Permit CITY OF TIGARD � X1 DEVELOPMENT SERVICES PERMIT DATE ISSUED: 02/27/97 s \,°1 PARCEL: 2S113B -00800 SITE ADDRESS...: 16 SW 74TH AVE SUBDIVISION....: ZONING :I -P ?LOCK..........: LOT.............: Project Description: COMMERCIAL ELECTRICAL PERMIT TO RECONFIGURE FEEDERS AND CIRCUITS. PERMIT INCLUDES LOAD CALCS. SEE ELC97 -0060. - -- RESIDENTIAL UNIT - - -- -- -TEMP SRVC /FEEDERS - - -- MISCELLANEOUS 1000 SF OR LESS....: 0 0 - 200 amp.......: 0 PUMP /IRRIGATION....: 0 EACH ADD' L 500SF...: 0 201 - 400 amp.......: 0 SIGN /OUT LINE LTG..: 0 LIMITED ENERGY.....: 0 401 - 600 amp.......: 0 SIGNAL /PANEL.......: 0 MANF. HM/ SVC /FDR..: 0 601 +amps -1000 volts.,: 0 MINOR LABEL (10)...: 0 - - -- SERVICE /FEEDER - - -- - - -- BRANCH CIRCUITS -- -ADD'L INSPECTIONS-- - 0 - 200 amp......: 3 W /SERVICE,OR FEEDER: 0 PER INSPECTION : 0 201 - 400 amp...... ; 0 1st W/0 SRVC OR FDR.: 0 PER HOUR...........: 0 401 - 600 amp......: 0 EA ADD' L BRNCH CIRC: 80 IN PLANT...........: 0 601 -- 1000 amp.....: 0 PLAN REVIEW SECTION---------------- 1000+ amp /volt.....: 0, > =4 RES UNITS........: > 600 VOLT NOMINAL... :. Reconnect only.....: 0 SVC /FDR >= 225 AMPS..: CLASS AREA /SPEC OCC. : Owner: - - - - -- FEES JADCO LTD type amount by date recpt 16055 SW 74TH AVENUE PRMT $ 580.00 JMH 02/27/97 97- 290993 SPCT $ 29.00 JMH 02/27/97 97- 290993 TIGARD OR 97223 Phone #: Contractor: -- ELECTRICAL DIMENSIONS INC $ 609.00 TOTAL PO BOX 12146 3961 SW WILLAMS AVE REQUIRED INSPECTIONS PORTLAND OR 97212 Ceiling Cover Elect-'l Service Phone #: 503 -282 -7255 Wall Cover Elect' 1 Final Reg #..: 44008 This peroit is issued subject to the regulations contained in the 1 �v1. �(--� ` - Tigard Municipal Code, State of Ore. Specialty Codes axe all others mitt e enat !-ire applicable laws. All work will be done in accordance with CCC���///���/// approved plans. This perait will expire if work is not started D �, � within 18S days of issuance, or if work is suspended for pore �w1 C�/i�l (1.4 than IN da;.. I sued By _.______.- -•_ - -OWNER INSTALLATIONV ONLY __.___ -__. --- The installation is being made on property I owp,which is not intended for sale, lease, or rent. OWNER'S SIGNATURE: DATE: -- - CONTRACTOR INSTALLATION ONLY-- -- SIGNATURE OF SUPR. ELEC' N: DATE: LICENSE NO: Call for inspection - 639 -4175 . 507 46 (a ommunity Development ELECTRICAL PERMIT APPLICATION 13125 SW Hall Blvd. r Tigard, OR 97223 Planck/Rec. # ' 7- - Permit # C-cI`7 -71 / / .s '�Nil 'I Phone (503) 639 -4171 Date Issued _:..2.1 '7/ �''i '` FAX (503) 684 -7297 CITY OF TIGARD Issued by �1 /( A /f'L/Q TDD No. (503) 684 -2772 ____ Inspection (503) 639 -4175 1. Job Address: 4. Complete Fee Schedule Below: Name of Development ■ l A Dl_o l,. I I Number of Inspections per permit allowed Address 16 VO !" jm Service included: Items Cost(ea) Sum City /State/Zip Tl 414_h_11 V'G 4a. Residential - per unit 4 J 1000 sq. ft. or less 8110.00 Name (or name of business) Each portion thereof f 825.00 1 sq. ft. or portion thereof Commercial re Residential ❑ Limited Energy 825.00 Each Manufd Home or Modular 2 Dwelling Service or Feeder $68.00 2a. Contractor installation only: , 4b. Services or Feeders • 2 Electrical j _Contractor r ! I Installation, alteration, or relocation e CA 121 c...l.� 1,mea14, t �N 4 200 amps or less ? $60.00 6 2 Add - s T - w 201 amps to 400 amps $80.00 2 City 1*a ! 1 S ta t e `)i Zip 401 amps to 600 amps $120.00 2 ► . I p 601 amps to 1000 amps $180.00 2 Phone No. 2 0 2. - 1'26'5- Over 1000 amps or volts $340.00 2 Contractor's License No. PIF...,T // 711 Reconned only $50.00 Contractor's Board Reg. No. ° 9 �� T. 4c. Temporary Services or Feeders J Inst00a amps or less or relocation 2 Signature of Supr. Elec' ��/,(�� /1% 200 amps or less $50.00 2 • , 201 amps to 400 amps $75.00 2 License No. Phone No.,' -� 401 amps to 600 amps $100.00 Over 600 amps to 1000 volts 2b. For owner installations: see 'b• above. 4d. Branch Circuits Print Owner's Name New, alteration or extension per panel Address a) The fee for branch circuits with City State Zip purchase of service or feeder lee. �J /f� 2 Each branch circuit SQ $ 5.00 Phone No. b) The fee for branch circuits without The installation is being made on property 1 own which is purchase of service or feeder fee. 2 First branch circuit $35.00 2 not intended for sale, lease or rent. Each additional branch circuit $5.00 .- Owner's Signature 4e. Miscellaneous ' (Service or feeder not included) • 2 3. Plan Review section (if required): Each pump or irrigation circle $40.00 2 Each sign or outline lighting $40.00 Signal circuit(s) or a limited energy 2 Please check appropriate item and enter fee in section 5B. panel, alteration or extension $40.00 4 or more residential units in one structure M inor Labels (10) $100.00 Service and feeder 225 amps or more System over 600 volts nominal 4f. Each additional inspection over Classified area or structure containing special occupancy the allowable in any of the above as described in N.E.C. Chapter 5 , Per inspection $35.00 Per hour $55.00 In Plant $55.00 Submit 2 sets of plans with application where any of the above apply. Not required for temporary construction services. 5. Fees: NOTICE 5a. Enter total of above fees $ t All 5% Surcharge (.05 X total fees) $ d PERMITS BECOME VOID IF WORK OR CONSTRUCTION Subtotal $ AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF 5b. Enter 25% of line A for CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR Plan Review if required (Sec.3) $ A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS Subtotal $ COMMENCED. ❑ Trust Account # $ Balance Due $ (n G g woecornWJ\else/Imam • CITY OF TIGARD BUILDING INSPECTION DIVISION 24 -Hour Inspection Line: 639 -4175 Business Phone: 639 -4171 Date Requested: 7 5 9 7 A.M. P.M. MST: Location: J c if' ? 5 , 5 C- ) 77 BUP: � Tenant: �A / �� Suite: Bldg: MEC: Contractor: Phone: PLM: Owner: Phone: ELC: 7 / -c )1� 7 5'E' -e e <-7- ELR: • SIT: BUILDING BLDG (con't) PLUMBING MECHANICAL ELECTRICAL SITE Site Post/Beam Post/Beam Post/Beam Cover /Service Sewer /Storm Footing Roof UndFl/Slab Rough -In Ceiling Water Line Slab Framing Top Out Gas Line Rough -In UG Sprinlder Foundation Insulation Sewer Hood/Duct Reconnect Vault Bsmt Damp Drywall Storm Furnace Temp Service MISC. Masonry . Ceiling Rain Drain A/C UG Slab Shear /Sheath Fire Spklr /Alm Crawl/Found Dr Heat Pump Low Approved Approved Approved Approved Approved Appr /Sdwlk Not Approved Not Approved Not Approved `f proved Not Approved FINAL FINAL FINAL INAL) FINAL t e - 6( . 77 1 ; 3 ) ''- )-- / XT r 5 r 1 - 2 - 7 g r ..Z/e. a i r e--- , 7 -fin I' Pi cv (±,..) \ ) r ■ . ' iL l r.e ( ir) it)-e 0 Call for reinspection 0 Reinspection fee $ required before next inspection ` e ] 0 Unable to inspect Inspector: r' Y "l 1 , . , Lic 4, —e / g In tor: /' � � �' Date: ` '� Page of CITY OF TIGARD BUILDING INSPECTION NOTICE Inspection Line: 639 -4175 Business Phone: 639 -4171 Footing Rain Drain Cover /Service FINAL: Foundation Water Line Ceiling - Plumb. Post/Beam Mech. Shear /Sheath Framing -Mech. PIbg.Und /FIr /Slab Plbg. Top Out Insulation - Elect. Post/Beam Struct. Mech. Rough -in Gyp. Bd. -Bldg. San. Sewer Gas Line Appr /Sdwlk Reins. Other: Date: • A.M. P.M. Entry: won Address: 1 — 461. — 7_-.) 7 Tenant: - 7 — et , c4 C'!`' Ste: MST: BUP: Con /Own: MEC: PLM: ELC: '_ / l l THE FOLLOWING CORRECTIONS ARE REQUIRED: ELR: 4 �' € 1 ii�.. � s' p � f S c� &l: 4 � c S j einci ( ( ) C - . Inspector: Q' < DateJ 7 ?7 __MS APPROVED DISAPPROVED /CALL FOR REINSP. CO' CO 7 CITY OF TIGARD BUILDING INSPECTION NOTICE Inspection Line: 639 -4175 Business Phone: 639 -4171 Footing Rain Drain Cover /Service FINAL: Foundation Water Line Ceiling - Plumb. Post/Beam Mech. Shear /Sheath Framing -Mech. PIbg.Und /FIr /Slab Plbg. Top Out Insulation ec) Post/Beam Struct. Mech. Rough -in Gyp. Bd. -Bldg. San. Sewer Gas Line Appr /Sdwlk Reins. Other: Date: ( A.M. P. En Address: /6 6 77 Tenant: a Ste: MST: � c BUP: Con /Own: MEC: PLM: _ ELC: THE FOLLOWING CORRECTIONS ARE REQUIRED: ELR: • f ( f ' • 3_, 5 7<cv"-c t r? /Lei. 5 n � I . - Zia) - - Inspector /W W . G 4 -e/ del Date: y -�y APPROVED \ bISAPPROVED /CALL FOR REINSP. CF CO CITY OF TIGARD BUILDING INSPECTION NOTICE Inspection Line: 639 -4175 Business Phone: 639 -4171 Footing Rain Drain y r/ e i FINAL: Foundation Water Line Ceiling - Plumb. Post/Beam Mech. Shear /Sheath Framing -Mech. PIbg.Und /FIr /Slab Plbg. Top Out Insulation - Elect. Post/Beam Struct. Mech. Rough -in Gyp. Bd. -Bldg. San. Sewer Gas Line Appr /Sdwlk Reins. Other: � Date: A.M. / "P.M. Entry: Address: • _ � t 1� Tenant: 9ad_ Ste: MST: BUP: Con /Own: MEC: PLM: ELC: THE FOLLOWING CORRECTIONS ARE REQUIRED: ELR: Inspector: Date: 2 APPROVED _ DISAPPROVED /CALL FOR REINSP. CF CO CITY OF TIGARD BUILDING INSPECTION NOTICE Inspection Line: 639 -4175 Business Phone: 639 -4171 Footing Rain Drain C a - Service FINAL: Foundation Water Line 1 - 'g - Plumb. Post/Beam Mech. Shear /Sheath Framing -Mech. PIbg.Und /FIr /Slab Plbg. Top Out Insulation - Elect. Post/Beam Struct. Mech. Rough -in Gyp. Bd. -Bldg. San. Sewer Gas Line Appr /Sdwlk Reins. Other: f p� Date: l ! [! I A.M. P.M. Entry: Address: - 0 _ r LU Tenant: Ste: MST: BUP: Con /Own: MEC: PLM: ELC: THE FOLLOWING CORRECTIONS ARE REQUIRED: ELR: j • P.i� e....y 4 elt)- 7 C.- e'''' A..„- -Q- _, �• / _ i / _c_., r 7 c t r - t - .6 e_k (--7.yc\---(c- f .) c -D ra=5 e_J----,--fp. Inspector: , r• h. 1 4 1 1 / LC.4el Date: Lf--z:>^ ?7 X APPROVED DISAPPROVED /CALL FOR REINSP. CF CO V 06:. 91- Pi/ JADCO LDT 16055 S.W. 74TH TIGARD, OR ELECTRICAL LOAD * ** *EXISTING 277/480 VOLT PANEL A 5 TON HVAC UNITS -480 VOLTS @'22 AMPS X 831 - 18, 282 WATTS X 2 38,564 WATTS * ** *NEW ELECTRICAL PANELS B 5 TON HVAC UNITS 208 VOLTS @ 32 AMPS X 360 - 11, 520 WATTS X 3 34, 560 WATTS C WATER HEATER 208 VOLTS 24 AMPS X 360 - 4, 992 WATTS 4, 992 WATTS D 120 VOLT OUTLETS @ 180 WATTS EA. X 80 14, 400 WATTS 120 VOLT OUTLETS @ 1,500 WATTS EA. X 10 15, 000 WATTS E LIGHTING - -- 25, 200 WATTS X 125 % 31, 500 WATTS TOTAL 100, 452 WATTS 3 - -- 200 AMP - 3 PHASE - 4 WIRE PANELS 279 AMPS @ 208 VOLTS 360 ) 100, 452 WATTS • PNL A PNL B 200 A 209 A 150 KVA a C -14 3 10 14 III qokt-ID tt 19 200A c.. - I- 6 641 4:0 110 A 1 200 A / s.1 o 75 KVA PNLC 1 , • 200 A EXISTING EXISTING 1, 600 AMP - 277/480 VOLT -3 PHASE -4 WIRE - METER MAIN SERVICE