and Construction Services, Inc. d 8
Street Address: 9025 Southwest Center Street
Mailing Address: P.O. Box 23784 'Tigard, Oregon 97281
(503) 620 -2086 • FAX (503) 684 -3636
November 12, 1999
City of Tigard Carlson Testing John Duncan
AT TN: N: Hap Watkins A Sara Stone 706° SW P .Ime, w y
13125 SW Hall Blvd PO Box 23814 Beaverton, OR 97007
Tigard, OR 97223 Tigard, OR 97281
RE: Duncan Building- Noncompliance report (dated September 17, 1999)
16135 SW 74` Tigard, OR
BUP No. 99 -0048
CTI No. 99 -2555
Job Number 98 -0214
Gentlemen:
The following items were nonconformance issues developed by Carlson Testing, Inc. and noted
on the enclosed incomplete items list, dated September 20, 1999. Nicoli Engineering is
providing this report to describe the resolution of the noncompliance items.
ITEM NUMBER 1 (Resolved)
Summary: No inspection performed for the embeds at roofline of office (Ref.
Detail 1/5.2). Embeds installed.
Action: Mr. Duncan, the building owner and contractor has provided
a letter with Mill Certification (enclosed) verifying the rebar
g a dn of 4 e A.' - 5 r uczed F..rth mb2r!c
The contractor exposed several areas where the welds
between the rebar and embed plate could be inspected.
Carlson Testing visually inspected these welds and found
them to be 3/16" fillet vs. the 1 /4" fillet welds required by the
approved documents. Upon further review of our
calculations, a 3/16" fillet weld will develop the required
strength of the No. 5 bar. Therefore the existing condition is
adequate for the design requirements.
ITEM NUMBER 2 (Resolved)
Summary: Walls not consolidated
Action: Carlson Testing, Inc. performed a harmonic impact test on
the structures walls and found that is appears the grout was
consolidated in the masonry walls. Nicoli Engineering is
satisfied with the test performed and the results.
ITEM NUMBER 3 (Resolved)
Summary: Walls not inspected prior to grout.
Action: Carlson Testing, Inc. located the rebar with a metal detecting
device. Nicoli Engineering accepts the results and is
satisfied that the rebar was placed according to approved
documents.
ITEM NUMBER 4 (Resolved)
Summary: No reports for rebar inspection.
Action: Same as item 3.
ITEM NUMBER 5 (Resoiveci)
Summary: Contractor could not get vibrator into first grout lift.
Action: See item 2.
At this time the nonconformance items 1 -5 have been resolved to the satisfaction of Nicoli
Engineering.
Sincerely,
PRO 1
,
James R. Nicoli, P.E. s i1 ,
JRN /cjb
"j REGOr •
Enclosure .a'`
1;,
9 FS N\
EXPDES: 12 -31- 201)0'
f '
• Main Office Branch Office
P.O. Box 23814 4060 Hudson Ave., NE
Tigard, Oregon 97281 Salem, OR 97301
Carlson Testing, Inc. Phone (503) 684-3460 Phone (503) 589-1252
FAX (503) 684 -0954 FAX (503) 589 -1309
September 17, 1999
99 -2555. CTI
Permit No. BUP99 -00048
FIELD INSPECTION REPORT
DATES COVERED: September 16, 1999
PROJECT: Duncan Building
ADDRESS: 16135 SW 74th — Tigard, OR
INSPECTOR: G. Seamster
09- 16 -99: CTI representative was onsite for periodic inspection of structural steel and welding. The following
was noted.
1. Performed visual inspection of (8) tube steel columns. Welds inspected include base plate to tube steel
column connection and tube steel to column buckets. All welding appears to conform to details and AWS
D1.1.
2. Performed visual inspection of ledger clips at roof level of the north and south walls in warehouse area. All
welding appears to conform to details and AWS D1.1.
3. Reviewed mill certificates for rebar used for embeds, item #1 on CTI non compliance list. Contractor is in
compliance and item is signed off.
4. Need engineer approval for placement of roof line buckets with rebar embeds into CMU wall of office area.
Rebar to bucket welds have not been signed off. Also need weld detail for buckets fabricated at Emmert
Machining.
All non compliance items were brought to the attention of: John Duncan, owner.
Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced,
except in full, without prior authorization from this office.
If there are any further questions regarding this matter, please do not hesitate to contact this office.
Respectfully submitted,
2 RLSON TESTING, I• C.
/
Douglas W. L T
President
GS /Ijm
Attachment
cc: John Duncan
City of Tigard Building Dept
Nicoli Engineering & Construction Services, Inc.
99 -2555. FR
CARLSON TESTING, INC.
INCOMPLETED ITEMS LIST (NCL)
September 20, 1999
#99 -2555
Project Name: Duncan Building
Project Address: 16135 SW 74 Tigard, OR
Permit No: BUP99 -00048
ITEM INSP. DATE DATE
# ITEM DESCRIPTION COMPLIANCE _ CTI SIGN -OFF CORRECTED
1 JH 08 -02 -99 No paper work. on embeds set Reviewed mill certificates. G. Seamster 09 -16 -99
this date. Grade 60 not A706.
2 JH 08 -06 -99 Wall this date from 0' to top were
_ not consolidated.
3 JH 08 -13 -99 Walls this date not inspected
prior to grout.
4 JH 08 -25 -99 No paper work onsite for rebar
inspection of walls from 4' to
18'.
5 JH 08 -25 -99 Contractor could not get vibrator
into first grout lift.
cc: John Duncan
City of Tigard Building Department
Nicoli Engineering & Consulting Services, Inc.
November 12, 1999
To whom it may concern:
The embedded beam seats, used at the jamb of each opening and building
corner in the Duncan Building, were constructed with four #5 (A706)
eighteen inch long pieces of rebar. Enclosed please see the specification
sheets provided by Rose City Rebar Inc. Should you have any questions,
please feel free to contact me at (503) 807 -1735. Thank you for your time
and consideration.
Sincerely,
•hn A. Duncan
'" « l . 4 ...; iJc.
DI£+; rAn.nlo a- FABRICATION'
Date: d (—
REThFGRCE`tG STEEL CERTIFICATES
I hereby certify that the material in this shipment, fabricated on run number t E.. is as shown
on the Barlist and the Heat numbers represent materials found suitable for application to ASTM A
615 - 87 on the basis of certified test results. •
BY:
C� - -_
Charles Martin, Shop Superintendent
Sold to: (j■piy-y) �.�e__#,, Job # 9q ‘ Release # /
Shipped to:
Ship
Date
Heat q a9 t /d c(
�
lid x,45
Grade
Size
Weight cP 3 F IS' 6 1
9 Affirmative Action Employer
5512A N E 105th Ave - Portland Or 97220 - (503)252 -4975 - (503)252 -9306
„ = Denote llhno,s CERTIFIED MILL TEST REPORT
bill as.... 14.11r � s' 55 - Kankakee, Illinois Steel Division
- 58 Birmingham, Alabama Steel Division 1.‘
' a 70 - Seattle, Washington Steel Division
SOLD • R S CITY RFBAR INC `� e
TO 31 •Jackson, Mississi Steel Division DATE: 5 1 8 90q.W.1 1
•
...1512-A NE 105TH AV
...151E
PORTLAND, OR 97220 -1113 BIRMINGHAM STEEL CORD
SEATTLE, WA STEEL DIVISION B.L. NO. 70-W11488
2424 SW ANDOVER
SHIP o ROSE CITY REBAR INC SEATTLE, WA. 98106- 1 1 00 LOAD NO 71700085773
TO • 5512 -A NE 105TH AVE (206) 933 -2222
e
PORTLAND, OR 97220 -1113
____� PHYSICAL TESTS CHEMICAL TESTS
HEAT NQ,• DESCRIPTION YIELD TENSILE ELONG WTI° C Mn P S SI Cu
— P.S.I. P.S.I. % IN 8” Bend DEF NI Cr /� Cb C.E.
J# : R5820
Z19914072 * SEATTLE WA STEEL D I V I S I O N 63, 270 90, 030 19. 5/. OK - -5. 3% . 26 1.25 . 011 .038 . 18 . 36 _ . 49%
29 Rebar 60'(A706/ #9A706) 436MPa 621MPa .064 .11 .12 .03 .033
ASTM A70611-95b
?19914287 SEATTLE WA STEEL DIVISION 65, 550 103, 450 10.2 OK 1 -4. 2/ . 38 1. 121.018 .043 . 2 t . 39 60 %
13 Rebar 60' (Gr•420/ #4Gr60) 452MPa 713MPa .030 . 1 . 1 8 .02
ASTM A615/A615M -96a, GR 420
99I4288 SEATTLE WA STEEL DIVISION 66, 600 100, 000 1 1 0 . 2% OK ---4. 9% 38 1. 1 9 . 017 . 044 . 24 . 4 1 . 61%
13 Rebar 60' (Gr420 / #4Gr60) 459MPa 689MPa .029 . 12 . 19 .02
ASTM A615/A615M - -96a, GR 420
)99I 4 289 SEATTLE WA STEEL DIVISION 68,000 114,600 10.2 OK -4.2% .41 1.18 .017 .042 .23 .40 .64%
13 Rebar 60' (Gr4200/44Gr60) 469MPa 790MPa .032 .12 . 18 .02
ASTM A615/ A615M -96a, GR 420
IE I DENT I F : ED STEEL_ SHIPPED TS I N FACT COMPOSED F THE H _ATS INDICATED AND I') REP "ESEN ED D'- THE
1t(I L.-ES TES ED. THE TEST RESULTS INL'.ICATED ARE A TUOI.._ TE. T RESULTS OBTA- IN SA 1PI_E5 OF S - EEL
"AT S TAKEN AND TESTED I N ACCORDANCE WITH S P E C I F I L A T I O N S , OR SAMPL _ NG, CHEM I C L RN LY S I , PHvS I CA
STING AND MEASURING. IN REBAR MATERIAL, THE AVI_RAGE SPACING AND HEIGH OF IEFOR ATIONS HAtJE BE N
ASURED AN I FOUND TO BE I N ACCORDANCE W I `H THE R I OU I REMENTS OF Ali - M A 6' 5. j
.
VERY CERTIFY THAT THE ABOVE FIGURES ARE CORRECT AS CONTAINED IN THE RECORDS OF THE CORPORATION,
MANUFACTURING PROCESSES OF THE STEEL MATERIALS IN THIS PRODUCT, INCLUDING C" E . C7L� nil —
L(ING. HAVE OCCURRED WITHIN THE UNITED STATES, IN COMPLIANCE WITH THE - ROY QUALITY ASSURANCE
RICAN" PROVISION OF fHE SURFACE TRANSPORTATION ASSISTANCE ACT OF 198?.