Plans .0 �4 . ", {' : 1 , Ansul wet chemical fire suppression system, Model R -102 3 gallon cylinder. Duct: 16 "xl6" Flow point capacity: 11 Flow points used: 9 Fusible 3/8" black pipe 2W � Links \ a 360F / 10.5' Type I Hood Single Filter Bank col 1 N IN ANSUL IN 245 245 CUT OF TIGARD 35" 40" 40" Approved �� [ t� 40" 50" 50" Conditionally Approved.............. [ 1 See Letter to: Follow [ ) Remote Pull Attached 10' - 20' from hood. Permit Number: l - �t 1 Ad e ri7 & °"-- By: 4a er:lI Date: din di I I I l R Automatic gas shut to OFFICE COPY off valve. Requires manual :- Z ,. cz) Ai .- resetting. bn � Fire system drawing t o tzy -rl Front view C7 tA Guardian Fire Protection Job: Westgate Baptist Church, Notes; Fire system installed in accordance with Ansul 7 .5 w. 3 1012 SW A Avenue • : - P d, design, installation and maintenance manual. � - Corvallis OR 97333 Tigard OR 97223 System tested in accordance with UL 300. C CCB # 100355 exp. 6/12 Date: 10 /10 Drawn MAF SECTION IV — SYSTEM DESIGN UL EX3470 ULC EX3470 Page 4 -1 7 -1 -09 REV. 8 SYSTEM DESIGN GENERAL INFORMATION The ANSUL R -102 Restaurant Fire Suppression System may be 1. Nozzles must be located 2 -8 in. (5 -20 cm) into the center of the used on a number of different types of restaurant cooking appli- duct opening, discharging up. See Figure 1. ances and hood and duct configurations. The design information listed in this section deals with the limitations and parameters of 101 this pre- engineered system. Those individuals responsible for the design of the R -102 system must be trained and hold a current ANSUL certificate in an R -102 training program. The R -102 and the PIRANHA systems use compatible agents and components, therefore, they may be used together for cooking appliance, hood, and duct protection. The primary ANSUL AUTOMAN Release can be either an R -102 or a PIRANHA ANSUL AUTOMAN Release and can actuate up to two additional R -102 or PIRANHA Regulated Actuators. In systems utilizing a 11 101 remote release, any combination of the maximum number of regulated actuators can be used. 2 -8 0c (5 -20 cm) • Both systems must actuate simultaneously. • Each system must be designed and installed per its appropri- FIGURE 1 ate manual. 00013 • Adjacent appliances requiring protection must be protected 2. In installations where a UL listed damper assembly is with the same type of system, either R -102 or PIRANHA, employed, the duct nozzle can be installed beyond the 8 in. unless the center -to- center spacing between the adjacent (20 cm) maximum, to a point just beyond the damper assem- R -102 and PIRANHA nozzles is no less than 36 in. (91.4 cm). bly that will not interfere with the damper. Exceeding the maxi- • When appliances are protected with R -102 nozzles, the hood mum of 8 in. (20 cm) in this way will not void the UL listing of and connecting duct above those appliances cannot be pro- the system. tected with PIRANHA nozzles. 3. Previously listed 3 flow number and 5 flow number duct pro- • Mixing systems in a common plenum is not allowed. tection detailed in earlier published manual, Part No. 418087 - One of the key elements for restaurant fire protection is a correct 06, can also still by utilized, system design. This section is divided into ten sub - sections: Noz- DUCT SIZES UP TO 50 IN. (127 cm) zle Placement Requirements, Tank Quantity Requirements, Actu- PERIMETER/ 16 IN. (41 cm) DIAMETER ation and Expellant Gas Line Requirements, Distribution Piping Requirements, Detection System Requirements, Manual Pull Sta- • One 1W nozzle (Part No. 419336) = one flow number tion Requirements, Mechanical Gas Valve Requirements, Electri • 50 in. (127 cm) perimeter maximum cal Gas Valve Requirements, Electrical Switch Requirements, and Pressure Switch Requirements. Each of these sections must be • 16 in. (41 cm) diameter maximum completed before attempting any installation. System design sketches should be made of all aspects of design for reference DUCT SIZES UP TO 100 IN. (254 cm) during installation. PERIMETER/ 32 IN. (81.3 cm) DIAMETER NOZZLE PLACEMENT REQUIREMENTS • One 2W Nozzle (Part No. 419337) = two flow numbers This section gives guidelines for nozzle type, positioning, and • 100 in. (254 cm) perimeter maximum quantity for duct, plenum, and individual appliance protection. This • 32 in. (81.3 cm) diameter maximum section must be completed before determining tank quantity and piping requirements. The chart below shows the maximum protection available from each duct nozzle. Duct Protection — Single Nozzle Part 3.0 Gallon 1.5 Gallon All duct protection is UL listed without limitation of maximum duct Description No. System System length (unlimited length). This includes all varieties of ductworks both horizontal and vertical including ducts that run at angles to 2W Nozzle 419337 Maximum Maximum the horizontal and ducts with directional bends. 100 in. (254 cm) 100 in. (254 cm) Perimeter Perimeter The R -102 system uses different duct nozzles depending on the 1W Nozzle 419336 Maximum Maximum size of duct being protected. 50 in. (127 cm) 50 in. (127 cm) Perimeter Perimeter F} a SECTION IV — SYSTEM DESIGN UL EX3470 ULC EX3470 Page 4 -5 7 -1 -09 REV. 5 Plenum Protection . . , The R -102 system uses the 1W Nozzle (Part No. 419336) or the 1N Nozzle (Part No. 419335) for plenum protection. The 1W noz- zle tip is stamped with 1W and the 1N nozzle tip is stamped with MAX MUMcm) 1 N, indicating they are one -flow nozzles and must be counted as one flow number each. When protecting a plenum chamber, the entire chamber must be protected regardless of filter length. N. °Y . 1 IN. (2. cm) .�'�� M VERTICAL PROTECTION — GENERAL °5 'i:s, , ii • 1W NOZZLE — PART NO. 419336 — SINGLE AND "V" BANK t • PROTECTION 20 IN. (51 cm) One ,1W nozzle will protect 4 linear feet (1.2 m) of plenum. The MAXIMUM maximum distance from the end of the hood to the first and last nozzle must be no more than 2 ft (0.6 m). After the first nozzle, any t additional nozzles must be positioned at a maximum of 4 ft (1.2 m) 1 IN. (2.5 cm) apart down the entire length of the plenum.The plenum width must MINIMUM not exceed 4 ft 1.2 m). (The 1 W nozzle can be used on single or V -bank filter arrangements.) See Figure 6. FIGURE 7 9 000199 2 FT (0.6 m) MAXIMUM .. Option 2: The 1W nozzle must be placed perpendicular, 8 -12 in. MAXIMU n) (20 -30 cm) from the face of the filter and angled to the 4 FT (1.2 m) /// \4 FT (1.2 m) center of the filter. The nozzle tip must be within 2 in. oil MAXIMUM MAXIMUM 2 FT (0.6 m) (5 cm) from the perpendicular center line of the filter. MAXIMUM - � See Figure 8. /' � 12 IN. (30 cm) �� 0 . MAXIMUM ».... / Ig1 111 '/ (10 cm) --I N/ 1 I �! P B IN. (20 cm) J , MINIMUM . 10 - \ „„----"-- NOZZLE TIP MUST BE WITHIN C •��. •�� �� FIGURE 6 THIS AREA :' 000,97 ,. When protecting plenums with the 1W nozzle, two options of cov- e ` s erage are available: FIGURE 8 000200 Option 1: The 1W nozzle must be on the center line of the single or "V" bank filter and positioned within 1 -20 in. HORIZONTAL PROTECTION — OPTION 1 (2.5 -51 cm) above the top edge of the filter. See 1N NOZZLE — PART NO. 419335 — SINGLE BANK PROTECTION Figure 7. One 1N nozzle will protect 10 linear feet (3.1 m) of single filter bank plenum. The nozzle(s) must be mounted in the plenum, 2 to 4 in. (5 to 10 cm) from the face of the filter, centered between the filter height dimension, and aimed down the length. The nozzle must be positioned 0 -6 in. (0 -15 cm) from the end of the hood to the tip of the nozzle. See Figure 9. i I •. 'i' 2 - 4 IN. 10 FT. (3.1 m) (5 10 cm) MAXIMUM , lio I 00029, / ` `. 1 .., ` 000202 Z. FIGURE 9 a SECTION IV — SYSTEM DESIGN UL EX3470 ULC EX3470 Page 4 -14 REV. 6' 7 -1 -09 • Range Protection 245 (2 -Flow) Nozzle — High Proximity Application _ COOKING No Obstructions AREA ►40 in. to 50 in. (102 cm to 127 cm) above the cooking surface. This high proximity application uses the 245 nozzle, Part No. 4 419340. `M Ord MO MEI The nozzle tip is stamped with 245 indicating this is a two -flow COOKING nozzle and must be counted as two flow numbers. L A IP LOO CATION C ON CENTER OF AREA OM • One 245 nozzle will protect a maximum cooking area of 672 in.2 COOKING S • (4335 cm with a maximum longest dimension of 28 in. (71 cm). 11 3/8 IN. (29 cm) ` �` • MAXIMUM FROM When using this nozzle for range protection, the nozzle must CENTERLINE OF NOZZLE ' �® be pointed vertically down and positioned as shown in Figures TO CENTER ER GRATE ANY 29 and 30. • 245 NOZZLE TIP LOCATION COOKING CENTERLINE OF COOKING SURFACE AREA , 47i-1 \1/ KIN 0 24 NOZZLE TIP COO G 5 O AREA 50 IN. 7 m) MAXIMUM LOCATION CENTER 0�. (72 c COOKING SURFACE OR HEIGHT 11 3/8 IN. (29 cm) OF 245 MAXIMUM FROM '`- I NOZZLE CENTERLINE OF NOZZLE - - - -- TIP TO CENTER OF ANY 000766 BURNER GRATE 40 IN. cm) MIN IMUM FIGURE 30 MINIMUM 1 I HEIGHT OF 245 NOZZLE I TIP i ( 1 t t e 000236 0000 it FIGURE 29 NOTICE • Four burner grates shown in Figure 30. For sin- gle or double burner grates, locate nozzle at center of cooking surface or 11 3/8 in. (29 cm) maximum from nozzle centerline to center of any burner grate. a SECTION IV — SYSTEM DESIGN UL EX3470 ULC EX3470 Page 4 -18 REV. 7 7 -1 -09 *Griddle Protection 1N (1 -Flow) Nozzle — High Proximity • Griddle Protection 290 (2 -Flow) Nozzle — High Proximity . Application • Application ' The R -102 system uses four different nozzles for the protection of Option 1 — Nozzle Center Located griddles. One of the applications requires a 1 -flow nozzle and • 30 in. to 50 in. (76 cm to 127 cm) above the cooking surface. three of the applications require a 2 -flow nozzle. High Proximity Application: 35 in. to 40 in. (89 to 102 cm) above This high proximity application uses the 290 nozzle, Part No. 419342. the cooking surface. his high proximity application uses the 1 N nozzle, Part No. The nozzle tip is stamped with 290 indicating this is a 2 -flow noz- T19335. zle and must be counted as two flow numbers. The nozzle tip is stamped with 1N indicating this is a one flow noz • • One 290 nozzle will protect a maximum cooking area of 720 in. zle and must be counted as one flow number. (4645 cm) with a maximum dimension of 30 in. (76 cm). One 1N nozzle will protect a maximum cooking area of 1080 in.2 When using this nozzle for high proximity applications, the nozzle must rf positioned npointed td within 1 in. (2.5 down. See the Figure 41 the cook- (6968 cm with the maximum longest side of 36 in. (91 cm). 2. • ing surface and pointed vertically down. See Figure 41 and 42. - When using this nozzle for griddle protection, the nozzle must be positioned along the cooking surface perimeter to a maximum of CENTER LINE OF GRIDDLE SURFACE t 1 IN (2 cm) IN 2 in. (5 cm) inside the perimeter, and aimed to the midpoint of the ANY DIRECTION cooking surface. See Figure 39 and 40. 1 I NOTICE 1 When using this type of griddle protection, only � ' I 50 IN. 5 flow numbers are allowed on a 1.5 gal (5.7 L) I MAXIMUM system and only 11 flow numbers are allowed I HEIGHT . 41 on a 3 gal (11.4 L) system. NOZZLE TIP 1 1 3N. - I I ( �6 0I cm) —' 1 MINIMUM I— 1 HEIGHT MIDPOINT OF OF 290 I COOKING SURFACE ! I TIP ZZLE I l.4-- L— ______— ♦ J _ BSI 1 1N NOZZLE LOCATED ALONG COOKING SURFACE EDGE ANY SIDE OF GRIDDLE SURFACE • FIGURE 41 WITHIN 0 - 2 IN. (0 - 5 cm) OF 000244 COOKING SURFACE EDGE. NOZZLE MUST BE AIMED AT MIDPOINT OF COOKING COOKING SURFACE. -Q— AREA -� NOZZLE 1 IN. (2 cm) FIGURE 39 LOCATION MAXIMUM 000241 Mill 1 I I NOZZLE LOCATION 1 0 - 21N.(0 -5cm) 1 1 t I INSIDE PERIMETER I 40 IN. --e- It OF COOKING SURFACE I 1 (102 cm) 1 I MAXIMUM r i , COOKING I HEIGHT I....4 , / AREA 1 HEW NOZZLE TIP / I 35 IN. (89 cm) 1 1 IN. (2 cm) / / i 1 MINIMUM MAXIMUM 1 1 HEIGHT EDGE 1 1 1 OF 1N _..... OF —► 1 i I 1 NOZZLE TIP COOKING I 1 CENTER OF GRIDDLE SURFACE OR A SURFACE 1 1 1 ■ MAXIMUM DIMENSION OF 20.6 IN. millimmommilirm...mim■ (52 cm) FROM NOZZLE CENTERLINE TO FURTHEST CORNER OF GRIDDLE 1.1.1.11111.111.1 ■ FIGURE 42 000773 A • FIGURE 40 • 000243 • a%tv-Oo/k/ City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 October 11, 2010 • �'- :' RE: COMMERCIAL EXHAUST HOOD SUPPRESSION SYSTEM . ARO Project Information Building Permit: ANsIr 2010 -00114 Occupancy Type: A -2 Tenant Name: Westgate Baptist Construction Type: 3B Address: 10730 SW 130 Stories: 2 The plan review was performed under the State of Oregon Mechanical Specialty Code (OMSC) 2010 edition and The Oregon Fire Code 2010 edition. Each automatic fire suppression system shall have both automatic and manual actuation means. A manual activation device shall be located at or near a means of egress from the cooking area, a minimum of 10 feet and a maximum of 20 feet from the kitchen exhaust system. The manual activation device shall be located a minimum of 4 1 /2 feet and a maximum of 5 feet above the finished floor. 509.3 OMSC • The actuation of the automatic fire suppression system shall automatically shut down the fuel or electrical power supply to the cooking appliances. The fuel and electrical power supply reset shall be manual. 509.4 OMSC • A portable fire extinguisher shall be provided within a 30 foot travel distance of the cooking equipment. A Class K rated extinguisher is required if the cooking equipment involves vegetable or animal oils or fats. Section 904.11.5 OFC • Wet - chemical systems shall be inspected and tested at 6 -month intervals. Carbon Dioxide & Clean -agent systems shall be inspected and tested at 12- month intervals. Sections 904.5, 904.8 & 904.10 OFC. • A hood exhaust fan(s) shall continue to operate after the extinguishing system has been activated unless fan shutdown is required by a listed component of the ventilation system or by the design of the extinguishing system. 8.2.3.1 • All deep -fat fryers shall be installed with at least a 406 mm (16 in.) space between the fryer and surface flames from adjacent cooking equipment. 12.1.2.4 • Where a steel or tempered glass baffle plate is installed at a minimum 203 mm (8 in.) in height between the fryer and surface flames of the adjacent appliance, the requirement for a 406 mm (16 in.) space shall not apply. 12.1.2.5 • Where a building fire alarm system is installed, automatic fire - extinguishing systems shall be monitored by the building fire alarm system in accordance with NFPA 72. OFC 904.3.5 Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard - or.gov • TTY Relay: 503.684.2772 Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.6 OMSC When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Dan Nelson, Senior Plans Examiner (503)718 -2436 dann @tigard - or.com