Loading...
Permit CI TY OF TIGARD BUILDING PERMIT PERMIT #: BUP2006 -00440 l i , DEVELOPMENT SERVICES DATE ISSUED: 9/27/2006 ` 13125 SW Hall Blvd., Tigard, OR 97223 503 - 639 -4171 PARCEL: 2S 110AB -00200 SITE ADDRESS: 14297 SW PACIFIC HWY ZONING: C - SUBDIVISION: CANTERBURY SQUARE LOT: 1 - JURISDICTION: TIG Project Description: Upgrade fire supression system for Type I hood. REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: FPS FIRST: sf N: S: E: W: TYPE OF USE: COM SECOND: sf PROJECT OPENINGS? TYPE OF CONST: 5N : sf N: S: E: W: OCCUPANCY GRP: B TOTAL AREA: 0 sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: BASEMENT: sf AREA SEP. RATED: STOR: HT: ft GARAGE: sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: SMOK DET: DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : HNDICP ACC: BEDRMS: BATHS: IMP SURFACE: PRO CORR: PARKING: VALUE: $ 1,850.00 Owner: Contractor: KOLVE, G C FIRE EXTINGUISHER SERVICE CTR 14389 SW PACIFIC HWY 3460 SW 209TH AVE TIGARD, OR 97224 BEAVERTON, OR 97005 Phone: Contact #: FAX 503 - 626 - 9993 PRI 503 - 643 -3309 Reg #: LIC 69384 FEES Description Date Amount REQUIRED ITEMS AND REPORTS [BUILD] Permit Fee 9/13/2006 $62.50 [TAX] 8% State Surcha 9/13/2006 $5.00 [FLS] FLS Pin Rv 9/13/2006 $25.00 Total $92.50 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of these rules or direct questions to OUNC by calling 503 - 246 -6699 or 1- 800 - 332 -2344. / � � Issued By: � i/. . ,...d .1_ � _ � Permittee Signature: Call 503-639-4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Fire Pret‘ZfOle . S 'i CLL.'S * 0 c 1 Building Permit Application REC FoR OFFICE USE ONLY City of Tigard S P 1 3 200 S R e iv y p Permit No.: / ° 13125 SW Hall Blvd., Tigard, OR 97223 P lan Review t / f 1 " y �� '� v Phone: 503.639.4171 Fax: 503.598.1960 (` . ! -v c' r' ra,. -c• :3 r t � Date/B . - / fir_ , Other Permit: fi r I G n k 11 Inspection Line: 503.639 �� i � , DIVISION Date Re.. y c y: T 9 Juris: El See Page 2 for Internet: www.tigard- or.gov Notified/ �/ 7 Q e, / 1 t Supplemental Information L TYPE OF WORK REQUIRED DATA: 1- AND 2- FAMILY DWELLING ❑ New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all p . Addition /alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ I- and 2 -family dwelling V] Commercial /industrial Valuation: $ DI Accessory building ❑ Multi - family Number of bedrooms: El Master builder ❑ Other: Number of bathrooms: JOB SITE INFORMATION AND I LOCATION Total number of floors: Job site address: i4 i S P C. G L' . I , *T tt. 2.. New dwelling area: square feet City /State /ZIP: 7 / 9 cir . ) o ; CAcj ‘ :,► 11_2_ 4 Garage /carport area: square feet Suite/bldg. /apt. no.: Project name: Doff c) .:lv► ` /e. 014 del Giv ti Covered porch area: square feet Cross street /directions to job site: pa(1 (2t f, 11 -,,,/ y / e -,,,, e -,,,,.., *e' 1 ,, z ,,,, i. Deck area: square feet J Other structure area: square feet REQUIRED DATA: COMMERCIAL - USE CHECKLIST Subdivision: I Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. Valuation: $ 1 S 5 I Ai'1 rk1 / 1 )) FIe/. S kdpfh t4s//1 SNSkL✓I aN t1 ° .4tf 4 ;r•„ P t F U L ;0o Sri z,.et L, - _ - 1 `.., S.. _ Existing building area: square feet New building area: square feet ❑ PROPERTY OWNER ❑ TENANT Number of stories: Name: ti 0., Type of construction: Address: Occupancy groups: City /State /ZIP: Existing: Phone: ( y 9 $::,`,0C Fax: ( ) New: ® APPLICANT ❑ CONTACT PERSON NOTICE Business name: Ftrt e„1-,..,„ is I‘e.- Se V 1 ce, (eN --er All contractors and subcontractors are required to be Contact name: t q K M c V �C► R I L k IV t t, ho G S; licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: 34-60 3 ;;,) _2,01 4 . jurisdiction in which work is being performed. If the QQ / applicant is exempt from licensing, the following reasons City /State /ZIP: 1_)Zt ve✓hca ) d' y... �a)5 apply: Phone: (5 3) 356, - 9 -45 I "ax:: (56 3 5 tj 1 7 3 1 Z/ , • E -mail: CONTRACTOR BUILDING PERMIT FEES* Business name: (Please refer to fee schedule C Permit fee: ,(` i Address: J AT �' I („4-1 1— A. hC3 VC, ` State surcharge (8% of permit fee): (l OD — City /State /ZIP: ° FLS plan review (40% of permit fee): 0 J Phone: ( ) Fax: ( ) (Due upon application.) ot. CCB lic' b cj 3 8.t 1 v 1 (01 Total permit fees: Authorized signature: rL Amount received: 4 U This permit application expires if a permit is not obtained • Print name: 1 (riAH j LVC_,<, Date: 0 17/13/0 L, within 180 days after it has been accepted as complete. 1 * Fee methodology set by Tri- County Building Industry Service Board. 1:\ Building\Permits \FPS- PemitApp.doc 03/23/06 440 -4613T(11 /02/COM/WEB) A City of Tigard: Fire Protection Permit Checklist Page 2 - Supplemental Information Describe work to be done: 1.) 14 New 2.) Modification to sprinkler heads only ❑ Addition ❑ 1 -10 heads: No plan review required. ❑ Alteration ❑ 11+ heads: Plan review required. ❑ Repair Number of sprinkler heads: Additional description of work: e, P&L I (0 5 .6 Pc L -1 Type of System (Complete A, B, C or D as applicable): A.) Commercial Sprinkler ❑ Wet ❑ Dry Additional Standpipes Information: Hazard Group Density Design Area K. Factor Sprinkler Project Valuation: $ B.) Type I - Hood Fire Suppression System Hood Project Valuation:: ! $ 50 ° $ 5 (- C.) Fire Alarm Submittal shall Battery Calculations ❑ Yes include: Individual Component ❑ Yes Cut Sheets Fire Alarm Project Valuation: $ D.) Residential Sprinlder (Stand Alone System) Square Footage: Permit Fee: 0 to 2,000 $187.50 2,001 to 3,600 $232.50 3,601 to 7,200 $292.50 7,201 and greater $381.50 Sprinkler Project Square Footage: sq. ft. Fire Protection Permit Fees Project valuation subtotal (see A, B & C above): $ Permit fee based on project valuation (see fee schedule): $ Permit fee based on square footage (see D above): $ State Surcharge (8% of permit fee): $ FLS Plan Review (40% of permit fee): $ TOTAL: $ Plan review requires a completed application and 2 sets of plans at submittal. Plan review fees are required at submittal. "New" fire protection systems require that plans bear the original seal of an Oregon licensed fire suppression engineer, or NICET level "3" technicians. I: \ Building \Permits \FPS - PermitApp.doc 2 0 .. , . September 26, 2006 (7/0/ kin \" i V �' + I , +'` P CITY OF Tl OREGON Fire Extinguisher Service Center Rian McVae 3460 SW 209 Ave Beaverton, OR RE: FIRE SUPPRESSION SYSTEM FOR TYPE ONE HOOD Project Information Building Permit BUP2006-00440 Construction Type: 5 B Tenant Name: Don Juan Occupancy Type: B Address: 14297 SW Pacific Hwy. The plan review was performed under the State of Oregon Structural Specialty Code (OSSC), and 2004 Oregon Fire Code (OFC) amended by Tualatin Valley Fire & Rescue. The submitted plans are approved subject to the following. 1. The automatic fire suppression system shall be of a type recognized for protection of commercial cooking appliance and exhaust systems of the type and arrangement protected. Pre - engineered automatic dry- and wet - chemical fire suppression system shall be tested in accordance with UL 300. Automatic fire suppression systems, including pre- engineered and engineered dry- and wet chemical fire - suppression systems, shall be listed and labeled for specific use as protection for commercial cooking operations and shall be installed in accordance with this code, its listing and manufacturer's installation instructions. OFC 904.11 2. The actuation of the automatic fire suppression system shall automatically shut down the fuel or electrical power supply to the cooking appliances. The fuel and electrical power supply reset shall be manual. OFC 904.11.2 3. Each automatic fire suppression system shall have both automatic and manual actuation means. A manual actuation device shall be located at or near a means of egress from the cooking area, a minimum of 10 feet and a maximum of 20 feet from the kitchen exhaust system. The manual actuation device shall be located a minimum of 4 feet and a maximum of 5 feet above the floor. The manual actuation shall require a maximum force of 40 pounds and a maximum movement of 14 inches to actuate the fire suppression system. OSSC[F] 904.11 4. Automatic sprinkler systems protecting commercial -type cooking equipment shall be supplied from a separate, readily accessible, indicating -type control valve that is identified. OSSC [F]904.11.4 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 5. Sprinklers used for the protection of fryers shall be listed for that application and installed in accordance with their listing. OSSC [F]904.11.4.1 6. The automatic fire suppression system shall be acceptance - tested in accordance with OFC 904, and installation standard listed in section OMSC 509.3, and with the manufacturer's instructions. 7. The automatic fire suppression system shall be serviced at least every 6 months and after activation of the system. Inspection shall be by qualified individuals, and a certificate of inspection shall be forwarded to the fire code official upon completion. OFC 904.11.6.4 Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4:2 OSSC When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, al enzel, Senior Plans Examiner t. _ , Pyro -Chem e , ® f «; . o r ���� s KITCHEN 10.,tt 1 Kitchen Kn ht 11 w 1 ,� Pipe Volumes i R, , .� r, I 1 3 2006 o C o nvers ion Cha KNIGHT I I t Sip e r 44RR 1/4" = 20.5 ml per ft. c�r3/8'G F i b bjm tper ft. 1/2" = 59.8 ml per ft. 3/4" = 105 ml per ft. 1 st nozzle Total Pipe From 1st nozzle to last nozzle Cylinder Flow Total Pipe to last Maximum Pipe Length Maximum Pipe Length Size Pts Vol nozzle 1/4" 3/8" 1/2" 3/4" 1/4" 3/8" 1/2" 3/4" PCL 300 10 •1910 1125 93.17 ft 50.93 ft 31.94 ft 18.19 ft 54.88 ft 30.00 ft 18.81 ft 10.71 ft PCL 460 14 3400 3000 165.85 ft 90.67 ft 56.86 ft 32.38 ft 146.34 ft 80.00 ft 50.17 ft 28.57 ft PCL 460 15 2600 2000 126.83 ft 69.33 ft 43.48 ft 24.76 ft 97.56 ft 53.33 ft 33.44 ft 19.05 ft PCL 600 19 4215 1688 /side 205.61 ft 112.40 ft 70.48 ft 40.14 ft 82.34 ft 45.01 ft 28.23 ft 16.08 ft PCL 600 20 3465 1312.5 /side 169.02 ft 92.40 ft 57.94 ft 33.00 ft 64.02 ft 35.00 ft 21.95 ft 12.50 ft Pipe Pipe Size/m1 Minimum Pipe Volumes for a Fryer, Range, and Wok length/ft 1/4° 3/8° 1/2° 3/4" Cylinder Size Entire System At or before appliance 1 20.5 37.5 59.8 105 PCL 300 300 ml - 4 Flow Pts 239 ml - 2 Flow Pts 2 41 75 119.6 210 PCL 460 660 ml - 10 Flow Pts 180 ml - 2 Flow Pts 3 61.5 112.5 179.4 315 PCL 600 960 ml - 14 Flow Pts 120 ml - 2 Flow pts 4 82 150 239.2 420 5 102.5 187.5 299 525 6 123 225 358.8 630 7 143.5 262.5 418.6 735 8 164 300 478.4 840 9 184.5 _ 337.5 538.2 945 10 205 375 598 1050 11 225.5 412.5 657.8 1155 12 246 450 717.6 1260 13 266.5 487.5 777.4 1365 14 287 525 - 837.2 1470 15 307.5 562.5 897 1575 16 328 600 956.8 1680 17 348.5 637.5 1016.6 1785 18 369 675 1076.4 1890 19 389.5 712.5 1136.2 1995 20 410 750 1196 2100 General Rules: 1. Measurements taken from fittings centerline (All SCH. 40 Pipe). 2. Maximum difference in elevation from valve outlet to any nozzle is 10'. 3. Largest diameter pipe must be used first and decrease in size as installation moves away from the tank. 4. No traps in the piping. 5. Two elbows are allowed in place of a swivel. Elbows used as a swivel do not have to be subtracted from the total allowed. 6. Maximum of 25 elbows. 7. Maximum of 5 elbows between nozzle and preceding tee. 8. Maximum flows for 1/4" pipe = 6 flows. 9. Max. volume allowed for 1/4" pipe from tee to noz. is 410 ml. (20 ft). Additional rules for PCL 600: 1. Split piping must be used with a maximum of 14 flows on a side. 2. No nozzles before the split. 3. Minimum 1/2" pipe must be used to the first split. CITY OF TIGARD BUILDING DIVISION PERMIT #: SUP2006-00440 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 9/27/2006 Phone: (503) 639-4171 10,0 414111 1 " Inspection Requests (24 Hrs.): (503) 639-4175 - LL INSPECTION WORKSHEET FOR DATE: 1/12/2007 TIME: 7:04AM PAGE: 29 SITE ADDRESS: 14297 SIN PACIFIC HWY CLASS OF WORK: SUBDIVISION: CANTERBURY SQUARE LOT #: I.3 TYPE OF USE: PROJECT NAME: DON JUAN DESCRIPTION: Upgrade fire supression system for Type hood. OWNER: KOLVE, G C, PHONE #: CONTRACTOR: FIRE EXTINGUISHER SERVICE CTR PHONE #: 503-643-3309 • Inspection Request Scheduled For: Date: 1/120007 Pour Time: Code # Inspection Description Confirm # Contact # Message 299 Final inspection 042065-01 1. 503-356-9445 () N Corrections/Comments/Instructions: k tiV c • . . • (4, I 4 Et PASS r LIIl PARTIAL APPROVAL El CANCEL El NO ACCESS 1 M FAIL , ALL FOR INSPECTION ADDITIONAL FEES ASSESSED Inspector: DatArA/\( ( 1 1 10 e: t 67 Phone #: (503) 718-