Loading...
Correspondence (29) 1111 I I ■ ■1111••••••••••■■1111••■ I I■ •111111111111• I ■1111■ ■•■■■■••••■••••••■■■■•■ I I 1111 •■ •• ■■■■■••••••••••••■■■•••••■ ■ •••••••••••♦••••• ■W■ ■� 11111111••••••111••••11111•••• ■ ■ �� I I I W ••• ruir m r■nnum■ ■ ■ ■ ■MEM 1 1►11 ii it 1•af-i ■1'11■■f ••• I 1111► U l\]\111 .IUPJ1 1■ ■1111 . Ylr T l� lJ!�l1R■ ■■ 1 1 MotiC9 \vl`� i■1 :�111011f I■ • fi�1Y�' ii ■liif■iiiiiY■ • • and Construction Services, Inc. 9025 Southwest Center Street ou-kj7 P.O. Box 23784 •Tigard, Oregon 97223 (503) 620 - 2086 • FAX (503) 684 -3636 September 22, 1997 City Of Tigard Building Department 13125 SW Hall Blvd. Tigard; OR 97223 Attention: Robert Poskin, C.B.O. Plans Examiner. RE: 15615 SW 74 (Bldg. A) PC #8 -51c BUP# 97 -0407 15655 SW'74 h (Bldg. B) PC #8 -52c BUP# 97 -0408 Dear Mr. Poskin: The following comments are in response to your Building Plan Review and the revisions to the documents have been "clouded." My numbered responses correlate to your numerical listing under each category. General Comment: Sheet 1.1 has been revised to show the new fire wail at the west end wail of building A due to assumed property line. 1 have also notified Web Steel and they are revising their documents which we should have in a few days. Energy Compliance: 1. Lighting energy calculations have been enclosed for your review. • Accessibility: 1. Sheets 2.1 and 2.2 have been revised to show handrails on both sides of stairs in their entirety. 2. This additional information regarding reach ranges has been noted on sheet 1.2, under the Accessibility Notes. 3. The stair nosing haye been revised see sheet 5.5. 4. "Slip Resistant" requirement has been added to the stair detail on sheet 5.5, City of Tigard - Building Department 15615 SW 74` (Bldg. A.) PC# 8 -51c BIJP# 97 -0407 15655 SW 74 (Bldg. B.) PC #8 -52c BUP #97 -0408 September 22, 1997 Page 2 Fire and Life Safety: 1. The existing fire extinguisher note #1 under "mechanical systems" on sheet 0.2 has been clarified to correspond with your review comments. A note regarding the fire extinguisher requirements has been added to sheet 2. -1. 2. Sheet'0.3 has been added to the documents and describes fire block •requirements. The "1 hour Fire Wall Construction" note on sheet F -1 also discusses the fire blocking requirement. 3: Sheet 0.3 has been added to the documents and describes draft stop requirements. • Structural: 1. Special inspection notes on sheet 0.2 have been updated to include field welding. it is not anticipated that field welding will be required.. A. Inspection '`program" has been enclosed for your review. B. The special inspection form has been signed and described /noted on sheet 0.2, under "special inspection program." 2. Parapet is not required per O.S.S.C., Section 709.4.1, exception no.. 4. The roof is entirely constructed out of non - combustible materials. See Web Steel drawings sheet 1\11, note #11.. 3. Please see enclosed letter requesting that the valves used be approved by the "Alternate. Materials and Methods" per O. S.. S..C., Section 104.2.8.. 4. The layout of the joist is noted on sheet 2.4. Calculations have been enclosed for the design. (125 P.S.F_.) of the second floor. 5. Web Steel provides lateral support fortheir building system only. We have designed the office spaces to be self supporting them self in a lateral event. Mechanical: 1. This requirement has been noted on sheet 0.2 under "Mechanical Systems" notes. General Note: 1. O.K. City of Tigard - Building Department 15615 SW 74 (Bldg. A.) PC# 8 -51c BUP# 97 -0407 15655 SW 74 (Bldg B.) PC# 8 -52c BUP# 97 -0408 September 22, 1997 Page 3 If you require any further information please feel free to contact me. Sincerely, aetex. James D. Andrews Project Manager JDA: j h enclosures i I II i i i , i I 0 441. and Construction Services, Inc. 9025 Southwest Center Street P.O. Box 23784•Tigard, Oregon 97223 (503) 620 -2086 • FAX (503) 684 -3636 September 18, 1997 City of Tigard Building Department 13125 SW Hall Blvd. Tigard, OR 97223 Attention: Bob Poskin, C,BrO. RE: 74 Industrial Park Building A - PC# 8-51c & BUP #, 97 -0407 15615 SW 74 Avenue Building B - PC#8-52c & BUP #97 -0408 15655 SW 74 Avenue Dear Mr. Poskin: We would like to request the design shear valves (F V' = 190) use in design of the glue - lam beams for the above noted project be allowed pursuant to the "Alternate Materials Alternate Design and Methods of Construction" of the O. S. S. C., Section 104.2.8. Please call me if you have any questions or concerns regarding this matter. Sincerely, 1 ? GA^ G James D: Andrews • - , _ PROe Project Manager �' r 11135 JDA yha_ . , G • it. 17 rEXPIRES: 12-31-98 1