Correspondence ` LA CITY OF T1C; June 18, 1998 ®REG®Nl VLMK Engineers 3933 SW Kelly Avenue Portland, OR 97201 -4393 Attn: Kim Schoenfelder RE: Creekview Building Plan Review 15865/75 SW 74th PC #: 6- 37c/6 -38c BUP #: 98- 0227/0228 Occupancy: S1 (Shell only) Construction: VN Sprinklers: Yes Occupant Load: Area: 43739 (a)15865 = 339 - (b)15875 = 99 Allowable: 8000 (OSSC, 503.3, Exception) Area Increase: 8000 (Sep 3 sides) 16000 Sprinklers: x3 48000Total Allowable Submittal documents for the above referenced project have been reviewed for conformance with the applicable 1996 Oregon Specialty Codes and other applicable codes and standards. The following comments are noted: Building "A" and "B" IENERG , C08APANCE' v : :` , -, 1. Submit completed Energy Compliance Forms 2a, 3a, 3b, 4a through 4j, and 5a through 5c from the April 1, 1996 Revised Oregon Energy Code. r r�,�Y�.r+... «,xmr Tai ire a 5 ., A ' ... _ .. ` .r aq , :'44i :; ' p .. • X , '.' ' 1 �ACCESS1131LLTY. , ��- � 1. The environmental control (thermostat) and lighting controls shall not be located more than 54" above finished floor for accessible side reach approach or 44" for forward approach [OSSC, Section 1109.2.3.6]. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Creekview Building Plan Review PC #: 6- 37c/6 -38c BUP #: 98- 022710228 Page #2 INETANQ, L11= SAFETT1 O r f , gu 1. Provide a key box (Knox) mounted to the exterior wall 10' above finish grade and adjacent to the right side of the main entry door. The box shall contain keys to gain access as required by the Fire Marshal [UFC 902.4]. If you have any questions regarding this requirement, please contact the Fire Marshal at 526- 2502. 2. Provide Type 2 -A fire extinguishers throughout so that the travel distance to an extinguisher does not exceed 75 feet [UFC Std. 10 -1 3.2.1]. 3. Provide exit illumination having an intensity of not less than 1 foot - candle at floor level with an automatic emergency power system, such as an on -site power (1) generator or storage batteries, to operate the lighting system in the event the premises wiring system fails [OSSC, Section 1012.1 and 1012.2]. 6 4 „ p, 1- . , y ofti - ) Based on a shell only, the following fixtures will be required: 1. Building "A" : 1 Male 1 Female Both ADA accessible, Building "B" : 1 Male 1 Female Both ADA accessible. 1. Provide details on how you will comply with OSSC, Chapter 12. 1. When special inspection is required by OSSC, Section 1701, the architect or engineer of record shall prepare an inspection program which shall be submitted for approval prior to a building permit being issued [OSSC, Section 106.3.5]. A. Submit an inspection program designating the work requiring special inspection, and the agency who will be responsible for conducting the inspections [OSSC, Section 106.3.5]. B. Complete the enclosed Structural Special Inspection form designating an Approved Testing Laboratory [Line B] and signed by the owner of the project [Line D]. i. The completed form must be returned to this office before a building permit can be issued. ii. Copies of all special inspection reports shall be filed with this office continually during construction. Creekview Building Plan Review PC #: 6- 37c/6 -38c BUP #: 98- 0227/0228 Page #3 iii. A final signed report must be on file before the occupancy permit will be issued [OSSC, Section 1701.3]. 2. Provide manufacturer details on joist shown on Drawings S1 and S3. Please submit three copies of revised submittal documents and a letter indicating your response to the above comments for review. Please call me at (503) 639 -4171 if you have any questions. Sincerely, R ert Poskin, CBO SENIOR PLANS EXAMINER CITY OF TIGARD A Program for Inspection Services and/or Material Testing Date: to( l 5 ,193$ ozze City of Tigard: Plan Ck. No.41394 - f 31`Bup No. Q ,° -0 221 Sit No. Project Title: t es44,gr„ Trv■sTatic Address iSclos /i5 Stmt 74-xs Architect of Record Ph. address: Structural Engineer of Record: Qt.-mt. 0.4 e Ph. 2ZZ- 4.453 address: 313s Koug c t Potrrr oat, , or Geo- Technical Engineer of Record: Uso hst aas Ph. (VA- 8- 6 8; address: 11 Y , Sul Upt Far - �iaruo�t) Provide the following information for the testing agency chosen to provide inspection services and/or testing. Testing Agency: Ph. Fax. address Geo - Technical Agency: Ph. Fax. address The owner certifies that the above noted Agency has been employed to conduct the special inspections or observations required herein. Sinnature of Owner • Phone No. Date Print name Company name The following is a list of special inspection and/or services required by the 1996 Oregon Structural Specialty Code and Tigard's Municipal Code 14.06.010 through 14.06.040. The special inspections and/or testing services required for this project to be provided by the Testing Agency. Structural Engineer or Geo - Technical Engineer of Record are as follows: • Special Inspectors for the Testing Agency shall be qualified, to the satisfaction of the Building Official. for inspections of the particular type of construction or operation. • Special inspectors shall observe the work assigned herein for conformance with the approved plans and specifications and_ submit copies of all inspection reports and. a final signed report in accordance with OSSC. Section 1701.3 to the building official. • Structural Inspections Services and Material Testing Category - - Description of Services . Required.. Provide By Yes o: ::. 1. Concrete. OSSC, Section 1701.5.1 and Section 1903, 1904 and 1905 a. Review concrete mix designs C..... 11`, n ®e•1ll S b. Inspect ,the placing of reinforced concrete riL� p r P�s.Jays) 'C C Observe the taking of test specimens. C;r« e yc. d. ucjuga". t gb1 ►a.F be &so 'D ,a- }( - 2. Bolts Installed in concrete. OSSC, Section 1701.5.2 a Prior to and during the placement of concrete around bolts when stresses permitted by section 1925 are utilized. b. 3. Special Moment - resisting Frame. OSSC, Section 1701.5.3 and section 1921.9 a Provide continuous inspection of the placement of reinforcing steel and concrete, and submit a certificate indicating compliance. b. 4. Reinforcing Steel and Pre - Stressing Steel Tendons. OSSC, Section 1701.5.4 a. Inspection of reinforcing steel and pre stressing tendons before stressing and grouting of tendons in pre stressed concrete b. Observe and record results of all tendon stressing in pre stressed concrete. C. Observe grouting of all tendons in pre stressed concrete d. 5. Structural Welding. OSSC, Section 1701.5.5 and Section 1703 a Observe the welding of any member or connection designed to resist loads and forces required by the OSSC. b Visually inspect floor and roof deck welding. C Visually inspect welded studs when used for structural diaphragm or composite systems. (shear walls) r J( ` d Visually inspect welding of stairs and railing systems. e Check certification of welders doing work on site. f Visually inspect the welding of studs and joist. (part of a.) Observe the welding of special moment - resisting steel frames, and g conduct non-destructive testing required by OSSC, section 1703. h. Observe the welding of reinforcing steel. Category • . • Description of Services Required Provide By Yes /No • 6. High Strength Bolting. OSSC. Section 1701.5.6 The installation of A325 and A490 bolts shall be in accordance with Chapter 22. Division IV a. Verify bolt types, diameter and installation Periodic inspection shall be in accordance with OSSC, Section 1701.6 b. c. 7. Structural Masonry. OSSC, Section 1701.5.7 and 2105 Other than fully grouted open -end hollow -unit masonry. a. Visually verify placement of masonry units, reinforcing steel, inspection of grout spaces and taking any required prisim or test specimens, and be present during all grouting operations. • For fully grouted open -end hollow -unit masonry . b Visually verify the start of laying units, placement of reinforcing steel, taking prisms or test specimens, inspect grout spaces and be present during all grouting operations. C. Verify that grout and mortar materials and proportions are in accordance with OSSC, Table 2I -A for Mortar and 21 -B for grout. d. e. 8. Spray - applied fireproofing. OSSC, Section 1701.5.10 a. Visually verify the substrate condition, thickness determination and confirm density report are all in accordance with UBC, Standard 7-6 b. 9. Piling, Drilled Piers and Caissons. OSSC, Section 1701.5.11 a. Present during driving of piles and subsequent testing, b Inspect the construction of cast -in -place drilled piles or caissons. c. Observe placing of reinforced concrete. d Observe placement of reinforcement steel e. 10. Shotcrete. OSSC, Section 1701.5.12 a. Observe taking of test specimens b. Observe the placement of all shotcrete used for structural members. Submit a statement of compliance with plans and specifications. C. Visual examination of completed shotcrete work. Submit a report of the three test specimens required. d. • SOILS Inspection Services and Materials Testing Special Grading, excavation and filling • Category Description of Services Required Provided By Yes / No 1. Footings adjacent to slopes steeper than 33 -1/3 % OSSC, Section 1806.4 a. Confirm building footings are properly set back from descending slope b. 2. Grading OSSC. Section 3309 a. Regular grading [less than 5,000 cu. yds. but considered unusual] ' " Requirements for engineered grading apply. b. Engineered grading [exceeds 5,000 cu. yds.] Submit: 1. Geo-technical engineers report and, 2. a engineering geology report. . 3. an as -built grading plan and, 4. a final report prepared by the soils engineer and, 5. the final report prepared by the geologist. C. 3. Fills OSSC, Section 3313 a. Preparation of ground. for fill on slopes exceeding 1 to 5 (20 %) • Includes benching and proper termination at the toe of the slope b. Acceptance of fill materials C. Compaction of 1111 material to minimum 90% of maximum density. 13125 SW Hall Blvd., Tigard, OR 97223 [503] 639 -n72 FAX [503] 684 -7297 1: BLDESPLLNSPI.DOC •