Loading...
Permit ' CITY OF TIGARD PERMIT #: BUP2000 -00387 ,a DEVELOPMENT SERVICES DATE ISSUED: 9/14/00 ,�- '- BUILDING PERMIT 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 SITE ADDRESS: 16285 SW 85TH AVE BLDG - 400*** PARCEL: 2S114AA -00200 SUBDIVISION: DURHAM HALL BUSINESS PARK ZONING: I -P BLOCK: LOT: JURISDICTION: TIG REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: OTR FIRST: sf N: S: E: W: TYPE OF USE: COM SECOND: sf PROJECT OPENINGS? TYPE OF CONST: UNK : sf N: S: E: W: OCCUPANCY GRP: UNK TOTAL AREA: 0.00 sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: BASEMENT: sf AREA SEP. RATED: STOR: HT: ft GARAGE: sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: SMOK DET: DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : HNDICP ACC: BEDRMS: BATHS: IMP SURFACE: PRO CORR: PARKING: VALUE: $ 16,316.00 Remarks: Commercial re -roof, existing roof covering to be removed. Owner: Contractor: BIRKEMEIER, BRENT T /JANET D TR SNYDER ROOFING OF OREGON LLC BY THE BIRKEMEIER FAMILY TRUST PO BOX 23819 10573 SW NAEVE ST TIGARD, OR 97281 TIRonD, OR 97224 Phone: 620 -5252 Reg #: LIC 135987 FEES REQUIRED INSPECTIONS Type By Date Amount Receipt Dryrot after tear -off PRMT CTR 9/14/00 $235.90 27200000000 Final Inspection 5PCT CTR 9/14/00 $18.87 27200000000 Total $254.77 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Ce -r. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -1987. You may obtain a cop of these rules or direct questions to OUNC by calling (503) 246 -1987. Pemiitee Signa . e: A� Issu B ; • 1 ; , . /• , ! ,i Call 639 -4175 by 7 p.m. for an inspection the next business day J i f I w: X r -M - 1 ° t } 4,1 t t .- r :.- _. �e , 14, t ' , ? ' di' ' 4r + # f;:. , i' .� f :' k a v ∎ t ft ',1,, yF� 3 t P T . a ' `q.' �� r d 7 : a -'i t � .� � � ' r V �t?•� % Fa � "r y ,�,� _ r r ,i N 4 v � - -,� , r f :� , Y v ` ..__ 1,1,4,0,4,..,-:‘,..,,:::,? r . l ' a CARD `i f L ` I t x' s �j � - 1 i b r ' fK 13125'S HALL BLVD. � az .:.4..":"',.,? .f ' r 3 �, . TIGARD OR 97223 RE- ROOFING PERMIT APPLICATION' �,.,_. . ' d "F k ' V --403 639 -4171 X304 Da e,to PE: -- ., ;' Date to DS --'�- F- 503 -698 -1960 Permit #: C, 7 p illegible pp ill, not be accepted Called Incomplete or ille ible a Iications w . � ,, Na .e o I-velopmentJ:usine s ( " 4r C7 'il 10 „- i1 j 0 U P4 �1.1V11 ads � %l�Fr °r7 §� ,.,.i iJ, � }a- , x st k"-sr Street Ad• re s i. h✓ SO # Please fill out applicable section and d attach copy of roofing Job Site , i I '\� 00 specifications. Bldg Cit / ate ZIP ListedAssembl Circle; &�Co ��� ''; g i P-/ 471/3 A. �� � . Nam 1. Specification #: j y ova. (con qt.", (I) re s Applicant Maird A .3 2. Manufacturer: �[ ` I ' / Zip Phone *3a UL Classification: CLi + /5 (; X 17 2 I fit, - 51.5 Roofing Name N ` v 1 L �� �` ,, _ _ Listed UL Building M Directory Page #: tilt Contractor 7 G e�('J� OR (Prior to issuance Mailing Addjss *3b Warnock Hersey : applicant must provide a copy of City /State 9VVICa- Zip Listed Warnock Hersey Directory Page #: all contractor *COPY OF ASSEMBLY REQUIRED licenses if Phone # Fax # expired in COT 6/0- 5 I (QM,' ?,$b B. ICBO Research #: database) State Corytr.C. r B... # EX 3 . Date IV /SX) DATED: , - a nett NFORMA„fON` :' ,, , f.::, " :„ ' ry `< C. SPECIAL PURPOSE ROOFING: WOOD SHAKES Building - Type Of Use: (circle one) (review required by plans examiner) SF SFA COM MF Building - Type of Construction: VALUATION OF PROJECT $ �� !�, 6 7 sq. ft. of roof area t- — Existing Deck Type: Permit fee based on valuation* Combustible (X) Non - Combustible ( ) * see chart on back $ .ESIDENTIAL' ONLYi • Class of WorlctAlteration E_ ` City use only WACO : '' Igef ,_ ❑ REPAIR (MAJOR) (review required by plans examiner) (BUILD) (UBUILD) , Permit required ONLY when spaced sheathing is covered by solid sheathing. Changes to roof line require Building Permit 8% State Surcharge $ Application. City use only: WACO. . .., : SUBMIT TWO (2) SETS OF PLANS SPECIFYING. (TAX) (UTAX) � �, ': . :.. :.;_ .�, A. Roof area & nearest street. *Required for major repairs of Residential i B. Attic vents - Provide 1 sq. ft. for each 150 sq. ft. of attic or "C" above * 65% Plan Review $ space. Vents shall be located in the upper 1/3 of the roof. t :i 9 5 s . , r10 / . Provide 1 sq. ft. for each 300 sq. ft. when eave & attic � f st i �1, F a ,L venting is provided. TOTAL $ �� �1 4' a(z < I acknowledge that I have read this application and that the '` information given is correct; that I am the owner or authorized D- scribe work to be done: (check appropriate box) agent of the owner, and that the plans (if applicable) are in v r, ROOF (circle A ,B or C) co plia ce with Oregon State law. : xisting built -up roof covering to be REMOVED and deck repaired - Si gna it of Owner /Agent Date B. Existing built -up roof covering to REMAIN: note applicant must submit an engineer's review of the roof structural 0 CID elements. Review shall bear the seal (or stamp) of the architect or engineer licensed in Oregon. Contact Person Name Tele one C. Asphalt or wood shingle /shake � ' (PROCEED TO STEP 2) 14I 1, \)E-r �C (yn" a I - 36 ( J I:dsts\forms\roof.res.doc 8/26/99 y . w SUPPLEMENTAL BUILDING PERMIT It PERMIT APPLICATION =— • REROOFING a. • This form must be filled out if you are reroofing a structure -- _ _ = r = = ' - L o c a t i o n of work ' - - 1 , - A , Applicants Name •N� O (j.•-)C �� . U ,0 Liz_ - - Description of work: • Roof recovering . .Tear off # of squares: C u Valuation of work:$ g' �S Description of existing work: ' • Deck type: Insulation type / p YP _ - Condition of insulation: wet • dry damp • N A . 4 .. # of roof coverings # of plies: 1 1 Y---- Roof surfacing material CAP 5� �T Were cores taken: yes no . Specification for preparing roof surface: e \ (X� 1t� -=\ � --. • n for new roof covering: -Type A Typ B -- - Type C - • _ - Specification 9 UL_Classification #: IC8O research report #: - UBC fire retardant roof composition: Base sheet 28 - - - • > -�_ Ply sheets • 1 � Y - � - - _ -- . • a Surfacing Signature: A - - - -- _ tote: Inspection of roof deck and final installation is required. Cali 796 -7303 to arrange for =- =_ nspection. This form to be filed withthe Building Permit after final approval of the work_ • �., o ' t AVyR;R'a�`�k :4+.u.Jwd-V ' I BUILDING TECH F�DOKSTORE, INC. l ,tH e i 8020 SW Cirrus Drive • Ben OR 97008 -5986 7 - 77- - - 7 --------------- ' ' ''"" '" -'" "' T' 1 1 503 641 -8020. 1 -800 -ASK 1100K • FAX 503 641 -0770 � a 1 Y S a' ¢�Ft 3 � r �T r'V$ y . k� EL ry ! } a u p . 5 1 4 �'. e 0,1,1'1'1'; R ' h } sy P ■ Igte$r , el 30tT+ -a, }1 _ � r t � 41 t 4 ,� Contai j , .� Listingstand Classi � {: m : , y , � €�dz'�{ ''$`jr. '�=; i , ¢ S ( ' r , In effiect,as of Dece a ®. ; 1 1998. , :, � �€ - - t. , Pleas e r l n f ormati • . �� S � ` , ,,,,,:,,,,„„, �"� � Ir '1 par agraph 2 • . • � d , '" ; 14,- , , + "f d qe t+' 4 6.,\,:)..,-,.,1,„ �: _ j j r � $: 4 , i i ,, , ,i,i ., er , , „ , , . .. , . 1^ r:.` 1 b 1 b4 "4 Yom{ ,, M y, iF � T Y t t- f - '. q Yf ��& a4 u a L. o R 3 ��, t �, x � I ,;',,, � � ,''. fir � 1 r" ^-� ,. 4 - ! •; i , , . , Y n r � � ,, ` i s ones Inc. ic,..ttt,i,,,,,,Iftr, { ?� . ` iZ , I t 1 ' i'' `' ," ) I 4, iF>rl k Y Y „ r`?' -.F1‘ '''' ":1411'1''."4114t- I . , , Mil lh , I , ) i n ` , , ,* . ,,,;,,,,, , i t ,* ' I , ; ,h , i t., ‘,_..., ,,,,, 11,, ,,, , i ' � �., q,`' =.! d„_,1,'� .� €n„._•�4t,'" :d's. rv.a�'.�S.f� „,. .�.'' a,.m X7 3. �,,, Ll'A �FF. , i .>.. Sm 1. , 6::r _ha � °i....w..l4;,rd,'kPf. • yk d f - 1999 Roofing Materials and Systems Directory A . • ROOF COVERING MATERIALS (TEVT) ROOF COVERING MATERIALS (TEVT) 141 ' ROOFING SYSTEMS (TGFU) — Continued ROOFING SYSTEMS (TGFU) Continued 29. Deck: NC Incline: 1/4 "GAFGLAS Flashing" or "Ruberoid" may be used for flashing in any Foam: "Poly -Iso" or "Poly -Iso Special" with "Polyfoam 251" or "Polyfoam A, B or C systems listed below. 303 ", 1 in. min. When "perlite" is referenced, this includes "GAFTEMP PERMALIT Base Coat: One or two applications "Gacoflex UB- 7050 ", applied at 1 other UL Classified perlite insulation. gal /sq /application or three applications, applied 1 -1/4 gal /sq /application Crushed stone or slag are suitable alternates for gravel in any of I (16 -32 dry mils). B or C systems listed. Surfacing: "Gacoflex UA -65" Series (various colors), applied 1 gal /sq (12 Structural cement fiber building units are considered suitable to I dry mils). as a deck in the following Class A, B or C systems listed over C -1'- 30. Deck: NC Incline: 1/2 The use of gypsum board under any of the following Class A, B o Foam: "Poly -Iso" or "Poly -Iso Special" with "Polyfoam 251" or "Polyfoam does not adversely effect the rating. The use of 1/2 in. min gyps'. 303 ", 1 in. min. an acceptable alternate for insulation over C -15/32 decks. Base Coat: One or two applications "Gacoflex UB- 7050 ", applied at 1 The use of polystyrene insulation board between min 3/4 in. pE gal /sq /application or three applications, applied 1 -1/4 gal /sq /application and deck with rosin paper (perlite /rosin paper /polystyrene /pe (16 -32 dry mils). suitable alternate for isocyanurate board in the following Class Surfacing: "Gacoflex UA -60" Series (various colors), applied 1 gat /sq (15 systems. dry mils). "GAFTEMP Isotherm RA ", " GAFTEMP Tapered Isotherm RA" and "GAFTEMP 31. Deck: NC Incline: 2 Composite A" may be substituted for any isocyanurate insulation in any of the Foam: "Poly -Iso" or "Poly -Iso Special" with "Polyfoam 251" or "Polyfoam following Classifications. 303 ", 1 in. min. Trumbull "Perma Mop" may be utilized with any of the following "Asphalt Felt Base Coat: "GacoSil S- 1000 ", applied at 1 gal /sq (10 dry mils). Systems with Hot Roofing Asphalt ". Surfacing: "Gacoflex S- 1000 ", applied at 1 gal /sq (10 dry mils). GAFGLAS #80 Premium Base Sheet may be used in any of the following 32. Deck: NC Incline: 1 systems. Foam: "Polyfoam 251" or "Polyfoam 303 ", any thickness. Class A, B and C. Surfacing: "Gacoflex Ure- Shield 7007 ", 40 dry mils. Hot roofing asphalt, for use with organic and glass felts or modified bitumen 33. Deck: NC Incline: 2 membranes. / -� Foam: "Polyfoam 275 ", any thickness. `Class A) Base Coat: "Gacoflex A- 6211 ", 1 -1/2 gal /sq (14 dry mils). 1. Deck: C -15/32 — Incline: 3 Surfacing: "Gacoflex A- 6200" series (various colors), 1 -1/2 gal /sq (14 Insulation (Optional): One or more layers perlite, wood fiber, glass dry mils). fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ 34. Deck: NC Incline: 2 urethane composite, wood fiber /isocyanurate composite, phenolic, any Foam: Polyfoam 251, "Polyfoam 275" or "Polyfoam 303 ", any thickness. thickness. Base Coat: One or two applications "Gacoflex UB- 7050 ", applied at 1 Ply Sheet: Three or more layers Type G1 "GAFGLAS Ply 4" or "GAFGLAS Ply gal /sq. /application (16 -32 dry mils). 6 ", hot mopped. Surfacing: One application of "Gacoflex A -55 Series" (various colors), Surfacing: Gravel. applied at 1 -1/2 gal /sq. (15 dry mils). °Deck: C -15/32 Incline: 2 35. Deck: NC Incline: 1/4 Insulation (Optional): One or more layers perlite, wood fiber, glass Foam: "Polyfoam 251 ", "Polyfoam 275" or "Polyfoam 303 ", any thickness. fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ Base Coat: "Gacoflex UB -64," applied at 1 -1/2 gal /sq. (18 dry mils). urethane composite, wood fiber /isocyanurate composite, phenolic, any Trowel Coat: 30/60 mesh crushed walnut shells mixed at a rate of 5 thickness. lb /gat with "Gacoflex UB -64," applied at 1 -1/2 gal /sq or "Gacoflex Ply Sheet: Three or more layers Type G1 "GAFGLAS Ply 4" or "GAFGLAS Ply UB -64 ", applied at 1 -1/2 gal /sq (18 dry mils) followed by the broadcast 6" application of 30/60 mesh crushed walnut shells applied at 7 -8 lb /sq. Cap Sheet: One layer Type G3 "GAFGLAS Mineral Surfaced Cap Sheet ". Surfacing: "Gacoflex U -66 ", applied at 1/2 gal /sq. (6 dry mils). 3. Deck: NC Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber, glass GAF MATERIALS CORP R1306 fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ 1361 ALPS RD, WAYNE NJ 07470 urethane composite, wood fiber /isocyanurate composite, phenolic, 2 in. "RUBEROID 20" or "RUBEROID Modified Base Sheet" may be utilized as an max. alternate to Type G2 base sheets in any of the following Classifications. Ply Sheet: Two or more layers Type G1 "GAFGLAS Ply 4" or "GAFGLAS Ply 1/2 in. thick (min) gypsum board or 1/4 in. thick (min) Georgia- Pacific 6 ". "Dens - Deck ®" overlayment board may be used in any existing noncombustible Cap Sheet: One layer Type G3 "GAFGLAS Mineral Surfaced Cap Sheet ". deck Classification. When this is done, the resulting roofing system is 4. Deck: NC Incline: 1/2 acceptable for use over combustible (15/32 in. min) roof decks. The joints in Insulation: One or two layers "Isotherm R ", 4 in. max, hot mopped. the gypsum board and overlayment board are offset 6 in. with the joints in the Ply Sheet: Any UL Classified gravel surfaced Class A asphalt glass fiber deck. If polystyrene is part of the roof system, it must be placed below the mat system. 1 overlayment board. 5. Deck: C -15/32 Incline: 1 Also, multiple plies of "GAFGLAS Ply 4" or "Ply 6" may be adhered to Slip Sheet (Optional): Red rosin paper, nailed to deck. "Dens- Deck" in hot asphalt. Base Sheet: One layer of Type G2 "GAFGLAS #75 Base Sheet" (may be "GAFGLAS Stratavent Nailable Base Sheet" may be mechanically attached or nailed). hot mopped over noncombustible decks and as a recover over existing roof Ply Sheet: One or more layers of Type G1 "GAFGLAS Ply 4" or GAFGLAS Ply systems. 6 ". GAFGLAS Perlite Insulation may be utilized as a cover board over "EVERGUARD" Cap Sheet: One layer of Type G -3 "GAFGLAS Mineral Surfaced Cap Sheet ". insulation in any of the following systems. 6. Deck: NC Incline: 3 ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Base Sheet: One layer of Type G2 "GAFGLAS #75 Base Sheet'. Type G2 asphalt glass mat base sheet ( "GAFGLAS #75 Base Sheet" or "GAFGLAS Ply Sheet: One or more layers of Type G1 "GAFGLAS Ply 4" or GAFGLAS Ply #80 Premimum Base Sheet ") is a suitable alternate for Type G1 asphalt glass 6". r' fiber ply sheet ( "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ") in the Class A, B or C roof Cap Sheet: One layer of Type G -3 "GAFGLAS Mineral Surfaced Cap Sheet ". / • systems indicated below. 7. Deck: C -15/32 Incline: 2 The roof deck may first be covered with a Type G2 asphalt glass mat base Insulation: One or more layers perlite, glass fiber, isocyanurate, urethane, sheet "GAFGLAS Stratavent (Vent -Ply) perforated" or "GAFGLAS Stratavent perlite /isocyanurate composite, perlite /urethane composite, phenolic, (Vent -Ply) for nailable decks ". Perforated to be mopped and nailable to be 1.0 in. min (offset from plywood joints 6 in.). mechanically attached granule side down. Base Sheet: One or more layers of Type 01, G2 or G3. As an option Type G2 asphalt glass mat base sheet ( "GAFGLAS #75 Base Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), Sheet", "GAFGLAS #80 Premium Base Sheet" or "GAFGLAS Stratavent (Vent -Ply) "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or for nailable decks ") may be substituted for G1 asphalt glass fiber ply sheet "Ruberoid Mop Plus" (granule). ( "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ") as the nailed base ply in the following Cap Sheet: "GAFGLAS Mineral Surfaced Cap Sheet ", hot mopped. systems. 8. Deck: C -15/32 Incline: 2 Bottom ply or base sheet may be solid mopped, spot mopped or mechanically Insulation (Optional): One or more layers perlite, wood fiber, glass fastened. fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ Unless otherwise indicated, all insulations may be hot mopped or mechanically urethane composite, wood fiber /isocyanurate composite, phenolic, any fastened. thickness. LOOK FOR THE UL MARK ON PRODUCT CITY OF TIGARD BUILDING INSPECTION DIVISION 14 -flour Inspection Line: 639 -4175 Business Line: 639 -4171 r nis-r � �.�b BuP Z�v co 7 / Date Requested (/Zr AM PM BLD Location `(0 C ASS t it • ... MEC Contact Person Ph NJ PLM Contr Ph SWR UILDING ` Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS , Ftg Drain SGN Crawl Drain Inspection Notes:�n ,� Slab " `�' \ -S SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall , Fire Sprinkler Fire Alarm S •' • _ eiling 4.19- chin Misc: n ASS ART FAIL ING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other Date W7E Inspector Ext3 r Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site.