Specifications (5) • .. .30 Form 4a Project Name: Autozone Store Page: SYSTEMS - GENERAL Applicability Plans /Specs Discussion of qualifying Show compliance by including a drawing sheet, detail number, exceptions on page 4 -25 specification section and subparagraph. 1. Applicablity (Section 1317) Is this form required? El Form Required. Complete form if a new HVAC system is being installed, or components of an existing HVAC system are being replaced (I.e., equipment, controls, ductwork, and insulation.) ❑ Exception. The building or part of the building qualifies for an exception from HVAC code requirements. Applicable code exception is Section 1317.1. Portions of the building that qualify: Area: Exception ❑ -1 ❑ -2 ❑ -3 Area: Exception ❑ -1 ❑ -2 ❑ -3 Area: Exception ❑ - ❑ - ❑ -3 ❑ Form Not Required. This project does not contain work required to comply with code. 2. Simple or Complex Systems (Section 1317.9 or 1317.10) G Simple System. Building contains only Simple HVAC System(s). Complete this form (4a) and equipment efficiency worksheets as required. Form 4b is not required. ❑ Complex System. Project includes a Complex System. Complete this form (4a), form 4b and equipment efficiency worksheets as required. 3. Equipment Performance (Section 1317.5) ❑ No New HVAC Equipment. The building plans do not call for new electrical HVAC equipment, combustion heating equipment, or heat - operated cooling equipment. IN Complies. All new HVAC equipment have efficiencies not less than those required by code. The following equipment efficiency worksheets are attached: 0 -4a ❑-4b ❑ -4c 0 -4c ❑-4e ❑mot 0 -4g 0 -4h ❑-4i 0 -4 4. Duct Insulation and Sealing (Sections 1317.7 & 1317.8) ❑ No Ducts. The building plans and specifications do not call for new HVAC ducts or plenums. G Complies. The plans and specifications call for all air - handling ducts and plenums to be insulated and sealed as reauired by Sections 1317.7 &1317.8. 5. Distribution Transformers (Section 1316.1) El No Distribution Transformers. The plans /specs do not call for new distribution transformers. ❑ Complies. All new distribution transformers comply with efficiency, testing, and labeling requirements of Section 1316.1.1. ❑ Exception. The project qualifies for an exception per Section 1316.1.1, Exceptiion: 0 -1 0 -2 0 -3 0-4 0 -5 0 -6 0-7 0 -8 0 -9 0 -10 ❑ -1 C7 -12 ❑ -1: 0 -14 Attach relevant documentation for a propriate exception. The plans /specs show compliance in ,q2°t,, the following locations: 2 610 l OFFICE COPY 4 -1 t 3 � ( C_ Compliance with OSSC, effective 04/01/07 Form 4a Project Name: Autozone Store Page: SYSTEMS - GENERAL 6. HVAC Controls (Section 1317.4) 6.1 System Thermostat /Zone Controls (Section 1317.4.1) 0 Complies. All new HVAC systems include at least one temperature control device responding to temperatures within the zones. ❑ Exception. HVAC system qualifies for an exception from zone control requirements. The applicable code exception is Section 1317.4.2, Exception 0-1 ❑ -2 Portions of the building that qualify: The plans /specs show compliance in the following locations: E -6 6.2 Off -hour Controls - Auto Setback or Shutdown (Section 1317.4.3) 0 Complies. Systems must have at least one of the following features: ❑ Control Setback Complies. Each system is equipped with automatic control capable of reducing energy through control setback during periods of non -use or alternate use of spaces served. O Equipment Shutdown Complies. Each system is equipped with controls capable of reducing energy use through automatic shutdown during periods of non -use or alternate use of spaces. HVAC systems with equipment shutdown are equipped with at least one of the following: 0 Programmable controls (1317.4.3.1 (1)) O Occupant sensor (1317.4.3.1 (2)) ❑ Interlocked to a security system (1317.4.3.1 (3)) ❑ Manually activated timers with 2 -hour operation max (1317.4.3.1 (4)) ❑ Exception. The building qualifies for an exception to the requirement for automatic setback or shutdown controls. The applicable code exception is Section 1317.4.3 Exception 0-1 0-2 The plans /specs show compliance in the following locations: E -6 /SPECS 6.3 Control Capabilities (Sec. 1317.4.2.1) O Complies. Zone thermostats are capable of being set to the temperatures described in Sec. 1317.4.2.1. Where used to control both heating and cooling, zone controls shall be capable of providing a temperature range or deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. ❑ Exception. The building qualifies for an exception to the deadband requirements. The applicable code exception is Section 1317.4.2.1 Exception 0-1 0-2 Portions of the building that qualify: The plans /specs show compliance in the following locations: E -6 /SPECS 6.4 Optimum Start Controls (Section 1317.4.3.2) ❑ Complies. Separate HVAC systems have controls capable of varying start -up time of system to just meet temperature set point at time of occupancy. O Exception. HVAC systems have a design supply air capacity not exceeding 10,000 cfm. The plans /specs show compliance in the following locations: 6.5 Heat Pump Controls (Section 1317.4.4) O No Heat Pump. The plans /specs do not call for a new heat pump ❑ Complies. All new heat pumps equipped with supplementary heaters are controlled to minimize the use of supplemental heat as defined in Section 1317.4.4. The plans/specs show compliance in the following locations: taY�: - .TS6d; ; #s 4 -2 Compliance with OSSC, effective 04/01/07 • Form 4a Project Name: Autozone Store Page: SYSTEMS - GENERAL 7. Economizer Cooling (Section 1317.3) ❑ No Cooling. The building plans do not call for a new fan system with mechanical cooling. II' Complies. Each new fan system has an air economizer capable of modulating outside -air and return -air dampers to provide up to 100 percent of the design supply air as outside air. ❑ Exception At least one new fan system qualifies for an exception. The applicable code exception is Section 1317.3, Exception ❑ -1 ❑ -2 ❑ -3 ❑ -4 ❑ -5 ❑ -6 ❑ -7 If Exception 3 is selected complete the following: (a) Total cooling capacity of exempt units (Btu /hr) (b) Total installed building cooling capacity (Btu /hr) ❑ Complies. Sum of exempt units rated at less than 54,000 Btu /hr is <240,000 Btu /hr or a/b < 0.10 (10% of total building cooling capacity). Unit Identifier of exempt units: The plans /specs show compliance in the following locations: RTU SCHEDULE 8. Economizer Pressure Relief & Integration (Section 1317.3.1 and 1317.3.2) ❑ No Economizers Required. Project does not contain a new fan system requiring economizers. ❑ Overpressurization Complies. The drawings specifically identify a pressure relief mechanism for each fan system that will relieve the extra air introduced by the economizer. G Integration Complies. Economizer is capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. ❑ Exception. The applicable exception is Section 1317.3.2, Exception El - ID -2 The plans /specs show compliance in the following locations: RTU SCHEDULE 9. Hot Gas Bypass (Section 1317.5) El No Hot Gas Bypass ❑ Complies. See allowable amount of hot gas bypass as a percentage of total cooling capacity in table below. Unit ID Rated Cooling Capacity Hot Gas Bypass Capacity a ;: Allowable Hot Gas Bypass An Rated Cooling Capacity Max Hot Gas Bypass •• <240,000 Btu /hr 50% > 240,000 Btu /hr 25% ❑ Exception. Unitary packaged system with cooling capacity no greater than 90,000 Btu /h 4 -3 Compliance with OSSC, effective 04/01/07 Form 4a Project Name: Autozone Store Page: SYSTEMS - GENERAL 10. Shutoff Dampers (1317.4.3.3) El Not Required. Shutoff dampers are not required on this project. ❑ Complies. Each outdoor air supply & exhaust system shall be equipped with motorized dampers. ❑ Exception. The building qualifies for an exception to the motorized damper requirement. The applicable code exception is Section 1317.4.3.3 Exception ❑ -1 ❑ - ❑ -3 ❑ -4 ❑ -5 ❑ -6 The plans /specs show compliance in the following locations: EXCEPTION 4 10.1. Shutoff Damper Controls (Section 1317.4.3.3.1) ❑ Complies. Outdoor air supply and exhaust systems shall be provided dampers that automatically shut when systems or spaces served are not in use or during building warm -up, cooldown, or setback. ❑ Complies. Stair and shaft vents are capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. The plans /specs show compliance in the following locations: 10.2. Motorized Damper Leakage (1317.4.3.3.2) ❑ Complies. Motorized outdoor air supply and exhaust air dampers have a maximum leakage rate of 4 cfm /ft2 at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998. ❑ Exception. Packaged HVAC equipment may have maximum leakage rate of 20 cfm /ft at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998. The plans /specs show compliance in the following locations: 11. Piping Insulation (Section 1314) ❑ No New Piping. The building plans and specifications do not call for new piping serving a heating or cooling system or part of a circulating service water heating system. G Complies. All new piping serving a heating or cooling system or part of a circulating service water heating system complies with the requirements of the Code, Section 1314.1. ❑ Exception. New piping qualifies for exception: Section 1314.1, Exception D1 -1 ❑ -2 12. Occupancy Ventilation El Complies. Mechanical ventilation systems provide the required amount of ventilation is indicated in plans /specifications as specified in Chapter 4 of the Oregon Mechanical Specialty Code. ❑ Complies. Natural ventilation systems provide required amount of ventilation as certified by a reg- istered architect or engineer as specified by Section1203.4.1, Exception. Attach worksheet 4m. The plans /specs show compliance in RTU SCHEDULE the following locations: The plans /specs show compliance rS? `� �: ;� ,. � on the following pages: 4 -4 Compliance with OSSC, effective 04/01/07 Form 4a Project Name: Autozone Store Page: SYSTEMS - GENERAL 13. High Occupancy Ventilation (Section 1317.2.2) ❑ Complies. HVAC systems with ventilation air capacities of 1,500 CFM or greater that serve areas having an average occupant load of 20 square feet per person or less from Table 1004.1.2 have a means to automatically reduce outside air intake. Identify applicable systems: Plans /specs indicate where equipment (i.e. carbon dioxide sensor) and sequence is specified: ❑ Exception. HVAC systems are equipped with an energy recovery device with at least 50% recovery effectiveness. D No High Occupancy Systems. Project does not contain an HVAC system as described above: 14. Exhaust Air Heat Recovery (Section 1318.3) D Not Regulated. HVAC system does not have: 1) design supply air cap. of >10,000 cfm, and 2) min. outside air supply >70 %, and 3) at least 1 exhaust fan rated at 75% of min outside air supply. ❑ Complies. Heat recovery system increases outside air temperature by 20 °F (Climte Zone 1) or 30 °F (Zone 2) and has provision to provide bypass during air economizer mode. ❑ Exception. An HVAC system qualifies for an exception to this requirement. Applicable exception from Section 1318.3 Exception 0- ❑ -z 0-3 0-4 0-5 0-6 0-7 The plans /specs show compliance in the following locations: 15. Large Volume Fan. Systems (Section 1318.4.2.4) D Not Regulated. The building plans or specifications do not call for fan systems over 15,000 CFM that serve a single zone and function for the purpose of temperature control. ❑ Complies. Fan systems are equipped with variable frequency drive or two speed motor to reduce airflow as required by Section 1318.4.2.3. The plans /specs show compliance in the following Inrntinnc• 16. Variable Speed Drives (Section 1317.10.3.1) D Not Regulated. The building plans or specifications do not call for fan and pump motors 10 horsepower and greater that serve variable -flow air or liquid systems. ❑ Complies. All fan and pump motors 10 hp and greater which serve variable -flow air or liquid systems are controlled by a variable -speed drive. ❑ Exception. The building qualifies for an exception to the variable -speed drive requirement. Portions of the building that qualify: Applicable code exception is Section 1317.10.3.1, Exception The plans /specs show compliance in the following Inrntinnc- 17. Service Water Heating (Sec. 1315) El No New Water Heating. The building plans and specifications do not call for new water heaters, hot water storage tanks or service hot water distribution systems. D Complies. All new water heaters, hot water storage tanks or service hot water distribution systems comply with the requirements of the Section 1315. ❑ Exception. The applicable code exception is Section: Exception: . �5; ; ;4; Portions of the building that qualify: The plans /specs show compliance in the following locations: 4 -5 Compliance with OSSC, effective 04/01/07 i Form 4a Project Name: Autozone Store Page: SYSTEMS - GENERAL 18. Swimming Pools, Spas and Hot Tubs (Section 1315.5) 12 No New Pools. The building plans and specifications do not call for new, swimming pools, spas or hot tubs. ❑ On /Off Controls Complies. Spa and hot tub heaters are equipped with a readily accessible ON /OFF switch as required by Section 1315.5.1. ❑ Ventilation Controls Complies. Pool ventilation system is controlled based on humidity. ❑ Cover Complies. All heated pools, hot tubs and spas are equipped with a cover. ❑ Heat Recovery Complies. Pools, Spas, and hot tubs, over 200 ft utilize recovered heat as required by Section 1315.5.3. ❑ Exception. Heat recovery is not necessary as pool is heated by renewable energy or waste heat recovery sources capable of providing at least 70 percent of the heating energy required over an operating season. 19. Fume Hoods (Section 1317.2.1.) No Fume Hoods. The building plans do not call for fume hood systems that have a total exhaust rate greater than 15,000 cfm. ❑ Complies. Fume hood systems have at least one of the following features: El Variable air volume hood exhaust and room supply systems capable of reducing exhaust and makeup air volume to 50% or less of design values. ❑ Direct makeup (auxiliary) air supply equal to at least 75% of the exhaust rate, heated no warmer than 2° F below room set point, cooled no cooler than 3° F above room set point, no humidification added, and no simultaneous heating and cooling used for dehumidification control. ❑ Heat recovery systems to precondition makeup air from fume hood exhaust in accordance with 1318.3 - Exhaust Air Energy Recovery, without using any exception. The plans /specs show compliance in the following locations: 20. Parking Garage Ventilation (Section 1317.2.3) El No Enclosed Garages. The building plans and specifications do not call for enclosed Group S -2 parking garages with a ventilation exhaust rate greater than 30,000 CFM. ❑ Complies. The plans and specifications call for carbon monoxide sensing devices as required by Section 1317.2.3. ❑ Exception. Open parking garages. 21. Kitchen Hoods (Section 1317.11) E Not Regulated. The plans /specs do not call for any new kitchen hoods with exhaust capacity greater than 5,000 cfm each. ❑ Complies. All new kitchen hoods with a total exhaust capacity greater than 5,000 cfm have at least 50 percent of the required makeup air; (a) unheated or heated to no more than 60 °F; and (b) uncooled or evaporatively cooled. ,.;,, The plans /specs show compliance in the following locations: 22. Outside Heating Systems (Section 1317.12) G No Outside Heating Systems. The plans /specs do not call for new permanently installed heating systems outside the building. ❑ Complies. All new permanently installed outside heating systems are radiant gas fired systems controlled by an occupancy sensor or timer switch as required by Section 1317.12. 4 -6 Compliance with OSSC, effective 04/01/07 Form 4b Project Name: Autozone Store Page: COMPLEX HVAC SYSTEMS Applic- 1. Simple or Complex Systems (Section 1317.9, 1317.10 and 1318) ability Note: This form is required for complex systems only. If your plans qualify as a simple system Discussion of as defined by the code, this form is not required. qualifying excep- tions in instructions section. 2. Air Transport Energy (Section 1318.4.2) O Not Regulated. Each HVAC system does not have total fan nameplate horsepower of 7.5 HP Fan Motor or greater (include sum of all supply, return, & exhaust fans operating at design conditions). Energy ❑ Brake Horsepower Complies. The energy demand of all HVAC fan systems meets code See Section 1318.4.2 for requirements. Complete and attach Worksheet 41. maximum horse- ❑ Nameplate Horsepower Complies. Selected fan motors have nameplate ratings no larger power allowed. than is allowed by Section 1218.4.2.3. (Complete Worksheet 4L.) ❑ Exception. Section 1318.4.2, Exception 0-1 0 -2 0 -3 0 -4 Portions of the building that qualify: The plans /specs show compliance in the following locations: Cooling 3. Cooling Tower Fans (Section 1317.5.4.1) Tower Fans 0 No Cooling Tower There is no cooling tower in this project. ❑ Complies. Cooling tower fans have control devices that vary flow by controlling leaving fluid temperature or condenser temperature /pressure of the heat rejection device. The plans /specs show compliance in the following locations: 4. Simultaneous Heating and Cooling (Section 1318.2.1) ❑ No Cooling. The building HVAC system has no cooling. O Complies. Controls prevent reheating, recooling or mixing of mechanically heated and mechanically cooled air. ❑ Exception. Code exception is Section 1318.2.1, Exception 0-1 0-2 0 -3 0 -4 ❑ -s If exception 1 is used, complete and attach Worksheet 4k Portions of the building that qualify: SPECS The plans /specs show compliance in the following locations: 5. Electric Motor Efficiency (Section 1317.10.3 & Table 13 -T) ❑ Not Regulated. There are no NEMA Design A &B squirrel cage,T -frame induction, permanently wired polyphase motors of one horsepower or more which serve built up HVAC systems. O Complies. The efficiency of all regulated motors meets code requirements. Exceptions 0 Exception. Section 1317.10.3, Exception ❑ - ❑ -2 Discussion of qualifying Portions of the building hat qualify: exceptions in g q ua fy instructions section. The plans /specs show compliance in the following locations: 6. VAV System Static Pressure Reset Controls (Section 1318.2.3) O Not Regulated. The building plans or specifications do not call for a VAV system controlled by a static pressure sensor or direct digital control of individual zone boxes. ❑ Complies. The system static pressure set point automatically resets to the lowest point %' °`- : possible while still providing the required air flow to the zones with the greatest demand. ` ',. ❑ Exce Exception. Section 1318.2.3, Exception �_ "i.p' p p f"t _. 4,8 The plans /specs show compliance in `\ the following locations: 4 - Compliance with OSSC, effective 04/01/07 • Form 4b Project Name: Autozone Store Page: COMPLEX HVAC SYSTEMS 7. VAV Terminal Units (Section 1317.4.2.1) O Not Regulated. Project does not contain VAV terminal units. ❑ Complies. VAV terminal units are programmed to operate at the minimum airflow setting without addition of reheat when the zone temperature is within the set deadband. Complete Worksheet 4k. O Exception. Section 1317.4.2.1. Exception O -1 0 -2 The plans /specs show compliance in the following locations: 8. Supply - Air Temperature Reset Controls (Section 1318.2.5) O Not Regulated. The building plans or specifications do not call for multiple zone HVAC systems. ❑ Complies. Multiple zone HVAC systems include controls that automatically reset the supply -air temperatures in response to building loads or outside air temperature. ❑ Exception. The building qualifies for an exception to the supply -air reset controls requirement. Applicable code exception is Section 1318.2.5, Exception 0-1 0 -2 0 -3 Portions of the building that qualify: The plans /specs show compliance in the following locations: 9. Chilled and Hot Water Temperature Reset Controls (Section 1318.2.4) O Not Regulated. The building plans or specifications do not call for chilled or hot water systems with a design capacity exceeding 300,000 Btu /hr. • ❑ Complies. Chilled and hot water systems include controls that automatically reset supply water temperatures by representative building loads or by outside air temperature. ❑ Exception. Section 1318.2.4, Exception 0- 0- Portions of the building that qualify: The plans /specs show compliance in the following locations: 10. Separate Air Distribution Systems (Section 1318.2.7) O Not Regulated. The building plans or specifications do not call for zones with special process temperature or humidity requirements. O Complies. Separate air distribution systems serve zones with special process temperature or humidity requirements from those zones serving only comfort conditions, or supplementary control provisions are included so primary systems are specifically controlled for comfort purposes only. O Exception. Section 1318.2.7, Exception 0 0 -2 Identify zones with special process requirements: The plans /specs show compliance in the following locations: 11. Zone Isolation Controls (Section 1318.2.6) O Not Regulated. Building plans or specifications do not call for HVAC systems serving multiple occupancies or floors with >240,000 Btu /hr cooling capacity, or >300,000 Btu /hr heating capacity. O Complies. HVAC systems serving multiple occupancies or floors with >240,000 Btu /hr cooling capacity, or >300,000 Btu /hr heating capacity are equipped with isolation devices capable of automatically shutting off supply air to and from each isolated area. Each isolated area is controlled independently and satisfies temperature setback (Section 1317.4.2) and optimum start control requirements. Central fan system air volume is reduced through fan speed reduction. The plans /specs show compliance in the :fl following locations: .cash - ,u '':. .6. ..w., nrF. _T ♦'. . >' „' '. r:.' .: vu. .ry F H c I — •.- Compliance with OSSC, effective 04/01/07 Form 4b Project Name: Autozone Store Page: l COMPLEX MAC SYSTEMS 12. Humidity Controls (Section 1318.2.2) O No Moisture Added to Building. The building plans do not call for means to add moisture to maintain specific humidity levels. ❑ Complies. All new humidity control systems equipped with a humidistat when required. All humidifier preheating devices have an automatic value to shut off preheat when humidification is The plans /specs show compliance in the following locations: 13. Hydronic System Controls (Section 1318.2.8) O No Hydronic System. The building plans or specifications do not call for a new hydronic system. ❑ Complies. The hydronic system complies as follows: 13.1 Variable Flow Controls (Section 1318.2.8.4) ❑ System does not have a 10 hp or greater motor ❑ Complies. System has controls capable of varying pump flow The plans /specs show compliance in the followina locations: 13.2 Three -Pipe System (Section 1318.2.8.1) ❑ System does not have a common return system (a three -pipe system) for both hot water and chilled water. 13.3 Two -Pipe Changeover System (Section 1318.2.8.2) ❑ System is not a Two -Pipe Changeover System ❑ Complies. System is: a. Designed to allow a deadband between changeover from one mode to the other of at least 15 °F outside air temperature. b. Designed to operate and provided with controls that will allow operation in one mode for at least four hours before changing over to the other mode. c. Provided with reset controls that allow heating and cooling supply temperatures at the changeover point to be no more than 30 °F apart. The plans /specs show compliance in the followina locations: 13.4 Hydronic (Water Loop) Heat Pump System (Section 1318.2.8.3) ❑ System is not a Hydronic (Water Loop) Heat Pump System ❑ Complies. Hydronic heat pumps connected to a common heat pump water loop with central devices for heat rejection (e.g., cooling tower) and heat addition (e.g., boiler) have the following: a. Controls installed capable of providing a heat pump water supply temperature deadband of at least 20 °F between initiation of heat rejection and heat addition by the central devices (e.g., tower and boiler). b. Closed- circuit tower (fluid cooler) has either an automatic valve installed to bypass all but a minimal flow of water around the tower (for freeze protection), or low- leakage positive closure dampers. c. Open- circuit tower installed directly in the heat pump loop has an automatic valve installed to bypass all heat pump water flow around the tower. Open - circuit towers used in conjunction with a separate heat exchanger to isolate the tower from the heat pump loop are controlled by shutting down the circulation pump on the cooling tower loop. a :.. d. A two- position valve at each hydronic heat pump for hydronic systems � �,tw'fi3 having a total pump system power exceeding 10 hp. The plans /specs show compliance in the following locations: 4-9 Compliance with OSSC, effective 04/01/07 Worksheet 4a Project Name: Autozone Store Page: I , UNITARY AIR CONDITIONER - AIR COOLED 1 Equipment (a) (b) (c) (d) ( (f) Proposed Performance Discussion of equipment Cooling Seasonal or Compliance New or ratings and equipment Equip. ID Model Designation Capacity Steady State Part Load Schedule (A -E) Replacemnt? • definitions on page 4 -19. RTU1,2 48HJD008 92.9 MBH 11 NEW Required Indicate source of information Document D ARI Unitary Directory, Section AC, page: ation ❑ ARI Applied Products directory, Section ULE, page: ❑ Product data (Attach data furnished by the equipment supplier, I.e., "cut sheets ") Code Required Cooling Capacity (btu/hr) Minimum Rating Efficiencies Compliance Seasonal or Schedule Equipment Type Over But not over - Steady State Part Load New' 0 65,000 na 13 SEER Single Package Without a Replacement • 0 65,000 na 9.7 SEER A Heating Section or With Electric 65,000 135,000 10.3 EER n/a This schedule of equip Resistance Heat All 135,000 240,000 9.7 EER n/a ment efficiencies was 240,000 760,000 9.5 EER 9.7 IPLV reformatted from code, 760,000 - 9.2 EER 9.4 IPLV Table 13 - L. New * 0 65,000 na 13 SEER Split System Without a Heating Replacement' 0 65,000 na 10 SEER B Section or With Electric 65,000 135,000 10.3 EER n/a Resistance Heat All 135,000 240,000 9.7 EER n/a 240,000 760,000 9.5 EER 9.5 IPLV 760,000 - 9.2 EER 9.2 IPLV New * 0 65,000 na 13 SEER Single Package With a Heating Replacement' 0 65,000 na 9.7 SEER C Section Other Than Electric 65,000 135,000 10.1 EER n/a Resistance All 135,000 240,000 9.5 EER n/a 240,000 760,000 9.3 EER 9.5 IPLV 760,000 - 9.0 EER 9.2 IPLV r9 -- New' 0 65,000 na 13 SEER , ` ... r Split System With a Heating R eplacement' 0 65,000 na 10 SEER ``' % ' ° 65,000 135,000 10.1 EER n/a o Other Than Electric . =" T D Sectin Oth Th El '•:`ti;: .4 < : 135,000 240,000 9.5 EER n/a --.,•,;4);-if,--- Resistance All 240,000 760,000 9.3 EER 9.7 IPLV 760,000 - 9.0 EER 9.4 IPLV E Condensing Unit Only All 135,000 - 10.1 EER 11.2 IPLV • Equipment is a new installation or replaces existing equipment 4 -11 Compliance with OSSC, effective 04/01/07 ' ' Envelope Compliance Test Results AutoZono _ Store _#375G.134O5SVV Pacific HVVY Project Summary Information Project Name AutoZono_S0om_#3756 Address 13405 SW Pacific HWY City/State/Zip Tlgard, OR 97223 Contact Name Danny E Doss P.E. Contact Phone 479.631.1712 p pUo? Climate Zone 1 Donoh p i Condidon�/Floor A,�� (n 6446 Gross � Area (�2) 634.6 VVindovvAma Vt2) 360 Window Wall Ratio 0.08 IGmsn Roof Area �2[ ' iO440 SkyUghtAma(M2 -- -----( /SkYVght Roof R»U» I77 r���[ho!Area` 140 • ' Compliance Summar ;PASSES Miscellaneous 8 . SpauoName ' — ' --� ------ !Over 7O%v} space served b` economizer? , Windows utilize shading L }gevicos? �u�Zone_R�aiiSkx�_# | yES - [YE�� _- devices? . Fenestration Performance User Name FU-Center [[Over�[ SC-Center SHGC _I Glass Color 1 Defined � V. �nnlLuoors'userum/n | o��u ou 1i46 0.40 Green Man_Door / O.00 0.24 0.00 / 0.00 |n�. Looding_Doo/ 0.00 012 |O.O0 0.00 | n.a. DouNe_g|sdng_- '0.45 0.54 0.56 0,49 ! Green i 1'2 | _--_ ' • L ' Roof and Floor Insulation Description [Surface Typo UoerName ' - - - -- R hv ---- � | --- !1��«� ���o�V��g ;Roof | Roof — n.a. ���� Wall lnsulation Description !Surface Type User Name !Material 1R-cavity 1R-sheathing Wall, above grade Walls Uninsulated or Masonry n.a. 'n.a. -- • ; with Integral Insulation _ | Slab Floor Insulation Description | Surface Type !User Name | Insulation R'vu|my | Insulation Position l — CodeComp 5.0 06/23/ 10 Page 1 Envelope Compliance Test Results AutoZone_Store_ #3756, 13405 SW Pacific HWY Project Component Descriptions Fenestration Description* User Name Opening Type Class Frame Type Entry_Doors Glass Door Entry/exit Aluminum without Thermal Break Swinging Man_Door Opaque Door Entry/exit n.a. Swinging Loading_Door Opaque Door Coiling n.a. Double_glazing_ _1 /2 "_air_space Window Fixed Aluminum with Thermal Break * Manufacturers Specification sheet shall be provided when using tested glass U- factor or shading coefficient data (center -of- glass values) with this Output Report. Include NFRC data for window assembly U- factor and SHGC when applicable. Walls Description Description R -value User Defined * 1 Gypsum or plaster board 0.5" 0.45 - Wall Metal Framing 2x4 16" o.c. R -13 ; 6.0 - 8" lightweight CMU with vermiculite fill, cores filled with 2.31 - grout/steel @ 40" o.c. _ • Documentation supporting User Defined input values shalt be provided with this Output Report. Roof Description I Description j R -value I User Defined * I ' Roofing built-up 1 -- I 9 P 30.0 _ YES _ * Documentation supporting User Defined input values shall be provided with this Output Report. Shading Device Descriptions Overhang Descriptions I Opening User Name Orientation No. of 1 Window : Window Projection* Distance ** _ _ _ I _ I Windows 1 Width _ Height * Projection distance from plane of wall, outwards. ** Distance is measurement from top of window to bottom of shading device. CodeComp Summary Cooling Loads (MBtu /y) i Heating Loads (MBtu /y)_ - - _ Space , Baseline 1 Proposed I Baseline [Proposed _ 1 AutoZone_Retail_Store_ #3756 1 38 36 1 216 1125 1 Total 138 36 1 216 ; 125 Project Space(s) Descriptions AutoZone_Retail_Store_ #3756 Descriptions OSSC Occupancy M - Retail /Mercantile _ Occupancy /Use Retail stores _ Conditioned Floor Area (ft2) 6446 Gross Wall Area (ft2) 6346 Window Area (ft2) ; 356 i Window Wall Ratio i 0.06 I Gross Roof Area (ft2) i 6446 ; Gross Skylight Area (ft2) 0 I Skylight Roof Ratio ' 0.00 — Gross Door Area (ft2) _ 140 _ Surfaces User Name Type Gross Area* Orientation Construction Notes ** Walls Wall 1805 South Walls n.a. Wall Wall 1368 West Walls n.a. Wall Wall 1805 North Walls n.a. Wall Wall 1368 East Walls n.a. Roof Roof 6446 n.a. Roof Total 12792 * If surface type is slab, value entered under Gross Area will be lineal feet of slab perimeter. ** Demising is a component separating conditioned from either unconditioned or semi - conditioned spaces. Examples may include: wall between office and warehouse, floor above crawlspace, and floor above parking garage. CodeComp 5.0 06/23/10 Page 2 • Envelope Compliance Test Results AutoZone_Store_ W #3756, 13405 SW Pacific HY Openings User Name Type Area Orientation Fenestration Parent Surface Notes Storefront_Glass Window 356 South Double glazing_- Walls n.a. _1/2 "_air_space Entry_Doors Glass 42 South Entry_Doors Walls n.a. Door Man_Door Opaque 42 West Man_Door Wall n.a. Door Loading_Door Opaque 56 East Loading_Door Wall n.a. Door Total 496 I Software Components Information • • Component Version Date CodeComp.EXE 5.00.0002 i 3/24/2008 eaDataStructureCodeComp.DLL 5.00.0002 3/24/2008 eaCodeComp.DLL 5.00.0002 13/24/2008 , CodeComp 5.0 06/23/10 Page 3 COMcheck Software Version 3.7.1 Interior Lighting Compliance Certificate 2006 IECC Section 1: Project Information Project Type: New Construction Project Title : Autozone Store #3756 Construction Site: Owner /Agent: Designer /Contractor: Tigard, OR 97223 Autozone Design and Construction Danny Doss 123 S. Front Street Advanced Consulting Engineers, Inc. Memphis, TN 38103 132 Kelley Dr Rogers, AR 72757 479 - 631 -1712 acei@advengineers.com Section 2: General Information Building Use Description by: Activity Type Activity Types) Floor Area Retail 6446 Section 3: Requirements Checklist Interior Lighting: 1. Total proposed watts must be less than or equal to total allowed watts. Allowed Watts Proposed Watts Complies 9669 7949 YES Controls, Switching, and Wiring: c g 2. Independent controls for each space (switch /occupancy sensor). Exceptions: Areas designated as security or emergency areas that must be continuously illuminated. Lighting in stairways or corridors that are elements of the means of egress. 4 - 3. Master switch at entry to hotel /motel guest room. 0-4. Individual dwelling units separately metered. 7 5. Each space provided with a manual control to provide uniform light reduction by at least 50 %. Exceptions: Only one luminaire in space; An occupant- sensing device controls the area; The area is a corridor, storeroom, restroom, public lobby or sleeping unit. Areas that use less than 0.6 Watts /sq.ft. S Automatic lighting shutoff control in buildings larger than 5,000 sq.ft. . Exceptions: Sleeping units, patient care areas; and spaces where automatic shutoff would endanger safety or security. J 7. Photocell /astronomical time switch on exterior lights. Exceptions: Lighting intended for 24 hour use. 4 8. Tandem wired one -lamp and three -lamp ballasted luminaires (No single -lamp ballasts). • Exceptions: Project Title: Autozone Store #3756 Report date: 06/23/10 Data filename: X: \COMCheck Files\Advanced Energy Solutions \azpr4754.cck Page 1 of 5 Electronic high- frequency ballasts; Luminaires on emergency circuits or with no available pair. Section 4: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2006 IECC requirements in COMcheck Version 3.7.1 and to comply with the mandatory requirements in the Requirements Checklist. FE26a5\N P F . � cZ /zp /A Name - Title Signature / Date Project Notes: Provided By: Jonathan Doss Advanced Energy Solutions LLC P.O. Box 427 Rogers, Arkansas 72757 -0427 • Project Title: Autozone Store #3756 Report date: 06/23/10 Data filename: X: \COMCheck Files\Advanced Energy Solutions \azpr4754.cck Page 2 of 5 COMcheck Software Version 3.7.1 Interior Lighting Application Worksheet 2006 IECC Section 1: Allowed Lighting Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts / ft2 (B x C) Retail 6446 1.5 9669 Total Allowed Watts = 9669 Section 2: Proposed Lighting Power Calculation A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. Retail (6446 sq.ft.) T8 / T12 Fluorescent 1: A: Suspended 8ft. Fluorescent / 96" T8 ES 60W / Electronic 2 60 95 5700 T8 / T12 Fluorescent 2: C: Wall Mtd. Fluorescent / 48" T8 32W / Electronic 1 2 32 64 Linear Fluorescent 3: G /H: Suspended 16ft.Tandem Fluor. / 96" T8 ES 60W / Electronic 2 23 95 2185 Total Proposed Watts = 7949 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Proposed Watts is greater than or equal to zero, the building complies. Total Allowed Watts = 9669 Total Proposed Watts = 7949 Project Compliance = 1720 'N �,.,�f,/,`{" eN"'N' .N/ � C p '99//6 /�9/¢ / itiS4jEo w G 'f y� k jdiii U NG t C YgG,g;A/�// /i % P v . , , . n .. Project Title: Autozone Store #3756 Report date: 06/23/10 Data filename: X: \COMCheck Files\Advanced Energy Solutions \azpr4754.cck Page 3 of 5 COMcheck Software Version 3.7.1 Exterior Lighting Compliance Certificate 2006 IECC Section 1: Project Information Project Type: New Construction Project Title : Autozone Store #3756 Construction Site: Owner /Agent: Designer /Contractor: Tigard, OR 97223 Autozone Design and Construction Danny Doss 123 S. Front Street Advanced Consulting Engineers, Inc. Memphis, TN 38103 132 Kelley Dr Rogers, AR 72757 479 - 631 -1712 acei @advengineers.com Section 2: Exterior Lighting Area /Surface Power Calculation A B C D E F Exterior Area/Surface Quantity Allowed Tradable Allowed Proposed Watts Wattage Watts Watts / Unit (C x D) Illuminated length of wall or surface 334 ft 5 No 1670 1365 Total Tradable Watts* = 0 0 Total Allowed Watts = 1670 Total Allowed Supplemental Watts** = 84 *Wattage tradeoffs are only allowed between tradable areas /surfaces. ** A supplemental allowance equal to 5% of total allowed wattage may be applied toward compliance of both non - tradable and tradable areas /surfaces. Section 3: Exterior Lighting Fixture Schedule A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. Illuminated length of wall or surface (334 ft): Non - tradable Wattage HID 1: D: Metal Halide Wall Pack / Metal Halide 150W / Standard 1 7 195 1365 Total Tradable Proposed Watts = 0 Section 4: Requirements Checklist Lighting Wattage: 1. Within each non - tradable area/surface, total proposed watts must be less than or equal to total allowed watts. Across all tradable areas /surfaces, total proposed watts must be less than or equal to total allowed watts. Compliance: Passes. Controls, Switching, and Wiring: y2. All exemption claims are associated with fixtures that have a control device independent of the control of the nonexempt lighting. �3. All lighting fixtures are controlled by a photosensor or astronomical time switch that is capable of automatically turning off the fixture when sufficient daylight is available or the lighting is not required. Exceptions: Covered vehicle entrance /exit areas requiring lighting for safety, security and eye adaptation. Exterior Lighting Efficacy: Project Title: Autozone Store #3756 Report date: 06/23/10 Data filename: X: \COMCheck Files\Advanced Energy Solutions \azpr4754.cck Page 4 of 5 4. All exterior building grounds luminaires that operate at greater than 100W have minimum efficacy of 60 lumen /watt. Exceptions: Controlled by motion sensor or exempt from consideration under the provisions of Section 505.6.2. ` _ fa a,. . Section 5: Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2006 IECC requirements in COMcheck Version 3.7.1 and to comply with the mandatory requirements in the Requirements Checklist. e 0 03% Name - Title Sig , ure . Date ___ _ — Project Title: Autozone Store #3756 �._.�._ . Report date: 06/23/10 Data filename: X: \COMCheck Files\Advanced Energy Solutions \azpr4754.cck Page 5 of 5