Loading...
Specifications i P ‘e lik q iNI•iif iuliub1uui•u I +�.1�ML�IMAPIEN D /� !�ilErwermim �i1 ✓ \ 51110116111011101 as NI i OHM - 1111111111iiiiiiiiiiiaillilaillidl N" .. and Construction rvi Se ices Inc. 9025 S.W. Center Street P.O. Box 23784 Tigard, Oregon 97223 Phone: (503) 620 -2086 Fax: (503) 684 -3636 FIRE FLOW CALCULATIONS FOR: 74th AVE. INDUSTRIAL PARK BUILDING E 15659 S.W. 74th AVE. TIGARD, OREGON .,i.Py r_ c_._(;4,;(;21, 44 4 1115 "7 ,, / / .... OREGON ., ✓ 1 0 5 \ ",� -1414S R.14\C ' T- 1 - R - %8: i 2.31 -23 CLIENT : JIM CASTILE PREPARED BY :JDA CHECKED BY : DATE : 1 • 2 2 .Oi pj PAGE 1 OF 4? :. Tualatin Valley Fire & Rescue and Beaverton Fire Department 4755 S.W. Griffith br. P.O. Box 4755 Beaverton, OR 97076 (503) 526 -2469 FAX 526 -2538 REQUIRED FIRE FLOW WORK SHEET t TO BE USED WITH FIRE FLOW CALCULATION INSTRUCTIONS Fire Dept Use Only 1) Building Name: 14' AV' FMZ / / PA - 1 L e 2) Address: 1 (0 5`l �, � . 1■ City /Co 1 f,,A D 1,4A 3) Type of Structure: (Check 1 Box) Date: ❑ I FR, II FR ❑ II One Hour, III One Hour ❑ IV Heavy Timber, V -One Hour ❑ II -N, III -N C' V -N 4) Total Building Square Footage: 4' 920 Use the largest aggregate floor area of all floors inclusive of mezzanines as defined by UBC Section 407 floor area. In Types I and II FR construction only, the three largest successive floor areas shall be used. 5) Building Fire Flow (BFF): 7') 0 from UFC Table A- III -A -1. (See handout on UFC) 6) a Single Occupancy Hazard: 1 C j t7 (BFF) X 1, 3 (Occupancy Factor) = Required Fire Flow (fill in line 8) b Multiple Occupancy Hazard: Occupancy occ sq ft _ bldg sq ft = %BA f f Occupancy occ sq ft - bldg sq ft = . %BA Occupancy occ sq ft _ bldg sq ft = %BA Occupancy occ sq ft ± bldg sq ft = %BA 7) Occupancy X Factor: % BA X gpm BFF X (occ fact) = FFfff % BA X gpm BFF X (occ fact) = FF % BA X gpm BFF X (occ fact) = FF % BA X gpm BFF X (occ fact) = FF a Required Fire Flow Work Sheet Page 2 • 8) Total Required Fire Flow: '2, 'Vi 5 9) Credited Required Fire Flow: (Use only one of lines a, b, or c) a. Multiply Line 8 by 75% for full fire alarm or b. Multiply Line 8 by 50% for automatic sprinkler protection or c. Multiply Line 8 by 25% for central station supervised automatic sprinkler protection 10) Available Fire Flow': 9 (p 0 (P f Round off numbers to nearest whole if Building Area ttt Fire Flow Example: Apartment building with garages Type V -N construction, aggregate square footage 12,000 square feet. Garages 3,500 square feet, apartments 8,500 square feet, BFF = 3,000 gpm. Apartment 5,000 ± 12,000 = 71% of BA Garages 3,500 - 12,000 = 29% of BA 71% (BA) X 3,000 gpm (BFF) X 1.0 (occ fac) = 2,130 gpm 29% (BA) X 3,000 gpm (BFF) X 1.1 (occ fac) = 959 gpm Total Required Fire Flow 3087 gpm The required fire flow of this standard is greater than 3,000 gpm, therefore, either area separation walls (see Section 22 of Fire Prevention Ordinance) complying with UBC Section 505(0 would need to be installed or one of the automatic sprinkler alternates or central station supervision alarm system as found in Section 25E (1), (2), and (3) of The Fire Prevention Ordinance. One may also upgrade the type of construction to comply. The same applications are true if required fire flow is greater than available fire flow. • 1. If single occupancy hazard, place answer on Line 8. If multiple occupancy hazard, skip to line 6b. When multiple occupancy hazards are housed within a single fire flow area, the building fire flow shall be factored out to the ratios of floor areas housing various occupancies. Each portion of the building fire flow for a given occupancy hazard shall be multiplied by the occupancy factor and then added together to produce a required fire flow. 2. This information is available from the fire district unless the building is in a newly developed area or new fire mains are to be installed. If the latter is the case, please provide engineered calculations showing estimated flows for the area. Delta Fire Inc. 14795 SW 7.* Ave. Portland, ; .Car Near 7224. (503) 620. -4020 Fa:7 _< 5C 3_) 6 FAX TRANSMISSION COVER SHEET Date: September 2, 1 997 To: Nicoll Engineering - Jim Andrews Fax: : 684 -3636 • Subject: Flow Test -Fire hydrant Sender: Sender: CJ Cathie YOU SHOULD RECEIVE 3 PAGE(S), INCLUDING THIS COVER SHEET : IF YOU DO NOT RECEIVE ALL J IIE PAGES, PLEASE CALL (503) 620 -4020. • • • _. .. lllt,u44 4062 O • CITY OF TIGARD, OREGON s . - Hydrant Flaw Test Report Location: / 7/ Test Conduced B, 5 Time i f 0 ,fr Represeutat ve oft 4z--17,77. 7/a , j" State purpose or test: Consumption rate during t . • 1um turd in test Yes No � ( ) (`, How many? ` $vdrant Bows'; A 2 A A/4 Nozzle Siam f Pitot Reading:_ 60 Die Coefficient _: a fpm ' Static B < .- psi Residual B / f../ psi Projected results 20 psi residttsti 9Ia O or i Resiidual gpm $emar kr! Location map_ t3Crh# Eiae sues and tr4t4.15Ce to nest rillecal0fr valves a xt bydrrnt branch site. rem (NO$II1). iboir Sowing hydrants - Labeis A/1- A/2 - gt3 AM,, sbo7r ka and rtgdaai - Label Submit this fo rm to the City off' +vard Bmidi rttr: t. " rw. 1.3126 SW Ers.a Blvd... Tc�ard Oregon 97223 fS0316 9 �t4 71 • • . 144. or . IA WATER Ft'_ J Outlet I. Pika 1'rx►ss ` rp - s*r' I.J * ,° In Pat � � Rasicfi�} S -- -�_ M � 4 �F�HEF.r. .. - / SAL A7 _ • cart, No. h `-- too � y� S l to r't -- E �� � '� � cif 7 'Pm ...rmilmmui,imit - __. +gym.■. --V1---41.111. , .35 111111111 1,011111 NM 1 tinft warcenv Mi -----. ao 1111111111111 11111WIr 1 ____ _ , iffiktilinlrai ilmi 1111111111111111, ill, , 7_, 70 mem an on g n om i _, „von_ in MIMI cal - tiffiliadeli171111111 11111111 _ „iiiiimummi in i an m i: _ ____. 50 111/111111•11111111/111 MI ____. „.1/11111111111111111110111111 MR .6111Vklillig wi-liiiiiin. ______ , 1.11111111 M 11111 /M111111111111 NM _____ 35 11111111111111111111111111111 -- 3° -11111011agenn �p '��� , al mew mi ,,., . .c - 1S --- +�. nQ IA' Sao nummormaill111111111111____ ____ W111111111111/1//11/ OE ---- : i__________---- 0 5 ILIN ININIUM - 7 --- --mim Ng • 1, :i C 1o 12 t I= 120 zoo ' LI' gra r 2UD4 Z40d �� eft: Tod Icso Wai01 Flow. rPrn 3� Zeoo