Report ,��rom: 12/03/2009 11:13 #835 P.0031003 Northwest Testing, Inc. 457 2 L�* — 00 /.5� -- A Division of Northwest Geotech, Inc. 9120.SW Pioneer Court, Suite 13 • Wilsonville, Oregon 97070 503/682 -1880 FAX 503/682 -2753 December 3, 2009 Project No. 2249.1.1 City of Tigard Building Division 13125 SW Hall Boulevard Tigard, Oregon 97223 Attention: Mr. Rick Bolen Subject: Final Summary Report of Construction Monitoring and Special Inspection Saier Residence 13911 SW Hillshire Drive Tigard, Oregon Permit No. MST2008 -00155 Dear Sir or Madam: As requested, Northwest Testing, Inc., (NTI) has provided construction monitoring /special inspection of the Saier Residence. Inspections were provided on an on -call basis. Our construction monitoring services included the following activities: Proprietary Anchors • Material Verification • Adhesive Anchor Installation Inspection A complete record of our inspection reports have been forwarded to the project team throughout the course of this project. To the best of NTI's knowledge, based on our inspections, the structural aspects of the project have been constructed in substantial conformance with the approved drawings, specifications, applicable provisions of the State Building Code, and the inspection methodology and acceptance criteria established by the project designer(s). This opportunity to be of service is sincerely appreciated. Should you have any questions, please contact the undersigned. Respectfully submitted, NORTHWEST TESTING, INC. lxija Michael A. Ginsbach Construction Services Manager Copies: (1) Addressee (E -mail only) (1) Steve Gemmell, Gemmell Construction, LLC (E -mail only) (1) Ken Saier, Owner (E -mail only) 0ons 2249 -7S Final Reporl.dncDOK 1 ,ro: � 12/O3/20OS 11�13 #O35 P O02/003 � '` T�r6on Inc. '"~°"'""""^ '"°"'' A P�* f:," � ����p����� »/mwwmpe/o^, ummo • w./,w1via^o'"!innom:Tr ml/1)x. 16110 numxmu o/m EXPANSION/ADHESIVE ANCHOR INSPECTION REPORT PROJECT NO ou*Q11 PERMIT NO. meT2008e0155 PAGE OF 1 l PROJECT NAME PROJECT REPORT Kevin Saler Residence LOCATION Tigard, Oregon SEQUENCE NO. /+1 CLIENT OR GENERAL INSPECTION OWNER Kevin Saier CONTRACTOR Gemmel! Construction DATE 11/13/09 INSTALLATION STRUCTURE CONTRACTOR GommoUConstmoiion Basement Walls CLIENT OR OWI4ER -- ADDRESS 13911 SVVHi|ixhim Drive, Tigard, Oregon ANCHOR OPERATIONS �' ��eqvii"enie CC Evaluation Servtces Report NO NOTED: ESR-2508. ESR'1772 Anchor Type/Size NIA NO NOTED! % Threaded rods Adhesive Type N/A NO NOTED: Simpson Set XP, Simpson Set 22 Adhesive Expiration Date N/A NO NOTED: 01/10 Base Material N/A NO NOTED: Normal weight concrete Hole Diameter/DriIl Bit Diameter N/A NO NOTED. 1'' for |4^.}{'' for %"bar smbedmenVHoleDepth NO NOTED: See below Hu|aCondi(iun/C|oan/inexo NO NOTED: Blown, brushed, blown Abandoned Holes YES NO NOTED' Anohnr|nuxo|!o8nn/P|anement N/A NO NOTED: Per plan Temperature/Curing Roqmromenm N/A NO NOTED- O2~F.3O hour cure time Tightening Torque YES NO NOTED: Tunoioo/Pu||Teubng YES NO NOTED_ THE FOLLOWING WAS NOTED: NTI arrived nn'niva, as noquenmd. to monitor installation o/ and %" diameter threaded rods using Simpson SET XP and Simpson Set 22, 1. (11) Pieces %' x 14 long all-thread rods, designated DI with embedment 9½" into exterior basement walis (Simpson XP). 2. (4) Pieces 7/8" x 19%" long all rods, designated D2 with embedment of 15" minimum into interior load bearing wall (Simpson Set 22). 3. (8) Pieces Y"x 18 long all-thread rods with embedment 4 minimum into (4) column bases, (2) per column, west side of basement (Simpson Set 22) To the best of NTI's knowledge, the anchor placement was in general conformance with project plans, specifications, and ICC report wu.'xEGR'25O8 and E8R'1772. NTI informed Gemmell Construction personnel of alt observations. FIELD REPRESENTATIVE: Kalin Bradov REVIEWED BY: Michael A. Girtsbach CERTIFICATION NO OBOA No. 925 COPIES TO: Rick Bolen, City of Tigard — Building Division Kevin Saier, Owner Steve Gemmel!, Gemmell Construction REVISION(S) TO PREVIOUS DOCUMENT NOTED IN ITALICS Effective Date: 12/03/05 This document shall not be reproduced, except in full, without written approval of NGI/NTI