Loading...
Report Bend Office (541) 330 -9155 Geotechnical Office (503) 601 -8250 Inc. Eugene Office (541) 345 -0289 Carlson Testing Salem Office (503) 589 -1252 Tigard Office (503) 684 -3460 647 ea..) 60 —' REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31/ C172 /C192/C39/C1064/C231/C143/C1231 Date Molded: 04/23/2010 Date Received: 04/26/2010 Job Number: T1001923. Permit #: BUP2009 -00208 Client: TUALATIN VALLEY FIRE & RESCUE - SIOBHAN KIRK Project: &R - COMMAND & BUSINESS OPERATIONS CENTER (CBOC) Address: 11945 SW 70TH AVENUE TIGARD OR Jurisdiction: TIGARD Contractor: HOWARD S WRIGHT CONSTRUCTORS - JASON CHUPP Subcontractor: Cast By: K. THRALL Concrete Supplier: KNIFE RIVER (METRO OPERATIONS) - QUALITY CONTROL Truck #: 40395 Load #: 1 Ticket #: 3294617 Weather: CLOUDY Test Time: 8:30 Air Temp. at Sampling Time: 43 Cylinders were cast for the following locations: SAME AS BELOW Total Concrete Placement Location: ROOF TOP MECHANICAL PAD WALLS, 2ND & 3RD FLOOR SLAB INFILLS AT 5 /B.7 -C AND B.5/7 Strength Requirement: 4000 psi f c@ 28 Days Slump: 5.000" % Air: 1.60 %- Mix Number: 4 0 PGH2 M0 Conc. Temp: 66 Cement Type: VII Max Agg: 3 / 4 " Admix/Amt: POLYHEED : 120 OZ ; HOT WATER Cubic Yards: 4 Register Number: 0094793 Lab Location: TIGARD Set Test @ Test Total Avg. Area Unit Type Of Cap Tested No. Days Date Load Diameter PSI Fracture Type By I 7 04/30/2010 60731 4.01 12.62 4810 3 PAD 60 BAH 28 05/21/2010 84513 4.01 12.62 6700 3 PAD 60 BAH 28 05/21/2010 83768 4.01 12.62 6640 3 PAD 60 BAH 28 05/21/2010 84120 4.01 12.62 6670 2 PAD 60 BAH Distribute attachments. Average f c@ 28 days 6670 Please see reverse side for additional information. Job Number: T1001923 . Register Number: 0094793 Date Molded: 04/23/2010 Project: TVF &R - COMMAND & BUSINESS OPERATIONS CENTER (CBOC) <1 in. [25 mm] \ / )%. / \ .0 , Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25 mtn] of through caps, no well- defined well - formed cones cracking through caps cone on other end r \ / Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur commonly rnd of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - SIOBHAN KIRK TO: CITY OF TIGARD BUILDING DIVISION KPFF - IAN EIKANAS IAN.EIKANAS @KPFF.COM PSE ARCHITECTS - NATHAN JUNKERT NATHAN @PSEARCHS.COM HOWARD S WRIGHT CONSTRUCTORS - JASON CHUPP CHUPPJ @HSWC.COM TUALATIN VALLEY FIRE & RESCUE - GREG PERRY GREG.PERRY @TVFR.COM TUALATIN VALLEY FIRE & RESCUE - NANCY COLLINS NANCY.COLLINS @TVFR.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toiler On 05/24/2010 Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. Under all circumstances, the information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. Bend Office (541) 330 -9155 Geotechnical Office (503) 601 -8250 Eugene Office (541) 345 -0289 Carlson Testing, Inc. Salem Office (503) 589 -1252 Tigard Office (503) 684 -3460 c3 "2_0 r —.- REPORT OF 4 X 8 CONCRETE TEST SPECIMENS Test Methods: ASTM C31/ C172 /C192/C39/C1064/C231/C143/C1231 Date Molded: 04/19/2010 Date Received: 04/20/2010 Job Number: T1001923 . Permit #: BUP2009 -00208 Client: TUALATIN VALLEY FIRE & RESCUE - SIOBHAN KIRK Project: &R - COMMAND & BUSINESS OPERATIONS CENTER (CBOC) Address: 11945 SW 70TH AVENUE TIGARD OR Jurisdiction: TIGARD Contractor: HOWARD S WRIGHT CONSTRUCTORS - JASON CHUPP Subcontractor: Cast By: M . LARSON Concrete Supplier: KNIFE RIVER (METRO OPERATIONS) - QUALITY CONTROL Truck #: 329 Load #: 1 Ticket #: 3294515 Weather: CLOUDY /WARM Test Time: 7 : 55 AM Air Temp. at Sampling Time: 52 Cylinders were cast for the following locations: ROOF MECHANICAL SLAB Total Concrete Placement Location: ROOF MECHANICAL SLAB Strength Requirement: 4000 psi f c@ 28 Days Slump: 5.000" % Air: 2.20% Mix Number: 40PGH2M0 Conc. Temp: 67 Cement Type: I /11 Max Agg: 3/4" Admix/Amt: POLYHEED Cubic Yards: 4 " Register Number: 0094732 Lab Location: TIGARD Set Test @ Test Total Avg. Area Unit Type Of Cap Tested No. Days Date Load Diameter PSI Fracture Type By I 7 04/26/2010 54163 4.02 12.69 4270 1 PAD 60 JT 28 05/17/2010 72378 4.01 12.62 5740 2 PAD 60 BAH 28 05/17/2010 70716 4.01 12.62 5600 2 PAD 60 BAH 28 05/17/2010 68566 4.01 12.62 5430 2 PAD 60 BAR n Distribute attachments. Average f c@ 28 days 5590 Please see reverse side for additional information. Job Number: T1001923 . Register Number: 0094732 Date Molded: 04/19/2010 Project: TVF &R - COMMAND & BUSINESS OPERATIONS CENTER (CBOC) < 1 in. [25 mm] .) i� S '� 1 ( '11, \ r 5 555 5 ,, \ ,r \ Type 1 Type 2 Type 3 Reasonable well - formed Well- Formed cone on one Columnar vertical cracking cones on both ends, less end, vertical cracks running through both ends, no than 1 in. [25.mm] of through caps, no well- defined well - formed cones cracking through caps cone on other end \ - Type 4 Type 5 Type 6 Diagonal fracture with Side fractures at top or Similar to Type 5 but no cracking through bottom (occur conunonly ,tid of cylinder is pointed ends; tap with hammer to with unbonded caps) distinguish from Type 1 Asterisked ( *) average unit PSI test results did not meet listed acceptance criteria. Remarks: TUALATIN VALLEY FIRE & RESCUE - SIOBHAN KIRK TO: CITY OF TIGARD BUILDING DIVISION KPFF - IAN EIKANAS IAN.EIKANAS @KPFF.COM PSE ARCHITECTS - NATHAN JUNKERT NATHAN @PSEARCHS.COM HOWARD S WRIGHT CONSTRUCTORS - JASON CHUPP CHUPPJ @HSWC.COM TUALATIN VALLEY FIRE & RESCUE - GREG PERRY GREG.PERRY @TVFR.COM TUALATIN VALLEY FIRE & RESCUE - NANCY COLLINS NANCY.COLLINS @TVFR.COM Project Manager: JAMES F. HIETPAS Reviewed By: Ty Toller On 05/19/2010 Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. Under all circumstances, the information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document.