Correspondence Oiiimipdy� �1�� �
June 20, 2005
CITY OF TIGARD � n
OREGON
Case Design Group
Carter Case "
1314 NW Irvine
Portland, OR 97209
RE: MEZZANINE/LOCKER ROOM & BATHROOM. REVIEW
Project Information
Site Permit: BUP2005 -00225 Co
• �. . „ nstruction Type: V -B :.. ...:
Tenant Name: Terex Occupancy Type: B
Address: 12805 SW 77 .. Occupant Load: 3
590 Stori: 1 sq. ft. es
Area: � � � f
The plan review was performed under the S
p p fate of Oregon Structural Specialty Code (OSSC) 2004
edition; and 2003 International Fire Code as amended by TVF &R. The submitted plans are approved
subject to the following conditions.
1. All exit doors shall be openable p ble from the inside without the use of a key or any special
knowledge or effort. 1008.1.8 OSSC
2. Doors and windows penetrating one hour wall shall be rated assemblies; doors one hour and glass
three quarter hour. OSSC 715 .
3. American with Disabilities Act (ADA): It shall be the responsibility of the Architect,
Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA
requirements for the structure. The City of Tigard reviews the plans and inspects ° the structure
only for compliance with Chapter 11 of the OSSC, which may not include all of the
requirements of the ADA.
4. Live Loads Posted: The live loads for which each floor has been designed to exceed 50 psf shall
be conspicuously posted by the owner in that part of each story in which they apply, using
durable metal signs, and it shall be unlawful to remove or deface such notices. The occupant of
thebuilding shall be responsible for keeping the actual load below the allowable limits. 1603.3
• OSSC
Deferred submittals such as Fire Alarm, Fire Sprinkler, Truss Joist Shop Drawings, etc, will be
charged a deferred submittal fee based on the valuation of the portion of the work being deferred. The
minimum fee shall be $200.00. Deferred items;
• None Listed
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
5 . u
W I
•
.
Approved Plans. 1 set of approved plans, bearing th e City of Tigard approval stamp, shall be , ,
.
'maintained on the obsite The plans shall be
j p Building inspectors .
available to the Buildm Division ms ectors't throughout
construction. ,
all phases of con
• dresses shall be provided for new buildings
Premises Identification, roved numbers or ad � or all '
APP p ngs m .' . r
such a position as to be plainly visible and legible from the street or road fronting the property.
When submitting revised drawings or additional information, please attach a copy of the enclosed City
of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and
. processing the documents.
Respect P ly
Val Henzel,
Senior Plans Examiner
•
•
•