Isc = 8.58 A DC AWG #6, Stranded Bare Copper (1 )-■`<:) i i I • Imp = 7.9 ADC CI Ground Rod; 5/8" x 8', Copper (1) - - I - 1 I :..i- (1 SHOALS # STG.ICU.M4.F L - J Connector; MC4 U -Joint Connector, Female (1 ) SHOALS # STG.ICU.M4.M Connector; MC4 U -Joint Connector, Male EGCDC - DC. LOCATED UNDER ARRAY I I (E) 200A MAIN ELECTRIC SERVICE PANEL i i USE -2 10 AWG 2 #10, USE-2/RHW-2, Black NO MAIN BREAKER (1 )STABLOK # NA225 FRONIUS # IG 4000 (1 )- ( ) # / FEDERAL PACIFIC ELECTRIC PANEL 1410 -14 -200 Breaker; 25A, 2 -Pole Inverter; 4000W, 240V, 500VDC, 94% EFF. i i (1) AWG #6, Stranded Bare Copper EGC LOCATED AT END OF BUSSING (E) WIRES AND CONDUIT Q - ( Conduit Kit; 3/4" EMT _ (1) AWG #10, THWN -2, Black • Voc = 332 VDC AC DISCONNECT y:_ (,)AWG AWG #10, THWN -2, Red r - - • PER ART. 690.17 L Vmp = 266 VDC ® BOTTOM OF BUSS - (1) AWG #10, THWN -2, White NEUTRAL INVERTER : • Isc = 17.16 ADC - (1) AWG #6, THWN -2, Green GEC /EGC GFP ; ; LINE • Imp = 15.8 ADC (E) LOADS I rp Gyro CI - (1 ) Conduit Kit; 1/2" EMT ti Z 018 I� y o � IC) 1 I I iii (1--- ,,----: 4 • Vmp = 240 VAC I i i (1 )SQUARE D # HU361RB • Imp = 16.67 AAC I I I I EGC DC -� DC , LOAD Disconnect; 30A, 600V, NEMA 3R 3/ A ■ I I 1 1 q. • ��_ TOP BOTTOM L1� _ - -�- - - - - _ LE GC_ GC_ _ I� I .__E � I LDS- J N N 1 DC• o EGC/GEC -M- _ EGC/GECJ Itl Z - - _ • (1 ) AWG #10, THWN -2, White ( 1 ) AWG #10, THWN -2, Black TO 120/240V #8 JUMPER l SINGLE PHASE - (1) AWG #10, THWN -2, Green EGC UTILITY SERVICE l (1 )Conduit Kit; 1/2" EMT I l AC & DC DISCONNECTS ARE • Voc = 332 VDC COOPER # B Line Meter Socket 011( 1 ) INTEGRATED INTO • Vmp = 266 VDC AWG #6, Solid Bare Copper (1 ) I Meter Socket; 125A, 4- 14AWG, Ring Type THE INVERTER. • Isc = 17.16 ADC • BOND (N) #8 EGC /GEC TO BOTH (N) GROUND Imp = 15.8 ADC ROD AND (E) GEC WITH IRREVERSIBLE CRIMPS PER ART 250.64(C) AND ART 250.66(A) Ground Rod; 5/8" x 8', Copper (1 ) CONFIDENTIAL THE INFORMATION HEREIN MARKET: MODULES: PREMISE OWNER: DESCRIP110N: JOB NUMBER: ` vb�j4, CONTAINED SHALL NOT BE USED FOR THE REST (20) KYOCERA # KD210GX -LFBS DAVIES, BRIAN DAVIES RESIDENCE JB- 972059 00 1; ,: NOR NEENEFIT LL T OLARC ORCIN DESIGN: MOUNTING SYSTEM: 12025 SW SPRINGWOOD DR 4.2 kW ROOF MOUNT PV SYSTEM ter; S olarCity LH SOLARCITY CANOPY C AND RAIL PART TO OTHERS OUTSIDE THE RECIPIENT'S DATE: ORGANIZATION, EXCEPT IN CONNECTION WITH PROICT MANAGER: INVERTER: TIGARD, OR 97223 12/6/2010 THE SALE AND USE OF THE RESPECTIVE * (1) FRONIUS # IG 4000 393 Vintage Park Drive, Suite 140 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: Foster City, CA 94404 INC. PAYMENT "PE: 9716450489 T:(650) 638-1028 I F:(650) 638-1029 PERMISSION OF SMARMY Y PPA SINGLE LINE P V 5 A (888)-50L-CITY (765 -2489) I www•solarcity.com 1 Conductor Sizing per Art a. must ELECTRICAL CALCULATIONS a. Conductor must t have 30 0 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). Module: 20 ,r1I Inv Pwr W PTC Voltage Drop Calculations Version 5 b. Conductor must have (after corrections for conditions of use) >= Inverter 1: 1 l : ,. y!,ir Vdro ( Imp) ' (2 ` Length) ` (Resistance) 1 (Vmp) ANNE. continuous current per Table 310.16. Module I f Imp (A) 1 Max. Length (ft) Wire Inverter 2: / - „ „ ' ' . ., String: 7.9 50 C AWG 10 at Max Ave Hi: 30 deg F Module: Vdrop = (7.90 A ' 100 It ` 0.00124 Ohms) f 244 V = 0.40% c. Evaluate conductor temperature at terminations per 110.14(C). invader 3: - 1 y 4 Branch: I 15.8 I 75 . 1C AWG 101 at Max Ave Hi: 80 deg F Ampacity of wire derated for conditions of termination must be Module: Vdrop = (15.80A * 150 ft `0.00124 Ohms) 1 244 V = 1.21% >= continuous current *1.25. All string terminations are rated at Inverter 4: - t Total voltage drop in DC conductors =I 1.61 %I 90' C. Inverter: I 16.67 1 15 IC AWG 11 at 240V Total- - nodules Total Inv Pwr PTC Vdrop = (16.67 A ' 30 ft ` 0.00120 Ohms) / 240 V 0.25% 2. OCP Sizing per Art 690.8(6)(1) Photovoltaic Module Electrical Specifications: Total STC Combinedi 16.67 I 0 IC AWG 101 at 240V a. Round up to next size per Art 240.4(B) Voc= '33 V deg F C Vdrop = (16.67 A • 0 ft ` 0.00120 Ohms) 1 240 V 0.00% Vrnp= 26 V Record Low Temp: 8 Total voltage drop in AC conductors = 0.25% Isc= 8 A Max Average Hi Temp: 80' Total voltage drop in AC and DC conductors = 1.66% 3. Conductor Sizing per Art 690.8(B)(1) Imp= 7. A Record Hi Temp: 106 a. Conductor must have 30 deg. C ampacity >= 125% of continuous Tvoc= -0 V/degC current per Art 215.2(A)(1). Tisc= 61 mAlder C String Tyne A and 2 Combined Strings Tyne A Voc Correction Method: '' ..• :.'' Branch Circuit Type A 10 modules per series string b. Conductor must have (after corrections for conditions of use) >= Fronius IG4000 2 strings per branch 1 -way wire length: 75 ft 10 K iocera +tr- + zr, Inverter Min Vdc Input. Vdc continuous current per Table 310.16. Voc= - 3 V Min Vmp at Max Temp: Ydc Voc= V Vrnp 2: V Max Voc at Min Temp Z Vdc m Vp= V c. Evaluate conductor temperature at terminations per Art 110.14(C). lsc= 8 A Inverter Max Vdc Input Vdc Ilse= A Ampacity of wire derated for conditions of termination must be Imp= 7'. A Max String Size: Imp= A >= continuous current *1.25. All branch terminations are rated at Icons= .' _ A Art 690.: A 1 -way wire length: 50 ft Icont= A Art 690_; A, 1 75' C min. 1.a Try USE- 2/RHW -2 at 90 deg C: Table 310.16 3.a Try THWN- 2IUSE -2 at 90 deg C Table 310.16 Icont' 1.25 = (Amps) 25.71$ 4. OCP Sizing Icorlt'1 =(Amps1 13.41 30 • d s C a • _ a. Round up to next size per Art 240.4 B 30 d ' C am » ; ,; 48 - 3.b Icont= (Amps) , 21. P P O 1.b Icons= (Amps) 10.7 "' " " Start ampacity 44' Start ampacity 4 Temp- derate (%) 0 71 5. Conductor Sizing per Art 690.8(B)(1) Temperature derate ( %=F) $ 0 7 Cn fill Be dt. firate (% # 1 a. Conductor must have 30 deg. C ampacity >= 125% of continuous Conduit fill derate (%t) € Berated current per Art 215.2(A)(1). Derateda sac Term 1 Term2 Temp table 7 1.c !coral 25= (Amps) WWI. 3.c Icont*1.25= (Amps) _ .E iS.81 b. Conductor must have (after corrections for conditions of use) >= Ampacity Ampacity 35 35 continuous current per Table 310.16. c. Evaluate conductor temperature at terminations per Art 110.14(C). 2 Scant • 1.25 = (Amps) 3.d OCP size = Ampacity of wire derated for conditions of termination must be OCPsize= Combined inverter output >= continuous current *1.25. All inverter output terminations are serve 240 Pons Inverter T • : A Ou • t Total Inverter Power= Watts 1-way wire length. 0 ft rated at 75' C. 1 -way wire length 16 ft leont = * of inverters`rnax inverter current Art 690.8(AX 1) [cant= A Art 690.: A ,1 (cent = Arm s 6. OCP Sizing 4 Icont "1.25 = (Amps) - „ A Art 690 8(BX1) 6 Icoft "1.25 = (Amps) A Art 690.8(8X1) a. Round up to next size per Art 240.4(B) OCP size = A Art_ 240_. A OCP size = A Art. 240.. A 5.a Try THWN -2 at 90 deg C. Table 310.16 7.a Try THWN -2 at 90 deg C. Table 310.16 Icont * 1.25 = (Amps) Icont " 1.25 = (Amps) 7. Conductor Sizing per Art 690.8(B)(1) 30 d-. C am = 30 . . C a ' • it = a. Conductor must have 30 deg. C ampacity >= 125% of continuous 5.b Icont= (Amps) 16.67 7.b loom= (Amps) MU current per Art 215.2(A)(1). Start ampacity 40 Start ampacity Temperature derate ( %=F) 0.91 Temp. derate ( %) b. Conductor must have (after corrections for conditions of use) >= Conduit fill dente (% = 1 Cndt. fill aerate (%t) - continuous current per Table 310.16. Derated arm - 36.4 Derated am. . 5.c Icont`1.25= (Amps) 20.83 7.c Icont`1.25= (Amps) c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity 35 Ampacity Ampacity of wire derated for conditions of termination must be >= continuous current *1.25. All inverter output terminations are rated at 75' C min. CONFIDENTIAL - THE INFORMATION HEREIN MARKET: MODULES: PREMISE OWNER: DESCRP110N: JOB NUMBER: �lb,11II CONTAINED SHALL NOT BE USED FOR THE RESI (20) KYOCERA # KD210GX -LFBS DAVIES, BRIAN DAVIES RESIDENCE JB- 972059 00 : BENEFIT OF ANYONE EXCEPT SOLARCITY INC., DESIGN: MOUNTNG SYS1131: I SoIarCity ORGANIZATION, EXCEPT IN CONNECTION WITH INVERTER: T IGARD, OR 97223 NOR SHALL IT BE DISCLOSED IN WHOLE OR N LH SOLARCITY CANOPY C AND RAIL 12025 SW SPRINGWOOD DR 4.2 kW ROOF MOUNT PV SYSTE DA,E PART TO OTHERS OUTSIDE THE RECIPIENTS PROJECT MANAGER: 12/6/2010 THE SALE AND USE OF THE RESPECTIVE * (1) FRONIUS # IG 4000 393 Vintage Park Drive, Suite 140 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: Foster City, CA 94404 PERMISSION OF SOLARCITY INC. MINT TYPE 9716450489 PV 6 A T:(650) 638 -1028 I F:(650) 638 -1029 PPA ELECTRICAL CALCULATIONS V (888) -SOL -QTY (76 -2489) www.solarcity.com PV MODULE KD21 OGX-LFBS CE: KY 0 CE R2 ELECTRICAL CHARACTERISTICS Current - Voltage characteristics of Photovoltaic Current - Voltage characteristics of Photovoltaic Module KD 210GX -LFBS at various cell temperatures Module KD 210GX -LFBS at various irradiance levels Cutting Edge Technology _ '" "A"s' • '� _= As a pioneer with 35 years in solar, Kyocera demonstrates leadership in 210 WATT . the development of solar energy products. Kyocera's Kaizen Philosophy, , — 111. , __,_ commitment to continuous improvement, is shown by repeatedly MUM , ..:. �1 ■ achieving world record cell efficiencies. HIGH EFFICIENCY MULTICRYSTAL tt 1>a ; x __, Quality Built In PHOTOVOLTAIC MODULE 3 ��•I11 I M it, - New frame technology allows for end mounting with 2400 Pa (50 psf) ,,__=I� • _�-� , �� .. � � � and traditional mounting under 5400 Pa (113 psf) to support increased M■ : m ill load " '� • UV stabilized. aesthetically pleasing black anodized frame ■■■ a -„E � _—f - Supported by major mounting structure manufacturers o ,o a 30 to s x • - Easily accessible grounding points on all four corners for ■ll■■ vdaw ww.m fast installation Proven junction box technology with PV wire to work with _���� transformerless inverters SPECIFICATIONS - Quality locking plug -in connectors to provide safe & quick connections ■■■■ • Physical Specifications ws,ww) New Process Improvements - All solar cells are fabricated with a new proprietary etching and t�y� 01110113060 coating process which translates Into a 'smoother' appearance tamer while maintaining the same gridline and bus -bar design. wniw All modules have added crossbars on the back side of the module 1111111.1111 ■ 1111111.1111 " ■ :Ell' 9€ siT for greater support and stability in harsh conditions, including $i f' 117 high wind and snow load regions. ■■■■.■ Reliable KD2100X -LFBS - Superior built -in quality ..■.. ~ Proven superior field performance NEC 2008 Compliant fi right power tolerance UL 1703, I 9 001 ...EN 7; ISO 14001 111. 11 Warranty Certified and Registered ,_ I - 25 year warranty 5 year workmanship warranty Class C 11 ■■■ - . + o co rttJ OW •I_� PV.i rr M +.o.wwr.... , m eo lftad Olv dn,wer•et ►. • Spscmcatlotts • eadliel Pufenewee .Ider tfrtdd leaC1.ilt r • cue ,--za. lia•noan POMP Gerd 2101 (+e4-3 %) Number par Modulo I S . 1, x W II.drtUn POMP Weep wag WWIN i — ` Il.b..l �r.r attrRl 7.1011 • Melds Ow Clan Mid 332V Leap eal X DOplh x•rrluistsMwlilal _ r► ` / S-2 _ tlha t Cwt Owned (Yr USA weight 1«l0{at 7ba "r i� ..- �...*. 622,irrz'�j � a r Met C t a1cv Cede l hSmnl37.lim,l :15ttnmf29.iinl —7--r- *- T r. % ,, ,ryisi���1� r ,� Trr p �a cb�uwudWe - t > -s ...,..r .iirNiiiip iiINN/ II/ rI /_rI I I f> J-.G ��. "� - s - �is . i = Nig� - - - - ` , �,� r� II I r_ • Tw sr is C ase nt of Yc 5.15x10 A/C • Jtwdbn Gott pr.�iwl r r t�� fl� / �// I /Ii ��` �� r�� II I / _rI vtc .rr �rs.aa _ - i,N /I // /�=// /I //�II drt X tOM$ l mar rrrrrr rI / III//// /I ■ I I0C; NM lP Cods P85 NW � � a"" L er tg Mt X w orNslittFlMsf 414,470, 1- ; ; If / i / ' //� �� / /// M .dns an Paver (Ptt.d low /` . ' ' � %i '/ ' - / ' �•iI� % % % % I %� Weep . ' �oov �•on«wro Torres Tore -40t - 90t / , -, - �/Iy - .4, AP WA. � /a. I 1 Shot aatotnref 6.E?A Maximum Fur 15A ArArair ...am 'y �'''� ' ...I . I . I / ISO 9001 and e , 14001 mod 'y Codified and Registered , � '�' ' � ' ' � . . / grocoro rcmnresfiai9r•t:o modY nose speificnions w7Nr 'tnoriw i / i / � C$ KHOCER2 f NO-223-9580 to fre 8e0- 523 -2329 fax SOLAR by KYOCERA t7i'XL,/ � 11.-.1 i CONFIDENTIAL - THE INFORMATION HEREIN MARKET: MODULES: PREMISE OWNER: DESCRIP110N: JOB NUMBER: 'I CONTAINED SHALL NOT BE USED FOR THE RESI (20) KYOCERA # KD210GX —LFBS DAVIES, BRIAN DAVIES RESIDENCE JB- 972059 00 1.= r BENEFIT OF ANYONE EXCEPT 0TY INC., DESIGN: I/ ` � OIa' NOR SHALL IT BE DISCLOSED IN WHOLE OR IN MOUNTING SYSTEM: LH SOLARCITY CANOPY C AND RAIL 12025 SW SPRINGWOOD DR 4.2 kW ROOF MOUNT PV SYSTE � PART TO OTHERS OUTSIDE THE RECIPIENTS IN WHOLE DATE; o ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: INVERTER: TIGARD, OR 97223 12/6/2010 THE SALE AND USE OF THE RESPECTIVE * (1) FRONIUS # IG 4000 393 Vintage Park Drive, Suite 140 SOLARCITY EQUIPMENT, WI PAYMENT TYPE: PAGE NAME. REV: 638 to28 I CA WITHOUT THE WRITTEN F:(650) 38 - 1029 PERMISSION OF s MENT, Y INC. PPA 9716450489 CUTSHEETS PV 7 A (888) -SOL -QTY (765 -2489) I www.solarcity.com INVERTER FRONIUS IG FRONIUS IG 4000 / 5100 / 4500 -LV - Specifications DC Input Data FRONIUS IG 4000 _ FRONIUS IG 5100 FRONIUS 10 4500-U1 Recommended PV power _ 3000 - 5000 Wp 4000 - 6300 Wp 3600 - 5500 Wp Max. DC input voltage 500 V 500 V 500 V • Operating DC voltage range _ 150 - 450 V 150 - 450 V 150 - 450 V Max. usable DC input current 26.1 A 33.2 A 29.3 A AC Output Data FRONNIB 04000 FRONIUS 10 5100 FRONIUS IG 4600 -W Maximum output power 040° C 4000 W 5100 W 4500 W Nominal AC output voltage 240 V 208 V Utility AC voltage range 212 - 264 V (240 V +10% / -12%) 183 - 227 V Maximum AC current 16.7 A 21.3 A 21.6 A Maximum utility back feed current 0.0 A 0.0 A 0.0 A Operating frequency range 59.3 - 80.5 Hz (60 Hz nom) Total harmonic distortion < 5 % Power Factor (cos phi) 1 g General Data FRONIUS IG 4000 FRONIUS I0 5100 I FRONIUS 10 4500 -LV Max. efficiency 95.2 % 95.2 % 94.4 % Consumption in stand -by < 0.15 W (night) tj Consumption during operation 15 W _ Enclosure NEMA 3R Size(lxwxh) 26.4 x 16.5 x 8.8 in (720x418x223mm) Weight 42 lbs. (19 kg) x Ambient temperature range -5 to 122 °F ( -20 to +50 °C) Cooling controlled forced ventilation _ Integrated DC and AC disconnects standard UL approved DC & AC disconnects Protection E. Ground fault protection Internal GFDI, in accordance with UL 1741 DC reverse polarity protection Internal diode Islanding protection Internal, in accordance with UL 1741, IEEE 1547 § s Over temperature Output power derating Surge Protection Internal DC & AC protection, Tested to 6 kV . V Compliance Ed Safety UL 1741 v n EMI FCC Part 15; Class A & B Anti- Islanding protection UL 1741, IEEE 1547 a Ground fault detector and interrupter Compliant with NEC Art. 690 requirements, UL 1741 _ x 5 Miscellaneous I E Maximum AC over current protection Two -pole, 30 A circuit breaker s AC wire sizing Use maximum AWG 6 194 °F (90 °C) copper wire a s DC wire sizing ilea maximum AWG 6194 °F (90 °C) copper wire m s AC disconnect 32 A S °- DC disconnect 40 A Warranty I 10 year Premium Warrar is Standard ' i re � ronius f, fi U Distributed by 5 r 4 E ? E Fronius USA LLC ` E Solar Electronic Division 5 10421 Citation Drive Suite 1100 Brighton, Mi 48116 Phone: 810-220-4414 Fax: 810-220-4424 E -Mail: pv- usOfronius.com o www.fronius- usa.com - • timac€ 7 _Y - 70% ��.n�.�... »' - CONFIDENTIAL - THE INFORMATION HEREIN MARKET. MODULES PREMISE OWNER DESCRIPTION: JOB NUMBER: - � 1∎1 I CONTAINED SHALL NOT BE USED FOR THE RESI (20) KYOCERA # KD210GX —LFBS DAVIES, BRIAN DAVIES RESIDENCE J B-9 72059 00 '- ; BENEFIT OF ANYONE EXCEPT SOLARCITY INC., DESIGN: : MOUNTING SYSTEM: 12025 SW SPRINGWOOD DR 4.2 kW ROOF MOUNT PV SYSTEM I I I S oIar1( i1 y NOR HALL IT BE DISCLOSED IN WHOLE OR IN LH SOLARCITY CANOPY C AND RAIL PART TO OTHERS OUTSIDE THE RECIPIENT'S DATE: ORGANIZATION, EXCEPT IN CONNECTION WITH ACT MANAGER: INVERTER: TIGARD, OR 97223 12/6/2010 THE SALE AND USE OF NE RESPECTIVE * (1) FRONIUS # IG 4000 393 Vintage Park Drive, Suite 140 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: Foster City, CA 94404 PERMISSION OF SOLARCITY INC. PAYMENT TYPE: 9716450489 T:(650) 638 -1028 I F:(650) 638 -1029 PPA C U T SH E E TS P V 8 A (666) SQLCITY (765 -2489) I www.solarcity.com MOUNTING HARDWARE vat mei k [1] i i , .„....„;...............,..........„„..„. z �� APPROVED INSTALLATION METHOD • Roots (brackets) are to be mounted no further RESIDENTIAL SOLAR MOUNTING SYSTEM than 8'apart. NUMBER OF EMBEDMENT • Rafters must be located. Pilot holes must be drilled into L0.G (INCHES) Canopy is the strong, safe, waterproof mounting system for structurally attaching the center of rafters 1 28 I 7.5 solar panels to composition shingle and wood shake roofs. A715 grade 50 high • Shingle course immediately above penetration shall be cut 2 33 1 3 strength structural steel with durable corrosion resistant coating provides more using provided template to accommodate flashing. 3 43 2 2.5 I strength than aluminum and better corrosion resistance than stainless steel. Bracket- • Local wind conditions, exposure, roof angle, and position 4 50 2 3 ■ style attachment allows for shingle flashings to completely cover penetrations, of array on roof will determine design wind pressure. y g g p y p TMs chat assumes 15 sq. tt. at fewer per panel providing excellent long -term waterproofing. Standard Installation of Canopy applies when design wind and minimum 1.5 penetrations pe, W.I. -- -- — • pst values to be calculated aeprding to ASCE / Ob. pressures are found to be 28psf or lower arid requires one 2e .inch lag bolt in the primary position. For all other cases, • Precision engineered bracket geometry provides stiffest see chart to right. uplift resistance of any mounting bracket. Rated to 500 lbs. • • Flashing is to be Inserted under course of shingles above • A715 grade 50 high strength structural steel provides penetration and pressed down over root until it snaps more strength than aluminum. - - into place. littse • Proven /5 year corrosion resistant hot -dip galvanized — f —.-- • Rail is attached with rail locking clamp. i coating. Laboratory tests show canopy has better corrosion • resistance than common stainless steel. • Shingle -style flashing completely covers penetration, providing • Flashing better long term leak protection Than neoprene cone (lashings. • • Lags and Washers I i Root - Bracket ® Shingle Flashing locks in place for best water proofing 4 eiD 4 , Root - Bracket installed ( I x • 2x 5/16 lag bolts Flashing installed ' i i a l' • 2x 5/16 flat washer I I „�� � , • R a i l installed _ - I +� Canopy root precision engineered mounting bracket ` \� 1) 8" OC Max ! "`� + ; , 9 Roof rafter �! Rail ..., _ `_i ~ 1�'.. - fi lia l . ��r � S O I af 1 i t jf m 888 -SOD -CITY 1 888 - 765 -2489 I WWW.SOLARCITY.COM CONFR�ITIAL -THE INFORMATION HEREIN MARKET: MODULES: PREMISE OMER: DESCRPTICN: '� NUMBER: = ' /I I /1 CONTAINED SHALL NOT BE USED FOR THE RESI (20) KYOCERA KD210GX —LFBS DAVIES, BRIAN DAVIES RESIDENCE JB- 972059 00 .; , : BENEFlT OF ANYONE EXCEPT ITY INC., DE9GN: MOUNTING SSTOI: Ai; S oIarC i ty IN WHO NOR SHALL IT BE DISCLOSED IN WHOLE OR IN LH SOLARCITY CANOPY C AND RAIL 12025 SW SPRINGWOOD DR 4.2 kW ROOF MOUNT PV SYSTEM PART TO OTHERS OUTDE THE RECIPIENTS DATE: ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: ,�: TIGARD, OR 97223 12/6/2010 THE SALE AND USE OF THE RESPECTIVE * (1) FRONIUS # IC 4000 393 Vintage Park Drive, Suite 140 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE PAGE NAME SHE. REV; T:(650) 638 Foster Ci I F(94404 38 -1029 PERMISSION OF SOLARCITY INC. PPA 9716450489 CUTSHEETS PV 9 A (888) - SQL -CITY (765 -2489) I wvvw.solarcity.com