Plans rk ri°S ?o II- 000©42 99.6 5W vee1411/r 4L/g64 Bulletin 136 Rev.O i J ® Model F1 F co ,,, Model F1FR Recessed 1 Quick Response SprinkIREEENED o DJ Model Fl FR Sprinkler Types Standard Upright 4� Standard Pendent C T oF N ' `, Conventional 8ui NGD _'' Vertical Sidewall Horizontal Sidewall r F , :r > - HSW 1 Deflector 7 V Model F1FR Recessed Sprinkler Types - Recessed Pendent Upright Pendent Recessed Horizontal Sidewall - HSW 1 Deflector Listings & Approvals - ` 1. Listed by Underwriters Laboratories, Inc. (UL) t ' 2. Listed by Underwriters' Laboratories of Canada (ULC) , 3. Certified by FM Approvals .e = 4. Loss Prevention Council (LPC, UK) - 5. NYC BS &A No. 587 -75 -SA 1 � 6. Meets MIL- S -901C and MIL -STD 167 -1 o 7. Verband der Schadenversicherer (VdS, Germany) 1 8. NYC MEA 258 -93 -E k UL Listing Category Vertical Sidewall Conventional 1 Sprinklers, Automatic & Open Quick Response Sprinkler i UL Guide Number VNIV .�• ,° - y �j 0 yy ` Patents: US Patent No. 6,374,920 Applies to 1 Model F1FR Vertical Sidewall Sprinklers. , „,, -- Product Description Horizontal Sidewall Recessed Pendent Reliable Models F1FR and F1FR Recessed Sprinklers are HSW 1 Deflector (Model FP Shown) quick response sprinklers which combine the durability of a pands, forcing the bubble smaller and smaller as the liquid standard sprinkler with the attractive low profile of a decorative pressure increases. Continued heating forces the liquid to sprinkler. push out against the bulb, causing the glass to shatter, The Models Fl FR and Fl FR Recessed automatic sprinklers opening the waterway and allowing the deflector to distrib- utilize a 3.0 mm frangible glass bulb. These sprinklers have ute the discharging water. demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This Application quick response enables the Model Fl FR and Fl FR Recessed Quick response sprinklers are used in fixed fire protec- sprinklers to apply water to a fire much faster than standard tion systems: Wet, Dry, Deluge or Preaction. Care must be sprinklers of the same temperature rating. exercised that the orifice size, temperature rating, deflector The glass bulb consists of an accurately controlled amount style and sprinkler type are in accordance with the latest of special fluid hermetically sealed inside a precisely manu- published standards of the National Fire Protection Asso- factured glass capsule. This glass bulb is specially con- ciation or the approving Authority Having Jurisdiction. ,. structed to provide fast thermal response. The balance of Quick response sprinklers are intended for installation as parts are made of brass, copper and beryllium nickel. specified in NFPA 13, FM Global Loss Prevention Data At normal temperatures, the glass bulb contains the fluid Sheet 2 -8N or other applicable standards. Quick response in both the liquid and vapor phases. The vapor phase can sprinklers and standard response sprinklers should not be be seen as a small bubble. As heat is applied, the liquid ex- intermixed. The Reliable Automatic Sprinkler Co., Inc. 103 Fairview Park Drive, Elmsford, New York 10523 lk y Model F1 FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: ` K Factor Sprinkler Identification Sprinkler Type Sprinkler Approval Number (SIN) a US Metric Height Organization SSU SSP Standard- Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position X" (15mm) Standard Orifice with X" NPT (R)2) Thread 5.6 80 2.2" (56mm) 12,3,4,5,6,7 R3625t R3615 17 „' (20mm) Large Orifice with %” NPT (R /4)Thread 8.0 115 2.3" (58mm) 1,2,3,4,7,8 R3622 R3612 %fi' (17mm) Small Orifice with )z" NPT (RX) Thread 4.2 60 2.2" (56mm) 12,8 R3623 R3613 %" (10mm) Small Orifice with )Z" NPT (RX) Thread 2.8 40 2.2" (56mm) 1,2,8 R3621 R3611 10mm Orifice XLH with R%" Thread 4.2 60 56mm 4,6,7 R3624 193614 Conventional- Install in Upright or Pendent Position 10mm Orifice XLH with R% Thread 4.2 60 56mm R3674 15mm Standard Orifice with ) " NPT (RX) Thread 5.6 80 56mm 4,6,7 R3675 20mm Large Orifice with 3/4' NPT (R /4)Thread 8.0 115 58mm 4,7 R3672 (1) Polyester coated upright UL and ULC listed corrosion resistant. cr •- S 4r 4',m } - y i 1. 1 .-t, 7:!: M. . r QU f ' S Upright Pendent Conventional Model F1 FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench Z Installation Data: t Nominal Thread K Factor Sprinkler Approval Sprinkler Identification Orifice Size US Metric Height Organizations Number (SIN) y," (15mm) )Z" NPT (RY) 5.6 80 2.2" (56mm) 1,2,3,4,5,7,8 R3615 1 %' (20mm) %" NPT (R /4) 8.0 115 2.3" (58mm) 1,2,3,8 R3612 T / (11mm) )2" NPT (R 4.2 60 2.2" (56mm) 1,2,8 R3613 %" (10mm) y" NPT (R 2.8 40 2.2" (56mm) 1,2,8 R3611 10mm RY 4.2 60 56mm 4,7 R3614 (1) Refer to escutcheon data table for approvals and dimensions. 2 I /4' HOLE DIA y �— 2 5/8' DIA. [66.7mm] (57.2mm] HOLE IN CEILING I 15/16' DIA 2 5 /I6" D /A. (58.7mm] ~ [49. 2mm] / CUP L - =I - I r =___, ---- I' RED X I /2" REDUCER TURN COLLAR T I UNRL TIGHT AGAINST SPRINKLER WRENCH BOSS \ 1 ! 1y - 1- -- =1 ■ � FACE OF FITRNC TO CEILING am �, ADJUSTMENT (I) ��' I CEILING II DINENS/ON Vd + ® 1 I 1, k 00, I TO FACE OF I CE I ILING 1 /B . J I ,` ) DIMENSION(,) (J.2mm] A "(1) LLB` \\ .. _ 1 rI r. I .1 L (I) . (l) 2 27/32" DLL ADJUSTMENT -- -- [72.2mm] IJBFCOl_E -- MMO5_A (I) REFER TO Fl & F2 ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. (1) REFER TO FP ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. 2. I e 4 Model F1 FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: K Factor Sprinkler Nominal Thread Sprinkler Approval Orifice Size US Metric Height Organizations Num beer r (SIN) Number h" 1 /2" NPT (RY) 5.6 80 2.2" (56mm) 1, 2, 3, 6, 8 - R3685 15mm 1/2" NPT (R'h) 5.6 80 2.2" (56mm) 4 (1) (1) LPC Approval is for Pendent position only. Orientation Deflector to Ceiling .� == Dimension (Min. - Max.) Upright 4" - 12" (102mm - 305mm) Pendent 6" - 12" (152mm - 305mm) I _Ldt I J Vertical Sidewall US Patent No. 6,374,920 -, Model F1 FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: Approval Organizations K Factor and Type of Approval Sprinkler Identification Nominal Thread Sprinkler Light Ordinary Number (SIN) Orifice Size US Metric Length Hazard Hazard }2" (15mm) }2" NPT(RY) 5.6 80 2.63" (67mm) 1,2,3,5,8 1,2,5,8 R3635 NOTE: UL, ULC and MEA Listing permits use with F1 or F2 recessed escutcheon. 136E004 rr /A ' (1) OP ACE OF FITTING TO „ WALL DIMENSION N AV i4r, �'h o. 1 1/4" MIN. 2 1/4" HOLE DIA. 1 (31. 8mm] iii l : Pl 1. n i o [57.2mm] [3 2m8 m] [107.6mm- 152.4mm] . I �• ; , - i *; ti 1'" X 1/2" REDUCER \ DEF CEIL LNECTOR G TO 1 _y_ , -\-611 -\\ -, , „ v 7 15/16" DIA. / °II 1'I 4 9.2mm n¢ uni Horizontal Sidewall [ ] ' 1114 _ II 2 27/32" DIA. 1 °.:' in [72.2mm] C TURN COLLAR UNTIL 1 TIGHT AGAINST SPRINKLER t WRENCH BOSS. f ADJUSTMENT 1 (1) REFER TO ESCUTHCEON DATA TABLE FOR APPROVALS AND DIMENSIONS 3. I A • Installation \' Quick response sprinklers are intended for installation as tle vacuuming. Remove any sprinkler which has been specified in NFPA 13, FM Global Loss Prevention Data Sheet painted (other than factory applied) or damaged in any . 2 -8N or other applicable standards. Quick response sprin- way. A stock of spare sprinklers should be maintained to klers and standard response sprinklers should not be inter- allow quick replacement of damaged or operated sprin- mixed. klers. Prior to installation, sprinklers should be maintained ` The Model F1 FR Recessed Quick Response Sprinklers are to in the original cartons and packaging until used to mini - be installed as shown. The Model F1 or F2 Escutcheons illus- mize the potential for damage to sprinklers that would trated are the only recessed escutcheons to be used with the cause improper operation or non - operation. Model F1 FR Sprinklers. The use of any other recessed escutch- Sprinkler Types eon will void all approvals and negate all warranties. Standard Upright When installing Model F1 FR Sprinklers, use the Model D Sprin- kler Wrench. When installing Model F1 FR Recessed Pendent or Standard Pendent Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any Conventional other type of wrench may damage these sprinklers. Sidewall (Vertical, Horizontal HSW1) Glass bulb sprinklers have orange bulb protectors to minimize Recessed Pendent bulb damage during shipping, handling and installation. RE- Recessed Horizontal Sidewall HSW1 MOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- Finishes ") (2) moval of the protectors before this time may leave the bulb vul- Standard Finishes nerable to damage. RASCO wrenches are designed to install Sprinkler Escutcheon sprinklers when covers are in place. REMOVE PROTECTORS Bronze Brass BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS Chrome Plated Chrome Plated (3) TO REMOVE THE PROTECTORS. White Polyester Coated White Painted (3) Temperature Ratings Special Application Finishes Sprinkler Escutcheon Sprinkler Max. Ambient Bulb Bright Brass Bright Brass Classification Temperature 9 9 °C °F Temp. Color Black Plated Black Plated Ordinary 57 135 100°F (38°C) Orange Black Paint Black Paint Ordinary 68 155 100°F (38°C) Red Off White Off White Intermediate 79 175 150 °F(66°C) Yellow Satin Chrome Satin Chrome Intermediate 93 200 150°F(66 °C) Green High (1) 141 286 225 °F(107°C) Blue ( Other finishes and colors are available on special order. (1) Consult the factory for details. Not available for recessed sprinklers. ( FM Approvals is limited to bronze and brass, chrome or black Escutcheon Data plated finishes only. , Face of (3) FP Push- on/Thread -off escutcheon. Escutcheon Approvals Adjustment "A' Fa ce (4) UL and ULC listed corrosion resistance. Model Dimension e Wall Dim ng a enor SIN numbers: R3621, R3622, R3623, R3625. 1/" Note: For X" orifice pendent FM approved white Fl 1,2,4,8 Max Recess (38.1mm) %6 " - Ys' polyester coated and UL approved white polyester Min Recess /" (5mm -24mm) corrosion resistant sprinklers refer to Bulletin 014. (19.1mm) 1 „ Ordering Information F2 1 Max Re ( Y16 "-1 /" S eClfi� Min Recess t /6 (5mm- 17mm) p 'Y (24mm) 1. Sprinkler Model FP 1,2 Max Recessed X6" 1y "(38.1mm) 2. Sprinkler Type (11mm) Push-on/ 3. Orifice Size Thread off 1,2 Min Recessed (2 4ms m) 1" (25.4mm) 4. Deflector Type No Dimensional Figure for FP 5. Temperature Rating 6. Sprinkler Finish Maintenance 7. Escutcheon Type The Models F1FR and F1FR Recessed Sprinklers 8. Escutcheon Finish (where applicable) should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean Note: When Model F1FR Recessed sprinklers are sprinklers with soap and water, ammonia or any other ordered, the sprinklers and escutcheons are packaged cleaning fluids. Remove dust by using a soft brush or gen- separately. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research e' Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by 1.0 The Reliable Automatic Sprinkler Co., Inc. ® R er lab (800)4,31-1588 Sales Offices (800)848 - 6051 Sales Fax Revision lines indicate updated or new data (914)829 -2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 3/07 P/N9999970027 [Page Too Large for OCR Processing]