Correspondence S - - ' / - 0 7 crx VIII December 30, 1999 _ }.. _ _ Nicoll Engineering TIfi "sa P.O. Box 23784 Tigard, OR 97281 OREG® RE: Meyer Building Building Plan Review 15205 SW 74 th PC #: 12 -35c SIT #: 99 -00077 Submittal documents for the above referenced project have been reviewed for conformance with the applicable 1998 Oregon Specialty Codes and other applicable codes and standards.. The follotiving comments are noted: S IE Qa » ., { Weg �� p �a s X The storm drainage plan shall adequately address the number of catch basins required to handle the parking lot and hard surface runoff. The Uniform Plumbing Specialty Code [UPSC, Section 1108] allows a maximum 6" outlet on each catch basin, and Table 11 -2 limits the maximum surface area one catch basin can serve to 7,133 square feet at 1% slope of the horizontal line from the catch basin. Additional catch basins are required to adequately serve the area. Sizing of all storm drain piping is determined by OPSC, Table 11 -2. If an engineered system is to be used in lieu of a table 11 -2, two sets of plans stamped by an engineer licensed in Oregon and the hydrodynamic calculations must be submitted for review and approval. 2. Provide details and specifications for erosion control. Include a gravel driveway approach, storm drainage protection and location of silt fencing. Contact Washington County Unified Sewerage Agency, at 799 -1639, for their technical guidelines. 3. Provide details and specifications for erosion control. Include a gravel driveway approach, storm drainage protection and location of silt fencing. Contact Washington County Unified Sewerage Agency, at 799 -1639, for their technical guidelines. 4! The parking stall north of the dumpster impedes fire department access. Remove. �- r � as ..✓y -w.r d -_:. � 6 ; t r. j ^ � "�y ", ' "x y " ��' fACCESSIBILITr1( k zw f, um,, .oz �+xe.� A .4 :6?' ; G ,x.r,. �7: . ,�- 3t� ' s.. arzYr''�m .^a �` kKA b- � ,a �4' :V: n 'e i� '.s ,F «. -kft i, 1/ Based on the building footprint, two (2) exits will be required. Show how the second exit will connect to an accessible route to a public way. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Meyer Building Building Plan Review PC #: 12 -35c BUP #: 99 -00077 Page #2 OE :b TECWHNIC*L INUESTIGATIOIV FtEP ittI W ;p • 1. Based on the Geo- Technical Report concern for the lateral displacement, we will require a letter from your Geo - Technical Engineer that he is in agreement with your structural engineer's foundation system design. This letter shall accompany your building permit application. OSSC, Section 1804. .> . 1. An elevator will be required for the second floor. See OSSC, Section 1108.3.1.1. Exception 1.6. Please submit three copies of revised submittai documents and a letter indicating your response to the above comments for review. Please call me at (503) 639 -4171 if you have any questions. Sincerely, c.461 �✓lv -rte Robert Poskin, CBO SENIOR PLANS EXAMINER is \bldg \prm sys \sit99 -00077. doc