Loading...
Correspondence toi RECEIVE" cerby FEB 16 2011 February 10, 2011 �� CITY OF TIGARD fter k (A S' BUILDING DNISION Angie Cook West Hills Development 735 SW 158 Ave. Beaverton, OR 97006 RE: NEW SINGLE - FAMILY DWELLING Project Information Building Permit: MST2011 -00020 Construction Type: VB Address: y 0 5 SW 155 Terrace Occupancy Type: R-3 Area: 4481 Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2010 edition; the State of Oregon Residential Specialty Code (ORSC) 2008 edition and the Oregon Fire Code 2010 edition. The submitted plans have been reviewed and the following information is required prior to issuance of the permit. 1. Planning conditions of approval require two dwelling units per lot in the Brentwood Estates Subdivision. It appears that the area on the first floor identified as Guest room/ Office is intended to meet this requirement. Section R317 requires dwelling unit separation of 1 -hour minimum for wall and/or floor assemblies. Your plan shows other living space above the Accessory Dwelling Unit. This would require a 1 -hour rated assembly and all supporting construction of that assembly would require a 1 -hour rating per ORSC section 317.1.1. Please provide listed assemblies and details for the required wall and floor assemblies separating the dwelling units. 2. The definition of a dwelling unit from section R202 requires independent facilities for one or more persons, including permanent provisions for living, sleeping, eating, cooking, and sanitation. Please identify the permanent cooking provision and clarify how the requirement for a range hood required by section M1503 will be vented to the exterior of the building given the rated assemblies required by item # 1. 3. Please provide construction details for the chimneys. R106.1.1 4. Please clarify keynote 3 on sheets S -4 and S -5 and verify that the floor trusses have been designed according to the engineer's requirement in the keynote. Further, please provide construction details to clarify the strapping required by this keynote to the open -web joists proposed. R106.1.1 5. Sheet S -4 references detail 6 /SD3. There is no detail 6 on Sheet SD3. Please clarify. 8106.1.1 Note: Please provide an item by item response to the plan review comments above. When submitting revised drawings or additional information, please attach a copy of the City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Mark VanDomelen Building Official City of Tigard Direct (503)718 -2448 Fax (503)624 -3681 markv @tigard - or.gov February 15, 2011 To; Don Walters /Mark VanDomelen Building Officials City of Tigard Regarding: Plan review check sheet dated Feb. 10, 2011 PROJECT INFORMATION NSFD — Street Of Dreams House Permit #MST2011 -00020 Subdivision name: Brentwood Estates — Lot #12 Job address: 14501 SW 155 Terrace Response from plan review check sheet by line item. LINE ITEM #1 Response: Updated Plan with notes /keynotes and details. NEW SHEET AD -3 1 -hr wall/details, Affected sheets: 4,7,9,12, AD -3 LINE ITEM #2 Response: Added Range w/ hood to A.D.U. (guest rm. /office) — we are adding a suspended clg. Or furred down ceiling to accommodate the vent ductwork needed for the range hood. To vent through the rear exterior wall of the A.D.U. LINE ITEM #3 Response: Not Applicable. — We are using all gas fireplaces with dir. vent or `B' vent chase chimneys. LINE ITEM #4 Response (a): Updated Floor framing Layout Sheet FLR -2B to shown noted Floor trusses with Eng. point loads on them. See new floor truss Calc's provided. Response (b): Provided construction details for strapping — See Eng. Detail 9 on sheet `SD3'. LINE ITEM #5 Response: Updated Plan to show detail 6 /SD3 correctly. If you have any questions please call me at 503- 624 -9251 Thank you, Dave Rasmussen Arbor Custom Homes/West Hills Development 503- 726 -7046 Fax 503- 641 -7661 I. ' if• Dwight Mason Structural Design, Inc. ✓,�/4 —�' < ,fi ar P.O Box 683 Beavercreek, Oregon 97004 (503) 632. -8863 P ` 6' O', STRUCTURAL CALCULATION PACKAGE DMSD JOB # 11 -002 ,��,`' m e ot" °fdN ' s. 7 23OC't {r ARBOR CUSTOM HOMES STREET OF DREAMS HOME BRENTWOOD ESTATES LOT #12 TIGARD, OREGON 12/10/10 The attached calculation sheets 1 through 61 verify the structural adequacy of the above referenced project shown on drawings S1 through SD3 dated February 1, 2010. The design is based on the requirements of the 2010 Oregon Structural Specialty Code. This engineering package is only valid for the above referenced structure at the location noted above with a original stamp and signature in blue ink.