RE HORMEL BUILDIN — Si TE REVIEW
Project Information
Site Permit: SIT2005 -00030 ' Construction Type: V - B
Tenant Name: Hornet Building Occupancy Type: B/S 1
Address: 14775 SW 74' Ave Occupant Load: NA .
Area 6,656 sq ft Stones: 2
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC)
2004 edition; and the Tualatin Valley Fire & Rescue Fire & Life Safety Requirements for Fire
Department Access and Water Supplies (Based on the 2004 Oregon Fire Code). The following
information is required prior to the issuance of a Site Permit:
1. Do to location on property at the NorthSide; a 2 hour rated wall will be required. Provide
information showing building distance to property line to determine opening protection
requirements. Is a parapet wall required?
3. " Complete the enclosed permit application clarifying the Excavation, Grading and Fill
volumes.
4. Complete the enclosed "TVF &R FIRE FLOW and HYDRANT WORKSHEET". The
allowable area permitted and the number of hydrants required will be based on the
worksheet. ;
5. Underground Fire Fighting Wa ter Supply. Provide a bigger view and with more detail of
the thrust blocking details including cut sheets and installation instructions for any
mechanical joint connections. Provide supply pipe burial depth, piping sizes and materials,
valve equipment cut sheets, vault details, equipment in vaults, details for hydrants and Fire
Department Connection (FDC) location that are necessary for the installation of the fire
service. All valves shall be listed for use in a fire service application.
Please provide an item by item response.
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
,
' ¢ ' R an l I ; 1 t L
onal in do please attach }
submitting revised drawings, or:additi" forma , ' ( copy. of the ;
When submi
g g �
enclosed City of Tigard, p
' ty ,Letter of Tran smittal The letter of transmittal assists the ,City of
Tigard in tracking and processing the documents ,
Respectful y {' s
al Henze!, ,,
Sen Plans Examiner
•
•
Hornet, LLC OF TI . 4' `.
Gale Nelson
PO B s9 OREGON
Aurora, OR 97002
RE: HORNEL BUILDING — SHE REVIEW
Project Information
Site Permit: SIT2005- 00030 Construction Type: V - B
Tenant Name: Hornel Building Occupancy Type: B/S 1
Address: 14775 SW 74 Ave Occupant Load: NA
Area: 6,656 sq ft Stories: 2
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC)
2004 edition; and the Tualatin Valley Fire & Rescue Fire & Life Safety Requirements for Fire
Department Access and Water Supplies (Based on the 2004 Oregon Fire Code). The following
information is required prior to the issuance of a Site Permit:
NOTE: It has come to my attention that the building under review is larger than what was
approved through the City of Tigard planning department per case number SDR2000- 00023.
Therefore, Hornell LLC needs to contact Gary Pagenstecher, in the planning department to
resolve this issue. So3. NNE, a '/3 y .
1. Do to location on property at the North side; a 2 hour rated wall will be required. Provide
information showing building distance to property line to determine opening protection
requirements. Is a parapet wall required? 1/25/06 This is ok, shown on building plan.
3. Complete the enclosed permit application clarifying the Excavation, Grading and Fill
volumes. Not received 1/25/06
4. Complete the enclosed "TVF &R FIRE FLOW and HYDRANT WORKSHEET ". The
allowable area permitted and the number of hydrants required will be based on the
worksheet. Not received 1/25/06
5. Underground Fire Fighting Water Supply. Provide a bigger view and with more detail of
the thrust blocking details including cut sheets and installation instructions for any
mechanical joint connections. Provide supply pipe burial depth, piping sizes and materials,
valve equipment cut sheets, vault details, equipment in vaults, details for hydrants and Fire
Department Connection (FDC) location that are necessary for the installation of the fire
service. All valves shall be listed for use in a fire service application. Not received 1/25/06
NOTE: There is no record of any permits or inspection on the underground fire
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
fighting ' water supply the letter received
rived 1/24/06 can not be ac
pp y accepted without proof of
those inspections. Therefore please submit the above information for review.
Please provide an item by item response.
When submitting revised drawings or additional information, please attach a copy of the
enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the.City of
Tigard in tracking and processing the documents.
Respect
al Henzel,
Senior Plans Examiner
Sitework Review
Sitework Permit Review
• Check for Fire Department Access. Section 503 & 508 Fire Code.
• Check for Underground Fire Lines. NFPA 24.
• Check for any Retaining Walls. Section 1806 & Chapter 16 Building Code.
• Check for Site Accessibility. Section 1103 & 1104 Building Code.
• Check for any special Soil conditions. Chapter 18 Building Code.
• Verify that the erosion control measures have been indicated.
• Check the building for location on property. Table 602 Building Code.
''
(Point out required rated exterior walls, opening protection, parapets etc...)
1G(�1C� (t)c . tO /mss"- w'
Plumbing Site Utilities Review , 0,
• Check Potable Water supply for method, size and material. ,�
• Check Storm Drainage piping for method, slope, size & material.
• Check Sanitary Sewer piping method, slope, size & material.
��� GYM c; I I /' -e sZe
j 1 x.5 S 6-r(/ rc-S SV'e
(( O ( _lb
"1
f 1\
LASERFICFIE
January 26, 2006
Gale Nelson
PO Box 159
Aurora, OR 97002 FILE copy:
RE: Hornell Building Plumbing Plan Review
Project Information:
Plumbing Permit: PLM2005 -00692
Tenant Name: Hornell Office Building
Address: 14775 SW 74 Ave., Tigard, OR 97223
Occupancy Type: B
The plan review was performed under the State of Oregon Plumbing Specialty Code (OPSC)
2005 Edition. The following information is required prior to the issuance of a Plumbing
Permit.
1. Make application to the Building Official for use of C -900 piping for the sanitary sewer
line. C -900 is listed as water distribution piping and must be approved as an alternative
method and material per OSPSC Sections 715.1 and 301.2.
2. Make application to the Building Official for installation of a building sewer at less than 1 /4
inch per foot slope per OSPSC Sections 718.1 and 301.2.
American with Disabilities Act (ADA): It shall be the responsibility of the Architect,
Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA
requirements for the installation.
When submitting revised drawings or additional information, please attach a copy of the
enclosed City of Tigard Letter of Transmittal. The letter of transmittal assists the City of
Tigard in tracking and processing the documents.
Respectfully,
Mike Sheehan
Senior Plumbing Inspector