Report Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 1-� Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Carlson Testing Inc. Phone (503) 684-3460 FAX (503) 664 -0954 Phone (503) 589 -1252 Phone (541) 330 -9155 FAX (503) 589 -1309 FAX (541) 330 -9163 March 29, 2000 T9902555.CTI RECV.JVED Permit No. BUP99 -00048 MAR 3 1 2000 FIELD INSPECTION REPORT BY: DATES COVERED: March 22, 2000 PROJECT: Duncan Building ADDRESS: 16135 SW 74th, Tigard, OR INSPECTOR: G. Seamster ICBO #5006921 -85 03- 22 -00: CTI representative was onsite and the following was noted. 1. Observed the placement of (16) 5/8" x 5" long epoxy dowels into exterior CMU wall for south and east wall balcony landings ([8] at each landing). Dowels achieved a 4" embedment, and were cleaned with a brush and compressed air. Epoxy used was Hilti Hit Hy 150 batch #100501 and expires 7/00. Epoxy was applied in accordance with ICBO and manufacturer's recommendations. Our reports pertain to the materials inspected /tested only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING, ' C. . -;. 1 r CHIEF E E C e achE OFFICER Chief Executive Officer GS /Ijm cc: John Duncan City of Tigard Building Department Nicoli Engineering & Construction Services, Inc.