Loading...
Specifications VLMK Consulting Engineers ?OP 15- -= 3933 SW KELLY AVENUE, PORTLAND, OREGON 97201 -4393 `' CO C- 1 1 t0 L- ( (503) 222 -4453 / FAX (503) 248 -9263 / vlmk @ vfmk.com November 5, 1999 PRINCIPALS ALFRED H. VAN DOMELEN, P.E. MEMORANDUM JAMES E. KNAUF, P.E. GREGORY J. BLEFGEN, P.E. JOHN T BROOKS TO: Bob Poskin, CEO, Senior Plans Examiner, City of Tigard HAVLIN G. KEMP, P.E. KIMBERLY A. SCHOENFELDER FROM: John Brooks RE: Grecon Tenant Improvement — 15875 SW 74 Avenue Response to Plan Check Comments The following will address comments in your plan check dated November 1, 1999. EEn iely m ng � pliance 1. Enefgy Code Compliance forms are attached. . Glass shading coefficients: A note has been added to the plan to indicate the appropriate glass shading coefficient and U- value. The project owner /contractor will provide glass that matches existing with a 1 -inch air space. Exit Cam' e understand that you have discussed this issue with Mark Newberry and are satisfied w the - mg arrangement as indicated on the plans. 0 E. Signs .ome of the exit signs indicated in your plan check list are actually shown on the / reflected ceiling plan. For clarity, we have also indicated these exit plans on the floor plan and have added additional signs per your direction and as follows: 1. Added one exit sign with arrow at door #1 between grid "A" and "B ". 2. Additional exit signs have also been added at door "E" in grid line 2, door "E" in the warehouse at grid line "C" and one at grid line "D ". Seismic Ceiling Grid Bracing A note has been added to the detail to indicate the appropriate spacing for the seismic grid bracing. Should you need any additional information to process an approval for this permit, please give me a call. Attachment: Memorandum from Bob Poskin, City of Tigard — dated November 1, 1999 Cc: John Miller, Aspen West Contractors '`LN t, yss .,, W K:\Memos \Grecon TI Resp To Pin Chk 11 -5.Doc MEMBER . i . 1 j t. ' fi t MEMORANDUM ,440 i 4 - CITY OF TIGARD, OREGON .' I TO; Kristine Bachand • . VI-MK Engineers FROM: Bob Poskin • DATE: November 1, 1999 SUBJECT: Grecon Tenant Improvement — 15875 SW 74th Your plans for the subject proposal have been reviewed for compliance with Oregon Codes; the following items require your attention: Energy Compliance 1. Provide Oregon Non - Residential Energy Codc Forms 5a through 5c. 2. New glass shall have a U -Value of 0.54 and Shading Coefficient of 0.57, provide details. OSSC, Table 13D. (_Exits. The "B" occupancy requires (2) exits placed a distance apart to not less than 1/2 the overall diagonal distance of the area served measured ih a straight line between the center of such exits. This distance is measured from the far comer of the .urchasing area B4JP9 area to the center of the egress door_`1 between line 1 and -2,� then to the centerline of the exit door "E ", Y2 the diagonal is equal to 62 feet. Your exit exceeds this distance. Provide details. OSSC, Section �� 1004.2.5.1. rt Exits Signs send illumination l� 1. Provide an illuminated directional exit arrow at door #1 BETWEEN Grid A/13, line 2. Provide illuminated exits signs at door "E" line 2, Door "E" in the warehouse at Grid "C" lines 5 and Grid "D" line 5. Provide details. OSSC, 1003.3.8. � , Seismic Ceiling Grid Bracing Your detail should place an emphasis on the horizontal restraint points be placed not more than 12 feet on center in both . directions with the first point within 6' 0" from each walL OSSC, Standard 25 -2, section 25.212.3. Provide to revised drawings showing the required changes as setout herein. If you have questions, please call me at 639 -4171 X 392. Sincerely, Rob rt D. Poskin, CBO Senior Plans Examiner • • Nov -04 -99 05:44P P -01 DATE Ak.) /7+ TIME S 1 063 1 FROM /t^ t' ' >. 04 Nio. HVAC FAx # (503) 239 -6555 hv, INCORPORATED I `Ii r N t • T R TTT"' To .c)-t-- I N = �� / 1 OR CCB# 50897 COMPANY \ �� M l� WA L &IT HVACr 125,16 SUBJECT FAx # ( ) NO. OF PAGES S (INCLUDING THIS SHEET) • \ / / N IF ALL PAGES ARE NOT RECEIVED, PLEASE CALLUS AT (503) 239 -4822 815 S.E. Sherman Portland, OR. 97214 Nov -04 -99 05:44P r -uc Form 4a Project Name: Page: I pF SYSTEMS - GENERAL 1. Exceptions (Section 1313) O No HVAC. The building plans do not call for an HVAC system. Skip to Rem 12 below. Exceptions 0 Exception. The building or part of the building qualifies for an exception from the code HVAC See a discussion of requirements. The applicable code exception is: Section 1313, Exception . Portions of the qualifying excep- building which qualify: dons on p. 4 -14 See p. 4-14 for a ! or Complex Systems (Section 1313.2) discussion of simple Simple System. The planned HVAC system qualifies as a Simple System. If true, complete this vs. complex form (4a) and equipment efficiency worksheets as required. Form 4b is not required. systems. 0 Complex System. The planned HVAC system is a Complex System. Complete this form (4a), Form 4b and equipment efficiency worksheets as required. Exceptions 3. Economizer Cooling (Section 1313.1.2) Complex Systems 0 No Cooling. The building plans do not call for a new fan system with mechanical cooling. may claim the same 0 Complies. The new fan system has an air economizer capable of modulating outside air and exceptions allowed for Simple Systems, return dampers to provide up to 85 percent of the design supply air as outdoor air. plus three excep - 1 ' Exception - Simple Systems. The new fan system qualifies for an tion. The applicable Lions allowed in code exception is: Section 1313.1.2, Exception , or Sectio 1313.2.1. ortions of the Section 1313.1.2. Seep. 4 -15 fora building which qualify: discussion of these 0 Exception - Complex Systems. The new fan system qualifies for an exception. The applicable exceptions. code exception is: Section 1313.1.2, Exception , or 1313.3.1, Exception _ . Portions of the building which qualify: 4. Economizer Cooling - Overpreasurizing (Section 1313.1.2) a No Economizer. The building plans do not call for a new fan system with an economizer. O Complies. The drawings specifically identify a pressure relief mechanism for each fan system that will exhaust the extra air introduced by the economizer, and the economizer system is capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the load. S. System and Zone Controls (Sec. 1313.1.3.1 & 1313.1.3.2) Complies. All new HVAC systems include at least one temperature control device responding to tempreatures within the zone. O Exception. The new HVAC system qualifies for an exception from the zone control require - Exceptions ments. The applicable code exception is: Section 1313.1.3.2, Exception 1 and 2. Portions of the See a discussion of building which qualify: qualifying excep- tions on p. 4 -16. 6 Control Capabilities (Sec. 1313.1.3.2.1) cel Complies. Zone thermostats are capable of being set to the temperatures described in Sec. 1313.1.3.2.1. Where used to control both heating and cooling, zone controls shall be capable of providing a temperature range or dead band of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions 0 Exception. The building qualifies for an exception to the dead band requirements. The appli- See a discussion of cable code exception is: Section1313.1.3.2.1, Exception qualifying excep- tions on p. 4 -16. (1/96) Forms & Worksheets 4 -1 Nov -04 -99 05:45P Form 4a (cont.) Project Name: Page: 2 o F 4 SYSTEMS - GENERAL 7 Off -hour Controls - HVAC Systems (Section 1313.1.3.3) Complies. All new HVAC systems are capable of automatic setback or shutdown during periods of non -use or alternate use of the space served by the system. ❑ Exception. Equipment has full Toad heating demands of 2 kW (6,826 Btu /hr) or less and is controlled by a readily accessible manual off -hour control. 8. Off -hour Controls - Supply and Exhaust Systems (1313.1.3.3) d Complies. Plans require that outdoor air supply and exhaust systems have a means of auto- matic (either motorized or gravity damnper) volume shutoff or reduction during periods of non- use or alternate use of the space served by the system. ❑ Exception. The building qualifies for an exception to the requirement for automatic shutoff or reduction. The applicable code exception is Section 1313.1.3.1. Exception 9 Heat Pump Controls (Section 1313.1.3.4) • No Heat Pump. The plans /specs do not call for a new heat pump. ❑ Complies. All new heat pumps equipped with supplementary heaters are controlled as required in Section 1313.1.3.4. 10. Equipment Performance (Section 1313.1.4) ❑ No New HVAC Equipment. The building plans do not call for new electrical HVAC equipment, combustion heating equipment or heat - operated cooling equipment. Complies. All new HVAC equipment has efficiencies not less than those required by the code. The following equipment efficiency worksheets are attached 11. Duct Insulation (Section 1313.2.2 & 1313.3.2) ❑ No Ducts. The building plans /specs do not call for new HVAC ducts or plenums. El Simple System: Complies. The plans /specs call for a Simple System, and all exterior supply/ return air-handling-ducts and plenums and all outside air ducts are insulated as required by Sec. 1313.2.2. ❑ Complex System: Complies. The building plans /specs call for a Complex System, and all air - handling ducts and plenums are insulated as required by Sec. 1313.3.2. 12. Piping Insulation (Section 1314) Exceptions ❑ No New Piping. The building plans /specs do not call for new piping serving a heating or cooling system or part of a circulating service water heating system. See a discussion of II qualifying excep- ❑ Complies. All new piping serving a heating or cooling system or part of a circulating service lions on p. 4 -17. water heating system complies with the requirements of the Code, Section 1314.1. ❑ Exception. New piping qualifies for the following exception: Section 1314, Exception . 13. Service Water Heating (Section 1315) ❑ No New Water Heating, The building plans /specs do not call for new water heaters, hot water storage tanks, service hot water distribution systems, swimming pools or spas. Exceptions ❑ Complies. All new water heaters, hot water storage tanks, service hot water distribution sys- See a discussion of tems, swimming pools or spas comply with the requirements of the Code. qualifying excep - ❑ Exception. The applicable code exception is, Section , Exception . Portions (ions on p. 4-18. of the building which qualify: 4-2 Systems (1/96) r - �,'+ Nov -04 -99 05 : 451 • Worksheet 4a Project Name: Page: 3 o UNITAR AIR CONDITIONER - AIR COOLED Equipment (a) (b) See p. 4 -19 fora Proposed discussion of Performance equipment ratings Cooling AF \16 Seasonal Compliance and equipment Q definitions. Capacity Steady or Part Schedule Equip. ID Model Designation (Btu /h) State Load (A -E) gi - i,-- k 5 €2A 42- 31 1S ."? l0 T1.1 2 Ca ZA-o Z-4- 2`i--1 g0,1 1 o g- L1- 3 S,Z A- 042 >1 73,7 1 S T LJ - 4- Se 2 Pr Q' -S 47 ' ,1 ! 0 'KTL S 0 4 - ) 4. - 711 1 I0 • 1. Does the proposed equipment meet the required equipment efficiency? Enter "Y" if yes. 2. Check boxes to indicate the source of information: 3 ARI Unitary Directory, Section AC (Enter the page number) 0 ARI Applied Products Directory, Section ULE (Enter the page number; U' Product data (Attach data furnished by the equipment supplier) Cooling Ca acity (Btu /h) Minimum Rating Compli- ance But not Steady Seasonal or Schedule Equipment Type Over over - State Part Load Single Package 0 65,000 na 9.7 SEER A Without a 65,000 135,000 8.9 EER 8.3 IPLV Heating Section 135,000 760,000 8.5 EER 7.5 ILPV 760,000 - 8.2 EER 7.5 IPLV Split System 0 65,000 na r 10.0 SEER B Without a 65,000 135,000 8.9 EER 8.3 IPLV Heating Section 135,000 760,000 8.5 EER 7.5 IPLV 760,000 - 8.2 EER 7.3 IPLV Single. Package 0 65,000 na 9.7 SEER C With a 65,000 135,000 8.9 EER 8.3 IPLV Heating Section 135,000 760,000 8.3 EER 7.3 IPLV 760,000 - 8.0 EER 7.3 IPLV Split System 0 65,000 na 10.0 SEER D With a 65,000 135,000 8.9 EER 8.3 IPLV Heating Section 135,000 760,000 8.3 EER 7.3 IPLV 760,000 - 8.0 EER 7.3 IPLV E . Condensing Unit Only 135,000 - 9.9 EER _ 11.0 IPLV 4 -4 Systems ( 1 /96) Nov -04 -99 05:46P I-' . 05 • ARI* CAPACITIES 4 c COOLING CAPACITIES AND EFFICIENCIES UNIT 582A NOMINAL TONS STANDARD CFM N ET COOLING SEERt SOUND RATINGS" CAPACITIES (Btuh) (fiefs) 01 8040 1 600 18,000 10.0 7.5 024040 2 800 24,500 10.0 7.5 024060 030040 030060 2'h 1000 28,800 10.0 7.5 036060 3 1200 34,400 10.0 8.0 036090 • 042060 3 1400 42,000 10.0 8.0 • • 042090 048090 048115 4 1600 46,500 10.0 8.0 048130 060090 • 060115 5 2000 80,000 10.0 8.0 060130 LEGEND NOTES: Bela - Sound Levels (1 bel = 10 decibels) 1. Ratings are net values, reflecting the effects oI circulating fan db - D Bulb heat. Ratings are based on: SEER - Seasonal Energy Efficiency Ratio Cooling Standard: 80 F db, 67 F wb indoor entering -air tem- . wb - Wet Bulb perature and 95 F db outdoor entering -air temperature. 2. Before purchasing this appliance, read important energy cost and 'Air Conditioning 8 Refrigeration Institute. efficiency information available from your retailer. tRated in accordance with U.S. Government DOE (Department of Energy) test procedures andlor ARI Standard 210/89. "Tested in accordance with ARI Standard 270 -89 (not listed in ARI). HEATING CAPACITIES AND EFFICIENCIES UNIT 582A HEATING INPUT OUTPUT CAPACITY TEMPERATURE AFUE (%) (Btuh) (Btuh) RISE RANGE ( ° F) �c 018040 31,960 79.9 024040 40,000 32,400 20-50 80.1 030040 32,040 80.1 024060 47,040 35 -65 - 78.4 030060 60,000 47,040 35 -65 78.4 036060 47,220 25 -55 78.7 042060 47,220 25-55 78.7 036090 71,910 79.9 042090 71,910 79.9 048090. 90,000 70,740 40 -70 78.6 060090 70,740 78.6 048115 115,000 93,265 50-80 81.1 060115 • 048130 130,000 104,390 50 -80 80.3 060130 LEGEND • °, carp. AFUE - Annual Fuel Utilization Efficiency cio ma, Oss. • NOTE: Before purchasing this appliance, read important energy cost c UL and efficiency information available from your retailer. s and 0°po, 04- • Nov -04 -99 05:48P P.Ol DATE A101/74 TIME S �U l FROM . 7 . e HVAC FAX # (503) 239 -6555 iKC oo : Teo v e r To 3r-Ah J M11,L6 2 OR - tiVA &ICHV COMPANY ACI**125J6 1 SUBJECT FAx # ( ) NO. OF PAGES v (INCLUDING THIS SHEET) f IF ALL PAGES ARE NOT RECEIVED, PLEASE CALL US AT (503) 239-4822 815 S.E. Sherman Portland, OR. 97214 Nov -04 -99 05:48P P.02 Form 4a Project Name: Page: I OP SYSTEMS - GENERAL 1. Exceptions (Section 1313) ❑ No HVAC. The building plans do not call for an HVAC system. Skip to Item 12 below. Exceptions ❑ Exception. The building or part of the building qualifies for an exception from the code HVAC See a discussion of requirements. The applicable code exception is: Section 1313, Exception . Portions of the qualifying excep- building which qualify: lions on p. 4 -14 See p. 4-14 fora 2 i Simple or Complex Systems (Section 1313.2) discussion of simple (� Simple System. The planned HVAC system qualifies as a Simple System. If true, complete this vs. complex form (4a) and equipment efficiency worksheets as required. Form 4b is not required. systems. CJ Complex System. The planned HVAC system is a Complex System. Complete this form (4a), Form 4b and equipment efficiency worksheets as required. Exceptions 3. Economizer Cooling (Section 1313.1.2) Complex Systems ❑ No Cooling. The building plans do not call for a new fan system with mechanical cooling. may claim the same ❑ Co mplies. The new fan system has an air economizer capable of modulating outside air and exceptions allowed for Simple Systems, , � / return dampers to provide up to 85 percent of the design supply air as outdoor air. plus three excep- U Exception — Simple Systems. The new fan system qualifies for an tion. The applicable lions allowed in code exception is: Section 1313.1.2, Exception , or Sectio 1313,2.1. ortions of the Section 1313.1.2. See p. 4-15 for a building which qualify: discussion of these ❑ Exception — Complex Systems. The new fan system qualifies for an exception. The applicable exceptions. code exception is: Section 1313.1.2, Exception , or 1313.3.1, Exception , . Portions of the building which qualify: � 4 , Economizer Cooling - Overpressurizing (Section 1313.1.2) Li , No Economizer. The building plans do not call for a new fan system with an economizer. Complies. The drawings specifically identify a pressure relief mechanism for each fan system that will exhaust the extra air introduced by the economizer, and the economizer system is capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the load. 5. System and Zone Controls (Sec. 1313.1.3.1 & 1313.1.3.2) 4 Complies. All new HVAC systems include at least one temperature control device responding to tempreatures within the zone. O Exception. The new HVAC system qualifies for an exception from the zone control require - Exceptions ments. The applicable code exception is: Section 1313.1.3.2, Exception 1 and 2. Portions of the See a discussion of building which qualify: qualifying excep- tions on p. 4 -16. 6 Control Capabilities (Sec. 1313.1.3.2.1) Complies. Zone thermostats are capable of being set to the temperatures described in Sec. 1313.1.3.2.1. Where used to control both heating and cooling, zone controls shall be capable of providing a temperature range or dead band of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions ❑ Exception. The building qualifies for an exception to the dead band requirements. The appli- See a discussion of cable code exception is: Section1313.1.3.2.1, Exception qualifying excep- tions on p. 4.16. • (1/96) Forms & Worksheets 4 -1 Nov -04 -99 05:49P Form 4a (cont.) Project Name: Page: j .0F 4 SYSTEM - GENERAL 7 Off -hour Controls - HVAC Systems (Section 1313.1.3.3) Complies. All new HVAC systems are capable of automatic setback or shutdown during periods of non -use or alternate use of the space served by the system. ❑ Exception. Equipment has full Toad heating demands of 2 kW (6,826 Btu /hr) or less and is controlled by a readily accessible manual off -hour control. 8. Off -hour Controls - Supply and Exhaust Systems (1313.1.3.3) 21 Complies. Plans require that outdoor air supply and exhaust systems have a means of auto- matic (either motorized or gravity damnper) volume shutoff or reduction during periods of non - use or alternate use of the space served by the system. ❑ Exception. The building qualifies for an exception to the requirement for automatic shutoff or reduction. The applicable code exception is Section 1313.1.3.1, Exception 9 Heat Pump Controls (Section 1313.1.3.4) 3 No Heat Pump. The plans /specs do not call for a new heat pump. ❑ Complies. All new heat pumps equipped with supplementary heaters are controlled as required in Section 1313.1.3.4. 10. Equipment Performance (Section 1313.1.4) ❑ No New HVAC Equipment. The building plans do not call for new electrical HVAC equipment, combustion heating equipment or heat - operated cooling equipment. &i Complies. All new HVAC equipment has efficiencies not Tess than those required by the code. The following equipment efficiency worksheets are attached 11. Duct Insulation (Section 1313.2.2 & 1313.3.2) ❑ No Ducts. The building plans /specs do not call for new HVAC ducts or plenums. a Simple System: Complies. The plans /specs call for a Simple System, and all exterior supply/ return air- handling.ducts and plenums and all outside air ducts are insulated as required by Sec. 1313.2.2. ❑ Complex System: Complies. The building plans /specs call for a Complex System, and all air - handling ducts and plenums are insulated as required by Sec. 1313.3.2. 12. Piping Insulation (Section 1314) Exceptions 0 No New Piping. The building plans /specs do not call for new piping serving a heating or cooling system or part of a circulating service water heating system. See a discussion of Z.) C om lies. All new in serving a heating or cooling system or part of a circulating qualifying excep- P piping 9 9 9 9 Y P 9 service Lions on p. 4-17. water heating system complies with the requirements of the Code, Section 1314.1. ❑ Exception. New piping qualifies for the following exception: Section 1314, Exception . 13. Service Water Heating (Section 1315) D No New Water Heating. The building plans /specs do not call for new water heaters, hot water storage tanks, service hot water distribution systems, swimming pools or spas. Exceptions ❑ Complies. All new water heaters, hot water storage tanks, service hot water distribution sys- See a discussion of tems, swimming pools or spas comply with the requirements of the Code. qualifying excep- ❑ Exception. The applicable code exception is, Section , Exception _ . Portions r;ons on p. 4-18. of the building which qualify: • 4 -2 Systems (1/96) Nov-04-9 Ob:'4 H ' r.U4 Worksh6et 4a Project Name: Page: OF4- UNITARY AIR CONDITIONER - AIR COOLED Equipment ' (a) (b) (c) (d) See p. 4 -19 fora Proposed (e) discussion of Performance equipment ratings Cooling �YA �-�- 9 pS t Steady Seasonal Compliance and equipment Q definitions. Equip. ID Model Desi nation Capacity teady or Part Schedule 9 (Btu /h) State Load (A -E) 1Z 1 Se2AO 42- 3�2 4o -7S ,1 10 _ R - rU- Z Sa ZA-OZA- 24, 40,9 �.1 I 1-C- U - 3 S Qr 04 * 1 ifoo 7S, 7 10 R T LJ -'1- ss 2 P O r 47,000 r go 'KT 5 - 5 2. A oei- 4. ?�cx�o 1'1 10 1. Does the proposed equipment meet the required equipment efficiency? Enter "Y" if yes. 2. Check boxes to indicate the source of information: ❑ ARI Unitary Directory, Section AC (Enter the page number) ❑ ARI Applied Products Directory, Section ULE (Enter the page number; V' Product data (Attach data furnished by the equipment supplier) ■ Cooling Capacity (Btu /h) Minimum Rating Compli- ance But not Steady Seasonal or Schedule Equipment Type Over over - State Part Load Single Package 0 65,000 na 9.7 SEER A Without a 65,000 135,000 8.9 EER 8.3 IPLV Heating Section 135,000 760,000 8.5 EER 7.5 ILPV 760,000 - 8.2 EER 7.5 IPLV Split System 0 65,000 na 10.0 SEER B Without a 65,000 135,000 8.9 EER 8.3 IPLV Heating Section 135,000 760,000 8.5 EER 7.5 IPLV 760,000 - 8.2 EER 7.3 IPLV Single Package 0 65,000 na 9.7 SEER C With a 65,000 135,000 8.9 EER 8.3 IPLV Heating Section 135,000 760,000 8.3 EER 7.3 IPLV 760,000 - 8.0 EER _ 7.3 IPLV Split System 0 65,000 na 10.0 SEER 0 With a 65,000 135,000 8.9 EER 8.3 IPLV Heating Section 135,000 760,000 8.3 EER 7.3 IPLV 760,000 - 8.0 EER , 7.3 IPLV E Condensing Unit Only 135,000 - 9.9 EER 11.0 IPLV 4 -4 • Systems (,iss) 1 ivUV- L.•+ - y � =4-0r r_u • ARI° CAPACITIES ,f `-I- COOLING CAPACITIES AND EFFICIENCIES UNIT 582A NOMINAL TONS STANDARD CFM NET COOLING SEERt SOUND RATINGS CAPACITIES (Btuh) (Bela) Agfij 018040 11/2 600 18,000 10.0 7.5 024040 2 800 24,600 10.0 7.5 024060 030040 21/2 1000 28,800 10.0 7.5 030060 036060 3 1200 34,400 10.0 8.0 036090 042060 3' 1400 42,000 10.0 8.0 042090 048090 048115 4 1600 46,500 10.0 8.0 048130 060090 . 060116 5 2000 60,000 10.0 8.0 060130 LEGEND NOTES: Bela - Sound Levels (1 bel = 10 decibels) 1. Ratings are net values, reflecting the effects of circulating fan db - Dry Bulb heat. Ratings are based on: SEER - Seasonal Energy Efficiency Ratio Cooling Standard: 80 F db, 67 F wb indoor entering -air tern - wb - Wet Bub perature and 95 F db outdoor entering -air temperature.. 2. Before purchasing this appliance, read important energy cost and *Air Conditioning 8 Refrigeration Institute. efficiency information available from your retailer. tRated in accordance with U.S. Government DOE (Department of Energy) test procedures and/or ARI Standard 210/89. - Tested in accordance with ARI Standard 270 -89 (not listed in ARI). • HEATING CAPACITIES AND EFFICIENCIES UNIT 582A HEATING INPUT OUTPUT CAPACITY TEMPERATURE AFUE (%) (Btuh) (Btuh) RISE RANGE (•F) i 018040 31,960 79.9 024040 40,000 32,400 20-50 80.1 030040 32,040 80.1 024060 47,040 35 -65 - 78.4 030060 60,000 47,040 35 -65 78.4 036060 47,220 25-55 78.7 042060 47,220 25 -55 78.7 036090 71,910 79.9 042090 71,910 79.9 048090 90,000 70,740 40-70 78.6 060090 70,740 78.6 048115 115,000 93,265 50 -80 81.1 060115 048130 130,000 104,390 50 -80 80.3 060130 LEGEND •,„, � corp AFUE - Annual Fuel Utilization Efficiency o v ' NOTE: Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. YL �C o9 0o1 00 • t n