Report a 000 VI
Construction Inspection & Related Tests
L aarlson 'Testing Inc. Geotechnical Consulting
P.O. Box 23814
`` Special Inspection Tigard, Oregon 97281
Phone (503) 684 -3460
FINAL SUMMARY REPORT FAX (503) 684-0954
October 4, 1996
#96 -5446
Permit No. BUP96- 0089/BUP96 -0283
City of Tigard
13125 SW Hall Blvd.
Tigard, OR 97223
Re: Tigard Center
16920 S.W. 72nd
Tigard, Oregon
Gentlemen:
This is to certify that the items listed below are in accordance
with Section 1701.3 of the Uniform Building Code. We have
performed random /periodic special inspection at the contractor's
request of the following items per our inspection reports only:
Reinforced Concrete
Structural Masonry
Compaction Testing /Engineered Grading
Epoxy Dowell Installation
All inspections and tests were performed and reported according to
the requirements of UBC Section 1701.3 and, to the best of our
knowledge, the work was in conformance with the approved plans and
specifications, approved change orders and applicable workmanship
provisions of the Uniform Building Code and Standards, as well as
the structural engineer's design changes and approvals.
Our reports pertain to the material tested /inspected only.
Information contained herein is not to be reproduced, except in
full, without prior authorization from this office.
If there are any further questions regarding this matter, please do
not hesitate to contact this office.
Respectfully subitit d,
CARLS yTES ING, NC.
/)L.r •
Douglas W. Leach
President
mbh
cc: Bingham Construction Company
MTR Architects - Ed Craker
• 01719/98 MON 08:42 FAX 503 684 0954 CARLSON TESTING Cj002
Construc to 1 pection & Related Tests
Carlson Testing, Into Geotechnical Consulting
P.O. Box 23814
Special Inspection Tigard, Oregon 97281
Phone (503) 684 -3460
FINAL SUMMARY REPORT FAX (503) 684 0954
October 4, 1996
#96 -5446
Permit No. BUP96- 0089/BUP96 -0283
City of Tigard
13125 SW Hall Blvd.
Tigard, OR 97223
Re: Tigard Center
16920 S.W. 72nd
Tigard, Oregon
•
Gentlemen:
This is to certify that the items listed below are in accordance
with Section 1701.3 of the Uniform Building Code. We have
performed random /periodic special inspection at the contractor's
request of the following items per our inspection reports only:
Reinforced Concrete'
Structural Masonry
Compaction Testing /Engineered Grading
Epoxy Dowell Installation
All inspections and tests were performed and reported according to
the requirements of UBC Section 1701.3 and, to the best of our
knowledge, the work was in conformance with the approved plans and
specifications, approved change orders and applicable workmanship
provisions of the Uniform Building Code and Standards, as well as
the structural engineer's design changes and approvals.
Our reports pertain to the material tested /inspected only.
Information contained herein is not to be reproduced, except in
full, without prior authorization from this office.
If there are any further questions regarding this matter, please do
not hesitate to contact this office.
Respectfully s1.914 d,
!/
C _ 1INESTIr NC.
Douglas W. Leach
Pres
L'
mbh
cc: Bingham Construction Company
MTR Architects - Ed Craker