Loading...
Report (641) Main Office Branch Office P.O. Box 23814 4060 Hudson Ave., NE Tigard, Oregon 97281 Salem, OR 97301 Carlson 'Testing Inc. T Phone (503) 684 -3460 Phone (503) 589 -1252 FAX (503) 684 -0954 FAX (503) 589 -1309 —7 60 ceec_tr December 27, 1999 99- 2555CTI Permit No: BUP99 -00048 DATES COVERED: December 20, 1999 PROJECT: Duncan Building ADDRESS: 16135 SW 74th, Tigard, OR INSPECTOR: G. Seamster 12- 20 -99: CTI representative was onsite and the following was noted: 1. Observed the placement of (15) 5/8" diameter x 5" long all thread epoxy dowels for angle iron stair landing support at grid lines A.1/2.3 -2.7. Holes achieved an embedment of 4 1 /2" and were cleaned with brush and air. Epoxy used was Hilti Hit Hy 150 batch #565778 and expires 6/2000. Epoxy was applied in accordance with ICBO #5193. 2. Verified installation torque value of 90 ft/Ibs for Ramset Red Head wedge anchors, 3 /4" diameter x 8 1 /2" long. Wedge anchors were installed with a minimum of 3 1 /2' embedment at second floor framing grids B/2 -3, 2 /A- A.5 and 3 /A -B. The installation torque value of 90 ft/Ibs was achieved per ICBO #4194. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, RLSO TESTING NC. cA.J 0.49—, 4 PRESIDENT Douglas W. Leach President GS /Ijm cc: John Duncan City of Tigard Building Department Nicoli Engineering & Construction Services, Inc. Main Office Branch Office P.O. Box 23814 4060 Hudson Ave., NE Inc. Tigard, Oregon 97281 Salem, OR 97301 9 Carlson Testing c Phone (503) 684 -3460 Phone (503) 589 -1252 FAX (503) 684 -0954 FAX (503) 589 -1309 December 22, 1999 #99- 2555.CTI Permit No: BUP99 -00048 SHOP INSPECTION REPORT @ Pacific Stair DATES COVERED: December 9, 1999 PROJECT: Duncan Building ADDRESS: 16135 SW 74 - Tigard, OR INSPECTOR: R. Shroyer 12- 06 -99: CTI representative was at the shop of Pacific Stair to inspect stairs 1- 1A/1 -1B and 1 -1C. All three stairs appear to conform to shop drawings (released for fab — 11/5/99), drawing #361 -S1. Landings P1 -1A, 1 -B & 1 -C on drawing 361 -LI. Landings did not have decking at this time and needed to be deburred and primed. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTIN CI INC. +° � Douglas' W '�` P �t T President RS:tkf cc: John Duncan City of Tigard Building Department Nicoli Engineering & Construction Services, Inc. Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Carlson 'Testing Inc. T Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 FAX (503) 684 -0954 FAX (503) 589 -1309 FAX (541) 330 -9163 Special Inspection FINAL SUMMARY LETTER March 31, 2000 T9902555 & G9801670 REC.-ETV-ED City of Tigard APR 0 6 2000 13125 SW Hall Blvd., Tigard, OR 97223 -8199 BY: Attn: Building Department Re: Duncan Building 16135 SW 74 Tigard, OR Permit No.: BUP99 -00048 / SIT99 -0006 Dear Sir or Madam: This is to certify that in accordance with Section 1701 of the Uniform Building Code and Chapter 24.20, Title 24, we have performed special inspection of the following item(s) per our inspection reports only: Reinforced Concrete Installation of Wedge and Epoxy Anchors Structural Masonry Structural Steel — Shop and Field All inspections and tests were performed and reported according to the requirements of Project Documents and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's design changes, approvals and verbal instructions. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Res►ectfully submitted, CA 41 ON TESTING, INC. ire 0,5 F. Hietpas •:lity Assurance Manager J :jdk cc: John Duncan Nicoli Engineering & Construction Services, Inc. P: \WORD \REPORTS \FIN LTR1T9902555G9801670