Loading...
Plans r,t ri r i r Mark VanDomelen - x From: Mike K. Brown [ Mike .Brown @core - engineering. net] Sent: Thursday, July 01, 2010 11:13 AM To: Mark VanDomelen Cc: Gayland Forsberg; Kelly Ritz Subject: Lot 58, Arlington Heights Retaining Walls Attachments: image001.gif Mark,1 , I had a lengthy discussion with Eric Watson regarding the retaining walls and buttresses. One item we need to add to the drawings is that the restrained retaining walls along the front need to have the following horizontal reinforcing: • 16 foot high wall 144 at 12" o.c. • 13 foot high wall #5 at 8" o.c. • 12 foot high wall #6 at 6" o.c. -Mike c/ae2, &owa, S.E. NI C °. I i 3501 W. Elder St. iM &T — C Boise, ID 83716 Office: 208 - 386 -9170 City of Tigard Direct: 208-908-4800 A:.t • -1 Plan Cell: 208 - 850 -7542 B ,���, \�. Date Fax: 208 - 386 -9076 .. •_ __.. Mike.brown@core- engineering.net z G� e . 4 'isr-\ C T REVISION OFFICE COPY MICHAEL K. BROWN Registered Professional Structural Engineer In Partners With Structural Engineers E 3 501 "test Elder St r e et, ' >u l t e 100 Boise, Idaho 83705 ENGINE RING Ph. (208) 386 -9170 =--w Fax(208)386 -907h www.core- engineering.net BASEMENT RETAIN IN 4.; WALL DESIGN CALCULATIONS FOR LOT 58, ARLINGTON HEIGHTS l TIGARD, 0 CORE ENGR. JOB # B10- 91 ncTu ,,‘",-,,-, ,,.--- 1 1 e(c. `''' , .,,, , ,- , !i 411114 f lc L 7 ." ..._:, ' , c fj EX PIRAT10 D T E: ° 2 r ° , Prepared for: StoneBridge Homes, NW, LLC DMH Job #: 1480 -238 Date: 7-01-2010 The following calculations are for Retaining Wall engineering only. The design is based on information provided by the client who is solely responsible for its accuracy. The engineering represents the finished product. Discrepancies from information provided by the client invalidate this design. Core Engineering shall have no liability (expressed, or implied), with respect to the means and methods of construction workmanship or materials. Core Engineering, PLLC. shall have no obligation of liability, whether arising in contract (including warranty), Tort (including active, passive, or imputed negligence) or otherwise, for loss or use, revenue or profit, or for any other incidental or consequential damage 4 i -, • 3501 West Elder Street Suite 100 Boise, ID 83705 - .' Phone: (208) 386 -9170 Wi _ .� z: . : � ,. Fax: (208) 386 -9076 www.core - engineering.net =ORE ENGINEERING Job Name: Lot 58, Arlington Heights By : MKB Core Job Number: B10 -897 Date: June, 2010 Tall Retaining Wall Options: Tall Walls shall be braced at floor level, therefore At Rest Wall Pressure is 60 PSF /FT Top of Soil Max Wall Height, 'H' = 16 Feet y Horizontal Force at Bottom of Wall = 960 PLF Horizontal Force 2' up from bottom = 840 PLF } Average Load at Bottom of Wall = 900 PLF .` 'H' - } Load for Analysis = 1800 PLF k Max Wall Height, 'H' = 13 Feet (4) #4 LONG & #4 @ 24" Horizontal Force at Bottom of Wall = 780 PLF. TRANS 2' 4 Horizontal Force 2' up from bottom = 660 PLF ' T 3 Average Load at Bottom of Wall = 720 PLF Horizontal Reinforcing: Load for Analysis = 1440 PLF Wall Ht. Wall Length Horizontal Reinf. 16' 5' #4 at 12" O.C. Max Wall Height, 'H' = 12 Feet 13' 6' #5 at 8" O.C. 12' 9' #6 at 6" O.C. Horizontal Force at Bottom of Wall = 720 PLF Vert. Reinf shall be #4 at 24" O.C. Center all Reinforcting in Wall Horizontal Force 2' up from bottom = 600 PLF (See attached Enercalc Output Average Load at Bottom of Wall = 660 PLF Load for Analysis = 1320 PLF Title Block Line 1 Title : Job # You can changes this area Dsgnr: using the "Settings" menu item Project Desc.: and then using the "Printing & Title Block" selection. Project Notes Title Block Line 6 Printed: 1 JUL 2010, 1001AM Concrete Beam Design Al Projects\ Projects12010ProjectsIB10- 897J1429Revision' 3 Car Garagel Calcsl RetairiingWalls lretainingwalls.ec6 g ENERCALC, INC. 1983 -2010, Ver: 6.1.50, N:89702 Lic. # : KW -06005725 License Owner: CORE ENGINEERING PLLC Description : Span 16' tall retraining wall horizontal to Perp concrete shear walls Material Propertie Calculations per IBC 2006, CBC 2007, ACI 318 - 05 fc 1/2 = 3.0 ksi (I) Phi Values Flexure : 0.90 fr = fc * 7.50 = 410.79 psi Shear : 0.750 tif Density = 145.0 pcf p 1 = 0.850 Elastic Modulus = 3,122.0 ksi Load Combination 2006 IBC & ASCE 7 -05 c • Fy - Main Rebar = 60.0 ksi Fy - Stirrups = 40.0 ksi , E - Main Rebar = 29,000.0 ksi E - Stirrups = 29,000.0 ksi . Stirrup Bar Size # # 3 Num of Bars Crossing Inclined Crack = 2 24 in E 0.78 H 1.8 • • 24 w x 8 h Span =3.0 ft Cross Section & Reinforcing Details Rectangular Section, Width = 24.0 in, Height = 8.0 in Span #1 Reinforcing.... 2-#4 at 4.0 in from Top, from 0.0 to 3.0 ft in this span Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number 1 Uniform Load : E = 0.780, H =1.80 k/ft, Tributary Width = 1.0 ft DESIGN SUMMARY . ° ,, Design OK Maximum Bending Stress Ratio = 0.385: 1 Maximum Deflection Section used for this span Typical Section Max Downward L +Lr +S Deflection 0.000 in Ratio = 0 <360 Mu : Applied 2.639 k -ft Max Upward L +Lr +S Deflection 0.000 in Ratio = 0 <360 Mn * Phi : Allowable 6.847 k -ft Max Downward Total Deflection 0.001 in Ratio = 35135 Load Combination +D+0.70E+H Max Upward Total Deflection 0.000 in Ratio = 999 <180 Location of maximum on span 1.500ft Span # where maximum occurs Span # 1 Vertical Reactions - Unfactored . Support notation : Far left is #1 Load Combination Support 1 Support 2 Overall MAXimum 2.700 2.700 H Only 2.700 2.700 Shear Stirrup Requirements No Stirrups Required from 0.00 to 3.00 ft along span, Condition : Vu < PhiVc /2 r Maximum Forces & Stresses for.'Load Combinations Load Combination Location (ft) Bending Stress Results (k -ft ) . Segment Length Span # in Span Mu : Max Phi *Mnx Stress Ratio MAXimum BENDING Envelope Span # 1 1 1.500 2.64 6.85 0.39 +D+L+H Span # 1 1 1.500 2.03 6.85 0.30 +D +Lr +H Span # 1 1 1.500 2.03 6.85 0.30 +D +S +H Span # 1 1 1.500 2.03 6.85 0.30 +D+0.750Lr+0.750L +H Span # 1 1 1.500 2.03 6.85 0.30 .1l.117CM .117CA(1 Title Block Line 1 Title . Job # You can changes this area Dsgnr: using the "Settings" menu item Project Desc.: and then using the "Printing & Project Notes : Title Block" selection. Title Block Line 6 Printed: 1 JUL 2010, 1001AM Concrete Beam Design o d Projects\ Projects12010Projects1 B10- 897J1429Revisio Cat Garage1Calcs\ Retaining Walls Iretainingwalls .ec6 g ENERCALC, INC.-1983-2010, Verr 6.1.50, N:89702 Lic. # : KW -06005725 License Owner : CORE ENGINEERING PLLC Description : Span 16' tall retraining wall horizontal to Perp concrete shear walls Load Combination Location (ft) Bending Stress Results (k -ft ) Segment Length Span # in Span Mu : Max Phi*Mnx Stress Ratio Span # 1 1 1.500 2.03 6.85 0.30 +D +W +H Span # 1 1 1.500 2.03 6.85 0.30 +D+0.70E+H Span # 1 1 1.500 2.64 6.85 0.39 +D+0.750Lr+0.750L+0.750W+H Span # 1 1 1.500 2.03 6.85 0.30 +D+0.750L+0.750S+0.750W +H Span # 1 1 1.500 2.03 6.85 0.30 +D+0.750Lr+0.750L+0.5250E+H Span # 1 1 1.500 2.49 6.85 0.36 +D+0.750L+0.750S+0.5250E+H Span # 1 1 1.500 2.49 6.85 0.36 +0.60D +W+H Span # 1 1 1.500 2.03 6.85 0.30 +0.60D+0.70E+H Span # 1 1 1.500 2.64 6.85 0.39 Overall Maximum Deflections - Unfactored Loa Load Combination Span Max. " Defl Location in Span Load Combination Max. " +" Defl Location in Span H Only 1 0.0010 1.463 0.0000 0.000 Title Block Line 1 Title : Job # You can changes this area Dsgnr: using the "Settings" menu item Project Desc.: and then using the "Printing & Project Notes : Title Block" selection, Title Block Line 6 Printed. 1 JUL 2010.10.01AM Concrete Beam Desi n iiProjectsl Projects12010Projects1B10- 897J1429 Revision 3 Car Garagel Calcs\ RetainingWallslr etainingwalls,ec6 g ENERCALC, (NC. 1983-201'0, Ver: 6.1.50, N:89702 Lic. -#: KW 416005725 License, Owner CORE ENGINEERING PLLC Description : Span 13' tall retraining wall horizontal to Perp concrete shear walls M aterial Propertie Calculations per IBC 2006, CBC 2007, ACI 318 -05 fc 112 * = 3.0 ksi Phi Values Flexure : 0.90 fr = fc 7.50 = 410.79 psi Shear : 0.750 yr Density = 145.0 pcf 13 1 = 0.850 1111111111 . Elastic Modulus = 3,122.0 ksi Load Combination 2006 IBC & ASCE 7 -05 Fy - Main Rebar = 60.0 ksi Fy - Stirrups = 40.0 ksi E - Main Rebar = 29,000.0 ksi E - Stirrups = 29,000.0 ksi Stirrup Bar Size # # 3 Num of Bars Crossing Inclined Crack = 2 24 in -_.. E 0.78 H 1.44 • 24 "wx8 " • A . Span =6.0 ft Cross Section & Reinforcing_Details Rectangular Section, Width = 24.0 in, Height = 8.0 in Span #1 Reinforcing.... 3-#5 at 4.0 in from Top, from 0.0 to 6.0 ft in this span Applied Loads • Service loads entered. Load Factors will be applied for calculations. Load for Span Number 1 Uniform Load : E = 0.780, H = 1.440 k/ft, Tributary Width =1.0 ft DESIGN SUMMARY - ::'-: . Desi OK • Maximum Bending Stress Ratio = 0.603: 1 Maximum Deflection Section used for this span Typical Section Max Downward L +Lr +S Deflection 0.000 in Ratio = 0 <360 Mu : Applied 8.937 k -ft Max Upward L +Lr +S Deflection 0.000 in Ratio = 0 <360 Mn * Phi : Allowable 14.832 k -ft Max Downward Total Deflection 0.013 in Ratio = 5489 Load Combination +D+0.70E +H Max Upward Total Deflection 0.000 in Ratio = 999 <180 Location of maximum on span 3.000ft Span # where maximum occurs Span # 1 Verti Reactions - U nfactored Support notation : Far left is #1 Load Combination Support 1 Support 2 Overall MAXimum 4.320 4.320 H Only 4.320 4.320 Shear Requirements No Stirrups Required from 0.00 to 0.67 ft along span, Condition : PhiVc/2 < Vu <= PhiVc No Stirrups Required from 0.68 to 5.32 ft along span, Condition : Vu < PhiVc /2 No Stirrups Required from 5.33 to 6.00 ft along span, Condition : PhiVc/2 < Vu <= PhiVc Maximum Forces & Stresses for Load Combinations Load Combination Location (ft) Bending Stress Results (k -ft ) Segment Length Span # in Span Mu : Max phi *Mnx Stress Ratio MAXimum BENDING Envelope Span # 1 1 3.000 8.94 14.83 0.60 +D+L+H Span # 1 1 3.000 6.48 14 83 0.44 +D +Lr+H Span # 1 1 3.000 6.48 14.83 0.44 +D +S +H Span # 1 1 3.000 6.48 14.83 0.44 Title Block Line 1 Title : Job # You can changes this area Dsgnr: using the "Settings" menu item Project Desc.: and then using the "Printing & Project Notes : Title Block" selection. Title Block Line 6 Printed: 1 JUL2010, 1001AM Concrete Beam Design I Proj ectslPr0j ectsl201 0Proi ects\ B, o897J1429 Revision 3 Car Garagel Calch\ RetainingWallslretainingwalls .ec6 ENERCALC „ INC. 1983-2010, Ver: 6.1.50, N:89702 Lic. #': KW -06005725 • License Owner: CORE ENGINEERING PLLC Description : Span 13' tall retraining wall horizontal to Perp concrete shear walls Load Combination Location (ft) Bending Stress Results (k -ft ) Segment Length Span # in Span Mu : Max Phi *Mnx Stress Ratio Span # 1 1 3.000 6.48 14.83 0.44 +D+0.750L+0.7505+H Span # 1 1 3.000 6.48 14.83 0.44 +D +W+H Span # 1 1 3.000 6.48 14.83 0.44 +D+0.70E+1i Span # 1 1 3.000 8.94 14.83 0.60 +D+0.750Lr+0.750L+0.750W+H Span # 1 1 3.000 6.48 14.83 0.44 +D+0.750L+0.750S+0.750W +H Span # 1 1 3.000 6.48 14.83 0.44 +D+0.750Lr+0.750L+0.5250E+H Span # 1 1 3.000 8.32 14.83 0.56 +D+0.750L+0.7505+0.5250E+H Span # 1 1 3.000 8.32 14.83 0.56 +0.60D +W+H Span # 1 1 3.000 6.48 14.83 0.44 +0.60D+0.70E +H Span # 1 1 3.000 8.94 14.83 0.60 Overall Maximum Deflections - Unfactored Loads Load Combination Span Max. -" Defl Location in Span Load Combination Max. " +" Defl Location in Span H Only 1 0.0131 2.925 0.0000 0.000 Title Block Line 1 Title . Job # You can changes this area Dsgnr: using the "Settings" menu item Project Desc.: and then using the "Printing & Title Block" selection. Project Notes Title Block Line 6 Punted: 1 JUL 2010, 10 01A Concrete Beam Design 1Projects\ Projects1 2010Projects1B10- 897J1429. Revision3 Car Garagel CalcslRetainingWallslretainingwalls .ec6 g ENERCALC, INC. 1983 -2010, Ver: 6:1.50, N:89702 Lic. #': KW -06005725' License Owner': CORE ENGINEERING'PLLC Description : Span 12' tall retraining wall horizontal to Perp concrete shear walls Material Properties Calculations per IBC 2006, CBC 2007, ACI 318 - 05 fc 1/2 3.0 ksi d Phi Values Flexure : 0.90 fr = fc 1/2 7.50 = 410.79 psi Shear : 0.750 , tv Density = 145.0 pcf a = 0.850 • Elastic Modulus = 3,122.0 ksi Load Combination 2006 IBC & ASCE 7 -05 m • Fy - Main Rebar = 60.0 ksi Fy - Stirrups = 40.0 ksi E - Main Rebar = 29,000.0 ksi E - Stirrups = 29,000.0 ksi . Stirrup Bar Size # # 3 Num of Bars Crossing Inclined Crack = 2 24 in E(0.78) H(1.32) 24 "wx "h Span =9.0 ft Cross Section & Reinforcing Details _ Rectangular Section, Width = 24.0 in, Height = 8.0 in Span #1 Reinforcing.... 4-#6 at 4.0 in from Top, from 0.0 to 9.0 ft in this span Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number 1 Uniform Load : E = 0.780, H = 1.320 k/ft, Tributary Width = 1.0 ft DESIGN SUMMARY,, Design Maximum Bending Stress Ratio = 0.760: 1 Maximum Deflection Section used for this span Typical Section Max Downward L +Lr +S Deflection 0.000 in Ratio = 0 <360 Mu : Applied 18.893 k -ft Max Upward L +Lr +S Deflection 0.000 in Ratio = 0 <360 Mn * Phi : Allowable 24.847 k -ft Max Downward Total Deflection 0.164 in Ratio = 660 Load Combination +0+0.70E+H Max Upward Total Deflection 0.000 in Ratio = 999 <180 Location of maximum on span 4.500ft Span # where maximum occurs Span # 1 'Vertical Reaction s -- Unfactored Support notation : Far left is #1 Load Combination Support 1 Support 2 Overall MAXimum 5.940 5.940 H Only 5.940 5.940 • Shear Stirrup Requirements No Stirrups Required from 0.00 to 1.60 ft along span, Condition : PhiVc/2 < Vu <= PhiVc No Stirrups Required from 1.63 to 7.38 ft along span, Condition . Vu < PhiVc /2 No Stirrups Required from 7.40 to 9.00 ft along span, Condition : PhiVc/2 < Vu <= PhiVc Maximum Forces & Stresses f or Load.Combinations Load Combination Location (ft) Bending Stress Results (k -ft ) Segment Length Span # in Span Mu : Max Phi *Mnx Stress Ratio MAXimum BENDING Envelope Span # 1 1 4.500 18.89 24.85 0.76 +D+L+H Span # 1 1 4.500 13.37 24.85 0.54 +D +Lr+H Span # 1 1 4.500 13.37 24.85 0.54 +D +S +H Span # 1 1 4.500 13.37 24.85 0.54 Title Block Line 1 Title : Job # You can changes this area Dsgnr: using the "Settings" menu item Project Desc.: and then using the "Printing & Project Notes : Title Block" selection. Title Block Line 6 Printed: 1 JUL 2010, 10:01AM Concrete Beam Design i1Projects lProjects12010.ProjectsIB10- 897- J1429 Revision 3 Car Garagel Calcs\ Retaining Walls \retainingwalls.ec6 g ENERCALC , INC. 1983- 2010,Ver:6.1.50, N:89702 tic. # : KW- 06005725 . License Owner COREENGINEERING PLLC Description : Span 12' tall retraining wall horizontal to Perp concrete shear walls Load Combination Location (ft) Bending Stress Results (k -ft ) Segment Length Span # in Span Mu : Max Phi *Mnx Stress Ratio Span # 1 1 4.500 13.37 24.85 0.54 +D+0.750L+0.750S+H Span # 1 1 4.500 13.37 24.85 0.54 +D +W+H Span # 1 1 4.500 13.37 24.85 0.54 +D+0.70E+H Span # 1 1 4.500 18.89 24.85 0.76 +D+0.750Lr+0.750L+0.750W+H Span # 1 1 4.500 13.37 24.85 0.54 +D+0.750L+0.7505+0.750W +H Span # 1 1 4.500 13.37 24.85 0.54 +D+0.750 Lr+0.750L+0.5250E+H Span # 1 1 4.500 17.51 24.85 0.70 +D+0.750L+0.750S+0.5250E+H Span # 1 1 4.500 17.51 24.85 0.70 +0.60D +W+H Span # 1 1 4.500 13.37 24.85 0.54 +0.60D+0.70E+H Span # 1 1 4.500 18.89 24.85 0.76 Overall Maximum Deflections - Unfactored Loads Load Combination Span Max. " -" Defl Location in Span Load Combination Max. " +" Defl Location in Span H Only 1 0.1635 4.613 0.0000 0.000 ,c) A` ' S-- w`7 N 3501 West Elder Street Suite 100 Boise, ID 83705 ,F _ ., Phone: (208) 386 -9170 Fax: (208) 386 -9076 www.core- engineering.net ENGINEERING Job Name: Lot 58, Arlington Heights By: MKB Core Job Number: B10 -897 Date: June, 2010 • At 10' High Walls: Soil Height above top of footing = 9.5 feet F'c = 2500 psi Soil Height above Toe = 2 foot fy = 60000 psi Footing Thickness = 12 inches b= 12 inches Footing Width = 4.5 feet Phi = 0.9 Toe Width = 3 feet Seismic Load due to wall = 40 plf Stem Thickness = 8 inches Coefficient of Friction = 0.4 Depth to rebar in Stem = 4 inches Area of reinforcing steel in Stem = 0.47 In ^2/ ft ( #5 at 8" o.c.) Vertical Dead Load = 390 plf Vertical Live Load = 800 plf Seismic due to Soil = 346.94 plf /ft of depth Sds = 0.83 Kh (Sds /2.5) = 0.332 Stem Wall Analysis: See Enercalc Beam Output 8" concrete wall with #5 at 8" o.c. okay Check Sliding Stability Sliding force = 7613.556 Pounds /foot of wall length Resistance: Wall Weight = 950 pounds Footing Weight = 675 Soil Weight over hee 238.3333 Vertical Dead Load = 390 soil weight over toe = 990 Total Weight = 3243.333 Pounds Resistance due to Friction = 1297.333 Passive Pressure = 250 Pounds /ft /ft 500 Pounds Total Sliding Resistance = 1797.3 < 8374.9114 , Therefore add'I resistance Required resistance = 6577.578 Pounds /foot Add Footing buttresses Title Block Line 1 Title : Job # You can changes this area Dsgnr: using the "Settings" menu item Project Desc.: and then using the "Printing & Project Notes Title Block" selection. Title Block Line 6 Printed: 1 JUL 2010, 10:01AM Concrete Beam Design tl Projects\Projects12010 Projects1B10 -897 J1429 Revision 3 Car Garage\ CalcslRetaining'Wallslretaining walls:ec6 ,. ENERCALC, INC, 1983, 2010, Ver: 6.1.50, N'.89702 Lic. #•: KW -06005725 License Owner,: CORE ENGINEERING PLLC Description : 9' retaining wall (Stem Wall) Material Properti Calculations per IBC 2006, CBC 2007, ACI 318 -05 fc = 2.50 ksi d Phi Values Flexure : 0.90 , fr = fc 112 * 7.50 = 375.0 psi Shear : 0.750 W Density = 145.0 pcf Q 1 = 0.850 Elastic Modulus = 3,122.0 ksi ; Load Combination 2006 IBC & ASCE 7 -05 m Fy - Main Rebar = 60.0 ksi Fy - Stirrups = ksi E - Main Rebar = 29,000.0 ksi E - Stirrups = ksi Stirrup Bar Size # # 3 , Num of Bars Crossing Inclined Crack = 1.0 , 16in E 0.053 ` • • • + + • • 2 16 "wx8 "h 2 Span =9.0 ft Cross Section -& Reinforcing Details Rectangular Section, Width = 16.0 in, Height = 8.0 in Span #1 Reinforcing.... 2-#5 at 4.0 in from Bottom, from 0.0 to 9.0 ft in this span Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number 1 Uniform Load : D = 0.0170 k/ft, Tributary Width = 1.0 ft, (Driveway Surcharge) Varying Uniform Load : H(S,E) = 0.0- >0.7180 k/ft, Extent = 0.0 - -» 9.0 ft, Trib Width = 1.0 ft, (Static Soil) Varying Uniform Load : E(S,E) = 0.4380 - >0.0 k/ft, Extent = 0.0 - -» 9.0 ft, Trib Width = 1.0 ft, (Seismic Loads from) Uniform Load : E = 0.0530 k/ft, Tributary Width = 1.0 ft, (seismic load from w) DESIGN SUMMARY 'v- : Design O O K Maximum Bending Stress Ratio = 0.597: 1 Maximum Deflection Section used for this span Typical Section Max Downward L +Lr +S Deflection 0.000 in Ratio = 0 <360 Mu : Applied 5.756 k -ft Max Upward L +Lr +S Deflection 0.000 in Ratio = 0 <360 Mn * Phi : Allowable 9.634 k -ft Max Downward Total Deflection 0.025 in Ratio = 4339 Load Combination +D+0.70E+H Max Upward Total Deflection 0.000 in Ratio = 999 <180 Location of maximum on span 4.775ft Span # where maximum occurs Span # 1 Vertical Reactions - Unfactored Support notation : Far left is #1 Load Combination Support 1 Support 2 Overall MAXimum 1.629 2.154 D Only 0.077 0.077 D+E 1.629 0.972 H Only 1.077 2.154 Sh Stirrup Requirements No Stirrups Required from 0.00 to 9.00 ft along span, Condition : Vu < PhiVc /2 Maximum Forces & Stresses for Load Combinations Load Combination Location (ft) Bending Stress Results (k -ft ) Segment Length Span # in Span Mu : Max phi *Mnx Stress Ratio MAXimum BENDING Envelope Span # 1 1 4.775 5.76 9.63 0.60 +D Span # 1 1 4.500 0.17 9.63 0.02 +D+L +H • ' Title Block Line 1 Title : Job # You can changes this area Dsgnr: using the "Settings" menu item Project Desc.: and then using the "Printing & Project Notes : Title Block" selection. Title Block Line 6 Printed. 1 JUL 2010, 1001AM Concrete Beam Desi n ii Projects1Projects12010 ProjectsIB10 -897 J1429 Revision 3 Car GaragelCalcslRetaining Wallslretaining walls.ec6 g ENERCALC, INC. 1983 -2010„ Ver: 6.1.50,. N :89702 Lic. #.:.KW -06005725. License Owner: CORE ENGINEERING ..PLLC' Description : 9' retaining wall (Stem Wall) Load Combination Location (ft) Bending Stress Results (k -ft ) Segment Length Span # in Span Mu : Max Phi *Mnx Stress Ratio +D+Lr+H Span # 1 1 5.175 3.90 9.63 0.40 +D +S +H Span # 1 1 5.175 3.90 9.63 0.40 +D+0.750Lr+0.750L +H Span # 1 1 5.175 3.90 9.63 0.40 +D+0.750L+0.750S+H Span # 1 1 5.175 3.90 9.63 0.40 +D +W +H Span # 1 1 5.175 3.90 9.63 0.40 +D+0.70E+H Span # 1 1 4.775 5.76 9.63 0.60 +D+0.750Lr+0.750L+0.750W+H Span # 1 1 5.175 3.90 9.63 0.40 +D+0.750L+0.7505+0.750W +H Span # 1 1 5.175 3.90 9.63 0.40 +D+0.750Lr+0.750L+0.5250E+H Span # 1 1 4.850 5.28 9.63 0.55 +D+0.750 L+0.750S+0.5250E+H Span # 1 1 4.850 5.28 9.63 0.55 +0.60D +W+H Span # 1 1 5.175 3.83 9.63 0.40 +0.60D+0.70E+H Span # 1 1 4.775 5.69 9.63 0.59 Overall Maximum Deflections - Unfactored Loads Load Combination Span Max. " -" Defl Location in Span Load Combination Max. " +" Defl Location in Span H Only 1 0.0249 4.613 0.0000 0.000 . ' 3501 West Elder Street Suite 100 Boise, ID 83705 Phone: (208) 386 -9170 Fax: (208) 386 -9076 www.core- engineering.net =ORE ENGINEEii1NG Job Name: Lot 58, Arlington Heights By: MKB Core Job Number: B10 -897 Date: June, 2010 At Tall Walls, Check Buttress Shear Walls Max Horizontal Load = 540 Pounds /ft/ft Height of Wall Including Seismic Load from Basement Wall = 288 Plf Resultant Horizontal Load = 55512 Pounds Footing = 14 � a I i � s. 540 plf /ft 5' min and 8' max See Enercalc Shear Wall Analysis Output Use 8" thick wall with #5 at 8" o.c. each way and 1' -6" wide x 12" thick footing with (2) #4 Bars Continuous Provide (4) #6 Verticals at each end. Title Block Line 1 Title : Job # You can changes this area Dsgnr: using the "Settings" menu item Project Desc.: and then using the "Printing & Project Notes Title Block" selection. Title Block Line 6 Printed 1 JUL 2010, 1001AM • Concrete Shear Wall 11 Projects\ Projects12010Projects1B10- 897J1429Revision3 Car Garage ICalcs\ Retaining Walls Vetaining .walls.ec6 ENERCALC, INC. 1983-2010, Ver:.6.1.50, 'N:89702 Lic. # : KW -06005725 • License Owner : BORE ENGINEERING PLLC Description : Buttress Wall General Information Wall Material Concrete Material Properties Sds 0.830 fc 2.50 ksi Ec 3,120.0 ksi Fy 60.0 ksi Ev 1,248.0 ksi Density 145.0 pcf Phi - Snear U.tibU Wall Data . Bottom Analysis Height 0.00 ft . Wall Offset ( datum) ft ' Wall Length 5.0 ft Wall Thickness 8.0 in Structural Depth 4.50 ft • DAV 5' -0" ft Applied Conce Lateral Lo ads Load Magnitude (kips) Load "Y" Location (ft) Wind Load Seismic Load 4.330 56.0 DESIGN SUMMARY • Bottom Level 2nd Level 3rd Level 4th Level 5th Level Vu : Story Shear 56.0 +1.20D+0.50L+0.; 0.0 0.0 0.0 0.0 k Mu : Story Moment 242.48 +1.20D+0.50L+0. 0.0 0.0 0.0 0.0 k - ft Nu :Axial 8.797 +1.400 0.0 0.0 0.0 0.0 k Uplift @ Left End 50.394 +1.20D+0.50L+0.; 0.0 0.0 0.0 0.0 k Uplift @ Right End 50.394 +1.20D+0.50L+0.: 0.0 0.0 0.0 0.0 k vu : Applied 86.420 psi 0.0 psi 0.0 psi 0.0 psi 0.0 psi vc *.85 142.85 psi 0.0 psi 0.0 psi 0.0 psi 0.0 psi vn:max =.6 *10 *sqrt(fc) 300.0 psi 0.0 psi 0.0 psi 0.0 psi 0.0 psi Horizontal As Req'd 0.360 in 0.0 inA2 0.0 inA2 0.0 inA2 0.0 inA2 Vertical As Req'd 0.360 inA2 0.0 inA2 0.0 inA2 0.0 inA2 0.0 in Bending As Req'd 1.357 inA2 0.0 inA2 0.0 in 0.0 inA2 0.0 inA2 Title Block Line 1 Title : Job # You can changes this area Dsgnr: using the "Settings" menu item Project Desc.: and then using the "Printing & Project Notes : Title Block" selection. Title Block Line 6 Printed. 1 JUL 2010. 10.01AM IiProjects\ Projects12010Projects1B10897J1429Revisio Ga�age\ Calcsl RetainingWallsretainingwalls .ec6 Concrete Shear Wall ENERCALC, INC. 19832010, Ver: 6.1.50, N.89702 Lic. # : KW -06005725 • ` ., License:Owner : CORE ENGINEERING PLLC Description : Buttress Wall Footing Information Footing Dimensions Dist. Left 0.50 ft fc 2.50 ksi Rebar Cover 3.0 in Wall Length 5.0 ft Fy 60.0 ksi Footing Thickness 12.0 in Dist. Right 0.50 ft Width 1.50ft Total Ftg Length 6.0 ft Max Factored Soil Pressures Max UNfactored Soil Pressures @ Left Side of Footing 1,181.29 psf @ Left Side of Footing 843.78 psf .... governing load comb +1.40D .... governing load comb +D @ Right Side of Footing 1,181.29 psf @ Right Side of Footing 843.78 psf .... governing load comb +1.40D .... governing load comb +D Footing One -Way Shear Check... Overturning Stability... @ Left End of Ftg @ Right End of Ftg vu @ Left End of Footing 0.0 psi Overturning Moment 208.94 k -ft 208.94 k -ft vu @ Right End of Footing 0.0 psi Resisting Moment 11.774 k -ft 15.544 k -ft vn' phi : Allowable 85.0 psi Stability Ratio 0.05635 : 1 0.07440: 1 .... governing load comb +0.60D+0.70E +0.60D+0,70E Footing Bending Design... @ Left End @ Right End Mu 0.2215 k -ft 0.2215 k -ft Ru 2.026 psi 2.026 psi As % Req'd 0.00180 inA2 0.00180 in ^2 As Req'd in Footing Width 0.2916 inA2 0.2916 in ^2