Loading...
Permit CITY OF TIGARD ELECTRICAL PERMIT • COMMUNITY DEVELOPMENT Permit #: ELC2011 -00099 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 02/18/2011 Parcel: 2S112AD00500 Jurisdiction: Tigard Site address: 14650 SW 72ND AVE Project: Rogers Machinery Subdivision: Lot: 0 Project Description: Relocate point of common coupling (grid tie) of a previously installed solar array as requested by PGE. Contractor: NO ARC ELECTRIC INC Owner: ROGERS MACHINERY CO INC 4029 NE 16TH CT PO BOX 230429 GRESHAM, OR 97030 PORTLAND, OR 97281 PHONE: 503 - 799 -5430 PHONE: FAX: 503 - 907 -5435 FEES Quantity Description Date Amount 1 ea Services or Feeders - 201 to 02/18/2011 $133.56 Specifics: 400 amps 1 ea 12% State Surcharge - 02/18/2011 $16.03 Type of Use: COM Electrical Class of Work: ALT 1 ea Plan Review Electricial 02/18/2011 $33.39 Type of Const: Occupancy Grp: Total $182.98 Required Items and Reports (Conditions) This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952- 001 -0010 through 0 :•- -2- 001 -0090. You m- o. air' a copy o ect questions to OUNC by calling 50 •87 or 1.332.2 . Issued _ = Permittee Signature: ���_ OWNER INSTALLATION ONLY �� The installation is being made on property I own which is not intended for sale, lease or rent. OWNER'S SIGNATURE Date: CONTRACTOR INSTALLATION ONLY SIGNATURE OF SUPR. ELEC' Date: LICENSE NO. Call 503.639.4175 by 7:00 a.m. for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. 9. Electrical Permit Applicati A ,CEIVED .. FOR OFFICE USE ONLY City of Tigard Received qq n / , �/L. b /J Permit No.: �61 / pQ 7 I V r r 1 Date /B 40 4. 40 4. � / 13125 SW Hall Blvd., Tigard, OR 9722 _ Plan Review., ' �, LIV -1 1 C Phone: 503.639.4171 Fax: 503.598.1960 Date/By: L { 8 �) Other Permit: I' 1 c; A R D Inspection Line: 503.639 CITY OF TIGARD Date Ready /By: Surfs. El See Page 2 for Internet: www.tigard- or.gov BIM .DING DIVISION / N / .er°Ls ire,c Supplemental Information TyPE OF WORK PLAN REVIEW 1=I New construction A ddition /alteration /replacement Please check all that apply (submit 2 sets of plans �v /items checked below): ❑ Service or feeder 400 amps or more ❑ Building over three stories ❑ Demolition ❑ Other: where the available fault current ❑ Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or ❑ Floating buildings. .! less to ground, or exceeds 14,000 CI Commercial-use agricultural 111 1 - and 2- family dwelling P Commercial /industrial ❑ Accessory building amps for all other installations. buildings. ❑ Multi - family ❑ Master builder ❑ Other: ❑ Fire pump ❑ Installation of 75 KVA or JOB SITE INFORMATION AND LOCATION ❑ Emergency system. larger separately derived system. ❑ Addition of new motor load of ❑ "A ", "E ", "1 -2 ", "1 -3 ", Job no.: Job site address: // //�� e 7 ' N4 A 10OHP or more. occupancy. 6.v J 7 Z. A tie. ❑ Six or more residential units. ❑ Recreational vehicle parks. City/State /ZIP: ❑ Health -care facilities. ❑ Supply voltage for more than - t a� r 4 7 2 g , �J I ❑ Hazardous locations. 600 volts nominal. Suite /bldg. /apt. no.: Project name: P r - /1 / / AC t et e ❑ Service or feeder 600 amps or more. 111 FEE SCHEDULE Cross street/directions to job site: Description I Qty. I Fee. I Total New residential single- or multi - family dwelling unit. Includes attached garage. Subdivision: Lot no.: 1,000 sq. ft. or less 168.54 4 Ea. add'I 500 sq. ft. or portion 33.92 1 Tax map /parcel no.: Limited energy, residential DESCRIPTION OF WORK (with above sq. ft.) 67.84 2 A 11 G T Limited energy, multi - family ca R e 10 fie, Sear W cre..1 0 C O residential (with above sq. ft.) 67.84 2 1 ` t Services or feeders installation, alteration, and /or relocation 1neVJ Se r V I L>° l () C t O A 200 amps or less 100.70 2 ❑ PROPERTY OWNER ❑ TENANT 201 amps to 400 amps i 133.56 /33.52 Name: Q o 7 er s M t vt e , r � / D , /W.-, 401 amps to 600 amps 200.34 2 ` ` l i -.601 amps to 1,000 amps 301.04 2 Address: ' sd SW 7 7. N1 A v.e._ Over 1,000 amps or volts 552.26 2 City/State /ZIP: --rt 1 a rd OR a '1 28 I Temporary services or feeders installation, alteration, and /or relocation Phone: ( 639 _ D 8 O 8 Fax: ( ) 200 amps or less 59.36 1 Owner installation: This installation is being made on property that I own which is not 201 amps to 400 amps 125.08 2 intended for sale, lease, rent, or exchange, according to ORS 447, 449, 670, and 701. 401 amps to 599 amps 168.54 2 Branch circuits - new, alteration, or extension, per panel Owner signature: Date: A. Fee for branch circuits with APPLICANT ❑ CONTACT PERSON above service or feeder fee, 7.42 2 each branch circuit Business name: S Q I ar t �� /A. �� A R G E` .eG r , � B Fee for branch circuits Contact name: BU I _ !!! - 6 without branch service r or feeder fee, 56.18 2 Cl � first branch circuit Address: 9o5 Nye/ Corpora 1-e_ b{. Each add'I branch circuit 7.42 2 Miscellaneous (service or feeder not included) City/State /ZIP: f. t ) i - A ex l a R R 70 4, 9 d Each manufactured or modular 67.84 2 dwelling, service and/or feeder Phone: (56 3 ._ 7 67 1 I Fax: : ( ) Reconnect only 67.84 2 E -mail: )JJ .1 X( s (3/4 r /d /7 , Co"-, Pump or irrigation circle 67.84 2 ON TRACTOR Sign or outline lighting 67.84 2 C r � 1 Signal circuit(s) or limited - Business name: �J v i0..., p„ I O Ill /AL AR G I GT i/' a G energy panel, alteration, or Address: g s-- //YV CJU re o f ct l ,P b r . /� extension. Describe: Page 2 2 City/State /ZIP: 4-d v h4 O. ( € __ d R L 7D1o0 Each additional inspection over allowable in any of the above / / Per inspection 66.25 Phone: (5 30 7 - 7 IA:, e0 I Fax: ( ) Investigation per g p hou ( / (1 hr min ) 66.25 CCB Lice g 7 3 I Electrical Lic.: 26, / 2 Suprv. Lic.: x,/532 , Industrial plant per hour 78.18 / !!! ELECTRICAL PERMIT FEES Suprv. Electrician signature, required: �w ..4... /O 3 Subtotal: / 33. S( �j // Plan review (25% of permit fee): .'>3 ( 5. 3? p Print name: lO Date: Z �� _ �� OX. State surcharge (12% of permit fee): /1p.03 Authorized signature: ` r i. Z S TOTAL PERMIT FEE: � _ Mr/ This permit application expires if a permit is not obtained within 180 Print name: ff ,, , v az. Date: 2 /4 - // days after it has been accepted as complette. /' g Number of inspections allowed per permit. f / S [ t: \Building�Permits�ELC- PermitApp.doc 10!01 /09 440- 4615T(I l /OS /COM/WEB e Electrical Permit Application - City of Tigard Page 2 - Supplemental Information LIMITED ENERGY PERMIT FEES: • RESIDENTIAL WORK ONLY: Fee for all residential systems combined $67.84 Check Type of Work Involved: n Audio and Stereo Systems* ❑ Burglar Alarm • F-7 Garage Door Opener* n Heating, Ventilation and Air Conditioning System* n Vacuum Systems* n Other: COMMERCIAL WORK ONLY: Fee for each commercial $67.84 system (SEE OAR 918 309 - 0000) Check Type of Work Involved: n Audio and Stereo Systems n Boiler Controls n Clock Systems ❑ Data Telecommunication Installation n Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* n Medical n Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling n Other Total number of commercial systems: *No licenses are required. Licenses are required for all other installations 1 \Building\Permits\ELC- PermitApp doc 10/01/09 151E1 1 Sr1LU11lEPI iEALI LIL uwU IN •• •• •• • • • • • NOTES: • • • • • • • • • • • • • • A REFER TO ELECTRICAL SCHEMATICS FOR MORE DETAILED • • • • • • • • • • • • INFORMATION ••• • • •• • • • • • • • • • • • • • • • ••• • • •• • •• RECEIVED • — —• • • • • • • • I •• • • • •• • •• FEB 1 "11 • • • • • • • • • • • • ARRAYC OF TIGARD ARMV ARRAYS ARRAN' INGS OF • • • • • • S •1MYB• S • • • • • • I M MO DU L E S 1 MO DUS SF 9 STRINGS BTRING S 9 1 UL MOD S 11 MODULES 11 NOWlES SMOWL I S MOOULES 1f MODULES ••• •••, • • •• •• BUILDING DIVISION • • • 1 • • • • • • • • • - 0 — • • -•—•— • • • • ••• ••• •• • • • • • • : 4 , , ,,,,, ■ ,,,, : 1 470 • • ■ COMBINER BOX A COMBINER BOX B COMBINER BOX A COMBINER BOX B COMBINER BOX C SN P ► ► ► __ I �‘ M SOLECTRW RENEWABLE SWECTRIA RENEWABLE SOLECTRIA RENEWABLE SOLE.... RENEWABLE oC PVMS01(W INVERTER PV413KW INVERTER PV418KW INVERTER PJI -15KW INVERTER ` S 0 7 4 cl.. --:-._-, 0 l NATION I 1 I ROGERS • ROGE RS 14650 SW 72nd Ave. AC COMBINER PANEL ilit)i Portland, Oregon MACHINERY 97224 ei COMPANY, INC. • IN.- • — GENERATION METER ► - REV DESCRIPTION BY DATE FUSED AC DISCONNECT SOLAR NATION CONFIDENTIALITY THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SOLAR NATION. ,,,,,,EL w THIS DOCUMENT IS RECEIVED IN CONFIDENCE AND ITS CONTENTS SHALL NOT BE REPRODUCED, USED, OR DISCLOSED TO ANYONE WITHOUT THE PRIOR WRITTEN PERMISSION OF SOLAR NATION. TRANSFORMERS 100A 1 DRAWN BY TK CHECKED BY JP ISSUE DATE 02/17/11 • PANEL C OFFICE COPY DRAWING TITLE 300A I - .BOV, 1200A SUS TRANSFORMER HEAT/COOLING ••■ BBA SYSTEM MACHINE DOD 1 CITY OF TIGARD F LOW Approved ( NOT IN USE 1 PGE NETME�ER Conditionally Approved . ( ): DIAGRAM AM NO FUSES 1 MMBSBt7B For only the work as described in: Q ' PERMIT NO. l-C Z.a L`- 000 ci EXISTING ( ): j .... UTILITY TRANSFORMER I See Letter to: Follow ( ) �J Address: A /� - • J d I, , A9f, 1 :::e -- .5oZz.--/1 ce..4.1 . Co /21