Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
k 4 1,,, . CITY OF TIGARD MASTER PERMIT ^ . . . I O N � DEVELOPMENT SERVI DATE ISSUED: 06/08/98 8- 193 A� PARCEL.: F'S 1 O2CD -03800 SITE ADDRESS...: 13960 SW 100TH AVE SUBDIVISION....:SHILO C O ZONING: R- -4.5 BLOCK LOT .............:007 JURISDICTION: TIG Remarks: 550 sq. ft. addition to existing house - - - - - - -- ----- - - - - - -- BUILDING -- ------ --- - ------ --- -- - --- ---- - - - - -- REISSUE: STORIES : 1 FLOOR AREAS BASEMENT...: 0 sf REQUIRED SETBACKS - - -- REQUIRED CLASS OF WORK.:ADD HEIGHT • 15 FIRST • 550 sf GARAGE • 0 sf LEFT • 5 SMOKE DETECTRS: TYPE OF USE...:SF FLOOR LOAD • 40 SECOND...: 0 sf FRONT • 20 PARKING SPACES: 0 TYPE OF CONST.:5N DWELLING UNITS: 1 FINBSMENT: 0 sf RIGHT • 5 OCCUPANCY GRP.:R3 BDRM: 3 BATH: 2 TOTAL - - -: 550 sf VALUE..$: 48000 REAR : 15 - -- - --- - - - - -- - -- �L IBING ----- -- - - -- ------- - - - - -- SINKS • 0 WATER CLOSETS.: 1 WASHING MACH..: 0 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 0 TRAPS • 0 LAVATORIES • 1 DISHWASHERS...: 0 FLOOR DRAINS..: 0 SEWER LINE ft: 0 SF RAIN DRAINS: 0 CATCH BASINS..: 0 TUB /SHOWERS...: 1 GARBAGE DISP..: 0 WATER HEATERS.: 0 WATER LINE ft: 0 BCKFLW PREVNTR: 0 GREASE TRAPS..: 0 OTHER FIXTURES: 0 - -- - - -- ------- - - - - -- - - -- MECHANICAL ------------------- FUEL TYPES- - -- FURN (100K ..: 0 BOIL /CMP ( 3HP: 0 VENT FANS • 0 CLOTHES DRYERS: 0 GAS FURN ) =100K ..: 0 UNIT HEATERS..: 0 HOODS : 0 OTHER UNITS...: 1 MAX INP.: 25'. Y BTU FLOOR FURNACES: 0 VENTS • 0 WOODSTOVES : 0 GAS OUTLETS...: 0 - ------ ELECTRICAL - - -- - - RESIDENTIAL UNIT— - -- SERVICE /FEEDER - -- —TEMP SRVC /FEEDERS— -- BRANCH CIRCUITS— - -- MISCELLANEOUS - - —ADD'L INSPECTIONS - 1000 SF OR LESS: 0 0 - 200 alp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0 EA ADD'L 500SF.: 0 201 - 400 alp..: 0 201 - 400 amp..: 0 1st W/O SVC /FDR: 8 SIGN /OUT LIN LT: 0 PER HOUR : 0 LIMITED ENERGY.: 0 401 - 600 alp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT • 0 MANF HM /SVC /FOR: 0 601 - 1' amp.: 0 6014-amps -1000 v: 0 MINOR LABEL -10: 0 1000+ amp /volt.: 0 - - - - -- PLAN REVIEW SECTION --- - --- -- Reconnect only.: 0 ) =4 RES UNITS..: SVC /FDR) =225 A.: ) 600 V NOMINAL: CLS AREA /SPC OCC: - - -- --------------- - - - - -- ELECTRICAL - RESTRICTED ENERGY — A. SF RESIDENTIAL - ----- --- - - - - -- B. COMMERCIAL------ - - - - -- --- --------------------------- AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM • INTERCOM /PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM..: OTH:X .. BOILER HVAC • LANDSCAPE /IRRIG: PROTECTIVE SIGN: GARAGE OPENER..: CLOCK • INSTRUMENTATION: MEDICAL OTHR: •• HVAC DATA /TELE COMM.: NURSE CALLS • TOTAL it SYSTEMS: 0 Owner: Contractor: TOTAL FEES:$ 805.20 MARSHALL STURGILL OWNER This permit is subject to the regulations contained in the 13960 SW 100TH AVE Tigard Municipal Code, State of Ore. Specialty Codes and all TIGARD OR 97223 other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is Phone II: 515 -4131 Phone 41: not started within 180 days of issuance, or if the work is Reg C..: v,,v40 suspended for more than 180 days. ATTENTION: Oregon law -------- - - - - -- ----- - - - - -- requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952- 001 -0010 through OAR 952 -001 -0080. You may obtain copies of these rules or direct questions to OUP by calling (503)246-1987. - ----- - - - -- ------------------ REQUIRED INSPECTIONS ---- -- - - -- Erosion 844 -8444 PLM /Underfloor Low Voltage Building Final Footing Insp Mechanical Insp Insulation Insp Foundation Insp Plumb Top Out Electrical Final Post /Beam Struct Electrical Rough Mechanical Final Post /Beam Meehan Fracp Plumb Final C�� Issued By:___ - // . 0c Per Signature:_�i/..7„/ ,ISi,. ++++++ ±±++ ++++++ ++ •±-h-I --F-I ++ ++±-I••-h+ +•+ ... +...F•++ +-I-.i- ±±-I-- f•±++±- ++++++++++++" +±+•i-± Call 639 - 4175 by 7:00 p.m. for an inspection needed the next business day Plan Check # -J %2 YR.. CITY OF TIGARD Residential Building Permit Application Recd By a c,/ 1315 SW HALL BLVD. New Construction Additions or Alterations Date Rec'd 7 TIGARD, OR 97223 Single Family Detached or Attached (Duplex) Date to P.E. - V 503 - 639 -4171 Date to DST 4 511/41.46 F 503 - 684 -7297 - P Permit # � 9 — 0( 6 (3 Print or Type / Called Incomplete or illegible applications will not be accepted Name of Project Name Job r&Ct(j t ct l / ,5 - fur/ � / Address Site Address 7-136&71 Architect Mailing Address /37ko jbc) /0) City /State Zip Phone Name i al c (Sta( 5 - Ivo l Owner Mailing Address i/ Name PD f30 K /52 7 375 = y13/ City /State , Zip Phone Engineer Mailing Address TUe /& fin r or 9 7Of, Z 0044441 City/State Zip Phone General Name Contractor c S e- 1 f Describe work New 0 AdditiortXr Alteration 0 Repair 0 Mailing Address to be done: Prior to permit Additional Description Pf Wpoyk : issuance, a copy City/State Zip Phone e. .hDUS t k4Lh lC JI n j a- jalCi-Q �J of all licenses are required if Oregon Const. Cont. Board Exp. Date PROJECT /� co expired in COT Lic.# VALUATION $ y database Mechanical Name NEW CONSTRUCTION ONLY: Sub - Atkt - SELF Sq. Ft. House: &ION', Sq. Ft. Garage Contractor Mailing Address 4 550 Prior to permit Corner Lot YES NO Flag Lot YES NO issuance, a copy City/State Zip Phone (check one) (check one) of all licenses Restricted Audio /Stereo Burglar are required if Oregon Const. Cont. Board Exp. Date Energy System Alarm expired in COT Lic.# database Installation Garage Door HVAC Plumbing Name Opener _ Systems Sub - 9rEW —S'&cE (check all that Other: Contractor Mailing Address apply) Will the electrical subcontractor wire for all YES NO restricted energy installations? Prior to permit City/State Zip Phone Has the Subdivision Plat recorded? N/A YES NO issuance, a copy of all licenses are Oregon Const. Cont. Board Exp. Date required if Lic.# Reissue of MST #: Solar Compliance expired in COT (Calculation Attached) database . Plumbing Lic. # Exp. Date I hearby acknowledge that I have read this application, that the information given is correct, t: :at I am the owner or authorized Name agent of the owner, and that plans submitted are in compliance with Oregon State laws. Electrical .'E4/ = azure f r /A t at "A Sub- Mailing Address Contractor CQ91a0 --hex ,ame��� ,// Phone Zne W Zip Phone // / /1° �p Prior to permit FOR OFFICE USE ONLY. issuance, a copy P) t #: , Map/TL #: of all licenses are Oregon Const. Cont. Board Exp. Date (-14 - () required if Lic.# n �� � - �- i ' �� � e_16 � � ��?� k Zone: Solar: expired in COT S tb c �� /) _ 9 5 i/ database Electrical Lic. # Exp. Date /� Tirering Approval: Planing Approval: TI F: y 1 J P t ,1 I:SFREM.DOC (DST) 4/97 Permit #: n 2r 1 if ' o/ 9 3 : F 4 Address: 13 S �D 51) 1(20 i7 +C .++�rrr�,. ,Z NlV ..,,;.,j +t Issued by: Date: Statement: Information Notice to Property Owners About Construction Responsibilities Note: Oregon Law, ORS 701.055(4), requires residential construction permit appli- cants who are not registered with the Construction Contractors Board to sign the following statement before a building permit can be issued. This statement is required for residential building, electrical, mechanical, and plumbing permits. Licensed architect and engineer applicants, exempt from registration under ORS 701.010(7), need not submit this statement. This statement will be filed with the permit. Fill in the appropriate blanks and initial boxes 1 and 2, and either box 3A or 3B: 1. I own, reside in, or will reside in the completed structure. 2. I understand that I must register as a construction contractor if the structure is sold or offered for sale before or upon completion. n 3A. My general contractor is I I (Name) Contractor regis. # I will instruct my general contractor that all subcontractors who work on the structure must be registered with the Construction Contractors Board. OR 3B. I will be my own general contractor. If I hire subcontractors, I will hire only subcontractors registered with the Construction Contractors Board. If I change my mind and hire a general contractor, I will contract with a contractor who is registered with the CCB and will immediately notify the office issuing this building permit of the name of the contractor. I hereby certify that the above information is correct and that I have read and do understand the Information Notice to Property Owne s about Construction Responsibilities on the reverse side of this form. ?1/17 7// ' : 577/ , r (. _nature of permit applicant) (Date) (White copy to issuing agency permit file, pink copy to applicant) rr CITY OF TIGARD BUILDING INSPECTION DIVISION 6 O 1 00 / 24 -Hour Inspection Line: 639-4175 Business Line: 639 -4171 BUD C e- 2 —Date Requested 0 AM M Location /,..390 `f2d ° Suite MEC Contact Person Ph PLM Contractor Ph SWR ILDIN h Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: fZ Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc • PART FAIL *'`"1 BIN Post & Beam Under Slab Top Out /L/4 Y Water Service Sanitary Sewer R a in II rains • PART FAIL HANIC L Post & Beam 1 Rough In �,�, Gas Line ,6 ii eke Dampers ECTRICAL Service I (Oi 01 UG/Slab b I UG /b � Low Voltage Fir- larm air ►A S - SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin [ ] Please call for reinspection RE: [ ] Unable to inspect - no access Fire Supply Line ADA Approach /Sidewalk S V Date Inspector C� � (J EXt Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. 1�- CITY OF TIGARD BUILDING INSPECTION DIVISION 0_ � � d�93 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested 7 z 7-- AM PM BLD Location 1 3°1 ( 0 100 - Suite MEC Contact Person I� Cpl Ph '76 /` c / & PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear mi Framing 4. 7 giohiesflPelP9FigliirE u,_,..J7J,,, S- " � s All tier.,t - - Insulation Drywall Nailing A, _ rr .Art _ .i — C Firewall Fire Sprinkler 1 /S/e Y Fire Alarm Susp'd Ceiling Roof Misc: final PAS P FAIL PLUIG Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS FAIL os & Beam Rough In Gas Line Smoke Dampers F.: TART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Date Inspector Ext Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. : • CITY OF TIGARD BUILDING : INSPECTION DIVISION ( / - MST � `l , 24 -Hour Inspection Line: 639 -4175 Busigess,Line: 639 -4171 �' - - BUP ' Date Requested eF' ? Z AM PM BLD - `l Location { ,1 t © ! Gtr ' — Suite • MEC __ .. Contact Person 11 i l O.-' q _ :- i--.. Ph !:' L/ PLM Contractor Ph - SWR BUILDING) Tenant/Owner ELC Retaining Wall ELR C l Footing. � " . '2 � `>>J.!e=:: �f '2y S hI �:..,:�re4.: i.' ;� - - -�` : -•• <;;:4∎• - Foundation - • ' r 4�iyj • ,�;-•. i- ; xa , , 5`,.. IV ,, , ,,, q y! • ■ FPS . - Ftg Drain ,'_ / t."V :. c � k avP; ''.` -ti - s+",y�v :. ) '.,ci •': SGN Crawl Drain • - Inspection Notes: . • Slab • SIT Post & Beam . Ext Sheath /Shear - Int Sheath /Shear ' Framing / "j -- _ a`,......�,.., r r= �,..�r_r A.r .o. . Insulation Drywall Nailing i I A A /. mains4 /_rte,' 2,/4o —i/ - Firewall >^ . Fire Sprinkler A.e" r 1-c.42..a -- 6,'— c � /E- /,Q•!_ Fire Alarm f � Susp'd Ceiling 4 Roof r. - Misc: i , 9 PAS PART FAIL - � PLUMBING ; i � Post &Beam �� to 1 Under Slab Top Out f Water Service f / \ Vi .Ffr / AA 4 { • Sanitary Sewer • i /v j f / Rain Drains S / / '' Final -- / PASS_.P- -ART . FAIL d • I , MECHANICAL-) "Po & Beam . Rough In • , Gas Line °' `" Smoke Dampers Final CPASS� ART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage . Fire Alarm Final _ . PASS PART FAIL SITE - Backfill /Grading Sanitary Sewer Storm Drain '. s [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin -,• g, [] Please'call for reinspection RE: -Jr [ ] Unable to inspect - no access Fire Supply Line - ADA Approach /Sidewalk 7f Other Date - Inspector Ext, Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. • CITY OF TIGARD BUILDING INSPECTION DIVISION 9 -_ 0o/ 53 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 Date Requested AM PM BLD Location 1 ? ' /o 0 ) h 6 9- M Suite MEC Contact Person Ph ) / S Li / 7 ( PLM Contractor Ph ) SWR ILDIN Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: ---s--z) .1 z Slab SIT Post & Beam r 1 LX ` - b Q -� , 1 c / a Ext Sheath /Shear ''L -e'+ o Ina Sheath /Shear 41 '� 5r L°� ( � ��� ��� Framing ' ---- - ��c� Insulation '') t \ �� _ // yvx Drywall Nailing ` K (J�( Firewall (.0 (a ` Q b d Fire Sprinkler Fire Alarm Susp'd Ceiling (9 ,, Roof ' - A $1 ` , _-v 0� a-�-z Mis� �`� PASS PART 'AIL A 7.4 4'‘'k--- C? Y_t'`'L. - r 41, Lti - g :it III Post & Beam 1 . , Under Slab I Top Out Water Service L f ,) — C—ca k J' Q---v- S2 Sanitary Sewer Rai Drains -1-.1,...c-- PART 61t, ) i L.- S h°L -A--s '___/ " °__ iipStiAN �i 0,7 4 C J� � ,p� l Post & Beam Rough In () `J` } 1/4-1%--% s t „. - Gas Line 0 Sm a Dampers �� ` 2c, in ASS PART AIL ELECTRICAL Service p 1 Rough In ‘ � UG /Slab �) G�� Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin [ ] Please call for reinspection RE: [ ] Unable to inspect - no access Fire Supply Line ADA i� Approach /Sidewalk Date ' ) 1 L f 6 � Inspector " �' v — Ext ` Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. I CITY OF TIGARD BUILDING INSPECTION DIVISION MST 9I- l3 24 -Hour Inspection Line: 639 -4175 � Business Line: 639 -4171 • BUP Date Requested AM PM BLD Location ' 3 (o v /60 9- Suite MEC Contact Person p Ph 7) l� �� �{ PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Foundation Access FPS Ftg Drain � SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm c_/ Cc / �� ! !��-� / — Susp'd Ceiling Roof Misc: Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service • Sanitary Sewer Rain Drains Final ( PASS PART FAIL P eJ t�' � >°G) YL� lsj c P YID / YJ MECHANICAL re in, ��� C, P / Rough In Post & Beam Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm 'ART FAIL Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: / ] Unable to inspect - no access ADA Approach /Sidewalk Date F---/e4—o/ Inspector l f G� L�%JyLt�� Ext Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 92-de/93 24 -Hour Inspection Line: 639 -4175 Business Lin: 639 -4171 BUP /?'/ / Date Requested / �� / AM PM BLD Location l q O ,f Suite MEC Contact Pers GL4.4 Ph 7 / 3 V7 7 PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: / Foundation C� ,/J ' FPS Ftg Drain �- Crawl Drain Inspection Notes: /� � /j0.04�e SGN Slab SIT Post & Beam t Ext Sheath /Shear '7 S /^ / Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final � ♦ r Q cSs PASS PART FAIL v = PLUMBING Post & Beam Under Slab A/eGt/ idaj4rOdyn. Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL E - Service UG /Slab Low Voltage Fire Alarm F . PASS PART FAIL S Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: J Unable to inspect - no access ADA / / Approach /Sidewalk Date ON F - 6 f Inspector 47 , _ i A _ . Ext Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. • ' /141 . , .... . , ..,* r . - --------+-- Loc f� � / '' - ,- ' . r ili( � � ' E v , , Contact Person Ph , ' PLM; , Contractor Ph SWR BUILDIN -r Tenant/Owner ELC Retaining Wall ELR Footing Access: FPS Foundation Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath/Shear Int Sheath/Shear Framing Insulation Drywall Nailing / It' Firewall #�` / i. /t �i ri A Sprinkler / Fire Alarm Susp'd Ceiling A...r _/ / Roof / � ` J Misc: Final PASS PART FAIL •st & Beam / Under Slab � _dial / / /, / op a err Service Sanitary Sewer Rain I •ins F 0 i S PART FAIL rif)/ 1". CHAN "- Post & Beam - Rough In ( Gas eD I 6(2 Smoke Dampers kit. /" V Final PASS PART FAIL F e EEGTRI mow- . _____ � (� Service \" Rough In UG /Slab. Low Voltage Fire Alarm • Final PASS PART FAIL - BackfilUGrading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ • required before next inspection. Pay at City Hall, -13125 SW Hall Blvd Catch Basin [ ] Please call for reinspection RE: [ ] Unable to inspect - no access Fire Supply Line ADA / t ./ roach/Sidewalk Date Inspector Ext Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST ? "Q I 3 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 /3 7 / `---/ aa I `---/ BUP Date Requested 7 .-( / I AM PM K BLD Location I l Co 0 1 D( A Suite / / MEC Contact Person AA, SI/Ig.Q e Ph 101— ! Q CIS % PLM Contractor Ph SWR IL Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath/Shear t h /Shear 'I�L/ 7 k..„,,,,,■`N` -\---2Ae_ ,ji Q Insulation 1n t p Drywall Nailing ' V l a 1Y 2 6M,..,•". L../. • Firewall Fire Sprinkler Fire Alarm �l L (� Susp'd Ceiling 1 ' �� ? ('�/l •z-r/ \� G�� �✓� C Roof J Misc: .1. �, ` ' \, (i/'v\ n .e C_�- S -----. -..---,-----) Final PASS PART FAIL �� dz PL UMBING ) f ,e („A., Q/ b ___ rc, c C-c, Post & Beam ^I� To Out lab t, ?� �✓ ` �� ` ri1 j am ^ / fVl� , M P Water Service Z 0 ,1e ' Sanitary Sewer Rain Drains _A ghli Am.- PAO - , A _ Final PASS PART AIL t _ — . A ` A J' iftCHANICAL' t ` � Q ) Pos earn 1 �` �� . ough In ` , f \A.//4-91 vb . ine Smoke Dampers (d �1t. - `X Final ` — PASS PART FA C�3S ELECTRICAL 1 7 Service 1 ) �. ■■■ ~ ! _ ` it Rough b In „ .Q 3 (P V s vk SL UG /Slab v v��c Low Voltage `p Fire Alarm 4e (2 - 9-- 7- • Final PASS PART FAIL ' 4 _ - sr L a s SITE ll /Gradin 1 o 3, \ �� ` l� r4 , • Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Date c + t c ( Other �/ l Cl Inspector "� Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. 6/16/00 Activities for Case #: MST98 -00193 2:57:46 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes p MSTA005 Application received 5/7/98 DLH RECD BON 5/7/98 MSTA008 Permit Created 5/7/98 B DONE BON 5/7/98 MSTA010 Check for prcl. restrict. 5/7/98 B PASS BON 5/7/98 MSTA012 Plans routed to Plans Examiner 5/7/98 B SENT BON 5/7/98 MSTA030 Reviewed plans routed to DSTS 5/22/98 RDP APPR RDP 5/22/98 MSTA032 DST Post - Review Completed 5/26/98 GEO DONE GEO 5/26/98 MSTA155 Development conditions met BON 5/7/98 MSTA700 Erosion 844 -8444 BON 5/7/98 MSTA705 Footing lnsp 8/19/98 WDJ FAIL WDJ 8/19/98 USA approved 1. Hold downs for portal frame are not installed. 2. Remove organic materials from footings. 3. Foundation wall for portal frame must be a min. 8" thick. 4. #4 rebar in footing must extend a min of 10 feet beyond portal frame. MSTA706 Foundation Insp 8/19/98 WDJ FAIL WDJ 8/19/98 See footing inspection 08/19/98 MSTA710 Post/Beam Structural BON 5/7/98 MSTA711 Post/Beam Mechanical 9/25/98 LN PASS J *H 10/7/98 Lp2A MSTA717 PLM /Underfloor 9/25/98 LB PASS J *H 10/7/98 MSTA720 Mechanical lnsp 7/9/99 RB FAIL AKJ 7/11/99 see framing 7/9/99 MSTA722 Plumb Top Out 3/5/99 TLP FAIL TLP 3/5/99 NOT READY MSTA724 Electrical Rough In BON 5/7/98 MSTA725 Framing Insp 3/5/99 KS FAIL KBS 3/5/99 #-1- need to submit revised plan to bldg dept- over notched raters @ garage MSTA728 Low Voltage BON 5/7/98 MSTA740 Insulation Insp 8/2/99 RB PASS AKJ 8/2/99 MSTA790 Electrical Final BON 5/7/98 MSTA795 Mechanical Final BON 5/7/98 MSTA797 Plumb Final BON 5/7/98 MSTA799 Building Final BON 5/7/98 MSTA080 (F) Ready to issue 5/26/98 GEO PASS GEO 5/26/98 Owner must sign the application prior to issuance. MSTA092 (F) Issue combination permit 6/8/98 GEO PASS DST 6/8/98 Page 1 of 2 6/16/00 Activities for Case #: MST98 -00193 2:57:46 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA705 Footing Insp 8/20/98 WDJ PASS WDJ 8/20/98 MSTA706 Foundation lnsp 8/20/98 WDJ PASS WDJ 8/20/98 monopour MSTA710 Post/Beam Structural 9/25/98 LN PASS J *H 10/7/98 Tag 342890 MSTA735 Gas Line Insp 9/25/98 LN PASS J *H 10/7/98 Tag 342890 MSTA752 Rain drain lnsp 10/7/98 LB PASS J *H 10/7/98 MSTA097 Issue electric signature form 12/22/98 JMT RECD JT 12/22/98 owner not doing the work, selected NW Electric MSTA770 Misc. Inspection 12/24/98 CD FAIL CD 12/24/98 unable to inspect, no one home. MSTA723 Electrical Service 1/7/99 BRP PASS CD 1/7/99 MSTA724 Electrical Rough In 1/7/99 BRP PASS CD 1/7/99 lights over exterior doors not roughed in, will varify on final. MSTA725 Framing lnsp 7/11/99 7/11/99 7/9/99 RB FAIL No Hold AKJ 7/11/99 plm top out failed 3/5/99 TLP, no of plm done no insp noted for mech rough, connect exhaust fan 1) pressure block rafters at Ir /dr and mstr bdrm 2) over spanned 2x6 ceiling joists - ratrun and blocking req'd 3) collar ties req'd over mstr bath, min 1x4 at 4' ctrs 4) window adj to door out of mstr needs to be tempered 5) garage gusset rafter as per eng detail and nail ledger MSTA725 Framing Insp 7/13/99 7/13/99 7/12/99 RB PASS No Hold AKJ 7/13/99 window adj to door in master bdrm needs to be tempered, will check at bldg final MSTA726 Shear Wall Insp 7/13/99 7/13/99 7/12/99 RB PASS No Hold AKJ 7/13/99 MSTA720 Mechanical Insp 9/28/99 9/28/99 9/28/99 MS PASS No Hold AKJ 9/28/99 need to seal penetrations into house MSTA770 Misc. Inspection 2/18/00 2/18/00 2/18/00 JMT DONE No Hold JMT 2/18/00 research inspection request MSTA153 Expired by limitation 6 /7/00 HAP DONE No Hold AKJ 6 /7/00 Page 2 of 2