Loading...
Report 01/06/09 TUE 15:34 FAX 503 670 9147 CARLSON TESTING 15002 Akci. 01115.. Sakor Office Bend Carlson Testing, Inc. 843D574XmrJ�f IAfD Ruder 4, 1Jg 65073 9 7 7 02 Otlrl 1kI llama OR 97223 mrrm OR 979 Bend Ux Y770Z BMW M3)6443460 Air. ac: 503) 540.1251 Ilgae; 6JU 550 -4155 Fit. 6031 61114-099J F 503158 -) 5+' 14u 6417 5304163 Construction Materials Testing & Inspection Ce p24.05 -(xxi Special Inspection FINAL SUMMARY LETTER January 6, 2009 T0806977 City of Tigard 13125 SW Hall Blvd Tigard, OR 97223 -8199 Attn: Building Department Re: Tualatin Valley Fire & Rescue -- Fire Station #50 12617 SW Walnut Street — Tigard, OR Permit# BUP2008 -00022 Dear Sir or Madam: This is to certify that in accordance with Section 1704.1.2 of the International Building Code, we have performed special inspection of the following item(s) per our inspection reports only: Reinforced Concrete Installation of Adhesive Anchors Structural Masonry Structural Welding- Shop & Reid All inspections and tests were performed and reported according to the requirements of Project Documents and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's design changes, approvals and verbal instructions. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without • rior authorization from this office. If there ar. =ny further questions_ regarding this matter, please do not hesitate to contact this office. Respec y submitte! CARLS TEST , INC. , m , - F. Hietpas P • - t Manager J ks Tualatin Valley Fire & Rescue — Gary Wells Lewis & Van Vleet Inc — Lance Cerny Peck Smiley Ettlin Architects -- Jeff Bringenberg First Cascade Corporation — Michael Krecklow First Cascade Corporation — Matt Hubei 01/06/09 TUE 15:34 FAX 503 670 9147 CARLSON TESTING V1001 CARLSON TESTING, INC. Phone: 503 - 684-3460 /Fax 503 -684 -0954 PO Box 23814 Tigard, OR 97223 FAX TRANSMITTAL To: City of Tigard Attn: Building Department Fax: 503/624 -3681 From: Carlson Testing, Inc. — Karen Shepherd Date: January 6, 2009 Re: FINAL SUMMARY LETTER Total Pages: 2 CJ This is the final summary letter for: Project: Tualatin Valley Fire & Rescue — Fire Station #50 Permit* BUP2008 -00022 Please call if you have any questions. 503 /419 -4527, Thank You, Karen Shepherd Administrative Assistant