Loading...
Report Bend Office (541) 330 -9155 ss�� pp Geotechnical Office (503) 601 -8250 Cards ®n Testing Inc. Eugene Office (541) 345 -0289 Salem Office (503) 589 -1252 Tigard Office Office (503) 684 -3460 6 p -J • OCDO 6 `4 REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31/ C172 /C192/C39/C1064/C231/C143/C1231 Date Molded: 02/11/2009 Job Number: T0807926.A Permit #: BUP2008 -00004 Client: PFAFFLE OFFICE LLC & PCCC LLC — ROGER STALICK Project: PACIFIC CROSSROADS CORPORATE CENTER — BUILDING A Address: 8020 SW PFAFFLE STREET TIGARD OR Jurisdiction: TIGARD Contractor: COMMERCIAL CONTRACTORS INC — ERIC MONEY Subcontractor: SHARP Cast By: J. BLACK Concrete Supplier: GLACIER NORTHWEST Truck #: 7355 Load #: 1 Ticket #: 208257 Weather: OVERCAST Test Time:. 11:05 Air Temp. at Sampling Time: 45 Cylinders were cast for the following locations: SAME AS BELOW Total Concrete Placement Location: CURB AND GUTTER ON SOUTH SIDE OF PFAFFLE ST ADJECENT BUILDING A —B FROM 15' TO 150' WEST OF EAST END REPLACES PORTION OF CURB AND GUTTER PLACED ON 1/20/09 Strength Requirement: 3000 psi f c@ 28 Days Slump: 2.750" % Air: 5.80% Mix Number: 08805 (3.3K) Conc. Temp: 56 Cement Type: I /II Max Agg: 3/4 Admix/Amt: 80 OZ /YD CALCIUM CHLORIDE 7.5 Cubic Yards: Register Number: 0089678 Lab Location: TIGARD Set Test @ Date Test Total Area Unit Type Of Cap Tested No. Days Rec'd Date Load PSI Fracture Type By I 7 02/12/2009 02/18/2009 46385 12.60 3680 2 PAD 60 BR 28 02/12/2009 03/11/2009 61180 12.62 4850 2 PAD 60 WR 28 02/12/2009 03/11/2009 60993 12.62 4830 3 PAD 60 WR 28 02/12/2009 03/11/2009 65264 12.62 5170 2 PAD 60 WR ❑ Distribute attachments. Average f @ 28 days - 4950 Please see reverse side for additional information. Job Number: T0807926.A Register Number: 0 089678 Date Molded: 02/11/2009 Project: PACIFIC CROSSROADS CORPORATE CENTER — BUILDING A < 1 in. [25 mm] .)\\. l�I Type 1 Type 2 Type 3 Reasonable well- formed Well- Formed cone on one Columnar vertical cracking cones on both ends. less end, vertical cracks running through both ends, no than 1 in. [25 mm] of through caps, no well - defined well - formed cones cracking through caps cone on other end rr Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly end of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: PFAFFLE OFFICE LLC & PCCC LLC - ROGER STALICK STALICKCO @COMCAST.NET TO: CITY OF TIGARD BUILDING DIVISION AFGHAN ASSOCIATES INC - CRAIG HARRIS CRAIGH @AAIENG.COM MILDREN DESIGN GROUP - BETTY SHEPPARD BETTY @MDGPC.COM COMMERCIAL CONTRACTORS INC - ERIC MONEY ERIC @CCIGC.COM Project Manager: STEVEN W. LEACH Reviewed By: Ty Toller On 03/13/2009 Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. Under all circumstances, the information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document.