Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Specifications
Y • , 1 i c�( Unit Feature Sheet for Seven and Half Ton Project: AutoZone 03/25/2009 Prepared By: David Ledbetter 05:06PM • _ E JUL 16 2010 Carrier CITY OF TIGARD ® BUILDING DIVISION PACKAGEDROOFTOPGASHEA11NGiELECTRICCOOLJNGUNITS 3,4,5,6,7-1/2,8-1/2,10, 12- 1/2TONS STANDARDFEATURESINCLUDE: • SEERupb13.0.EER1 11.6. - - • Singlesadloampressor ,singledreuiton3to6tons ¢ es ■----- • Dualsadlcompressors ,dualdraison7- 1/21012- 12bnsizas Upbiwostagesofcooln9,uP10stagesofhaath9 :.--- I • Acutrolrefigerantmeteringsystem - C � • Excave ASHRAEStardard62 ,sbpngdesign,sideorcenterdrain • Ambientccofngoperatingrangefromto25Fupb125F ! ° Convertiblef omverticallohor ¢onhlairficwforslabrnoun6 See-it ° °� - 0 • C ppedube,ahertinumfincofs l i Pre pairdact aria �r�edprv„eredQ,�iorpar,e�reS�Jm 1 O\� �' �� cabnet t --vb..,... �� • ExdusivelGC diagncsticswithLED \` ' s • errorcodedesignatonburner cottrolbgicardenergysavingirdocr farm delay • IMurreddrafloorrtxation wEATHERMASTERSERE:S tvvos l agasofreating 48 Utts ae 10 1, eetic • ModdsA811A7D4012areE NERGY STnRqualfied cooFg MAMDJANCEFEATURES: wil • Tvvo coohig miss They ae rabd in amine vvit AR • Tcoklessfilteraccessdoor and tt 210 (004006 sus) ati 333 (007 sues), • Beltdmee✓aporatix rswiUiacflustablep L=ys INSTALLATIONFEATURES: Sattidl • Thruthebdtornpovvensrtycapabity • Singlepdntggasardelearicconnedicr s • FullperimeterbaseraiwiIhbuilti nriggirgadaptersandfaMruckslols I S H R II E r� RELJABILITYFEATURES: r ` - Saolco rpressorsvvih finebreaka erioadproecton • 24- ,dtosntrddraritprotectedwith blecuaitbreaker COMPLIANT ENERGY STAR • Perma-entlythisated,bralyerlosed, A9 RAESTI .1 -310'3 M =04012 • E IGCa h atoperation • Sold- stateelectronicdirectsparkgnitionsysfern • FbrnerdEoutsafetyprotedor • Cyde- LOCanti-cYdecompressorprotection AcpuedenteSacty STANDARDWARRAMY: _l R —. _ • 1� i ArsII l_ .Il Ili • •r1 1 I I • 1 yearparts `' u $ fi p t lflFD n ▪ MarryoploreliPgradesa�Oava�ble (12) °''' "' "' OPT1ONSINCLUDEBUTARENOTLIMITEDTO: 004176 W7 . Premiert. inkandOpenProtocolDirectOgilalControls (DDC) • ExdcsiveHumidi- MiZeradaptivedehrmidific2 laisystem • Sc{ ardt mAuSmdeDe rs • Louveredoondtguards • Statrilessstedgasheatexcharx0er CertrfiedtoIS09001:2000 • Eccrarizer,dwornectandcawerisnceoUietcptons • I-Grgedao ssparelSandHghstabcmot ptials • COBRAEnergyRecovery • Conosionnasistantoptionsfuevaporatorandcondensercols Foraconplete6stofoptiorsanda riesreferbtheRoduciData Catabgforlhisuiit Packaged Rooftop Builder 1.19e Page 7 of 7 Performance Summary For Seven and Half Ton Project: AutoZone 03/25/2009 Prepared By: David Ledbetter 05:06PM Packaged Rooftop Builder 1.19e Page 6 of 7 ‘ i _ rformance SuMma For Seven a Half Ton Project: AutoZone ■-■ N 03/25/2119 Prepared By: David Ledbetter ` 05:06P Fan Curve 20 , 100FFM ICA - .. billhi■ 18 _ 80oRPM 16 ■ ,._ -_ __,■■�EMB.. 12 700FFA ` MEM oto,m, MEM co 10 MEEIMIENEEmi O Cil 50oRR11 1- NRIIKEI,N 4COFIN -NmmwmiMminriThm..MIENIEltlEal ELIENIIM _ 7 111111111 AIEBHP , 1 IIIMMEIM=IL.50BHP , Ril 130131 - im111111111.11111111111.1=lab16.. .116 i. 00 04 08 12 16 2) 24 28 32 40 44 Airflwv(CFM- thousands) RPM =648 BHP =1.13 MaximumRPM =1084 MaximumHP =2.90 Note: Please contactapplicationengineeringforselectionsoutsidethe shadedi egion SC- System Curve RP- RatedPoint • Packaged Rooftop Builder 1.19e Page 5 of 7 1 Performance Summary For Seven and Half Ton Project: AutoZone 03/25/2009 Prepared By: David Ledbetter 05:06PM Indoor Fan Motor Type Standard IFM Max. Continuous BHP 2.9 Indoor Fan Motor FLA 7.5 Combustion Fan Motor FLA (ea) 0.6 Power Supply MCA 38.2 Power Supply MOCP (Fuse or HACR)• 45 Min. Unit Disconnect FLA 40 Min. Unit Disconnect LRA• 242 Electrical Convenience Outlet None Acoustics Sound Rating 82.0 db Sound Power Levels, db re 10E -12 Watts Discharge Inlet Outdoor 63 Hz 97.5 94.2 62.2 125 Hz 90.2 84.3 69.3 250 Hz 76.5 70.3 71.5 500 Hz 69.5 64.9 74.7 1000 Hz 65.1 61.6 76.2 2000 Hz 63.3 56.6 72.9 4000 Hz 64.6 55.3 68.7 8000 Hz 65.7 55.4 61.5 A- Weighted 77.9 72.7 79.7 Packaged Rooftop Builder 1.19e Page 4 of 7 Performance Summary For Seven and Half Ton Project: AutoZone 03/25/2009 Prepared By: David Ledbetter 05:06PM Part Number:48HJD008-- -5 -HCA ARI EER 11.00 IPLV• 11.6 Base Unit Weight 870 lb Base Unit Dimensions Unit Length 87.4 in Unit Width 57.8 in Unit Height 41.3 in Unit Voltage-Phase-Hertz 208 -3 -60 Air Discharge Vertical Fan Drive Type Belt Actual Airflow 3000 CFM Site Altitude 285 ft Cooling Performance Condenser Entering Air DB• 80.0 F Evaporator Entering Air DB 76.6 F Evaporator Entering Air WB• 64.4 F Entering Air Enthalpy 29.62 BTU /Ib Evaporator Leaving Air DB• 56.1 F Evaporator Leaving Air WB• 54.0 F Evaporator Leaving Air Enthalpy 22.65 BTU /Ib Gross Cooling Capacity 93.24 MBH Gross Sensible Capacity 65.45 MBH Compressor Power Input 5.44 kW Coil Bypass Factor 0.110 Mixed Air Outdoor Air Airflow 420 CFM Outdoor Air DB• 80.0 F Outdoor Air WB • 67.0 F Outdoor Air Htg. Temp • 16.0 F Return Air DB • 76.0 F Return Air WB• 64.0 F Return Air Htg. Temp • 70.0 F Heating Performance Heating Airflow 3000 CFM Entering Air Temp 62.4 F Leaving Air Temp 94.4 F Gas Input Capacity 90.0 / 125.0 MBH Gas Heating Capacity 102.50 MBH Temperature Rise 32.0 F NOTE Second Stage Supply Fan External Static Pressure 0.25 in wg Fan RPM 648 Fan Power 1.13 BHP NOTE Field- supplied drive required. Electrical Data Minimum Voltage 187 Maximum Voltage' 254 Compressor RLA (ea) 12.4 Compressor LRA (ea) 88.4 Outdoor Fan FLA (ea) 1.4 Packaged Rooftop Builder 1.19e Page 3 of 7 Certified Drawing for Seven and Half Ton -; Project: AutoZone 03/25/2009 Prepared By: David Ledbetter 05:06PM UNITED ,m, ,® 00 51 1 01n a m1 �1E0 01510)5 CMM,MO wi 110110. ms w.1KS 15 .01,.5115 nc TECHNOLOGIES .,.. ... N ,. w' T ro O a„ 19 „,£P Inman T.�1a *^ B POSPOPLIPPS ,LO„K ' o� , CO CARRIER UNIT STD. UNIT ECONOMISER« ECONOMISER WEIGHT WEIGHT 0/ P.E. WEIGHT CORNER WEIGHT(A)CORNER WEIGHT(B)CORNER WEIGHT(C)CORNER WEIGHT(D) 'H" - J - 'K" 'L" o LB5. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. FT. -IN. MM FT. -IN. MM FT. -IN. MM FT. -IN. MM , 488J. /48T11.008 870 395 75 34.1 145 65.9 169 86 161 73 239 109 260 127 2' -0 7/8' 632 3' -5 5/16' 1050 2' -9 11/16' 856 2' -2 7/16' 672 48710009 680 399 191 87 163 74 242 110 264 129 1' -2 7/8' 37B 3' -5 5 /16 1050 2 -9 11/16' 856 2 -2 7/16' 672 E 48HJ0009 1015 460 I 223 101 188 65 279 126 327 149 1' -2 7/8 378 4' -1 5/16' 1253 3 3 /8 924 2• -10 7/16' 875 4814.012 /48TH.012 10M 469 1 225 102 192 87 285 129 333 151 1' -2 7/8' 378 4' -1 5/16' 1253 3' -0 3/8' 924 2 -10 7/16' f 875 -. b 4BHJ./4BTM.014 1050 476 228 103 195 88 289 131 338 153 1' -2 7/6' 378 4' -) 5 /16 1253 3' -0 3 /B' 924 2 -10 7/16' 575 NOTES, BOTTOM POWER CHART, FILTER ACCESS PANEL 1. DIMENSIONS IN ( 7 ARE IN MILLIMETERS. THESE HOLES 8EO'0 FOR USE (DISPOSABLE F LTER5) 2. ® CENTER OF GRAVITY. WITH ACCESSC47T PACKAGES - OUTSIDE AIR j, CRBI1AD1, 3/4 OR L01 I�. 3. / DIRECTION OF AIR FLOW. THREADED WIRE REB ED WIRE BED'O HOLE / 4. ON VERTICAL DISCHARGE UNITS, DUCTWORK DUCTWORK TO DE ATTACHED REAR 5 S 1/2" ALL. 7/B '[22.21 RX % /� TO ACCESSORY 800E CURB ONLY. FOR HORIZONTAL DISCHARGE 3 -4 3/8' E10253 10251 - CONDUIT SIZE USE SIZES (MAX.) 0' -3 9/16 1/2" CC. 7/8 21 UNITS FIELD SUPPLIED FLANGES SHOULD 90 ATTACHED TO FILTER /ECONOMIZER ACCESS PANEL F/ ECONOMISER. AND [901 3/4" [001,003) POKER. 1 1/8[2 HORIZONTAL DISCHARGE OPENINGS, AND ALL DUCTWORK SHQULD POWER EXHAUST 1 GOWER - 8 1 1/4' (00 ,0041POWER. 13/4 _ [44.4] BE AT ]ACTED TD THE FLANGES. CONDENSER COI -\ (003) 1/2 FPT GAS 1 1/4 [31.81 5. MINIMUM CLEARANCE (LOCAL CODES CR JURISDICTION MAY \ (004) 3/4'FPT GAS 1 5/8 PREVAIL), 3' -6 15/18 / 1 MEI o. BETWEEN UNIT FLUE 5100 AND COMBUSTIBLE SURFACES, (10911 _ . - SELECT EITHER 3/4 OR 11/4 48 INCHES. 13 INCHES WHEN USING ACCESSORY FLUE DISCHARGE DEFLECTOR. ECONOMISER. 0000 1' -6 1/2' [470] FOR POWER, DEPENDING ON WIRE SIZE. b. BOTTOM OF UNIT TO COMBUSTIBLE SURFACES 180EN NOT USING CURB) N. F/ ECONOMISER. • — 1 INCH. d l BOTTOM OF BASE RAIL TO COMBUSTIBLE SURFACES (WHEN NOT USING CORNER - A - �\ 0' -3 79) la Ln CURBS 0 INCHES. 1791 VIEW 5 - m c. CONDENSER COIL FOR PROPER AIR FLOW 36 INCHES ,.- 0 - 5 1/2' B pOCNEL O F M O ONE 510E 12 I(DHE5 Ti ff 0 THE FLOW, GETTING THE EVAPORL10Rr K 01401 GREATER CLEARANCE I5 OPTIONAL. I 1 9 m o d. OPE 0(4 60 INCHES TO ASSURE PROPER CONVERSER FAN I RETURN AIR COPENING 1 1' -0 5/8 / / //� N m o. BETWEEN UNITS, CONTROL 80X 510E 42 IN. PER NEC. 1 [3207 T. BETWEEN UNIT NA UNGROUNDED SURF NE ACES, CONTROL BOX % . © J RETURN AIR { m g 510E, 36 IN. PER NEC. g. BETWEEN UNIT AND BLOCK OR CONCRETE WALLS AND OTHER 1 { m b. HORIZONTAL SUPPLY' AND RETURNOETV 0 I WREN THE 4 [14071 4 ALT. CONDENSATE - - - - 9 1_ 0' -2 9/16' n1�5776" m o ALTERNATE CONDENSATE DRAIN 15 USED. . DRAIN OPENING [65] (-> N 6. WITH THE EXCEPTION OF THE CLEARANCE FOR THE CONDEN5ER IN BASEPAN SUPPLY COIL AND COMB]STION SIDE AS STATED IN NOTE 05., b, LEFT SEE NOTE .8 AIR 2 -4 3/4' O AND c, A REMOVABLE FENCE OR BARRICADE REQUIRES NO • — 0 -7 1 /2TD. OPENING [730] f7 Ja CLEARANCE. S I DE (.' ( i VERTICAL R I GHT T S I D E . 7. UNITS MAY BE INSTALLED ON COMBUSTIBLE FLOORS MADE n \ FROM WOOD OR CLASS A, B, OR C ROOF COVERING MATERIAL u /�/ 2 - [6 60]1 O a IF SET ON BASE RAIL. 1 -11 1/4 ` ' ' ,I L0' - 1/2 / I m 8. THE VERTICAL 01(9011 OF GRAVITY 15 l'- 7'14831 FOR 008 [591] (113.6] SUPPLY AIR y 012 AND 074 0' -9 7 /B' D' -1 15/18 0' -4 11/16' - - - -• 1 Z 3 UP FROM THE BOTTOM OF THE BASE RAIL. N _ _ 0 [251.41 / [48 [1207 c) (864101)05 SIZES /f,,,�IIII SEE BOTTOM POWER L7 I I 2 -1 [6351 O 1 3/B" DIA. 135] GU FIELD POWER )5 l HOLE J / E m 2 1 /7 [ POWER SUPPLY HOOK - our CORNER " 0000T)ELEC. ONLY) 1' -2- D " I13B1 -5 7/16- / 1 3/4 "01A [4d] CHARGING PORT WLE 2 " -4 .87 I 7 / B- I FRONT -e !3551 I 0' -3 I/8 CORNER -8 . O 1731 O 1/8' on. 1223 FIELD 00NTR0L 1161116 110,E 3 " -6 1/4 J. 1 . , - --I 3/16 1791 0 [O.OD] G7 3/4' -14 WY CONDENSATE C1AIN ' (1g711 _ [208] O 1/2 " -14 NPT 105 0015, 40140000,009, 40110000 a 3' -4 1/4 -01 ECONOMISER. 2 N 3/4 " -14 NPT GAS CCNN.J 48HJE/HJF009,009/ 110227 0 -7 5/16 . . 0'-4 - 4IMJ0,0/0,853 /T1)0l2,014, 40010,110012, H - ,a 7' -3 3/8 '• 11657 I [1011 W/ POWER EXHAUST y o 40.041.1101 \ °- [187] 8 122191 0 (100]/9- 2' -4 5 /18 - I 1' -0 5 /B -I A 6 Y DIA [51] POWER su7Br KNOCK -OUT - . -3 13/18 [719] [320] FILTER ACCESS PANEL _'I 8 FL [97] _ _ ■ i ,/ (DISPOSABLE FILTERS) FACTORY UE 0 1000 6000 ED 1 1 RETURN AIR - K AI A / CONTROL BOX/ '1' ® INDOOR FAN MOTOR 6 IDHORING CONDENSER COIL G COMPRESSOR/ BOXER ACCESS PANEL ZONTAL " BURNER ACCESS PANEL 2[61913/8 (' -1 7/8' 1 SUPPLY AIR ' 1 // I OPENING (s 1 . 0 '[. [3527 1 HORIZONTAL `I I - - - // 1635] \� \\ .. #— j 1 am ; 0 -3 59 F i% • / o'- 0 -7 /B- OUTSIDE AIR o 9 � 6 t4(DC) I I (� ® I�j� { [22.2] x ' D -5 3/4' 4 3• -()- I 3 -1 0' -Y D " -S 11/16 p :, 0 " -4 9/16" [914.4] FORK TRUCK SLOTS [9407 [178] [1447 1116] 4' -5 7/8 [1461 � d 8 0' -2 9/16'- 113691 \ 0 " -8 7/18 OUTSIDE 0' -2 1/4' [571 OF PANEL / BAROMETRIC RELIEF DISCHAGE w 1651 7YP ELECTRICAL (214] fTYP 8 PLACES) •� RIGHT S I DE I LEFT 5 I DE DISCONNECT LOCATION FRONT SUPPLY AIR RETURN AIR i E STD. CONDENSATE DRAIN I Packaged Rooftop Builder 1.19e Page 2 of 7 • • • Unit Report For Seven and Half Ton • Project: AutoZone 03/25/2009 Prepared By: David Ledbetter 05:06PM Unit Parameters Dimensions (ft. in.) & Weight (Ib.) *** Unit Model 48HJD008 - - -5 -HCA Unit Length 7' 3" Unit Size 008 (7 -1/2 Tons) Unit Width 4' 10" Volts- Phase -Hertz 208 -3 -60 Unit Height 3' 5" Heating Type Gas Base Unit Weight 870 Ib Duct Cfg• Vertical Supply / Vertical Return "* Weights and Dimensions are approximate. Weight does not include roof Heating Capacity: curbs, unit packaging, field installed accessories or factory Low Heat installed options. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Lines and Filters Gas Line Size 1/2 Condensate Drain Line Size 3/4 in. Return Air Filter Type Throwaway Return Air Filter Quantity 4 Return Air Filter Size 16x20x2 Unit Configuration Standard Electro- Mechanical Controls Standard Motor Cond & Evap AI /Cu Louvered Hailguards Non -Fused Disconnect Switch Warranty Information First Year - Parts Only (Standard) No optional warranties were selected. NOTE: Please see Warranty Catalog 500 -089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48HJD008 - - -5 -HCA Rooftop Unit 1 Base Unit Standard Electro- Mechanical Controls Standard Motor Cond & Evap AI /Cu Louvered Hailguards Non -Fused Disconnect Switch Accessories CRMANDPR002A03 25% Open Manual Outdoor Air Damper Package 1 Packaged Rooftop Builder 1.19e Page 1 of 7 SUBMITTAL I p r I R UNIT MODEL PROJECT: AUTO ZONE SLOPED ° E D ROOF CURB `B 48/50 TJ,TF 004 -007 EQUIPMENT: CARRIER (USED WITH AUTO ZONE DUCT PACKAGE #1002987) STORE it PART NUMBER LOCATION: 1002816 PITCH OF ROOF 1 /4" PER 12" FEATURES: ROOF CURB BODY IS FABRICATED OF HEAVY GAUGE GALVANIZED STEEL FULL PERIMETER WOOD NAILER PRE - PUNCHED ASSEMBLY HOLES AND HARDWARE 1 7/8" k— INCLUDED FOR DUCT SUPPORT INSTALLATION (DUCT SUPPORTS ARE REMOVABLE) ROOF CURB IS SHIPPED KNOCKED DOWN E ROOF CURB f4 1112 "x1/4" U NEOPRENE GASKET 67 1/8 8 0 t) • co WOODEN NAILER (C) 13 7/8 r ---1 1--- 3" ' O O CURB S/A CROSS SECTION ` 20 1/4 co `�\ -,%. (D) 36 15/16 j L `� o ��. 4 0) (B) 1311116 R/A 0 NOTE: (A) H 32 1/16H a ROOF CURB IS 14" HIGH AT THE LOWEST END OF THE CURB O 0 ROOF CURB IS LABELED WITH RTU # 1 LL RTU # HEIGHT OF CORNER a A B C D CAMBRIDGEPORT AIR SYSTEMS - p MEMPHIS, TN 38118 0) 15 3/8" 15 3/8" 14" 14" PHONE 1- 877 - 648 -2872 FAX 901 - 566 -0035 CO DATE: 2 -21 -02 REV: 02 0) 0 • 0 a SUBMITTAL UNIT MODEL PROJECT: AUTO ZONE DUCT WORK PACKAGE 48/50 TJ,TF 006 -007 EQUIPMENT: CARRIER (USED WITH PITCHED ROOF CURB #1002816) STORE #: PART NUMBER LOCATION: 1002987 FEATURES: 1. DUCT PACKAGE IS FABRICATED OF 22 GAUGE GALVANIZED STEEL. 2. DUCT PACKAGE IS SHIPPED KNOCKED AHU AHU DOWN. 3. DUCTS ARE INTERNALLY INSULATED. O 4. SUPPLY REGISTERS ARE DOUBLE 0 ROOF CURB DEFLECTION WITH ADJUSTABLE BLADES. r13.50] #1002816 S/A R/A 5. RETURN GRILLE IS 1/2" STANDARD O , ROOF EXPANDED METAL. t) J - / DECK J 1 I 1 42 7 00 1 C (2)14° x 14" 16.00 13.50- O CO (4)14' x 5" DOUBLE DEFLECTION — 20.00 — N DOUBLE DEFLECTION GRILLES GRILLE NOTES: 129.50 THE BOTTOM OF THE DUCTS ARE TO BE NO LOWER THAN THE BOTTOM OF THE ROOF JOIST. (6 DUCT PACKAGE DESIGNED TO HANDLE 1 I 1600 -2400 CFM. 0 (2000 CFM NOMINAL DESIGN SHOWN.) Cl_ 600 CFM 18' THROW 0 600 CFM . 03" STATIC PRESSURE DROP (ALL GRILLES). i (2 PLACES) FACE BARS ON GRILLES ARE ADJUSTABLE O TO CUSTOMIZE THE THROW AND PROFILE. U at I I 4— LL 200 CFM 10' THROW 0 200 CFM Q (4 PLACES) L I -31.50-1 RETURN GRILLE CAMBRIDGEPORT AIR SYSTEMS - o MEMPHIS, TN 38118 a) DATE: 2 - 21 - 02 REV: 02 PHONE 1- 877 - 648 -2872 FAX 901 - 566 -0035 N t5 - LL 0 0_ AA microMet1 o py§ iffuser P ac k ages ij 2018Senes 4 - t t' r t iN.44 ,49 4 -1/2 4 t ri 101.74SerieSA g 6 4T7 j ou r V eiV - srjANUARY 2002e MicroMeti Concentric Diffusers Contents: Flush mount diffuser packages... 3 1017 -100A, 200A, 300A Flush mount diffusers with fixed blades for 2 to 8 1/2 ton units 4 1017-411A, 511A, 611A Large flush mount diffusers with fixed blades for 10 to 15 ton units 5 1017 -800A, 990A Large flush mount diffusers with fixed blades for 20 to 25 ton units 6 Flush Mount Diffuser Performance Chart Drop diffuserpackages .. . 7 1018 -100A, 200A, 300A Drop diffusers with double deflection blades for 2 to 8 1/2 ton units 8 1018 -411A, 511A, 611A Large drop diffusers with double deflection blades for 10 to 15 ton units 9 1018 -800A, 990A Large Drop diffusers double deflection blades for 20 to 25 ton units 10 Drop Diffuser Performance Chart 11 Flex duct packages 2 R j Flush mount with fixed b lades... 1017 -100A, 200A, 300A MicroMetl typical specifications: flush mount diffuser with Furnish and install MicroMetl 1017 series concentric diffuser package. The package fixed blades for 2 to shall include concentric SA/RA diffuser with anodized aluminum, fixed in place, 81/2 ton units supply air louvers. Return core shall be mill finished aluminum and shall be removable by stud hangers and quarter turn fasteners. Diffuser box to include supply air turning vanes, molded fiber- glass return boot and flex duct connection -,-- - • collars. Package shall include hanging support and be shipped completely i assembled. Supply air turning vanes Duct, collars • A : -_ -- _ I C typ' �\ �\ Hanging Molded �_ clips fiberglass Brushed aluminum return air diffuser grille boot . 1017 Series Diffuser Specification (in, inches) MicroMetl Diffu Nominal . Package Part No. CFM A B C D E 1017 -100A 1600 441/2 201/2 16 24 13 1017 -200A 2000 44 1/2 20 1/2 18 24 13 1017 -300A 3000 44 1/2 26 1/2 20 30 14 • Refer to page 6 for performance data The MicroMetl Advantage: • Fixed supply air blades to provide a even air flow pattern. • Supply air turning vanes provide an even, 4 -way air distribution. • Molded fiberglass return air boot of lightweight construction for smooth air flow. • Factory installed hanging clips. • Duct collars for flex duct attachment. • Brushed aluminum diffuser grille with aluminum return air core. • Fully assembled, ready to set in place. • Designed to easily install in any type ceiling. 3 J 7 Large flush mount with round collars... 1017-411A, 511A, 611A MicroMetl typical Large flush mount (4) round duct collars specifications: for flexible duct diffusers with fixed blades attachment (4) Eyehooks Furnish and install for 10 to 15 ton units -- Ctyp. for hanging MicroMetl 1017 series concentric diffuser package. The package shall include concentric SA/RA diffuser with anodized aluminum, �� fixed in place, supply air tIP louvers. Return core shall Diffuser box is be mill finished aluminum. constructed of sheet B Diffuser box to be fabricated metal and insulated ...„--, © ! with insulated sheet metal with anti - microbial and include supply air insulation. D sq. turning baffles and flex duct connection collars. Insula ''..„ tion shall be anti - microbial The MicroMetl Advantage: Asq. type. Package shall include \ hanging support and be • Diffuser box and boot are constructed shipped edmpletely assembled. of galvanized sheet metal. • Diffuser box and boot are insulated with anti - microbial insulation, glued and pinned. 1017 -411A, 511A, 611A Series Diffuser , • Duct collars for flex duct attachment. Spe CIficatuon • • (in inches) MicroMetl Diffuser Nominal- •. Fully assembled, ready to set in place, Package Part No. CFM A B C D • Supply air turning vanes provide an 1017-411A 4,000 41 3A 23 17* 36 1 /2 even, 4 -way air distribution. 1017 -511A 5,000 47 3 /4 24 1/4 18 42 %/2 • Factory installed hanging hooks. 1017 -611A 6,000 53 3 /4 26 20 48 1 /2 1. Refer to page 6 for performance data. • Designed to easily install in any type 2. *Because of space limitations, the collars on the 1017 -411A are 17" dia., ceiling. instead of 18" dia. However, 18" dia. flexduct is still used and must be tightened down to attached to collars. r : Optional 0904 series flex duct. (2) packages are required. T (4) Eyehooks for hanging Brushed aluminum -<7 ;.� supply / return air diffuser grille 4 Large flush mount with fixed blades... Insulated . C sheet metal 1017 -800A 990A Dtyp.- ( typ• box (4) Eyehooks for Large flush mount diffuser hanging with fixed blades for o 20 to 25 ton units. e B E sq. = _ _ _ / � Diffuser box is constructed of \ \ ' Brushed aluminum sheet metal and insulated diffuser grille with anti - microbial insulation. . The MicroMeti Advantage: 1017 -800A 8, 990A Series, Diffuser Specification • Diffuser box and boot are (in inches) • constructed of galvanized MicroMeti Diffuser Nominal- sheet metal. Packa•e Part No. CFM A B C D E 1017 -800A • 8,000 59 % 29 1 /2 23 48 157 3/8 Diffuser lte box h a boot are insulated with anti-microbial 1017 -990A 10,000 65 % .3.6 28 52 63 5/8 insulation, glued and pinned. Refer to page 6 for performance data • Fixed supply air blades to provide a even air flow pattern. • Rectangular sheet metal duct collars for easy hard duct MicroMeti typical Return air attachment. specifications: collar • Fully assembled, ready to set Furnish and install MicroMeti 1017 ______0)... Supply air in place. series concentric diffuser package. ----_= - ,-.::::',-._ • The package shall include concen- r " -" ' �� �. -/collar • Supply turning vanes for even, t- - 4 -way air distribution. tric SA/RA diffuser with anodized . �� -.. \ , aluminum, fixed in place, supply air ', \ k :- \ : 1 louvers. Return core shall be mill �, ., =' -.1---..----' - • Factory installed hanging g g ;,% _ - -s , finished aluminum. Diffuser box to -\� � -- _-: \ eyehooks. be fabricated with insulated sheet ��" metal and include supply air turning �� ; --`' T -/ -/� • Brushed aluminum diffuser vanes and rectangular duct collars. j -! •' �`: grille with aluminum return air Insulation shall be anti - microbial % — core. type. Package shall include '-=';.--•:• '---•.• / �;, hanging support and be shipped '' ! % • Designed to easily install in completely assembled. ' - any type ceiling. Turning vanes for smooth, even air flow 5 0' - Flush Mount Performance.. MicroMetl Concentric Flush Diffusers 1017 Series 0902 Series 0902 Series 1017 Series 0904 Series Sup. Ret. Min. Max. Concentric . NC Up to Return Supply Duct Flex Free Free Part Number Description Unit Size Throw Throw Press Drop Noise CFM (ft) (ft) Diffuser Diffuser ( return, Adaptor Duct (4 ft.) (db) Area Area Press Drop Press Drop su I box Press Drop Press Drop Sq. Ft. Sq. Ft. PPy, ) 1,000 9 12 0.03 0.05 0.18 0.02 0.003 20 3.19 1.86 0902 -0012 Flush Diffuser Only 1,200 12 16 • 0.05 0.06 0.25 0.02 0.005 25 3.19 1.86 Up to 5 Tons 1,400 15 20 0.07 0.08 0.33 0.03 0.009 30 3.19 1.86 1,600 17 23 0.09 0.09 0.42 0.04 0.015 30 3.19 1.86 1017 -100A Flush Diffuser w/ Box and 16" Collars 1,800 20 26 0.11 0.11 0.53 0.05 0.024 35 3.19 1.86 2,000 22 29 0.13 0.12 0.64 0.06 0.038 40 3.19 1.86 1,000 9 12 0.03 0.05 0.14 0.01 0.001 20 3.19 1.86 0902 -0012 Flush Diffuser Only 1,200 12 16 0.05 0.06 0.20 0.01 0.002 25 3.19 1.86 1,400 15 20 0.07 0.08 0.26 0.02 0.003 30 3.19 1.86 Up to 6 Tons 1,600 17 23 0.09 0.09 0.33 0.03 0.005 30 3.19 1.86 1017 -200A Flush Diffuser w/ Box and 18" Collars 1,800 20 26 0.11 0.11 0.41 0.03 0.008 35 3.19 1.86 2,000 22 29 0.13 0.12 0.50 0.04 0.013 40 3.19 1.86 2,400 13 25 0.19 0.14 0.68 0.06 0.024 45 3.19 1.86 0902 -0013 Flush Diffuser Only 2,600 17 24 0.08 0.14 0.49 0.04 0.013 30 3.56 3.10 2,800 18 28 0.09 0.15 0.55 0.05 0.017 35 3.56 3.10 7 1/2 to 8 1/2 Ton Units 3,000 20 30 0.11 0.16 ' 0.62 0.06 0.022 35 3.56 3.10 1017 -300A Flush Diffuser w/ Box and 20" Collars 3,200 22 33 0.12 0.17 0.69 0.07 0.028 40 3.56 3.10 3,400 23 37 0.14 0.18 0.77 0.08 0.036 40 3.56 3.10 0902 -0005 Flush Diffuser Only 10 Ton Units 4,000 16 37 0.21 0.21 0.80 0.06 0.020 30 5.00 3.46 1017 -411A Flush Diffuser w/ Box and 18" Collars 0902 -0006 Flush Diffuser Only 12 1/2 Ton Units 5,000 16 32 0.16 0.17 0.70 0.06 0.058 40 6.00 5.30 1017 -511A Flush Diffuser w/ Box and 18" Collars 0902 -0007 Flush Diffuser Only 6,000 16 32 0.14 0.14 0.63 0.06 0.046 40 8.44 6.50 1017 -611A Flush Diffuser w/ Box and 20" Collars 15 to 18 Ton Units 7,200 22 44 0.20 0.21 0.92 0.08 0.112 45 8.44 6.50 0902 -0008 Flush Diffuser Only 7,200 47 80 0.09 0.15 0.41 N/A N/A 39 11.25 8.10 18 to 20 Ton Units 1017 -800A Flush Diff. w/ Box & 23" x 48" Collars 8,000 18 38 0.12 0.18 0.50 N/A N/A 45 11.25 8.10 0902 -0014 Flush Diffuser Only 25 Ton Units 10,000 21 45 0.10 0.23 0.52 N/A N/A 45 10.90 12.22 • 1017 -990A Flush Diff. w/ Box & 28" x 52" Collars Performance Notes: * All engineering data is based upon interpolated data and should be used for reference only. * Each NC value represents the noise criterion curve which will not be exceeded by the sound Actual readings may vary: pressure in any of the octave bands, 2nd through 7th. Each NC value is based on a room absorption of 10 db, re 10 -12 watts. * All pressure values are in inches of water. * The NC value is based upon an "A" weighting (Human Ear Listening Response). * Throw values are given for the terminal velocities of 150 fpm (min throw) and 50 fpm (max throw). • p diffuser packages ... 1018 -100A, 200A, 300A Drop diffuser with double Duct collars B deflection blades for 2 to A �.. 8 1/2 ton units Ctyp. 8" -- iiiii - s sia�� �1111�i ", �— ilIi i71111u11 [ , �IIl1l P - `� I i [111` V E �,�� D \ `�\` I Aluminum Double Hanging clips deflection Finish diffuser grille MicroMetl typical specifications: Furnish and install MicroMetl 1018 series concentric diffuser package. The package shall include side supply, double deflection diffusers with center _ pivoted air foil louvers. Return core shall be mill finished aluminum and shall be removable. Diffuser box to include supply air turning vanes, molded fiberglass return boot and flex duct connection collars. Package shall include hanging support and be shipped completely assembled. 1018 -100A, 200A, 300A Drop Diffuser The MicroMetl Advantage: Specification .(in inches) MicroMeti Diffuser Nominal A B C D E • Adjustable double deflection supply air Package Part No. CFM louvers. 1018 -100A 1,600 461/4 21 3/8 16 47'/, 23'/. • Molded fiberglass return air boot of 1018 -200A 2,000 46 1/4 21 3/8 18 47 %, 23'/. lightweight construction for smooth air 1018 -300A 3,000 46 1/4 27 3/8 20 47'A 29'/, flow. Refer to page 10 for performance data • Duct collars for flex duct attachment. • • Fully assembled, ready to set in place. Supply air turning vanes • Supply air turning vanes provide an - -- __ __ __ even, 4 -way air distribution. Molded fiberglass -- __,...r.- :-. — - - - - - -- return air boot � _ T • Factory installed hanging clips. ` ----- = • Designed to easily install in any type / A G ceiling. Great where long air throws — � I and /or volume is required. / 11 111,, , rn . -- - -- ,- -, 7 y Large drop diffuser with round collars... C typ (4) round duct collars for flex 1018-411A, 511A, 611A duct attachment . Large drop diffuser with s double deflection blades 4111- o for 10 to 15 ton units 0 D sq. B ■ Iilpli l111111h. h ► j' Im I II�I��I� MicroMetl typical specifications: VIII U�� Furnish and install MicroMetl 1018 110 I (III A sq series concentric diffuser package. The Diffuser box is constructed of package shall include side supply, Adjustable Double sheet metal and insulated adjustable double deflection diffusers deflection diffuser with anti - microbial insulation. with center pivoted air foil louvers. grille Return core shall be mill finished aluminum. Diffuser box to be fabricated 1018 -411A, 511A, 611A Diffuser with insulated sheet metal and to include supply air turning vanes and flex Specifications (in inches) duct connection collars. Insulation shall Mi Metl Diffuser Nominal- A B C D be anti - microbial type. Package shall Package Part No. CFM include hanging eyehooks and be 1018 -411A 4,000 41 3 /4 20 *17 1 39 3/8 shipped completely assembled. 1018-511A 5,000 47 3 /4 •20 18 45 3/8 1018 -611A 6,000 53 3 A 26 20 51 3/8 1. Refer to page 10 for performance data. The MicroMetl Advantage: 2. *Because of space limitations, the collars on the 1018 -411A are 17" dia., instead of 18" dia. However, 18" dia. flexduct is still used and must be tightened down to attached to collars. • Diffuser box and boot are constructed of galvanized sheet metal. Optional 0904 series • Diffuser box and boot are insulated flex duct. (2) packages with anti - microbial insulation, glued are required. � . and pinned. r { • Adjustable double deflection supply air louvers to provide an even air flow pattern. f • Round duct collars for flex duct attachment. 0 • Fully assembled, ready to set in place. (4) eyehooks for \ hanging • Supply air turning vanes for an even, 4- Insulated c- ' » way air distribution. sheet metal box--„,, I i ' • Factory installed eyehooks for hanging. _ Dili , , l s lo , , , i MI • Designed to easily install in any type 110_...-'- , 1.: ceiling. Great where long air throws - -/ and /or volume is required. Aluminum finish 8 • Optional insulated flex duct packages... 0904 -0003, 0004, 0005 Insulated Flex Duct The MicroMetl 0904 series insulated flexible duct packages consists of (2) UL listed flexible ducts that include a vapor barrier and 1 1/2" fiberglass insulation. • 0904 Series. Flex Duct Specifications Diffuser Package Micr Diffuser Qty Description Package Part No. 1017/1018 -100A 0904 -0003 1 (2) 16" openings X 48" long sections 1017/1018 -200A 0904 -0004 1 (2) 18" openings X 48" long sections 1017/1018 -300A 0904 -0005 1 (2) 20" openings X 48" long sections 1017/1018 -411A 0904 -0004 2 (4) 18" openings X 48" long sections 1017/1018 -511A 0904 -0004 2 (4) 18" openings X 48" long sections 1017/1018 -611A 0904 -0005 2 (4) 20" openings X 48" long sections NOTE: 1017/1018 -411, 511A, and -611A Diffuser packages with (4) round collars will need (2) flexduct packages. 11 Large drop diffuser packages... MicroMetl typical 1018-800A, 990A specifications: Large drop diffuser 4 E ehooks for Furnish and install MicroMetl 1018 g p �� y series concentric diffuser pack - with double deflection Ctyp., hanging age. The package shall include side supply, double deflection blades for 20 to 25 ton p - Dtyp. diffusers with center pivoted air foil units louvers. Return core shall be mill Q finished aluminum. Diffuser box �j fabricated with insulated sheet .1A401. metal and to include supply air turning baffles and rectangular duct collars. Insulation shall be Adjustable double 9 g anti - microbial type. Package shall deflection diffuser . . , _ include hanging support and be grille shipped completely assembled. ',VIII C OI (7 -411111% II Diffuser box is constructed of I sq sheet metal and insulated /------- with anti - microbial insulation, p � , 1018 -800A, 990A Diffuser Specifications (in inches) • MicroMetl Diffuser �1Dlil �,_ 111411141 Package Part No. CFM A B C D E I II <- .— e� .I I II iilfl �Ij� li� l � � l � l 1018 -800A 8,000 59 % 26 23 48 57 3/8 ( 1018 -990A 10,000 65 % 32 28 52 63 5/8 Refer to page 10 for performance data Aluminum The MicroMetl Advantage: finish • Diffuser box and boot are constructed of galvanized Flanges for hard duct sheet metal. attachment Supply air collar iiiwiTo • Diffuser box and boot are insulated with anti - microbial ' insulation, glued and pinned. Return air �� collar ` ©- 7,,,,‘,11447, z • Adjustable double deflection supply air louvers to © provide a even air flow. • Rectangular sheet metal duct collars for easy hard duct - - attachment. • • Fully assembled, ready to set in place. �j111I • Supply air turning vanes provide an even, 4 -way air I 1 �� distribution. �• Factory installed hanging corner supports. • Designed to easily install in any type ceiling. Great ? Turning vanes where long air throws and /or volume is required. for smooth, even air flow 9 Drop Diffuser Performance . MicroMet! Concentric Drop Diffusers 1017 Series 0902 Series 0902 Series Concentric 1017 Series 0904 Series Sup. Ret. Min. Max. NC Up to Return Supply Press Drop Duct Flex Free Free Part Number Description Unit Size CFM Throw Throw Noise Diffuser Diffuser (return, Adaptor Duct (4 ft.) Area Area (ft.) (ft) Press Drop Press Drop supply, Press Drop Press Drop (db) Sq. Ft. Sq. Ft. box) 1,000 9 23 0.01 0.01 0.11 0.02 0.003 12 2.12 4.31 1818 -200A Drop Diffuser Only 1,200 10 24 0.01 0.01 0.16 0.02 0.005 15 2.12 4.31 Up to 5 Ton Units 1,400 12 26 0.02 0.01 0.22 0.03 0.009 19 2.12 4.31 1,600 13 28 0.02 0.02 0.28 0.04 0.015 21 2.12 4.31 1018 -100A Drop Diffuser w/ Box and 16" Collars 1,800 15 30 0.03 0.02 0.36 0.05 0.024 26 2.12 4.31 2,000 17 32 0.04 0.03 0.44 0.06 0.038 30 2.12 4.31 1,000 9 23 0.01 0.01 0.07 0.01 0.001 12 2.12 4.31 1818 -200A Drop Diffuser Only 1,200 10 24 0.01 0.01 0.11 0.01 0.002 15 2.12 4.31 1,400 12 26 0.02 0.01 0.15 0.02 0.003 19 2.12 4.31 Up to 6 Ton Units 1,600 13 , 28 0.02 0.02 0.19 0.03 0.005 21 2.12 4.31 1018 -200A Drop Diffuser w/ Box and 18" Collars 1,800 15 30 0.03 0.02 0.24 0.03 0.008 26 2.12 4.31 2,000 17 32 0.04 0.03 0.30 0.04 0.013 30 2.12 4.31 2,400 19 34 0.05 0.04 0.43 0.06 0.024 32 2.12 4.31 1818-300A Drop Diffuser Only 2,600 22 39 0.03 0.04 0.34 0.04 0.013 32 2.32 5.79 2,800 23 40 0.04 0.04 0.39 0.05 0.017 38 2.32 5.79 7 1/2 to 8 1/2 Ton Units 3,000 25 42 0.04 0.06 0.45 0.06 0.022 40 2.32 5.79 1018 -300A Drop Diffuser w/ Box and 20" Collars 3,200 26 43 0.05 0.08 0.53 0.07 0.028 41 2.32 5.79 3,400 27 45 0.06 0.10 0.61 0.08 0.036 42 2.32 5.79 1818 -400A Drop Diffuser Only 10 Ton Units 4,000 29 58 0.06 0.21 0.51 0.04 0.024 30 4.88 6.50 1018 -411A Drop Diffuser w/ Box and 18" Collars 1818-500A Drop Diffuser Only 12 1/2 Ton Units 5,000 33 62 0.05 0.18 0.60 0.06 0.058 30 5.67 9.08 1018 -511 A Drop Diffuser w/ Box and 18" Collars • 1818 -600A Drop Diffuser Only 6,000 40 70 0.04 0.17 0.56 0.06 0.046 37 6.67 12.09 15 to 18 Ton Units 1018 -611A Drop Diffuser w/ Box and 20" Collars 7,200 46 79 0.06 0.27 0.84 0.08 0.112 47 6.67 12.09 1818 -800A Drop Diffuser Only 7,200 47 80 0.04 0.25 0.46 N/A N/A 39 7.47 13.76 18 to 20 Ton Units 1018 -800A Drop Diff. w/ Box & 23" x 48" Collars 8,000 48 82 0.05 0.25 0.51 N/A N/A 39 7.47 13.76 • 1818 -990A Drop Diffuser Only 25 Ton Units 10,000 52 90 0.05 0.30 0.54 N/A N/A 41 8.27 17.42 1018 -990A Drop Diff. w/ Box & 28" x 52" Collars Performance Notes: * All engineering data is based upon interpolated data and should be used for reference only. * Each NC value represents the noise criterion curve which will not be exceeded by the sound Actual readings may vary. pressure in any of the octave bands, 2nd through 7th. Each NC value is based on a room absorption of 10 db, re 10 -12 watts. * All pressure values are in inches of water. * Throw values are given for the terminal velocities of 150 fpm (min throw) and 50 fpm (max * The NC value is based upon an "A" weighting (Human Ear Listening Response). throw). AA • 0 MicroMetl Indianapolis MicroMetl West 3035 North ShadelandAvenue 202 South 18th Street Suite 300 Sparks, NV 89431 Indianapolis, IN 46226 1- 800 - 884 -4662 (Toll -free) 1- 800 - 662 -4822 (Toll -free) 1- 775 - 356 -9184 (Fax) 1- 317 - 543 -5986 (Fax) Form No. 1231-1OP Copyright 2002 In the interest of continuous product improvement, MicroMetl reserves the right to discontinue, or change at any time, designs and prices without notice and without incurring obligations. This document is the property of MicroMetl and is delivered upon the express condition that the contents of this printed piece will not be reproduced or disclosed in any form without MicroMetl's written consent. 2002 • A U' D / B L E / V / S /° B L E N O T I F I C A T I O N ' ' ` . . S PECT FAIe rt ' , , . , . , . . , . . , , . . , . „ ... Selectable Output Strobe * SYSTEM \ , and Horn /Strobes .SENSOR 1 Models Available ; X47 — ; '° E ,x , !' Strobes �' -,' '. 3 P1224MC H orn / ,. pr Red White �. SIRE .fi S1224MC S1224MCW , ," F i RE lit t, -',,-. S1224MCP S1224MCPW S1224MCK z S1224MCSP - J w5 Horn /Strobes ; 9 � - Red White r P1224MC P1224MCW x P1224MCP P1224MCPW . i � , 1 ! A "i ., <! P1224MCK i ii l T fif +; p .e - P1224MCSP _ ,ii � hj. ` ,,5 1, *-1. 'v,J -• .1 Horns " , ... , 2‘ 4 ' 1 -- --:----- : 4- ' . ' k . , s Red White + � H12/24 H „ :iZ” M40bey � : �. H12/24K t .,'- , ,-i r � w ? Product Overview Operates on either 12V or 24V SpectrAlert Selectable Output Horns, Strobes, and Horn /Strobes offer enhanced fea- Widest range of candela options: tures that include the widest range of candela options available and the capability to 12V: 15 and 15/75 candela recognize and self- adjust for either 12 or 24 volt operation. With an overall feature 24V: 15, 15/75, 30, 75, 110 candela set that combines performance, installation ease, flexibility, and a consistent, aesthetically pleasing appearance, the SpectrAlert Selectable Output devices Easy candela selection provide both the innovation and efficiency synonymous with the SpectrAlert name. Lower current draw Performance. SpectrAlert selectable output wall -mount horns, strobes, and horn/strobes Easy DIP switch selection for horn offer key performance features long associated with the SpectrAlert name. The select - options able candela strobes and horn /strobes offer average current draws that are not only lower than conventional fixed- candela SpectrAlert products, but also lower than similar Easy mounting with QuickClickTM selectable candela products. By consuming less current, the ability to connect even more Synchronizable with MDL devices per loop is possible, resulting in a lower installed cost. Sync.CircuitTM module Installation. SpectrAlert selectable output horns, strobes, and horn/strobes offer the Meets UL1971, NFPA72, and ADA same installation - friendly features synonymous with the SpectrAlert name, such as the signaling requirements option of 2- and 4 -wire operation; the ability to use standard size backboxes with no encroachment into the box; and universal mounting incorporating the labor- saving All strobe and horn /strobe models incorporate a new patented voltage booster design that has QuickClick' feature. Such labor - savings features make wire connections simple and fast, a more consistent flash bulb voltage over the further reducing installed cost. range of candela selections. The benefit to the Flexibility. SpectrAlert selectable output strobes and horn/strobes offer the broadest customer is a high quality strobe device. range of candela options. In addition, the selectable output strobes and horn /strobes can operate on either 12V or 24V, with no setting required; the device recognizes and Pr !� self- adjusts to the correct current automatically. Temporal 3 or Continuous tone options /O) ID continue to be available, in either an Electromechanical or 3kHz pattern. LISTED ll 55512 Aesthetics. SpectrAlert selectable output horns, strobes, and horn/strobes incorporate 71251209:222 54011 71351209:223 the same stylish, low profile design of the conventional SpectrAlert products, for a con- ® MEA sistent and aesthetically pleasing appearance across the entire product line. approved nrrmveo 122 - 02E 3014150 120 -02 E • Engineering Specifications General fire protective service. Horn/strobe shall be wired as a primary SpectrAlert horns, strobes and horn/strobes shall be capable of signaling notification appliance and comply with the Americans mounting to a standard 4" x 4" x 1 back box or a single gang with Disabilities Act requirements for visible signaling appliances, 2" x 4" x 1' /8" back box using the universal mounting plate flashing at 1Hz over the strobe's entire operating voltage range. included with each SpectrAlert product. Also, SpectrAlert prod- The strobe light shall consist of a xenon flash tube and associated ucts, when used in conjunction with the accessory Sync•Circuit lens /reflector system. The horn shall have two tone options, tvvo Module, shall he powered from a non -coded power supply audibility options (at 24 volts) and the option to switch between and shall operate on 12 or 24 volts. 12 volt rated devices shall a temporal 3 pattern and a non - temporal continuous pattern. have an operating voltage range of 9 -17.5 volts. 24 -volt rated Strobes shall he powered independently of the sounder with the devices shall have an operating voltage range or 17-33 volts. removal of factory installed jumper wires. The horn on horn/ SpectrAlert products shall have an operating temperature of strobe models shall operate on a coded or non -coded power sup - 32° to 120 °F and operate from a regulated DC or full wave ply (the strobe must be powered continuously). rectified, unfiltered power supply. Synchronization Module Strobe Module shall be a System Sensor Sync•Circuit listed Strobe shall be a System Sensor SpectrAlert Model to UL 464 and shall be approved for fire protective service. The listed to UL 1971 and be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and horns strobe shall be wired as a primary signaling notification appliance at temporal 3. Also, the module shall silence the horns on horn/ and comply with the Americans with Disabilities Act require- strobe models, while operating the strobes, over a single pair of ments for visible signaling appliances, flashing at 1Hz over the wires. The module shall he capable of mounting to a 4h'/l6" x strobe's entire operating voltage range. The strobe light shall con- 4 11 /16" x 2 back box and shall control two Style Y (class B) or sist of a xenon flash tube and associated lens /reflector system. one Style Z (class A) circuit. Module shall he capable of multiple zone synchronization by daisy chaining multiple modules together Horn /Strobe Combination and re- synchronizing each other along the chain. The module Horn/Strobe shall be a System Sensor SpectrAlert Model shall not operate on a coded power supply. listed to UL 197:1 and UL 464 and shall be approved for Specifications Walk Test Weight, horn only Voltages • SpectrAlert horn /strobe and horn only 7.2 oz. 12 or 24VDC and FWR unfiltered work on "walk tests" with time dura- Weight, strobe and horn /strobe Operating voltage range tions of 4 seconds or greater 8.8 oz. 12V: 8- 17.5V; 24V: 16 -33V Input Terminals 12 to 18 AWG Mounting Operating voltage range (with 4" x 4" x 1 or 2" x 4" x 1 Sync•Circuit module, MDL) Dimensions standard boxes 12V: 9- 17.5V; 24V: 17 -33V Strobe and horn /strobe with universal plate Operating Temperature (Indoor) U.S. Patent Numbers 5" x 5 x 215/16" 32 °F to 120 °F (0 °C to 49 °C) 5,593,569 Maximum humidity (indoor) 5,914,665 Strobe and horn /strobe with small y ( 6,049,446 footprint plate 95% as tested per UL464 3 x 5 x 25/16" Outdoor (K Series) Operating Temperature Horn with universal mounting plate —40 °F to 151 °F 5" x 5 x 1 ( -40 °C to 66 °C) • Horn without mounting plate Outdoor rating 2 x 5 x 15/16" NEMA 3R (per UL 50) Notes: 1. Full Wave Rectified (FWR) voltage is a non - regulated, time - varying power source that is used on some power supply and panel outputs. 2. The MDL causes a one -volt voltage drop in the notification appliance circuit. Table 1 -A: SpectrAlert Strobe UL Max. Current Draw Explanation of Published Voltage, Current, and SPL FWR Operating DC Operating Specifications Current - Strobe Current- Strobe Candela (mA RMS) (mA RMS) In May 2004 Underwriters Laboratories changed standard Setting 8 -17.5V 16-33V 8 -17.5V 16-33V UL 1971 to require that operating current measuremments 15 112 64 127 59 are made using RMS (root mean square) instead of peak 15/75 135 74 127 69 or average values. RMS measurements more accurately 30 93 90 predict the power consumption of a device since they take 75 158 160 110 208 209 into account the entire current draw profile including surge, repetitive surge, and peak values. The published RMS cur- rent is the maximum operating current of that device within its operating voltage range. This current maximum may or Table 1 -B: Horn UL Max. Current Draw Measurements (mA RMS) may not occur at the endpoints of the voltage range. DC FWR Selectable Horn Tones 817.5V 1633V 8.17.5V 1633V Similarly, UL tests the audibility of devices in accordance Temporal Low Electromechanical 15 23 13 23 with UL 464 by measuring them across the operating volt - Volume 3000 Hz Interrupted 15 33 13 23 age range to determine the minimum sound pressure level High Electromechanical 36 53 20 44 produced at any particular setting. Volume 3000 Hz Interrupted 43 57 21 40 Non- Low Electromechanical 16 37 19 29 During May 2004, UL also changed the way they list the Temporal Volume 3000 Hz Interrupted 16 32 18 33 voltage range of a device. All 12V products will be listed High Electromechanical 38 49 46 49 between 8 - 17.5V and all 24V products will be listed Volume 3000 Hz Interrupted 44 56 42 58 between 16 - 33V. Those devices are considered "regulat- ed". Any product that does not operate within these ranges will be listed as a "special application" with its operating Table 1 -C: 12VDC Horn /Strobe UL Max. Current Draw voltage specified on the device. Measurements (mA RMS) Temporal Notes Low Volume High Volume 1. Current draw for strobe -only products is shown in Table 1 -A. Candela Electromechanical 3000 Hz Electromechanical 3000 Hz 2. Current draw for horn -only products is shown in Table 1 -B. Setting 15 111 111 112 112 3. 12VDC 2 -wire horn /strobe current is shown in Table 1 -C. 15/75 127 127 126 129 4. 24VDC 2 -wire horn /strobe current draw is shown in Table 1 -D. Non - Temporal 15 113 112 114 115 5. Current draw for other horn /strobe power supplies can be 15/75 128 128 130 134 calculated by adding the strobe current in Table 1 -A to the horn current in Table 1 -B from the chosen settings. Table 1 -D: 24VDC Horn /Strobe UL Max. Current Draw SpectrAlert Strobe Candela Selections Measurements (mA RMS) For strobe candela selection, adjust slide switch located on the Temporal rear of the product while watching the viewing window on the Low Volume High Volume side of the reflector. Candela Electromechanical 3000 Hz Electromechanical 3000 Hz Permissible Candela Settings Setting 15 71 70 73 75 Candela Setting Operating Voltage 15/75 86 85 87 88 12V 24V 30 99 98 100 100 I ii= ' 15 OK OK OK 75 166 166 167 170 Vd 15/75 30 OK OK 110 209 209 210 213 Non - Temporal 75 OK 110 OK 15 74 74 79 82 Viewing Window A0133 - 00 15/75 86 88 93 96 30 101 101 107 110 75 167 167 173 176 110 213 213 218 222 Jo a SpectrAlert Horn Sound Measurements (dBA) Typical weatherproof mounting with universal plate . WBB Plate Selectable Horn Tones 8 1633v #8 -36 x 1/2" Flat Head ' ; — Screw (4 total) Temporal Low Electromechanical 67 75 _4 ;� � �;. l �_ 1 � � Volume 3000 Hz Interrupted 68 75 a� ' mow; .,, ( � F -, High Electromechanical 71 80 ( Volume \a • 3000 Hz Interrupted 72 81 Non- Low Electromechanical 71 79 Temporal Volume � • , 3000 Hz Interrupted 72 79 Baia:: High Electromechanical 76 84 Gasket 1 �` � �� Volume 3000 Hz Interrupted 77 86 Conduit P Entrance Slot Paper Liner Locking Rib Operation on P1224MC Gasket Plate DIP Switch 0 P Gasket A0135 -02 Factory IDIP Switch OFF ON Default Low 1 MI High 0 0 <, 0 Temporal IMII I Non- Temporal o -0 Electromech. I ®1 1 3000Hz 0 1 0 0 Base (rear) A0110 -00 SpectrAlert Ordering Information Model Description Model Description P1224MC Selectable Output Horn /Strobe, 12/24 volt, red H12/24 Horn, 12/24 volt, red P1224MCW Selectable Output Horn /Strobe, 12/24 volt, white H12/24W Horn, 12/24 volt, white • P1224MCP Selectable Output Horn /Strobe, 12/24 volt, red, H12/24K Horn, 12/24 volt, red, outdoor plain housing Accessories P1224MCPW Selectable Output Horn /Strobe, 12/24 volt, MDL Sync•Circuit Module, red white, plain housing P1224MCK Selectable Output Horn /Strobe, 12/24 volt, red, MDLW Sync•Circuit Module, white outdoor MDLWA Sync•Circuit Module, white, Canadian model P1224MCSP Selectable Output Horn /Strobe, 12/24 volt, red, S -MP Small Footprint Mounting Plate, red, for single - "FUEGO" housing gang back box S1224MC Selectable Output Strobe, 12/24 volt, red S -MPW Small Footprint Mounting Plate, white, for single - S1224MCW Selectable Output Strobe, 12/24 volt, white gang back box 51224MCP Selectable Output Strobe, 12/24 volt, red, plain BBS Surface Mount Back Box Skirt, red housing BBSW Surface Mount Back Box Skirt, white S1224MCPW Selectable Output Strobe, 12/24 volt, white, D -MP Universal Mounting Plate (replacement), red plain housing D -MPW Universal Mounting Plate (replacement), white S1224MCK Selectable Output Strobe, 12/24 volt, red, outdoor WBB Weatherproof Back Box S1224MCSP Selectable Output Strobe, 12/24 volt, red, " FUEGO" housing Notes All of these SpectrAlert products are designed for wall mount only. All outdoor models must use weatherproof back box model WBB. Installation of less than 75 candela strobes may be permissible under the equivalent facilitation clause of the ADAAG (Sec. 2.2). However, it is the responsibility of the person or entity designing the fire alarm system to determine the acceptability of less than 75 candela strobes. All 15/75 candela strobes or horn/ strobes are recommended for 20' x rooms or less. System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor in China System Sensor — Far East System Sensor — India 3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.8832.0119 Ph: 85.22.191.9003 Ph: 91.124.237.1770 x.2700 St. Charles, IL 60174 Fx: 905.812.0771 Fx: 86.29.8832.5119 Fx: 85.22.736.6580 Fx: 91.124.237.3118 Ph: 800 /SENSOR2 System Sensor Europe System Sensor In Singapore System Sensor — Australia System Sensor — Russia • Fx: 630/377-6495 Ph: 44.1403.276500 Ph: 65.6273.2230 Ph: 613.54.281.142 Ph: 70.95.937.7982 www.systemsensor.com Fx: 44.1403.276501 Fx: 65.6273.2610 Fx: 613.54.281.172 Fx: 70.95.937.7983 © 2005 System Sensor, The company reserves the right to change product specifications without notice. A05- 0325 - 006.9/05• #1526 SURVEYOR DATA CONCENTRATOR MODEL Energy Management System INSTALLATION INSTRUCTIONS. DC400 -E2 CAUTION DISCONNECT POWER TO ALL APPROPRIATE DEVICES BEFORE INSTALL- ING THE DATA CONCENTRATOR. The Data Concentrator must be mounted Q inside the mechanical enclosure of the HVAC system or indoors. This product is not intended to withstand outdoor environments. This product is not intended for plenum use. WARNING TRANSFORMER CONNECTION The Data Concentrator should be connected to the supplied wall transformer as shown in figure 2. Transformer Specifications t ti-.J -® na ®® 1. CD i 1 1111 .1; {l— — Iai1l' ° I 2 5m ......... - -+ I 5mm - - -- I '! j'' SURVEYOR AC ADAPTOR � CLASS 2 TRANSFORMER MODEL SCP41- 90500A Figure I INPUT: 120V AC 60Hz W W OUTPUT: 9 O AC 500mA �51 ��I Figure 2 INTERNET CONNECTION The Data Concentrator should be connected to a full -time internet connection using a CAT -5 cable. O ® G *1.=-=3\\ ‹. SERIAL PORT CONNECTION The Data Concentrator may be connected to a RS -232 serial port on a computer or laptop. This enables local control with the included Local Control Software. el 0 00 0 0 P II o.. t...� s 1 .:. $ 0 ti u © y e° e°�OCOO®� 1 o o `'"HEEHEE o 0, P LEI 00 o ICJ m e l 10 I 1 ° Inp t Venstar Inc. - Made in China - 06/06 - Patents Pending ° I Q ' , P/N 88 -454 Rev. 1 A s S ENSOR PAC MODEL SURV EYR ' ' � Energy `Monagement`System INSTALLATION INSTRUCTIONS SP400 ECP SENSOR CONNECTIONS The Equipment Control Pac (ECP) is able to read a variety of sensors as shown below. 'YELLOW BLACK' SENSORS Equipment Control Pac 'ORANGE REMOTE AIRFLOW GREEN' SENSORS Mounted Inside the HVAC Unit or indoors I . �� t or indoors _ TTY l p. AIRFLOW SE NS R SUCTION DISCHG • • DISCHG S I T T • I (GREEN) 1.-- 1 1 ' D RETURN SENSOR — SUPPLY RETURN (RED) L..I ( 7 SUPPLY SENSOR LJ 1 !1 L i L J (BLUE) i I • • I SUCTION SENSOR l fl n h JIlinm k I 1.111:1 (ORANGE) BLUE RED LOCATIONS OF SENSORS: (DISCHARGE & SUCTION) Mount the Discharge Sensor and Suction Sensor as shown in the diagram below. Each sensor may be attached to the pipe using a plastic cable tie. 0 Mount the Discharge ' DISCHG SENSOR Sensor close to the y �I .n.nuunnnn ^ „unngl f = : l nunuu.umur�. .....�np inlet of the Condenser. TXV 1 1 1 1 1 1 1 II III WiifiifillialW IliiiliiiiIIIUllhiIIiIiIill lilliiIIIII I11I 1 IIIIIIIIIIIIIIIIIiiiiiiIIIIU a Ilummuuuuuumui auuuuullm uuuuill r ml mmmmuul mlll j IIIIIIRIIRIIIDIIIIRIIIIIIIII 111111111111111111111111111111111 , ® Mount the Suction Sensor a —GCE, EVAPORATOR CONDENSER SUCTION SENSOR as close to the outlet of the TTI � Evaporator as possible. 'SUS VAPOR N) 1�� W l + EIO '— LINE SERVICE ACCESS / / �C , OMPRESSOR PORT �\) LIQUID LINE ti j SER ACCESS t PORT LOCATIONS OF SENSORS: (AIRFLOW, SUPPLY, & RETURN Mount the Airflow Sensor, Supply Sensor, and Return Sensor as shown in the diagram below. c oil Eco co oling " Filters _.`` Cond u Ply Air Fan r IEe air ft er� j` AI Cood ' '' III_,'`".. A ® R SENSOR the Return Sensor in Fan _': � .., ,": ill the Return Air Duct as shown. � - ,� r r S UPPLY SENSOR i % It — 0 Mount the Supply Sensor in -. ri ■ ` �� the Supply Air Duct as shown. A Ir `, '� R etur n � AIRFLOW SENSOR ,` h M ount the Airflow Sensor in Or' e„,e` 'y A'r the Supply Air Duct as shown. S u PP Ai ors co roP r e ss Venstar Inc. - Made in China - 07/04 - Patents Pending P/N 88 -422 Rev. 3 COMMUNICATING TH ERM O STAT MODEL En SURVEYO ea•gyManagementSysfem INSTALLATION._ INSTRUCTIONS ,, U414 , BASIC OPERATION Select a Mode 2 , The HEAT setting Indicates the Mo ° temperature the room has to I D • I _ r % % IL 'L.r rJr'm reach before the furnace will I 0 1 HEAT„ Press PROGRAM MODE will actl- N;r, Occupied 1 IJ !� vote the stored timer o 111 ° coou MODE turn on to heat the room. _� Aeration. This Is indicated on the display HEAr a • as Occupied 1,2,or 3, or t — I j �-+ rr� `i unoccupied. I I t-I [ •r r`I p , ; � p Press The COOL setting indicates the m„ l� MODE temperature the room has to ° 600u i 11111111 114,0 reach before the alr conditioner IC • >_2r pn, will turn on to cool the room. Press OFF indicates both heating Mo o MODE and air conditioning I J � systems are turned off. OFF AUTO will automatically select Mo o coou heat or cool based on room AUTO iii temperature demand. HEAT G i 6� Press MODE SENSOR DISPLAY Press the "Outside" button to OUTSIDE access these sensor's readings. I 19 52 c Awe This screen indicates ttempleratureply air the temperature at I I --o 11 Outside Air Press the outdoor temp. a Press Sensor. A - DOWN DOWN Abe 8 9.7 7 Awe This screen indicates Displays discharge air 1.III* % the amount of outside ' 1 � temperature. humidity if the sensor Outside has been installed. Press ' -' Hu Press j DOWN DOWN Q Aber 12 ;I Aber Displays mixed air �1 I temperature. Displays indoor humidity. ' ' T (Return air temperature (if installed) if no economizer r is installed Press ' HLI Press I P I I DOWN 7 77 � C DOWN 2 1 I � t in feet air er minute. velocity 17 50 I, n et pnut Remote room sensor. This value is controlled Velocity displayed in Nk to if the sensor is 10 feet per minute present. increments. Press Press DOWN DOWN 1 a0 , ASP 2`�5 In I� Displays internal Displays the suction secondary on ac. dary voltago to the temperature. Equipment Control P tilk Press Press DOWN OUTSIDE Press the OUTSIDE button to return to the normal display. Venstar Inc. - Made in China - 06/06 - Patents Pending P/N 88 -454 Rev. 2 SURVEYOR' COMMUNICATING THERMOSTAT MODEL Energy Management System INSTALLATION INSTRUCTIONS CT414 CAUTION DISCONNECT POWER TO ALL APPROPRIATE DEVICES BEFORE INSTALL - A ING THE COMMUNICATING THERMOSTAT The Communicating Q This product is not intended to withstand outdoor environments. This product is not intended for plenum use. WARNING WIRING DIAGRAM The Communicating Thermostat should be connected to the Equipment Control Pac with 18 gage, 4 conductor wire. — flnflrl,, RTf O nn,..,,rt�— co,noaCATIOMS SUS POMP NO OUTPUTS ECO1 NI THERMOSTAT BE ,. Al ,. 0UT2 burl 01 02 I Id "' 2 3 � n n I r � l® R JJ 000 000000 00 ---[]— o 0 0 0 0— 0 0 0 0 0 00 0 0 R °I •6I` Rnu% R C LKI CICt B Yl. ' r ° o , °°o Terminal 1 IT-- 0 ° ' o Terminal 2 o ° 3 ° Terminal 3 CD ° ° Terminal 4 REMOTE SENSOR DIAGRAM The Communicating Thermostat may read the temperature from a remote temperature sensor connected to the Equipment Control Pac with 3 conductor, 18 gage, unshielded cable. This remote sensor wire must be run separately from all other wiring. Use a separate 3 conductor 18 gauge unshielded cable RS -GND from the sensor to the ECP. —Black 1 n . White Connect the sensor RS +v to the ECP Remote Red terminal using the 0 , supplied connector. SENSORS RDNOTE RIRFLOW Do not use any shielded SUCTION DISCHG cable or run remote sensor • • • • wires in the same cable with SUPPLY RETURN • equipment wires. ••• ••• FRONT PANEL v Backlit LCD Display 603 ^_ � Warmer or + Button 6.03 .7o _ AUTO �• AUTO ' _ ' b7 0 Cooler or - Button v 0 u 57 7 6 _ Q O Override Button O o o∎ _ _ _ 0 \ Heat or Cool Indicator Red = Heat, Green = Cool MODE FAN OUTSIDE PROGRAM FRESH AIR Venstar Inc. - Made in China - 06/06 - Patents Pending P/N 88 -454 Rev. 2 1 . .r SURVEYOR EQUIPMENT CONTROL PAC . MODEL Energy Management System INSTALLATION INSTRUCTIONS ECP4OO4 CAUTION DISCONNECT POWER TO ALL APPROPRIATE DEVICES BEFORE INSTALL - A ING THE EQUIPMENT CONTROL PAC. The Equipment Control Pac must be mounted inside the mechanical enclosure of the HVAC system or indoors. This product is not intended to withstand outdoor environments. This product is not intended for plenum use. WARNING ECP HVAC CONNECTIONS The Equipment Control Pac (ECP) should be connected to the HVAC equipment as shown below. Equipment Control Pac Mounted Wire from the Install on the Inside the HVAC Unit or indoors old thermostat Function ECP connector 5 1 ` terminal marked marked _ ] ] ? G or F Fan G — HVAC Y1, Y or C Cooling Y1 • _ — — I Terminal ^�— OUT20UT1 Y1 Y2 W1 W2 Bl W1, W or H Heating W1,O,B • • .. _ O 0 0 00 ®����are:oi- Rh, R, M, Vr, A Power R _ _ / C Common C ` J 0- 0 11 0 11 O/B Rev. Valve W1,0,B" R RRUX R C CKI CK2 G Power and . W2 2nd Stage Heat W2 Outputs Y2 2nd Stage Cool Y2 * C may not be used on all systems. ** If an 0 or B is present the ECP Jumpers must be properly configured (see back). ECP THERMOSTAT CONNECTIONS The Equipment Control Pac (ECP) should connected to the thermostat as shown below. Equipment Control Pac Mounted „ > Inside the HVAC Unit or Indoors Thermostat nnnnnnnnnnnnnnnnnn THERMOSTRT -- Backplate 0 I I Ii J � I1 0 a 0 o LJI�i` III i'I,' SO 0= �o oe DAT+ 4 �O 1 • g0 2 0= @ oo1 DAT- +24V g s O 0 4 0� GND ECP ECONOMIZER CONNECTIONS The Equipment Control Pac (ECP) should be connected to the Economizer as shown below. Equipment Control Pac Mounted Inside the HVAC Unit or Indoors ECONOMIZER Economizer Terminal 1 l 1 1 ON /OFF Y Block I l uu u 1 1 I I i 11 1I I 1 • D This terminal will have 24V AC whenever the Surveyor system A C coil is in the Occupied Mode. Venstar Inc. - Made in China - 09/04 - Patents Pending P/N 88 -454 Rev. 1 • MODEL , . .,. SURVEYDR � EQUIPMENT CONTRO L PAC : Energy.Managemenf System INSTALLATION INSTRUCTIONS ECP400 -2 ECP DATA CONCENTRATOR CONNECTIONS The Equipment Control Pac (ECP) should be connected to the Data Concentrator as shown below. Equipment Control Pac Mounted Data Concentrator Inside the HVAC Unit or Indoors COMMUNICATIONS Bus ■ A B GND I I I 1 - I Important Note: Depending on the number of ECP U U installed, the Communication Bus connections may be connected to one or more Equipment Control Pac A B GND before ultimate connection to the Data Concentrator as shown below. Equipment Control Pac #1 Equipment Control Pac #2 U u 'm ° • I• 1 Data Concentrator I I I I I I •■NNEN IIIIiiiiil III III l IUlliiiiilIII lil II ECP DIP SWITCH / JUMPER CONFIGURATION The Equipment Control Pac (ECP) should be set to the correct Dip Switch and Jumper configuration as shown Equipment Control Pac Mounted Equipment Control Pac Mounted Inside the HVAC Unit or Indoors Inside the HVAC Uni or Indoors A Unit Address = I B Unit Address =9 (1 +8 =9) — W • O °1�ID° 128 ° z ®° 128 m o . d 3* ® 64 ® 64 — Tff B 0 ® 32 CEO 32 Reversing ® 16 ® 16 • II= 4---Valve ® 8 ® 8 Heat Pump or Jumper ® 4 ® 4 Gas /Electric 0. • ® 2 ® 2 Jumper HP GAS ® 1 ® 1 To configure the ECP for heat pump operation, place the All Switches in the OFF position = 0. ADD all switches jumper on the HP side as shown. Reversing Valve polarity in the ON position to arrive at the setting. (0 or B) can also be set. In the diagram above the polarity is set for O. ECP LED ERROR CODES The Equipment Control Pac (ECP) LED's will blink to communicate a variety of errors as shown. Equipment Control Pac Mounted Inside the HVAC Unit or Indoors COMM O <O POLIER OR INDICAT E O$ W LED Function LED Interpretation b Indicator I I 1 1 1 I Blinks Rapidly Comm Is not communi- ( 5x per second) Status cating with Data u „�' Concentrator. III 111111 II II" 1 1 1 1 - 1 1 I 1 1 1 1 1 1 1 11 .( Blinks Slowly Comm Is not communi- (' /2x per second) Status cating with Sur - Constant veyor Thermostat. Comm Normal Operation Blinks Occas- Status P ionally Constant Power Normal Operation Indicator Venstar Inc. - Made in China - 09/04 - Patents Pending P/N 88 -454 Rev. 1 , SURVEYOR' OUTSIDE SENSOR " MODEL Energy Management System INSTALLATION INSTRUCTIONS OTS400 OUTSIDE SENSOR CONNECTIONS The enclosed Connector is used to attach the Outdoor sensor to the OUTDOOR TEMP terminals on the Equipment Control Pac circuit board (fig. 2). ONLY ONE OTS400 MAY BE INSTALLED PER SURV- EYOR SYSTEM. The three leads of the Connector attach to the sensor wires using the supplied wire nuts (fig. 3). To ensure proper operation do not use any shielded cable or run sensor wires in the same cable with equipment wires. Also, use a separate 3 conductor 18 gauge unshielded cable from the sen- sor to the connector. The Outside Sensor should be connected as shown below. 0 Connect the Black wire to RS -GRID, the White wire to RS and the Red wire to RS +V (fig. I). RS -GND �� B lack - � RS 0 White OUTDOOR TEMP fig. 1 RS + V Red •• Separate 1 1 1 \/ unshielded cable � 111 I I I : I T fig. 3 LEI � LEI I l u u fig. 2 0 Plug the Connector into the OUTDOOR TEMP term- inal of the Equipment Control Pac (fig. 2) and use the supplied wire nuts to connect the Connector to the sensor wires (fig. 3). NOTE: Only one OTS400 may be installed per Surveyor System. OUTSIDE SENSOR PLACEMENT Mount the Outside Sensor as shown in the diagram below. The Outside Sensor should be mounted facing North, preferably in a shaded - -�= J area, away from where it may get wet or receive an unnecessary amount � r of heat (fig. 4). h, _- fig. 4 Venstar Inc. - Made in China - 05/04 - Patents Pending P/N 88 -426 Rev. 1 0 4.Wire Low Flow ioii INf I DUCT SMOKE DETECTOR INDOOR A I R Q U A L I T Y 5 ( 't --- .„-----: , y Sze �` ,.„_...�s--"-- "'".,, „t / f ,-- � 'e,b}j,i �c t I �ij%i, _t * _ � �% C i — The Totaline P270- 2000PL is a 4 -wire photoelectric air duct smoke detector capable of sensing smoke in air velocities from 100 to 4,000 feet per minute (0.5 to 20.32 m /sec). This new detector features Low -Flow technology that enables duct smoke detection throughout a broad range of airflow environments. Many difficult to solve HVAC applications occur in low airflow duct applications where reliable smoke detection is critical. The P270- 2000PL with Low -Flow technology can detect smoke at air speed velocities of 100 feet per minute or greater, while continuing the same reliable performance to 4,000 feet per minute. Features: • Air Velocity rating from 100 to 4000 feet per minute • Easy and quick mounting to round or • Patented interconnectability for multi -fan rectangular ducts from 1' -12' wide shutdown (up to 10 air handlers) • Easy to clean • Patented telescopic sampling tube • UL recognized field- replaceable power and • Patented cover tamper trouble signal sensor boards • 24 VAC /DC or 120/240 VAC operation • Remote sounder and /or test station options • High -Low voltage barrier • Transparent cover for convenient visual inspection • Equipped with two DPDT Form C • UL 268A listed relay contacts • 3 -year warranty • Built -in reset button • • Outside mounting tabs WARNING: Duct smoke detectors have specific limitations. Duct smoke detectors are NOT a substitute for an open area smoke detector, NOT a substitute for early warning detection and NOT a replacement for a build regular fire detection system. Refer to NFPA 72 and 90A for additional duct smoke detector application information. Replacement Components Division • © Carrier Corporation 09/93 Rev E 11/02 www.totaline.com Literature Number 570 -936 Page 1 of 2 _•' C'do P270- 2000PL 4 -Wire Low Flow FOAM GASKETS Duct Smoke Detecto 0 GON DWINDLES I DETECTOR MI I II SFL TUBE r MOUSING '., FILTERS \ • SKIP--- - Specifications: PLABTI — ° ' 'LTERMINAL STRIP o,.•• \� i C UB E ♦/ � s/ x —",'.11.1 - ♦/ r�. T BOARD • Length: 14 -3/8 inches (37 cm.) • Operating Humidity Range: /. i ,; 1e�;,�r Width: 5 -1/2 inches (14 cm.) 10% to 93% relative humidity PLASTIC SELF-TAPPING ' At r ;; , t - POWER _ D epth: 2 -3/4 inches (7 cm.) noncondensing 1 er 4 �II \ COVER MOUNTING I% JI rr SCREWS • • Shipping Weight: 3.75 lbs. (1.7 kg.) • Air Duct Velocity: DETECTOR BOARD ' � p� ` • Operating Temperature Range: 100 to 4000 ft. /min. I I ' 32° to 131°F (0° to 55°C) (0.5 to 20.32 m /sec.) DETECTOR ��I! " Exploded View Of P270- 2000PL Duct Smoke Detector Electrical Ratings: I Power Supply Voltage 1 20 -29 VDC 1 24 VAC 50 -60Hz 1 120 VAC 50 -60Hz 1 220/240 VAC 50 -60Hz I ACCESSORY CURRENT LOADS AT 24 VDC CURRENT REQUIREMENTS (USING NO ACCESSORIES) DEVICE STANDBY ALARM Max. Standby Current 15 mA 35 mA RMS 25 mA RMS 15 mA RMS P271- APA451 12.5mA MAX 30mA MAX Max. Alarm Current _ 70 mA 125 mA RMS 35 mA RMS 25 mA RMS P271- PA400W OmA 15mA MAX CONTACT RATINGS P271- RA400Z OmA 10mA MAX Alarm Initiation Contacts (SPST) 2.OA @ 30 VDC /DC (0.6 Power Factor) P271- RTS451 -KEY 12mA* 7.5mA MAX* Alarm Auxiliary Contacts (DPDT) 10A @ 30 VDC WHEN A UNIT IS POWERED AT THE 120 VAC OR 220/240 VAC INPUT, NOTE: ALARM AUXILIARY CONTACTS MUST SWITCH 100mA MINIMUM AT 10A @ 250 VAC ANY COMBINATION OF ACCESSORIES MAY BE USED SUCH THAT 5 VDC. ALARM AUXIARY CONTACTS SHALL NOT BE CONNECTED TO THE GIVEN CURRENT LOADS TOTAL: INITIATING CIRCUITS OF CONTROL PANELS. USE THE ALARM INITIATION 60 mA OR LESS IN THE STANDBY STATE. CONTACT FOR THIS PURPOSE. 110 mA OR LESS IN THE ALARM STATE. Trouble Contacts (SPDT) 2.OA © 30 VDC (resistive) Parts Information: ITEM DESCRIPTION PART NO. ITEM DESCRIPTION I PART NO. ITEM DESCRIPTION I PART NO. 4 Wire Ionization Duct Smoke Detector P270 -20001 HIGH TEMPERATURE APPLICATIONS SAMPLING TUBES 4 Wire Duct Smoke Detector For Canada P270 -2000C High Temperature Ionization P270- 10001 -HT 1.5' Sampling Tube P271- ST -1.5 4 Wire Insulator Card P271- 157 - 1002 -01 Duct Smoke Detector 3' Sampling Tube P271 -ST -3 Replacement Filter Kit P271- F36 -09 -00 Replacement High Temperature Head P271-1451DHHT 5' Sampling Tube P271 -ST -5 Replacement 4 Wire Power Board P271 -A5064 10' Sampling Tube P271 -ST -10 Replacement Photo Sensor Board P271 -A5069 Exhaust Tube Extension P271- A2440 -00 Replacement Ion Sensor Board P271 -A5052 Telescoping Sampling Tube P271- T80 -71 -00 Replacement 4 Wire Installation Kit P271 -A1311 Accessories: L � I F F ' 1 „ . / lire ; c ` t E E Multi Signaling Accessory Annunciator with Piezo Alarm, Magnet Remote Test "Smoke" Lens, Signal Strobe with Mini- High Temperature Duct Smoke Station with Key and Remote LED Annunciator Alert Sounder, and Mini-Alert Sounder Detector, with Outdoor Enclosure ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO. SSK451 Multi- Signaling Accessory P271- SSK451 Mini - Sounder Red, 90dba P271- PA400R Replacement Test Magnet P271- MO2 -04 -00 Remote Annunciator Alarm LED P271- RA400Z Mini - Sounder White, 90dba P271- PA400W Replacement End Cap for P271- P48 -21 -00 Remote Annunciator Power & P271- APA451 Add -On Mini Strobe 24V Red P271- PS -24L0 Telescoping Tube Alarm LED, Horn Add -On Mini Strobe 24V White P271- PS24LOW Replacement Photo Insect Screen P271- S08 -39 -01 Remote Test Station P271- RTS451 Flush Mounting Plate, Red P271 -MP -F Smoke Lens Wall Mount P271- PS12 /24SLENSW Remote Test Station with Key P271- RTS451 -KEY Flush Mounting Plate, Beige P271 -FP -FB Photoelectric Plug -In Detector P271 -2451 Mini -Alert Sounder 12/24V Red P271- MA- 12/24D Semi -Flush Mounting Plate, Red P271 -MP -SF Metal Enclosure P271- ENCLOHITEMP Mini -Alert Sounder 12/24V Beige P271- MA- 12/24DB Semi -Flush Mounting Plate, Beige P271- MP -SFB Exhaust Tube Extension P271- A2440 -00 Waterproof Back Box 1 -1/2" Deep P271 -WBB Strobe/Sounder 24V Red P271- MA/SS -24L0 Back Box 2 -3/4" Deep P271 -BB -D Strobe /Sounder 24V Beige P271- MA- 12/24DB Test Module P271- MOD400R Replacement Cord for MOD400R P271- MOD45R S Reploce,ment Components • L aW & I9 © Carrier Corporation 09/93 Rev E 11/02 www.totaline.com Literature Number 570 -936 Page 2 of 2 V ( BROAN SPECIFICATION SHEET MODELS 502 & 503 SIDE DISCHARGE �w.a 1' FANS e Efficient, high - performance ventilation for a variety TYPICAL SPECIFICATION of wall or ceiling installations. Ventilator shall be Broan Model 502 (Model 503). FEATURES Ventilator shall have compact steel housing finished with GRILLE: electrically- bonded epoxy paint. Grille to be white polymeric. • Contemporary styled grille complements modem decor Motor assembly shall be removable and permanently • White polymeric grilles can be painted to match any lubricated. RPM shall not exceed 1600 (Model 502), 1725 decor (Model 503). MOTOR: • Motor assembly offers fast, easy "twist -lock" installation Air delivery shall be no less than 270 CFM and sound levels • Permanently lubricated, thermally protected, plug -in no greater than 8.0 Sones (Model 502), (160 CFM and 5.0 motor Sones — Model 503). All air and sound ratings shall be • Specially designed fan blade stays in balance - will not certified by HVI. Units shall be U.L. listed. distort HOUSING: • Installs easily in walls or ceiling • Steel housing 25 gage finished with rugged electrically - bonded epoxy paint MODEL 502 MODEL 503 • Built -in backdraft damper HOUSING HOUSING • Fits 3Y4' x 10" duct • Adjustable mounting brackets span from 14" to 24" 3a, •/* 3'a-' SPECIFICATIONS e eeP MODEL VOLTS AMPS RPM SONES CFM DUCT 502 120 1.7 1600 8.0 270 3%4' x 10" r :3, /4 %s 503 120 1.5 1725 5.0 160 314" x 10" p. MODEL MODEL 502 503 HVI -2100 CERTIFIED RATINGS comply with GRILLE h GRILLE TESTED/CERTIFIED new testing technologies and procedures � �- prescribed by the Home Ventilating Institute, • 2100 P'._ for off-the-shelf products, as they are available ° to consumers. Product performance is rated at 0.1 in. static pressure, based on tests conducted novm�n� "c. ";mwa in AMCA's state -of- the -art test laboratory. are a measure of humanly - perceived loudness, based on laboratory measurements. Broan- NuTone LLC, 926 West State Street, Hartford, WI 53027 (1- 800 - 637 -1453) REFERENCE QTY. REMARKS Project Location Architect " Engineer Contractor Submitted by Date 40B 99041065K B RBROAN SPECIFICATION SHEET WALL CAPS i IZa I aSa s ,� 6' I ) . ii I 1 56 S! Model 639 Model 843BL • For 31/4" x 10" duct • For 6" round duct • Spring - loaded backdraft damper and bird screen • Spring - loaded backdraft damper and bird screen • 24 GA CRCQ Steel, black electrically- bonded epoxy • 22 GA CRCQ Steel, black electrically- bonded epoxy finish finish Model 649 Model 641 • Same features as Model 639 • Same features as Model 843BL • .025 Aluminum - natural finish • .025 Aluminum - natural finish si 4Ir0i L S I Model 647 Model 885BL • For 7" round duct • For 3" or 4" round duct (4" to 3" transition included) • Spring - loaded backdraft damper and bird screen • Spring - loaded backdraft damper and bird screen • .025 Aluminum - natural finish • 24 GA CRCQ Steel, black electrically- bonded epoxy finish Broan - NuTone LLC, 926 West State Street, Hartford, Wisconsin 53027 (1- 800 - 637 -1453) REFERENCE QTY. REMARKS .. Project Location Architect Engineer Contractor Submitted by Date 50F 99042286J Is 6i 82 1 �. < - 2 3 I Z \ I41 Model 885AL 4 1 2 • For 3" or 4" round duct (4" to 3" transition included) / 8Ll • Spring - loaded backdraft damper and bird screen • .025 Aluminum - natural finish Model 613 1 --I • For 12" round duct 12 • High capacity � ? ,� /-- • Built -in backdraft damper and bird screen /i • .025 Aluminum - natural finish ,, 1 l 13 \ ±' T 1., L. ,, er00 1 • Model 643 • For 8" round duct 5a • O g • Built -in backdraft damper la J • .025 Aluminum - natural finish • 6 6 Q. Model 441 • Gravity dampers • Collar with bird screen for attaching 10" round duct �� • 24 GA CRCQ steel construction with aluminum louvers Model 645 / 6 54 • For 3" round duct • Polymeric construction - white finish / 6' � Model 450 Flexible Wall Ducting Kit '<'",.. 8 • Includes 5 ft. of 4 ", flexible, vinyl ducting, 4" diameter 4 1 1- metal duct connector, 2 duct clamps, 4" to 3" reducer and � a polymeric louvered wall vent 6c Model WVK1A Flexible Wall Ducting Kit • Includes 5 ft. of 4 ", flexible, 2 -ply metallic laminate ducting, Model 646 4" diameter metal duct connector, 2 duct clamps, 4" to 3" • For 6" round duct reducer and a polymeric louvered wall vent • Polymeric construction - white finish • Duct conforms to UL181 Class 1 air connector requirements • Not recommended for dryer venting B R ' � Broan - NuTone LLC, 926 West State Street, Hartford, Wisconsin 53027 (1- 800 - 637 -1453) October 5, 2010 RE: MECHANICAL TI Project Information Building Permit: MEC2010 -00442 Construction Type: 5 -B Tenant Name: AutoZone Occupancy Type: M /S -1 Address: 1340)(SW Pacific Hwy. Occupant Load: NA Area: NA Stories: 1 The plan review was performed under the State of Oregon Mechanical Specialty Code (OMSC) 2007 edition; and the State of Oregon Fire Code (OFC) 2007 edition. The following corrections need to be submitted for review prior to issuing of the permit 1) Provide details for connection of RTU to curb showing number and type of fasteners. When responding, provide an itemized letter stating in what way each numbered issue has been addressed in the revision. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Dan Nelson, Senior Plans Examiner (503) 718 -2436 dann @tigard- or.gov [Page Too Large for OCR Processing] [Page Too Large for OCR Processing]