Page No. 1 CASE HISTORY FOR CASE NO.: MST98 -0176
MIKE ELDEN & MAUREEN ELDON
• 11030 SW 78TH AVE
11/18/98
Action Description Reg/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
MSTA005 Application received / / / / 05/01/98 RECD JSD 05/01/98 DLH
MSTA008 Permit Created / / / / 05/01/98 DONE DLH 05/01/98 DLH
MSTA010 Check for prcl. restrict. / / / / 05/01/98 PASS DLH 05/01/98 DLH
MSTA012 Plans routed to Plans Examiner / / / / 05/01/98 DONE DLH 05/01/98 DLH
MSTA026 Plans approved by Pin Examiner / / / / 05/14/98 PASS RT 05/14/98 BT2
MSTA030 Reviewed plans routed to DSTS / / / / 05/14/98 PASS RT 05/14/98 BT2
MSTA032 DST Post - Review Completed / / / / 05/15/98 PASS JSD 05/15/98 JSD
MSTA080 (F) Ready to issue / / / / 05/15/98 Need PLM and ELC contractors identified. PASS JSD 06/09/98 DLH
jsd
After several "No Answer" calls to the
•
contractor, and given the fact that the
contractor's cell phone had been
disconnected, I left a message with the
owner's voicemail system at 2,40pm on
05/15/98 indicating the permit was ready
for issuance.
Received ELC contractor info on
06/09/98 -still need PLM contractor.DLH
MSTA092 (F) Issue combination permit / / / / 06/16/98 PASS B 06/16/98 DST
MSTA095 Issue plumbing signature form / / / / 08/31/98 owner N/A JMT 09/01/98 JT
MSTA097 Issue electric signature form / / . / / 06/16/98 B 09/01/98 JT
MSTA097 Issue electric signature form / / / / 09/01/98 RECD JMT 09/01/98 JT
MSTA705 Footing Insp / / / / 06/19/98 PASS KS 06/25/98 J *H
MSTA706 Foundation Insp / / / / / / 05/01/98 DLH
MSTA707 Slab Insp /. / / / 06/19/98 PASS KS 06/25/98 J *H
MSTA717 PLM /Underfloor / / / / / / 05/01/98 DLH
MSTA720 Mechanical Insp / / / / 07/16/98 Approved as noted. PASS KS 07/23/98 J *H
1. Gas piping existing.
2. Provide combustion air source at
mechanical compartment.
3. Need to adjust fabric straps.
4. Heat ducts do not restrict air flow
at attic.
MSTA722 Plumb Top Out / / / / 07/17/98 SLAB HOUSE !!!! PART RB 07/17/98 RE
2- showers ONLY
• NAIL PLATE PROTECTION
STRAP HOT -WATER HEATER- EXISTING;
RECOMMEND SEISMIC STRAP HOT -WATER
HEATER....DON'T FORGET COMBUSTION AIR
REQ'MTS.
MSTA723 Electrical Service / / / / / / 05/01/98 DLH
MSTA723 Electrical Service / / / / 07/20/98 PASS CD 07/20/98 CD
Page No. 2 CASE HISTORY FOR CASE NO.: MST98 -0176
MIKE ELDEN & MAUREEN ELDON
11030 SW 78TH AVE
11/18/98
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
MSTA724 Electrical Rough In / / / / / / 05/01/98 DLH
MSTA724 Electrical Rough In / / / / 07/20/98 check k.o. seals in panel & #4 water PASS CD 07/20/98 CD
bond on final
MSTA725 Framing Insp / / / / 07/17/98 1. Need electrical inspection. FAIL WDJ 07/17/98 WDJ
2. Strap top plates where they do not
overlap.
DO NOT INSULATE UNTIL ELECTRICAL
INSPECTION PASSES
MSTA725 Framing Insp / / / / 07/22/98 PASS WDJ 07/22/98 WDJ
MSTA726 Shear Wall Insp / / / / 07/01/98 Hold downs are installed according to PART WDJ 07/01/98 WDJ
plans in the new addition area. OK to
•
side addition.
MSTA728 Low Voltage / / / / / / 05/01/98 DLH
MSTA740 Insulation Insp / / '/ / 07/22/98 PASS WDJ 07/22/98 WDJ
MSTA752 Rain drain Insp / / / / 07/21/98 CONSULTATION: Met with contractor to TALK MS 07/21/98 J *H
decide what to do with rain drains.
Decided to run rain drains to front yard
20'of perf pipe to rock drainfield.
MSTA752 Rain drain Insp / / / / 07/22/98 req. filter over perf pipe PASS MS 07/22/98 MRS
MSTA790 Electrical Final / / / / 09/02/98 8/31/98 inspection requested. denied. PASS CD 09/03/98 J *H
remailed electrical signature form to
contractor. left a message for general
contractor. jeanne t.
090398 final inspection approved. - jean
h
MSTA790 Electrical Final / / / / 09/02/98 PASS CD 09/03/98 CD
MSTA795 Mechanical Final / / / / 07/16/98 Approved as noted: PASS KS 09/02/98 J *H
1. Gas piping existing.
2. Provide combustion air source at
mechanical compartment.
3. Need to adjust fabric straps at hat
ducts (do not restrict air flow at
attic.
Page No. 3 CASE HISTORY FOR CASE NO.: MST98 -0176'
MIKE ELDEN & MAUREEN ELDON
11030 SW 78TH AVE
11/18/98
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
MSTA795 Mechanical Final / / / / 09/02/98 Need electrical and plumbing finaled. PASS KS 09/02/98 J *H
Supporting members at garage need
(protected cover with gypsum and
firetape).
Post insulation certificate.
Provide back draft damper at range hood.
MSTA797 Plumb Final / / / / 08/31/98 dishwasher hose needs to be higher FAIL MS 08/31/98 MRS
water heater requires seperate shut off
valve
pry valve needs to run to outside
MSTA797 Plumb Final / / / / 09/02/98 need to know where pry valve terminates PART MS 09/02/98 MRS
MSTA797 Plumb Final / / / / 09/04/98 Previous correction pass. PASS GS 09/07/98 J *H
MSTA799 Building Final / / / / 09/02/98 inspection requested 8/31/98. denied. FAIL KS 09/02/98 J *H
remailed electrical signature form this
date. left message with general
contractor. jeanne t.
See mech final.
MSTA799 Building Final / / / / 09/04/98 PASS KS 09/07/98 J *H
MSTA970 Case Finaled / / / / 09/16/98 09/16/98 JT