Permit 1 n CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT II lq s COMMUNITY DEVELOPMENT Permit #: FPS2010 -00152 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 12/29/2010 Parcel: 1 S135AB00900 Jurisdiction: Tigard Site address: 10200 SW GREENBURG RD 360 Project: Ameriprise Subdivision: LINCOLN CENTER/FIVE LINCOLN Lot: 0 Project Description: Fire alarm. Contractor: CAPITOL ELECTRIC CO INC Owner: LINCOLN CENTER LLC 11401 NE MARX STREET BY SHORENSTEIN PROPERTIES LLC PORTLAND, OR 97220 555 CALIFORNIA ST 49TH FL SAN FRANCISCO, CA 94104 PHONE: 503 - 255 -9488 PHONE: FAX: 503 - 257 -7121 FEES Description Date Amount Specifics: Permit Fee - COM 12/07/2010 $102.20 12% State Surcharge - Building 12/07/2010 $12.26 Type of Use: COM Plan Review - Fire Life Safety - COM 12/07/2010 $40.88 Class of Work: ALT Type of Const: IIB Occupancy Grp: B Height: ft Stories: 5 Commercial Sprinkler System: Sprinkler Required: Sprinkler Type: Standpipe Required: Hazard: Density: 0 Design Area: 0 K Factor: 0 Commercial Fire Alarm System: Fire Alarm Required: Yes Alarm Type: Automatic Pull Station Required: Yes Smoke Detectors Req: No Battery Calcs Provided: Yes Cut Sheets Required: Yes Total $155.34 Valuations: Required Items and Reports (Conditions) Sprinkler Valuation: $0.00 Residential Square Footage: 0 Fire Alarm Valuation: $3,000.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: c Permittee Signature: \ 7 Call 50 . 5 by 7:00 a.m. for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application r Fire Protection System Received Pl FOR OFFICE USE ONLY City of Tigard `� Date/B e : i - ? �� PermitN.o.: =,/ iJ,_,(x0 ° 13125 SW Hall Blvd., Tigard, OR 9722 ► � �� - g v M Phone: 503.639.4171 -Fax: 503.598.19.A ': � ` � , Other Permit: r �� D ate /B a n R : ew i � � 0' ? , T I G A RD Inspection Line: 503.639.4175 C C ` Date Ready /By: El See Page 2 for Internet: www.ti ard - o'r. ov ` Q otified/Method: I , Su lemental Information g 0 ,� \O , '''1/1t^� ► do v��. _ PP TYPE OF WORK C W �� \ \AG REQU IRED DATA: 1 -AND 2- FAMILY DWELLING ❑ New construction ❑ Dem itfon Permit fees* are based on the value of the work performed.' Indicate the value (rounded to the nearest dollar) of all • ® Addition /alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. • Valuation: $ ❑ 1. and 2- family dwelling ® Commercial/industrial ID Accessory building ❑ Multi- family Number of bedrooms: • ❑ Master builder - ❑ Other: ' Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number,of floors: Job site address: 10200 SW Greenburg Rd: (Five- Lincoln) • • New dwelling area: square feet City/State /ZIP: Tigard., OR 97223 • , Garage /carport area: square feet Suite/bldg. /apt. no.: Ste 360 Project name: Ameriprise T.I. Covered porch area: square feet Cross street/directions to job site: -. Deck area: square feet • Other structure area: square feet REQUIRED DATA: COMMERCIAL - USE CHECKLIST Subdivi - I Lot no.: Permit fees* are based on the value of the work performed. • Indicate the value (rounded to the nearest dollar) of all • Tax map /parcelno.: equipment, materials; labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. , Install Fire Alarm Horn/Strobes & Strobes in Suite 360 Valuation: $3000 1 Existing building area: square feet New building area:' square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name: Shorenstein Realty Services Typ of construction: Address: Occupancy groups: • City/State /ZIP: Existing: ' . g ,Phone:( - ) Fax: ( ) New: - ❑ APPLICANT ❑ CONTACT PERSON NOTICE Business name: All contractors and subcontractors are required to be • Contact name: • licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: "jurisdiction in which work is being performed. If the • City/State /ZIP: applicant is exempt from licensing, the following reasons apply: Phone:( ) • - Fax::( ) . E -mail: CONTRACTOR BUILDING PERMIT FEES* Business name: Capitol Electric Company, Inc. (Please refer lo fee schedule) • • Permit fee: 102.20 Address: 11401 NE Marx Street. State surcharge -(12% of permit fee): - 12.26 City/State /ZIP: Portland, OR 97220 - . FLS plan review (40% of permit fee): 40.88 Phone:'(503) 255 -9488 Fax: (503) 255 -1966 (Due upon application.) CCB lic.: 48748 - Total permit fees: 155.34 ' . Amount received: 'Authorized signature: / - / This permit application expires if a permit is not obtained Print name: Dan Wilson, Date: 12/6/2010 within 180 days after it has been accepted as complete. * Fee methodology set by Tri-County Building Industry Service Board. 1:\Building\Permits \FPS- PermitApp.doc 03/23/06 440 -4613T(11 /02/COM/WEB) City of Tigard: Fire Protection Permit Checklist Page 2 - Supplemental Information Describe work to be done: 1.) ❑ New 2.) Modification to sprinkler heads only ® Addition ❑ 1 -10 heads: No plan review required. ❑ Alteration ❑ 11+ heads: Plan review required. ❑ Repair Number of sprinkler heads: Additional description of work Type of System (Complete A, B, C or D as applicable): A.) Commercial Sprinkler ❑ Wet ❑ Dry Additional Standpipes Information: Hazard Group Density Design Area K. Factor Sprinkler Project Valuation: $ B.) Type I - Hood Fire Suppression System Hood Project Valuation: $ C) Fire Alarm Submittal shall Battery Calculations ® Yes include: Individual Component ® Yes Cut Sheets Fire Alarm Project Valuation: $ 3,000.00 D.) Residential Sprinkler (Stand Alone System) Square Footage: Permit Fee: 0 to 2,000 $187.50 2,001 to 3,600 $232.50 3,601 to 7,200 $292.50 7,201 and greater $381.50 Sprinkler Project Square Footage: sq. ft. Fire Protection Permit Fees Project valuation subtotal (see A, B & C above): $ 3,000.00 Permit fee based on project valuation (see fee schedule): $ 102.20 Permit fee based on square footage (see D above): $ State Surcharge (12% of permit fee): $ 12.26 FLS Plan Review (40% of permit fee): $ 40.88 TOTAL: $ 155.34 Plan review requires a completed application and 2 sets of plans at submittal. Plan review fees are required at submittal. "New" fire protection systems require that plans bear the original seal of an Oregon licensed fire suppression engineer, or NICET level "3" technicians. U: \FA Jobs \zz101271 -45 Ameriprise @ 5Linclon -360\ 1 FPS- PermitApp.doc 2 • PERMIT FEE DOUBLES IF WORK HAS STARTED = WITHOUT BENEFIT OF PERMIT' - TO CALCULATE TOTAL FEE • • PERMIT FEE CALCULATION (REFER TO'TABLE) $ : 3,000.00 ROUNDED VALUATION $ 91.44 ' (BASE. FEE FOR FIRST $ .2,000.00: 'OF VALUATION) + $10.76 ($ 10.76 ; - PER . $ " : '1,000.00 $102.20 BASE PERMIT FEE + $12.26 STATE SURCHARGE = 12% OF BASE. PERMIT FEE + $4 PLAN REVIEW CHARGE = 40% OF, BASE PERMIT FEE ' $155.34 TOTAL DUE FOR THIS PERMIT EXAMPLE - • • NFPA -72 Fire Alarm System Record of Completion Date: 2/22/2011 City of Tigard Information: Permit No. FPS2010 -00152 Name of protected property: AMERIPRISE TENANT IMPROVEMENT, SUITE 360, 5- LINCOLN CENTER Address of protected property: 10200 SW GREENBURG ROAD TIGARD, OR 97223 Representative of protected property (name /phone): SHORENSTEIN REALTY SERVICES Authority having jurisdiction: City of Tigard, Building Services Address /telephone number: 13125 SW Hall Blvd. Tigard, OR 97223 (503) 639 -4171 1. Type(s) of System or Service NFPA 72, Chapter 3 -- Local If alarm is transmitted to locations(s) off premises, list where received: NFPA 72, Chapter 3 -- Emergency Voice /Alarm Service Quantity of voice /alarm channels: Single: Multiple: Quantity of speakers installed: Quantity of speaker zones: Quantity of telephones or telephone jacks included in system: NFPA 72, Chapter 5 -- Auxiliary Indicate type of connection: Local energy Shunt Parallel telephone Location of telephone number for receipt of signals: NFPA 72, Alarm: Supervisory: NFPA 72, Chapter 5 -- Proprietary If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: X NFPA 72, Chapter 5 -- Remote Station Prime contractor: SIMPLEX - GRINNELL Central station location: Means of transmission of signals from the protected premises to the central station: McCulloh Multiplex One -way radio X Digital alarm communicator Two -way radio Others Means of transmission of alarms to the public fire service communications center: (a) (b) System location: Organization name /phone Representative name /Phone Installer Capitol Electric Co. Inc. Dan W. Wilson 503 255 -9488 Supplier Capitol Electric Co. Inc. Dan W. Wilson 503 255 -9488 Service organization Capitol Electric Co. Inc. Dan W. Wilson 503 255 -9488 Location of record (as- built) drawings: Location of owners manuals: Location of test reports: A contract, dated , for test and inspection in accordance with NFPA standard(s) No(s). , dated , is in effect. 2. Record of System Installation Suite 360 Only (Fill out after installations complete and wiring checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NfPA standards as shown below, was inspected by Dan Wilson on 02/22/11 , included the devices shown below, and has been in service since 02/22/11 x NFPA 72 (2010), Chapters 1 10 12 14 17 18 23 (underline all that apply) x NFPA 70 (2008), National Electrical Code, Article 760 x Manufacturer's instructions Other (specify): Signed: 0 Date: 2/22/2011 Organization: Capitol Electric Company, Inc. 3. Record of System Operation Suite 360 Only All operational features and functions of this system were tested by Dan Wilson on 02/22/11 and found to be operating properly in accordance with the requirements of: x NFPA 72 (2007), Chapters 1 10 12 14 17 18 23 (underline all that apply) x NFPA 70 (2008), National Electrical Code, Article 760 x Manufacturer's instructions Other (specify): Signed: Dan Wilson Date: 2/22/2011 Organization: Capitol Electric Company, Inc. 4. Alarm- Initiating Devices and Circuits Suite 360 Only Quantity and class of initiating device circuits (see NFPA 72, Table 3 -5) Quantity: Style: Class: MANUAL (a) 0 Manual stations Noncoded, activating Transmitters Coded (b) Combination manual fire alarm and guard's tour coded stations. AUTOMATIC Coverage: Complete: Partial: (a) 0 Smoke detectors Ion Photo (b) 0 Duct detectors Ion Photo (c) 0 Heat detectors FT RR FT /RR RC (d) 0 Sprinkler waterflow switches: Transmitters Noncoded, activating (e) Other (list): 5.' Supervisory Signal- Initiating Devices and Circuits Suite 360 Only GUARD' S TOUR (a) Coded stations (b) Noncoded stations, activating transmitters (c) Compulsory guard tour system comprised of transmitter stations and intermediate stations Note: Combination devices are recorded under 4(b) and 5(a). SPRINKLER SYSTEM (a) Non coded valve supervisory switch at sprinkler riser (b) Non coded valve supervisory switch at sprinkler vault (c) Non coded supervisory air pressure switch at sprinkler riser (d) Site water supply level points Electric fire pump: (e) Fire pump power (f) fire pump running (g) Phase reversal Engine - driven fire pump: (h) Selector in auto position (I) Engine or control panel trouble 0) Fire pump running Engine- driven generator: (k) Selector in auto position (I) Control panel trouble (m) Transfer switches (n) Engine running Other supervisory functions(s) (specify): 6. Alarm Notification Appliances and Circuits Suite 360 Only Quantity and class (see NFPA 72, Table 3 -7) of notification appliance circuits connected to the system: Types and quantities of notification appliances installed: Quantity: 9 Style Y Class: B (a) Bells Inch (b) Speakers (c) Horns (d) Chimes (e) Other: (f) 9 Visual signals Type: ADA SYNCHRONIZED 4 with audible 5 w/o audible (g) Local annunciator 7. Signaling Line Circuits Suite 360 Only Quantity and class (see NFPA 72, Table 3 -6) of signaling line circuits connected to system: Quantity: Style: Class: 8. System Power Supplies (Notification Panel NAC 3.1) (a) Primary (main): NAC 3.1 Nominal voltage: 120 VAC Current rating: 2.5 Amps Overcurrent protection: Type: Circuit Breaker Current rating: 20 Amps Location: FLOOR 3 ELECTRIC ROOM (b) Secondary (standby): X Storage battery: Amp -hour rating: 7 Ah @ 24 VDC Calculated capacity to drive system, in hours: 2.803 Ah 24 60 Engine- driven generator dedicated to fire alarm system: Location of fuel storage: (c) Emergency or standby system used as backup to primary power supply, instead of using a secondary power supply: Emergency system described in NFPA 70, Article 700 Legally required standby system described in NFPA 70, Article 701 Optional standby system described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701 9. System Software (a) Operating system software revision level(s): N/A (b) Application software revision level(s): (c) Revision completed by: N/A (name) (firm) 6 .41... 10. Comments: Dan Wilson Capitol Electric Co., FLS Supervisor (signed) for central station or alarm service company or installation contractor /supplier (title) Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): This record of completion applies to Suite 360 Only Devices installed conform to NFPA standards. System deviations from the referenced NFPA standard(s) are: NONE Dan Wilson Capitol Electric Co., FLS Supervisor (signed) for central station or alarm service company or installation contractor /supplier (title) Upon completion of the system(s) satisfactory test(s) witnessed (if required by the authority having jurisdiction): (signed) representative of the authority having jurisdiction (title) (date)