FINAL SUMMARY REPORT °= = �---�—
August 21, 2000 ov0 L( r-
City of Tigard
Building Department
13125 SW Hall Boulevard
Tigard, Oregon 97223 -8199
Re: Duncan Building
16135 SW 74
Tigard, Oregon
Permit No +i SIT99 Q00'6/B'UP99 -00048
CGT Project G9801670
This is to certify that we have performed special inspection of the following items related to the
above project.
• Footing excavation depth
• Placement of forms
• Backfill and compaction
• Verification of soil bearing pressure
All observations and tests were performed on an on -call basis. Based on the results of our
observations and testing, and to the best of our knowledge, the work has been completed in
general conformance with the recommendations of our geotechnical report and later project
memoranda and recommendations.
Our reports pertain to the material tested /observed only. Information contained herein is not to be
reproduced, except in full, without prior authorization from this office. If there are any further
questions regarding this matter, please do not hesitate to contact this office.
Respectfully submitted,
CARLSON GEOTECHNICAL
Brian D. Leach, E Timothy W. Blackwood, P.E., C.E.G.
Project Manager Principal Geotechnical Engineer
cc: John Duncan
Nicoli Engineering & Construction Services, Inc. — Amahmad Qayoumi, Engineer
•
•
C arlson Geotechnical Main Office Salem Office Bend Office
P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918
A Division of Carlson Testing, Inc. Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708
Geotechnical Consulting Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155
Construction Inspection and Related Tests FAX (503) 670 -9147 FAX (503) 589 -1309 FAX (541) 330 -9163
August 21, 2000
CGT No. G9801670
Permit: SIT99- 0006/BUP99 -00048
FIELD OBSERVATION REPORT
DATES COVERED: June 22, 2000
PROJECT: Duncan Building
ADDRESS: 16135 SW 74th, Tigard, OR
BY: Tim Blackwood, Brian Leach
Carlson Geotechnical (CGT) visited the site to observe site conditions of the subject building and
discuss the project with the owners, John and Jan Duncan. Tim Blackwood and Brian Leach
represented Carlson. When we arrived, we met with the Duncans.
At the time of our meeting, the building was generally complete, except interior non - structural work
such as painting. We walked the perimeter and interior of the building to look for any signs of building
distress. Our observations of the visible portions of the foundations and all the exterior walls (masonry
block walls) noted no cracks, areas of settlement, or other signs of distress or unacceptable
performance. We also observed no such features in paved and parking areas, which extended around
the building on the north and west sides of the building.
We also observed the slab -on -grade floor and interior column footings. Our observations of the column
footings did not note any indications of cracking, settlement or other signs of distress. At the time of our
observations the flooring had not yet been installed and the concrete slab was generally free of cracks.
However, in the south approximately 1 /3 to '/a of the building, there were some cracks that extended
outward from at least two of the interior column footings. There were also two or three other cracks that
crossed the floor between joints, but that were not associated with the interior columns. There was not
any significant offset associated with the cracks we observed at this time, so they are most likely not
related to the soil settlement. Mr. Duncan stated they used a different concrete supplier in this portion
of the building, that it was poured at a different time than the rest of the slab, and that the cracks
showed up right away. This also suggests the cracking is not related to the soils.
We also discussed excavation of the footings for the structure. CGT visited the project on several
occasions during footing excavation. These visits were not individually documented, but, in general,
footing excavations were 18 to 36 inches deep as documented in a follow -up field report by Brian Leach
of CGT, dated April 19, 2000. However, along the west side of the building, Mr. Duncan indicated that
the footing excavations were at least 4 feet, and as much as 5 to 6 feet deep locally. Brian concurred
with these depths. Mr. Duncan stated that crushed rock was compacted in lifts to a well -keyed state in
the footing excavations. Brian indicated that he observed the compacted rock on a part-time basis and
that, at the locations he observed, the rock was well -keyed and suitable for foundation support.
Based on our observations and discussion with the Duncans, the building does not exhibit indications of
settlement or other soils related problems and appears to have been constructed in general accordance
with the recommendations of our geotechnical report and follow -up memoranda.
•
Field Observation Report
Duncan Building
August 21, 2000
Page 2 of 2
Our reports pertain to the locations observed at the time of our visit only. Information contained herein
is not to be reproduced, except in full, without prior authorization from this office.
Respectfully submitted,
CARLSON GEOTECHNICAL
Timothy W. Blackwood, P.E. Brian
Geotechnical Department Manager Project Manager
TWB /sab
cc: City of Tigard — Mr. Bob Poskins
Nicoli Engineering and Construction Services, Inc. — Mr. Amahmad Qayoumi
•
Carlson C eotechnical Main Office Salem Office Bend Office
P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918
A Division of Carlson Testing, Inc. Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708
Geotechnical Consulting Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155
Construction Inspection and Related Tests FAX (503) 670 -9147 FAX (503) 589 -1309 FAX (541) 330 -9163
April 19, 2000
CGT #G9801670
FIELD OBSERVATION REPORT
PROJECT: Duncan Building
ADDRESS: Tigard, Oregon
PURPOSE: Review of Foundation Subgrade
WEATHER: Clear & Warm
BY: Brian Leach, E.I.
CGT engineering associate, Brian Leach, arrived on site to review the completed excavation for the
proposed foundation at the above referenced project. The excavation for the footings extended down
between 18 and 36 inches. The subgrade soils at the bottom of the excavation consisted of a hard,
brown, gravelly silt (fill). CGT probed the subgrade soils with a ' /z" steel rod. Our probing indicated that
the fill was very dense to hard with the probe penetrating less than 1 inch in any area.
CGT also reviewed the horizontal footing -to -slope setbacks along Fanno Creek. From our review of the
forms, the proposed foundation has achieved a minimum footing -to -slope setback of 20 feet.
Based on our observations and probing, the observed subgrade soils are considered suitable for support
of the proposed foundation to the design bearing pressure and have been prepared in general
accordance to the project plans and specifications and our recommendations. In addition the footing -to-
slope setbacks are considered adequate.
This report pertains to the material tested /observed within the foundation excavation only. Information
contained herein is not to be reproduced, except in full, without prior authorization from this office. If there
are any further questions regarding this matter, please do not hesitate to contact this office.
Respectfully submitted,
CARLSON GEOTC' NICAi
Brian D. Leach, E.I.
Project Manager
08/25/2000 Activities for Case-#:i0 C R,991 0 :.:
8:06:53 AM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. . Level By Updated Notes
BUPC005 Application received 02/05/1999 BON RECD GEO 02/11/1999
BUPC008 Permit created 02/11/1999 • GEO DONE GEO 02/11/1999
BUPC012 Plans routed to Plans Examiner 02/11/1999 GEO SENT GEO 02/11/1999
BUPC015 Plan Review Ltr. to Ofc. Svcs. 02/17/1999 RDP SENT RDP 02/17/1999
BUPC018 Revised Plans Received 03/31/1999 RDP APPR RDP 03/31/1999
BUPCO24 Plans Approved by CPE 03/31/1999 RDP APPR RDP 03/31/1999
BUPCO26 Approved Plans routed to DSTs 03/31/1999 RDP APPR RDP 03/31/1999
BUPC705 Foot/Found Insp NOTE • RDP 05/11/1999 There will be special
inspections for the footing
design on this project. Carlson
testing will check and approve
footing deprth, compaction, etc.
The footing design is spread
footings
BUPC707 Footing Drain 03/31/1999 05/13/1999 TLP PASS AKJ 05/13/1999 '
BUPC716 Reinf Steel Insp 03/31/1999 RDP 03/31/1999
BUPC725 Slab Insp 03/31/1999 06/16/1999 TLP PASS AKJ 06/16/1999 1st section ok •
BUPC727 Masonry Insp 03/31/1999 06/23/1999 TLP PASS AKJ 06/28/1999 special insp Carlson
BUPC740 Framing Insp 03/31/1999 03/17/2000 TLP PASS AKJ 03/19/2000 ext wall framing and insul
complete
BUPC742 Roof naiing lnsp 03/31/1999 11/19/1999 RB PASS AKJ 03/19/2000 •
B UPC750 Insulation Insp 03/31/1999 02/25/2000 TLP PASS AKJ 03/16/2000
BUPC757 Shear Wall lnsp 03/31/1999 RDP 03/31/1999
BUPC760 Gyp Board Insp 03/31/1999 03/17/2000 TLP PASS AKJ 03/19/2000 all sheetrock for entire bldg
complete
BUPC790 Appr /sdwlk lnsp 03/31/1999 RDP 03/31/1999
B UPC792 Misc. Inspection 03/31/1999 RDP 03/31/1999
BUPC802 Final Inspection 08/01/2000 RDP FAIL RDP 08/01/2000 1. Provide smoke gasketing
and rated closer on 1 hour
doors between the 'B" and
storage room.
BUPCO29 DST Post Review Completed 05/11/1999 BON DONE No Hold BON 05/11/1999 May or may not defer TI F.
BUPC090 (F) Ready to issue 05/11/1999 BON DONE No Hold BON 05/11/1999 Will need to sign owner
responsibility form before
issuing permit.
BUPC100 (F) Issue permit 05/12/1999 BON DONE No Hold BON 05/12/1999
BUPC705 Foot/Found Insp 06/08/1999 06/08/1999 06/08/1999 TLP PASS No Hold AKJ 06/08/1999 all special insp per plans, per
Carlson Testing
Page 1 of 3
08/25/2000 Activities for Case #: BUP99 -00048
8:06:53 AM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
BUPC725 Slab Insp 07/11/1999 07/11/1999 07/09/1999 HAP PASS No Hold AKJ 07/11/1999 south 1/2 slab ok
BUPC070 HOLD FOR (Note in Action Memo) 11/01/1999 TLP DONE No Hold TLP 11/01/1999 hold all inspections until all
special inspections compliance
reports signed off by testing
agency
BUPC125 Stop Work Order Placed 11/01/1999 TLP DONE No Hold TLP 11/01/1999
BUPC075 Hold Release to Issued Status 11/18/1999 TLP PASS No Hold DGW 11/19/1999 Received documentation from
CTI and Nicoli Engineering that
resolved the outstanding •
violations and /or missing
inspections. OK to proceed.
BUPC757 Shear Wall Insp 11/19/1999 11/19/1999 11/19/1999 RB FAIL No Hold RB 11/19/1999 STOP WORK ORDER
PLACED- 11 -1 -99 TLP
Unable to pwerform inspection
until removal of Stop Work. DO
NOT PROCEED WITH COVER
OR CONCEALMENT OF ANY
KIND. •
Reviewed plans w/ Contractor
and stated that he could cover
roof. Other issues RE:
Roof /Shear inspection can be
viewed from underneath.
BUPC070 HOLD for (note in activity) 02/29/2000 HAP HOLD No Hold HAP 02/29/2000 See stop work order 2/29/00 fill
into wetland buffer and fill w/o
permit.
BUPA998 Phone call (note in activity) 03/03/2000 JMT DONE No Hold JMT 03/03/2000 requested drywall inspection.
denied. stop work order in
place. called john duncan, left
message
BUPC075 Hold release to Issued 03/15/2000 AMS RELS No Hold HAP 03/16/2000 Stop Work Order released and
removed per instructions from
Julia Hajduk..AMS
BUPC757 Shear Wall Insp 03/17/2000 TLP PASS No Hold AKJ 03/19/2000 all shear blocking and strapping
per plans and specs
BUPA730 Insulation Insp 02/25/2000 TLP PASS No Hold AKJ 03/26/2000
BUPC792 Misc. Inspection 04/12/2000 AKJ RECD No Hold AKJ 04/12/2000 special report for reinforcing
steel (final summary letter) rec
from CTI
B UPC792 Misc. Inspection 04/12/2000 AKJ RECD No Hold AKJ 04/12/2000 special insp for
• concrete- compression strength
testing final summary letter rec
from CTI
B UPC792 Misc. Inspection 04/12/2000 AKJ RECD No Hold AKJ 04/12/2000 special inspection: installation
of wedge and epoxy anchors
final summary letter rec'd from
CTI
BUPC770 Structural masonry final reprt 04/12/2000 AKJ RECD No Hold AKJ 04/12/2000 final summary report rec'd from
CTI
Page 2 of 3
08/25/2000 Activities for Case #: BUP99 -00048
8:06:53 AM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
BUPC792 Misc. Inspection 04/12/2000 AKJ RECD No Hold AKJ 04/12/2000 special insp for structural steel, •
shop and field final summary
letter rec'd from CTI
•
Page 3 of 3