Loading...
Permit 1 111111 - CITY OF TIGARD MECHANICAL PERMIT COMMUNITY DEVELOPMENT PERMIT #: MEC2008 -00012 TIGARD 13125 SW Hall Blvd., Tigard, OR 97223 503.639.4171 DATE ISSUED: 1/9/2008 PARCEL: 2S114AA-00200 SITE ADDRESS: 16285 SW 85TH AVE 405 ZONING: I -P SUBDIVISION: DURHAM HALL BUSINESS PARK LOT: JURISDICTION: TIG PROJECT: DURHAM HALL SPEC SPACE Project Description: Replace unit heater with same size and capacity. $1875.00 CLASS OF WORK: ALT FLOOR FURN: EVAP COOLERS: TYPE OF USE: UNIT HEATERS: 1 VENT FANS: OCCUPANCY GRP: B VENTS W/O APPL: VENT SYSTEMS: STORIES: BOILERS /COMPRESSORS HOODS: FUEL TYPES 0 - 3 HP: DOMES. INCIN: NAT 3 - 15 HP: COMML. INCIN: MAX INPUT: BTU 15 - 30 HP: FIRE DAMPERS ?: 30 - 50 HP: REPAIR UNITS: GAS PRESSURE: 50 + HP: WOODSTOVES: FURN < 100K BTU: AIR HANDLING UNITS CLO DRYERS: FURN > =100K BTU: <= 10000 cfm: OTHER UNITS: > 10000 cfm: GAS OUTLETS: 1 Owner: FEES BIRKEMEIER, BRENT T /JANET D TRS Description Date Amount BY THE BIRKEMEIER FAMILY TRUST 10573 SW NAEVE ST [MECH] Permit Fee 1/9/2008 $72.50 TIGARD, OR 97224 [TAX] 12% State Surch 1/9/2008 $8.70 Phone: Total $81.20 Contractor: WILLAMETTE HVAC SERVICE PO BOX 23334 TIGARD, OR 97281 REQUIRED ITEMS AND REPORTS Contact #: PRI 503- 628 -6841 FAX 503- 848 -2597 Reg #: LIC 56951 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted in the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain copies of these rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344. Issued By: Permittee Signature: fi Call 503.639.4175 by 7:00 a.m. for inspections that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit Application 1(M 12 011 k 1 1' 1 11 v 1 1 City of Tigard I Datem . C/ III 13125 SW Hall Blvd., , R 2 DatelBy: � � � 7 f) 05 �'tNo. ��`� �� Plan R Phone: 503.639.4171 Fax: a Other Permit: D telly: 1 I ` ., ,. I , Inspection Line: 503.639.4175 ' Date ReadyBy: pis: ® See Page 2 for Internet www.tigard or.gov I,,,1 0 Ft 2008 Notified/Method: ' Supplemental Information ` I � : ,, �t RKT 3 uA RD fi COMMERCIAL FEE* SCHEDULE — USE CHECKLIST � ❑ New construction 1A tid uf W' i la ti (iN Mechanical permit fees* are based on the vial ►e of the work performed. Indicate the value (ram the wares dollar) of all ❑ Demolition ❑ Other: mechanical materials, equipmentllabor, overhead, an ■ profit. CATEGORY OF CONSTRUCTION V fl tie: $ $1,875.00 RESIDENTIAL i 4 ' +-:- ,4 , MS* ❑ l- and 2- family dwelling ® Commercial/industrial ❑ Accessory building El Multi-family 0 Master builder For special information use checklist. ❑ Other: Description 1 Qty. 1 Ea. I Total JOB SITE INFORMATION AND LOCATION Heating/cooling lob site address: e c Air conditioning or heat pump l' $$ " (// 5 �� (requires site plan showing placement) 14.00 City/State/ZIP: Tigard OR 97281 Furnace 100,000 BTU (ducts/vents) 14.00 Suite /bldgJapt. no.: 405 Project name: Durham Hall Furnace 100,000+ BTU (ducts/vents) 17.90 Gas heat pump 14.00 Cross sheet/directions to job site: Duct work 14.00 Hydronic hot water system 14.00 Residential boiler (radiator or hydronic) 14.00 Unit beaters (fuel -type, not electric), in -wall, in -duct, suspended, etc. 10.00 Subdivision: Lot no.: Flue/vent for any of above 10.00 Other: 10.00 Tax map /parcel no.: Other fuel appliances DE. [TIM Of WORK. Water heater 10.00 Replace existing unit heater with same size and capacity Gas fireplace 10.00 7 CX )0 f 1(.1 Flue vent for water heater or gas . fireplace 10.00 Log lighter (gas) 10.00 Wood/pellet stove 10.00 Wood fireplace/insert 10.00 ❑ PROPERTY OWNER I ❑ TENANT Chimney/liner/fiue/vent nt 10.00 Other 10.00 Name: Environmental exhaust and ventilation Range hood/other kitchen Address: equipment 10.00 City/State/LIP: Clothes dryer exhaust 10.00 Single -duct exhaust (bathrooms, Phone: ( ) Fax: ( ) toilet compartments, utility rooms) 6.80 a APPLICANT 0 CONTACT PERSON Attic/crawlspace fans 10.00 Business name: Other: 10.00 Fuel piping Contact name: $5.40 for first four; $1.00 for each additional Address: Furnace, etc. Gas heat pump City/State/ZIP: Wall/suspended/tmit heater Phone: ( ) I ax ) Water heater Fireplace E -mail: Range CONTRACTOR Barbecue Business name: Willamette HVAC Clothes dryer (gas) Other: Address: PO Box 23334 MECHANICAL PERMIT FEES* City/State/ZIP: Tigard Or 97281 Subtotal Minimum permit fee ($72.50) +fa Phone: (503) 628.6841 I Fax: (503) 848.2597 Plan review (25% of permit fee) CCB lie.: 56951 State surcharge (12% of permit fee) c, J � y TOTAL PERMIT FEE Authorized signature: n / ,'/{l�s'yjn 'Ills permit appticaUoa expires if a permit is not obtained within 180 days after it has been accepted as complete_ I T._♦ _ �_. 1I. 1/ 1 I Ts - a... 1 10 MO I • Fes. mnflvvtnlnm. co4 Mr Tri- rramty RniLiinn Tnrinctn. Cnr.nro Rnarrl 83 SW Y S � a r o v te' Attachment is to 4X14 joist lag bolt and a angle iron typical v N s threaded rod / S,p0 . Johnson Air Products Johnson Air Products 2220 SE Ninth Ave. ? _ N 21 13 Delta Waters Road Portland , OR 97214 7 Medford, OR 97504 v /N�D1NE wookusouirion Unit Heaters Part # Description BTU In BTU Out Vent Weight List —_,., " ' � UH5OSP 50M BTU SPARK IGNITION UNIT HEATER 50,000 40,000 4" 72 Lbs. S995.60 UH75SP 75M BTU SPARK IGNITION UNITITER 75,000 60,000 5" 102 Lbs. $1,059.40 UH100SP 100M BTU SPARK IGNITION UNIT HEATER 100,000 80,000 6" 116 Lbs. $1,303.40 UH125SP 125M BTU SPARK IGNITION UNIT HEATER 125,000 100,000 6" 152 Lbs. $1,421.00 =�1 UH1 50SP 1 50M BTU SPARK IGNITION UNIT HEATER 150,000 120,000 7" 162 Lbs. 51,494.80 ;, UH175SP 175M BTU SPARK IGNITION UNIT HEATER 175,000 140,000 7" 169 Lbs. $1,697.40 UH200SP 200M BTU SPARK IGNITION UNIT HEATER 200,000 160,000 7" 231 Lbs. $1,847.60 UH250SP 250M BTU SPARK IGNITION UNIT HEATER 250,000 200,000 8" 231 Lbs. $2,037.60 UH300SP 300M BTU SPARK IGNITION UNIT HEATER 300,000 240,000 9" 231 Lbs. $2,395.40 UH400SP 400M BTU SPARK IGNITION UNIT HEATER 400,000 320,000 10" 410 Lbs. $2,999.60 Standard Features • A"— �c� • CSA certification for use in the US and Canada ,� -N —•+ �E—•+ • 80% thermally efficient I 1 1 • Blocked vent safety switch i I 1 NTPIPE 1 1 K w i — KT •- i 1 I • 20 gauge aluminized steel cabinet "1 _m— 0 • 1 1 5 V control step down transformer with 24 V gas "" l - T. controls • Aluminized steel heat exchanger t Ji • Aluminized steel burner with stainless steel separator I , strip E B • Certified to 0.5" W.C. external static pressure f 11' • Single stage standing pilot control system for — , operation on natural gas a ar Be 5i • High limit safety control • Control terminal board L D(OPENINO ►I 4 LL • Adjustable motor sheaves on blower models -- • Totally enclosed fan /blower motors L BARK DISTANCE TO WALE) Dimension Model Number 9yrribd PD 30 PD 50 PD 75 PD 100 PD 125 PD 150 PD 175 PD 200 PD 250 PD 300 PD 350 PD 400 ' A 12-7/8 17 -1/4 17 -1/4 19-1/4 19-1/4 21 23-12 25.5/8 25 -5/8 28-5/8 33-5/8 40 B 24-1/4 24-1/4 28-3/4 28-3/4 35-1/4 35-1/4 35-1/4 40-1/4 40-1/4 40-1/4 40-1/4 40-1/4 C 14-3/4 14-3/4 20 20 22 22 22 25 25 25 25 25 D 10.7/16 14 -13/16 14 -13/16 16 -13/16 16 -13/16 18 -9/16 21 -1/16 23-3/16 23- 3/16 26-3/16 31 -3/16 37 -12 E 13 13 16 16 20 20 20 24 24 24 24 24 F 9-1/4 9-1/4 11 11 12 12 12 13-1/2 13-1/2 14 - - G 2 2 2 -3/4 2 -3/4 3-5/8 3-5/8 3-5/8 4-38 4-3/8 4-3/8 4-1/4 41/4 H 9-1/4 13-5/8 13.5/8 15-5/8 15-5/8 17 -3/8 19-7/8 22 22 25 30 36-3/8 J® 3 4 5 6 6 7 7 7 8 9 10 10 K (Mounting 3/8-16 3/8-16 3/8-16 3/8-16 3/8-16 3/8-16 3/8-16 3/8-16 3/8.16 3/8-16 3/8-16 3/8-16 Holes) co L ® 28-1/4 28-1/4 36 36 36-1/2 37 -1/8 37 -1/8 40-7/8 41 42 -1/4 42 -1/4 47 -1/4 W - - - - - - - - - - 5 5 X - - - - - - - - - - 16 16 AA 5 5 6-1/4 6-1/4 8 8 8 9 9 9 9 9 BB 6-1/4 6-1/4 6-1/2 6-1/2 7 -1/4 7 -1/4 7 -1/4 7 -1/4 7 -1/4 7 -1/4 7 -1/4 7 -1/4 EE 22 -1/4 22 -1/4 29 29 30.12 30-12 30-1/2 32 -7/8 32 -7/8 32 -7/8 32 -7/8 32 -7/8 U. 19-12 20-1/8 30 30 30 31 -1/8 31 -1/8 34-78 34-7/8 36-1/4 35-1/2 40-1/2 Gas Cnnedlorts (g) 12 1/2 1/2 1/2 12 12 12 1/2 1/2 12 3/4 3/4 Fan Diameter 9 12 12 14 14 16 18 20 20 22 22 24 Approx. Weight 58# 72# 102# 116# 152# 162# 169# 231# 231# 261# 330# 410# ® Do not use propeller units with duct work ® Diameter of round vent pipe to it oval opening. ® PD 30 through PD 300 — 2 holes (and the level hanging adjustment feature). PD 360 through PD 40f1— 4 holes. (Listed is the hole diameter and threads per inch to accept threaded rod) ® Dimension equals overall plus 8'. (5) Fa natural gas; may vary depending on control availability. PORTLAND- 503 - 234 - 5071 WWW. JOHNSONAIR. COM MEDFORD: 541 - 772 24.08.06 Page: 162