Loading...
Report • 8/16/00 Activities for Case #: MST2000 -00125 2:31:10 PM i Assigned Hold. Updated , ,I Activity Description - Date 1 Date 2 Date 3 To. Done By Disp. Level By Updated Notes MSTA008 Permit Created 4/26/00 - . -GEO DONE No Hold GEO 4/26/00 t' :a MSTA005 Application received 4/21/00 DEB - RECD No Hold GEO 4/26/00 MSTA010 Check for prcl. restrict. • 4/26/00 GEO DONE No Hold GEO 4/26/00 !' MSTA012 Plans routed to Plans Examiner 4/26/00 GEO SENT No Hold GEO 4/26/00 _ MSTA026 Plans approved by Pln Examiner 4/27/00 BT2 DONE ' No Hold BT2 4/27/00 • MSTA030 Reviewed plans routed to DSTS 4/27/00 BT2 DONE No Hold BT2 4/27/00 MSTA700 Erosion 844 -8444 • No Hold BT2 4/27/00 _ MSTA705 Footing Insp ' - No Hold BT2 4/27/00 MSTA706 Foundation lnsp . 5/23/00 KBS PASS No Hold AKJ 5/23/00 MSTA710 Post/Beam Structural 6/5/00 TLP PASS No Hold AKJ 6/5/00 • MSTA711 Post/Beam Mechanical - 6/5/00 TLP PASS No Hold AKJ 6/5/00' V MSTA712 Underfloor insulation • No Hold BT2' 4/27/00 MSTA713 Crawl Drain /Backwater valve 5/25/00 • MRS PASS No Hold AKJ 5/25/00 , M.STA714 Footing /Foundation Drain No Hold BT2 4/27/00 MSTA717 PLM /Underfloor v 7/18/00 TLP PASS _No Hold TLP 7/18/00 - MSTA720 Mechanical Insp 7/14/00 RB FAIL No Hold RB 7/14/00 1. powder room- seal duct hole 2. Exhaust duct disconected. 3. Duct disconnected in bonus room. • . 4. Close lid of bonus room . chase. 5. insulate & flame spread - fireplace cavity. 6. Support wye of attic duct- ' - - - above laundry room. MSTA722 Plumb Top Out 7/3/00. TLP PASS No Hold RB 7/14/00 Reviewed card on site- Data entered by (RB). Not entered ' ' at time of inspection. MSTA723 Electrical Service 7/12/00 CD PASS No Hold CD 7/12/00 _ MSTA724 Electrical Rough. In 7/12/00 CD PASS No Hold CD 7/12/00 _ • MSTA725 Framing lnsp '`. 7/14/00 RB ,FAIL No Hold RB 7/14/00 1. Mechanical issues. 2. laminate floor joists lapped- . ' • above kitchen. •• 3. HD's missed (Pg A3 of • Plans & Pg. 40 of engineering- J Line 2). 4. No record of Plumbing U/F _ of record- Plumbing top -out ti • approved by TLP 7 -3 -00. .1 - Page 1 of 2 ' IN 8/16/00 Activities for Case #: MST2000 -00125 2:31:10 PM • Assigned Hold Updated • Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA726 Shear Wall Insp 7/7/00 HAP FAIL No Hold HAP 7/7/00 Install truss blocking and roof _ 1 ' sheathing edge nailing per 0 detail 4/A5 typical all trusses. OK to begin siding ... Recall exterior shear inspection.... Interior shear OK MSTA728 Low Voltage No Hold BT2 4/27/00 MSTA735 Gas Line Insp 7/14/00 RB PASS No Hold RB 7/14/00 #380720 MSTA736 Gas Fireplace No Hold BT2 4/27/00 MSTA740 Insulation Insp 7/18/00 TLP PASS No Hold TLP 7/18/00 MSTA752 Rain drain Insp 5/25/00 MRS PASS No Hold AKJ 5/25/00 MSTA760 Water Line Insp 5/25/00 MRS PASS No Hold AKJ 5/25/00 MSTA765 Appr /Sdwlk Insp MWH DONE No Hold MWH 8/15/00 1. Install weep hole pipe @ driveway. MSTA790 Electrical Final No Hold BT2 4/27/00 MSTA795 Mechanical Final No Hold BT2 4/27/00 MSTA797 Plumb Final No Hold BT2 4/27/00 MSTA798 Final inspection No Hold BT2 4/27/00 MSTA799 Building Final No Hold BT2 4/27/00 MSTA032 DST Post - Review Completed 5/3/00 KJP DONE No Hold KJP 5/3/00 MSTA080 (F) Ready to issue 5/3/00 KJP DONE No Hold KJP 5/3/00 MSTA092 (F) Issue combination permit 5/15/00 GEO DONE No Hold GEO 5/15/00 MSTA095 Issue plumbing signature form 5/16/00 SLT RECD No Hold ST 5/16/00 MSTA097 Issue electric signature form 5/19/00 SLT RECD No Hold ST 5/19/00 MSTA727 Exterior Sheathing Insp 7/11/00 RB PASS No Hold RB 7/11/00 MSTA726 Shear Wall Insp 7/11/00 RB FAIL No Hold RB 7/11/00 See Inspection Card. MSTA726 Shear Wall Insp 7/14/00 RB FAIL No Hold RB 7/14/00 HD's missed (See framing this date.) MSTA725 Framing Insp 7/18/00 TLP PASS No Hold TLP 7/18/00 MSTA725 Framing Insp 7/18/00 TLP PASS No Hold TLP 7/18/00 MSTA720 Mechanical Insp 7/18/00 TLP PASS No Hold TLP 7/18/00 MSTA093 (F) Reprint Permit 8/9/00 ZZZ DONE No Hold ZZZ 8/9/00 N • Page 2 of 2