Specifications pau1 = - 2-
City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 ' .
ill
- 'tt
February 16, 2007 No °" ' ;
TI -. , • D elta Fire, Incorporated ,
14795 Sw 72 " Avenue
Portland, OR 97224
• RE: JOHNSTONE SUPPLY
:: Project Information
Building Permit: BUP2007 -00082 Construction Type: 2B
Tenant Name: Johnstone Supply Occupancy Type: B /S2
Address: 16650 72 Avenue Occupant Load: NA
Area: 80,500 Sq Ft Stories: 1
Hazard: High Piled Storage
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC)
2004 edition; National Fire Protection Association, Standard 13 (NFPA 13)2002 edition and the
State of Oregon Fire Code (OFC) 2004 edition. The submitted plans are approved subject to the
following.
HYDROSTATIC TESTING
All piping and attached appurtenances shall be hydrostatically tested at 200 psi and shall
maintain that pressure without loss for 2 hours. The test pressure shall be read from a gauge
located at the low elevation point of the system or portion being tested. Section10.10.2.2.1 &
Section 10.10.2.2.3 NFPA 13.
GENERAL
1. A key box shall be installed in a location approved by the Fire Chief. The key box shall
be of an approved type and shall contain keys to gain necessary access as required by the
fire code official. Section 506.1 OFC. Please contact Tualatin Valley Fire & Rescue for
key box information at 503 - 612 -7010
2. A supply of spare sprinklers (never less than 6) shall be maintained on the premises so
that any sprinklers that have operated or been damaged in any way can be promptly
replaced. These sprinklers shall correspond to the types and temperature ratings of the
sprinklers on the property. Sections 6.2.9.1 & 6.2.9.2 NFPA 13.
3. The spare sprinklers shall be kept in a cabinet located where temperatures will not
exceed 100 degrees "F" at any time. A special sprinkler wrench shall be provided and
kept in the sprinkler cabinet to be used in the removal and installation of sprinklers.
Sections 6.2.9.3 & 6.2.9.6 NFPA 13.
Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772
4. The clearance between the deflector and the top of storage shall be 18 inches or greater.
Section 8.6.6.1 NFPA 13. The distance shall be increased to 36 inches for Large Drop
sprinkler heads. Section 8.11.6 NFPA 13
5. Sprinklers shall be located a minimum of 4 inches from walls and spaced not less than 6
feet on center. Sections 8.6.3.3 & 8.6.3.4.1 NFPA 13.
6. Clearances shall be provided around all piping extending through platforms,
foundations, walls and floors. The diameter of the hole shall be 2 inches larger than the
penetrating pipe for pipe sizes 1 inch through 3 '/z inches. The diameter of the hole shall
be 4 inches larger than the penetrating pipe for pipe sizes 4 inches and larger. Sections
9.3.4.1 & 9.3.4.2 NFPA 13.
7. All valves controlling the water supply for automatic sprinlder systems and all water flow
monitoring devices shall be electrically monitored when the system serves more than 20
heads. Section 903.4 OFC
8. An approved audible sprinkler flow alarm shall be provided on the exterior of the
building in an approved location. Such sprinkler water -flow devices shall be activated by
water flow equivalent to the flow of a single sprinlder of the smallest orifice size installed
in the system. Section 903.4.2 OFC
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be
maintained on the jobsite. The plans shall be available to the Building Division inspectors
throughout all phases of construction. 106.4.2 OSSC
When submitting revised drawings or additional information, please attach a copy of the
enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of
Tigard in tracking and processing the documents.
Respectfully,
„7 7: 7 / -- .7
.Brian lalock,
Building Official
�]
6
14795 S.W. 72ND AVENUE
PORTLAND, OR 97224
503 - 620 -4020 • FAX 503 - 620 -1058
"�r ® CCB# 64174
FE3 0 9 2007
Oregon Business T
Buildin g 12
Johnstone Supply
DATA SUBMITTAL
FOR
FIRE PROTECTION SYSTEM
DELTA FIRE, INC.
February 8, 2007
Matt Staley
07 -3744
Oregon Business Park Building 12 — Johnstone Supply
February 8, 2007
Page 2 of 2
TABLE OF CONTENTS
Pipe & Fittings
Black DynaFlow
Black DynaThread
CIS Fittings
Victaulic Firelock Couplings Fig. #005
Victaulic Couplings Fig. #75
Victaulic Mechanical Tee Fig. #920/921
Hangers
Tolco Pipe Rings Fig. #2
Sammy Super Screws Fig. #GST20
Sammy Sidewinder Screws Fig. #SWG20
Sprinkler Heads
Reliable Model Fl 'h" 286 Degree Upright
Reliable Model F1 'h" 155 Degree Horizontal Side Wall
Reliable Model F1 ' /s" 155 Degree Pendent
Miscellaneous
Reliable Oops Rings
FIRE PROTECTION CONTRACTORS
With ABF
)With
Dyna-FIow®
. High Strength Steel Pipe
The original high strength lightwall sprinkler pipe with hydraulics superior to Schedule -10.
Dyna -Flow pipe is the `original" high- Specifications
strength lightwall sprinkler pipe. Dyna-
Flow has outstanding hydraulic NPS Nominal I.D. Wt. Wt. (H20 Filled) Pas/ Wt/Litt (21') Wt/Lift (24') WI/Lift (25')
capabilities and is recognized as the In; mm In; mm Lbs/Ft; Kg /m Lbs/Ft ;; Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg
most popular altemative to Schedule -10 1' 1.191 0.830 1.31 91 1,586 1,812 1,888
pipe. Lightweight, easy to cut and easy 25 30.3 1.2 1.95 91 719 822 856
- to handle for installation. Dyna -Flow is a 1' /e° 1.536 1.059 1.87 61 1,356 1,550 1,615
valuable addition to any fire protection 32 39.0 1.6 2.78 61 615 703 733
system. 11/2' 1.728 1.667 2.71 61 2,135 2,440 2,542
Superior Hydraulics 40 43.9 2.5 4.03 61 968 1107 1153
2° 2.203 2.104 3.79 37 1,634 1,868 1,946
With an inside diameter of up to 11% 50 56.0 3.1 5.64 37 741 847 883
larger than Schedule -40 and up to 7% 21/4' 2.703 2.564 5.10 30 1,615 1,846 1,923
larger than Schedule -10, Dyna -Flow 65 68.7 3.8 7.59 30 733 837 872
pipe hydraulics are exceptional. Larger 3° 3.314 3.387 7.18 19 1,351 1,544 1,608
I.D.s enable Dyna -Flow, and related 80 84.2 5.0 10.69 19 613 700 729
components, to be down -sized within the 4' 4.310 4.473 10.86 19 1,784 2,039 2,124
system, thus increasing the potential for 90 109.5 6.7 16.16 19 809 925 963
job cost savings. For complete Hazen -
Williams charts, refer to "Dyna -Flow
Hydraulic Data Tables."
Coatings & Fabrication Specifications & Approvals Additional Benefits
Dyna -Flow products are coated with Dyna -Flow /Super Flo pipe is manufac- • Lightweight and easy to install,
an environmentally approved and tured to meet ASTM A -795 Type E, resulting in more efficient use of your
specially formulated modified - acrylic or Grade A and is in compliance with freight and labor dollars.
water -based coating. This durable coating NFPA -13 and NFPA -14. All sizes of
is paintable. The black coating acts as Dyna Flow /Super Flo are UL Listed, FM • Provides stability needed to comply
an excellent primer and is resistant to Approved and ULC Listed. with standard hanger spacing
(15 ft O.C.) per NFPA.
weathering and U.V. degradation from
outdoor storage. (1) • 07. • Available in Standard lengths for your
Metallurgical properties provide excellent Listed Approved Listed convenience, or can be ordered in
fabrication characteristics for end prep yn p custom lengths upon approval.
D a- Flow /Suer Flo is UL/ULC Listed
finishes, welding and roll grooving. for use with roll grooved, plain -end • Fast cutting and welding, as well as
There is no special process or equipment couplings, and welded joints for wet, dry, easy roll grooving and end preparation.
needed for fabrication and installation. preaction and deluge systems. It is FM
• Available in Factory roll grooved form
The internal surface of all black Allied Approved for roll grooved, plain -end, and for quicker shop turnaround.
Tube & Conduit Fire Sprinkler pipe welded joints for wet systems. Refer to
products up to 4.5000" in diameter is appropriate documentation for up -to -date • Clean, durable mill coating provides
coated with our new Antibacterial listing and approval information. Dyna- longer "shelf life" and acts as an
Formula, "ABF ". In scientific laboratory Flow /Super Flo is now available "hot- excellent primer for custom paint
test, ABS proved to have superior dip" galvanized and has been specifically applications.
resistance to microbial colonization of approved by FM for dry systems uses.
. pipe walls, thereby delaying or possibly
preventing the onset of Microbiologically
Influenced corrosion (MIC) when the
First Sprinkler System is first installed.
,
*t�CO /Flow Control 16100 S. Lathrop • Harvey, IL 60426 Customer Service:
aIllpd 11350 Norcom Rd. •Philadelphia, PA 19154 (800) 882 -5543
TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708 -339 -1806
S2 -3
;ay — —
l
h!1 k
• q'�i �� ��t �A A D IA it it i. .4 . ...,.. , • ,
2
u + '° . . DYNA DYN
t_. TN n, Tb
m
. ..
a` JYN.A DYNI DYNA DYNA DYNA
•' Tb(fl$A. O- TN4i'fi A- .. ' TI'I . , A • l a o .') f ti 41 t:A0
1111111 • A" DYNA DYNA' D YNA DYNA 0
:CI , * • . . .. ...„-- - . dt%
IM ( 1'il �.1 N
DYNA DYNA' DYNA DYNA DYNA l'Jli i� �'IU
TA AAA, - _ T 1 . . •.• - -. r.. _
: .nwwu..<r
i i r DYNA D YNA; D YNA ��,
v -
0
8 11
00 0
C
as
o�
Dyna-Thread®
Full Line Sch -40 Replacement
Dyna - Thread' offers the life expectancy of Sch40 with superior hydraulics and greater value.
N
Dyna - Thread sprinlder pipe represents an engineering advancement for the sprinlder pipe industry. It combines the safety
and longevity of traditional Sch -40 pipe with quality and superior hydraulic advantages.
Comparison to Schedule 40 Comparison to L.W.T. Pipes
• Dyna- Thread's inside diameter is up • With its increased strength and lighter • More wall thickness at the thread
to 3.6% larger than Sch-40 giving it weight, Dyna- Thread reduces (CRR =1.00) gives Dyna- Thread
superior hydraulics. And, when used installation fatigue and is ideal for better life expectancy than lightwall
in combination with Dyna -Flow pipe, retro -fit applications. threadable pipe joints.
down sizing often occurs.
Corrosion Resistance Ratio (CRR) is a • Unlike lightwall threadable pipe,
• Dyna - Thread is fully listed and UL (Underwriters Laboratory) term for Dyna - Thread has no thread gauge
approved by UL, ULC, and FM for the estimated life expectancy of a pipe warning.
fire sprinkler applications. joint. This is based on the calculated
•
wall thickness at the base of the first Dyna- Thread is approved for
• The life expectancy of Dyna- Thread exposed thread, assumed to be the standard hanger spacing (15 ft.
and Sch-40 are equal based on the O.C.), can be used as earthquake
calculated wall thicknesses per UL.
weakest point of the pipe length. Dyne- sway bracing, and is safe to use as
Thread and Sch-40 have the same drops.
• The consistent quality of steel used to calculated wall thicknesses at this point
make Dyna - Thread facilitates smooth and are both assigned the same CRR of • Dyna- Thread is safer to weld on.
threading and lower maintenance 1.00.
costs. • Dyna- Thread is more widely
accepted than lightwall threadable
• The exterior of Dyna - Thread is The internal surface of all black Allied where Sch-40 is specified.
protected by a clean, durable mill Tube & Conduit Fire Sprinkler pipe
coating for extended shelf life and products up to 4.5000" in diameter is
easy paint application. coated with our new Antibacterial
Formula, "ABF ". In scientific laboratory
test, ABS proved to have superior Specifications & Approvals
resistance to microbial colonization of
(1) ® 410 pipe walls, thereby delaying or possibly Super 40/Dyna- Thread pipe is
preventing the onset of manufactured to meet: ASTM A -135,
Microbiologically Influenced corrosion Grade A and is in compliance with
Listed Approved Listed NFPA -13. All sizes of Super 40/Dyna-
(MIC) when the First Sprinkler System
is first installed. Thread are rated at 300 psi working
pressure. Super 40/Dyna- Thread is UL
Specifications and ULC Listed for wet, dry deluge and
pre- action sprinkler systems and FM
NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ Wt/Lift (21') Wt/Liit (24') Wt/Lift (25') Approved for use in wet systems. Super
In; mm In; mm Lbs/Ft; Kg/m Lbs/Ft; Kg /m Lift Lbs; Kg Lbs; Kg Lbs; Kg 40/Dyna Thread can be "hot - dip"
1° 1.080 1.330 1.75 70 1955 2234 2327 galvanized to meet FM requirement for
25 27.4 2.0 2.60 70 887 1013 1056 dry systems. Super 40/Dyna- Thread is
11/4° 1.408 1.870 2.54 51 2002 2288 2384 approved for all threaded couplings and
32 35.8 2.8 3.78 51 908 1038 1081 welded outlets and is suitable for all
1' /z° 1.639 2.290 3.22 44 2115 2418 2519 roll - grooved, and plain -end fittings.
40 41.6 3.4 4.79 44 959 1097 1143 (See listing information).
2° 2.104 3.050 4.57 30 1921 2196 2287
50 53.4 4.5 6.80 30 871 996 1031
' • 16100 S. Lathrop • Harvey, IL 60426 Customer Service:
NCO /Flow Control n l 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882 -5543
TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708 - 339 -1806
S3 -3
f
{ Standards and Specifications �( / INT[NNAT101 1. �� "
IN:
' • ,
Dimensions Material Galvanizing Thread Pressure Federal/Other
Rating
M.I. Fittings .
Class 150 /PN 20 ASME 816.3• ASTM A -197 ASTM A -153 ASME 81 20.1+ ASME 816.3• ASME 816.3" •
Class 300 /PN 50 ASME 816.3• ASTM A•197 ASTM A -153 ASME 8120.1+ ASME 816.3•
M.I. Unions
r
I .
Class 150 /PN 20 ASME 816.39• ASTM A -197 ASTM A -153 ASME 8120.1+ ASME 816.39• A SME 816.39" •
Class 250 ASME 816.39• ASTM A-197 ASTM A -153 ASME 81 20.1+ ASME 816.39•
Class 300 /PN 50 ASME 816.39• ASTM A -197 ASTM A -153 ASME 8120.1+ ASME 816.39•
Cast Iron Threaded Fittings .
Class 125 ASME 816.4• ASTM A -126 (A) ASTM A -153 ASME 81.20.1+ ASME 816.4• ASME 616.411 .
Class 250 ASME 816.4• ASTM A -126 (A) ASTM A -153 ASME 81.20.1+ ASME 816.0 ASME 816.4111
C. 1. Plugs and Bushings
ASME 816.14• ASTM A - 126 (A) ASTM A - 153 ASME 81.20.1+ ASME 816.14• WW - 471
C. 1. Drainage Threaded Fittings
ASME 816.12• ASTM A - 126 (A) ASTM A•153 ASME 81.20.1+ ASME 816.12•
1 _ C. 1. Flanges and Flanged Fittings
Class 125 (1'-121 ASME 816.1• ASTM A -126 (A) or (8) ASTM A -153 ASME B1.20.1+ ASME 816,1 ASME 8163•
Class 125 (14' -up) + ASME 816.1• ASTM A -126 (8) ASTM A -153 ASME 81.20.1+ ASME 816.1 ASME 816.1-
Class 250 (11'-12') ASME 816.1• ASTM A -126 (A) or (8) �ASTM A -153 ` ASME 81.20.1+ r ASME 816.1 ASME 816.1•
Class 250 (14 - -up) ASME 816.1• ASTM A -126 (B) ASTM A -153 ASME 61.20.1+ ASME 816.1 ASME 816.1• .
Forged Steel Threaded Fittings
Class 2000. 3000. ASTM A105.
ASME 816.11• ASTM A182. ASME81.20.1+ ASME 816.11•
6000 ASTM A350
Pipe Nipples
Steel Pipe ASTM A733 AS A53 ASME 81.20.1+ WWN 351
F o
- Welded Type F or Type E
Steel Pipe W1"1N 351
- Seamless ASTM A733 ASTM A106 Gr. 8 ASME 81.20.1+
(High Temp.)
Brass ASTM 843 ASME 81.20.1+ WWN 351
The standard
•an American National standard (ANSI)
+ASME 81.20.1 was ANSI 82.1
*Formerly WW -P -501
••Formerly WWP -521
- • • •Formerly WW -U -531
PF -9491
P C••?O► ST-_E • PE- 1_ '10 • •ZOO C 10 0
j O ® 9 L'r C and 'MS Apor<.w: d. ` � \
• ix ck Ri � Duplj'"� SEEYICTAUIICPUBLICATI0 � F 0 ® - AILS =xi pac
STYLE 005
- WITH VIC-PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY)
FireLock Style 005 rigid coupling has a unique, patented angle -pad design which allows the + . 0
housings to offset while clamping the grooves. By permitting the housings to slide on the angled ,
bolt pads, rigidity is obtained.
Support and hanging requirements correspond to NFPA 13 Sprinkler Systems. Angle -pad design
permits assembly by removing one nut /bolt and swinging the housing over the gasket. This PATENTED
reduces components to handle during assembly.
- Style 005 FireLock coupling are designed and recommended for use ONLY on fire �C
Gasket System
protection systems.
V1C.PIUSTM Gasket System:
In North America, Victaulic` offers a gasket system which requires no field lubrication on wet IIII
pipe systems that are hydrostatically tested. The Vic- PIUSTra System (patented) is dry. clean, and
non - toxic. It reduces assembly time substantially and eliminates the mess and chance of over- .
lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (I -100) for
ii su pplemental lubrication requirements and dry pipe fire protection system notes. I',
Exagg,.>..hxd for clarify
LISTING /APPROVALS The information provided below is based on the latest listing and approval data at the time of
publication. Listings /Approvals are subject to change and /or additions by the approvals agencies.
Contact Victaulic for performance on other pipe and the latest listings and approvals.
Related Working Pressure - psi Related Working Pressure - psi Related Working Pressure - psi
i I , I I i
W J j 10E ( c 6, i1 .5,3 & 1 (kg l / pia ; Qt it f? I L 1 f
5 1 3 175 �.. 175 I 17S ''l 1 tk 300 N/A A MT i 1 2 300 N/A N/A
1 n 350 350 ' 350 ET 1 1 2 300 N/A N/A STF J I - 4 i N/A ^ A 300
an,, S t. 8 , 300 300 EZ 4 n 300; ./A 300 `Thda
10, 1 1 !a - _ Nr . A 300
dl_T I
t
<. 3t 300 N/A FF 11A __.. NN/A - N/A, 300 1...7 -3 A : N.' ` 300
pf I - 4 300 300 330 GAL - 7 1 ! 300 N/A ' N/A Wi.5 ■ I 2 300 300 NiA
I - 2 300 300 0A Mg 1 0 2 300 N/A ' '.A. X. I i 3 300 - 300 300
_F I 1 - 4 . 17St4 N/A I75 MI' . 1 i.r - 4 300 i N/A 300
' FM approved for i2rv1r e in 1 '._ - 4' pipe.
.. UL Ltd fig: ie •..02 up to 0' pipe only
::D iJL iiECcd `: t >er•i c up to 3' imh•
JOB /OWNER CONTRACTOR ENGINEER
System No. Submitted By Spec Sect Para
Location Date Approved
Date
- www.victaulic.com
vicrAl.IUC., iS A REGISTERED TRADEMARK OF VICTAl1L C COMPANY 8 27.06 VICIAU00 COMPANY ALL RIGHTS RESERVED PRINTED IN THE 1 /SA
�ctauiic
REV_1 10.02 1
IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.02
. Fire Lock® Rigid Coupling
STYLE 005
WITH VIC,PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY)
DIMENSIONS
Max. Work Max. End Allow. Pipe Bolt/No( Approx.
Size Pressure § Load • End Sep. t No - Size Dimensions - Inches/min Wgt. Each
ii 5
-
. Actual .
Nominal , Outside ; !
i
,...
.1811 Alt• 1W41111111 Size Diameter • PSI Lbs. : inches Inches Lbs. 1
011111P-Org Inches/bun : Mates/rum kPa. ; N, MID MT X X Z kg 1
FAIL 41 • .10 ,,,, ,.660 .35,., 75, .
32 ' 42.4 2413 3370 1.2 ' - 1 70 114 148 1 0.5
•■.• -11 "`" ••■•• 111111111 . --n-
114 i 1900 350 • 9900.05 1 _ „, x -,,,, ; 3.00 4 75 1.88 1 1.2
40 , 48.3 2413 : 4415 1.2 ; ' - . ! 76 121 148 1 0.5
• - - :-
Rated for , z,ier and dry sprinkler systems 3i 2 2.375 350 : 1550 0.07 1 . • - i 3.50 5.25 1.38 ; 1.6
m
350 2- kra 1br i l/, - 4'/32 - 100m 50 : 60.3 2413 1 6900 1.7 : x 2 8.9 L • 3
11. 148 i 0.7
ii-
sizes and 30) ps1/2.116810 'of 4 lA - 8"/108 2 V2 1 2.875 350 ' 2:70 ' 0 . 07 . „ .,„ 1 4 00 5.75 1.88 1 1.9
- 200 rnm 512.es; Schedule 10 roll grooved or 6c : 73.0 2413 i 10110 1.7 ; ' "' x ' ' : 102 146 146 i n
• . . •
Schedule 40 cur or ro o
ll gioved steal p .; ipe
. 3 COO 350 1 2475 i 4.3 5 7 5 1.88 : 1.9
e 0 rigid a Ccom date 6
Styl05 .s ncl does not amo 7.1mm . • 71,, x 2 1
0.07 1
' 2 - 1/2 1 105 "
11010 1.7 . 146 48
expansion contrrrc non or angular ileac non. :
3 1 3 500 350 3365 " ' • 1 4.63 6.13 1.88
80 1 38.9 2413 14935 1.7 ; 2 ---1s,x2v2 ! 118 156 148 i 1.0
4 ' 4 500 350 5565 0.16 i 1 5 • "
7 7.25 2.13 : 3.1
4 ! --in Y . "
100 1 114.3 2413 .1 2 x 2 2 24770 146 184 54 : 1.4
r._
4 750 300 4 255 0.16 1 1 5.63 7.25 2.13 . 3.1
108.0 mm 1 -,
4,1 1 2 - .1"3 x 2' ' - •
108.0 2063 18940 1 143 184 54 . 1.4
- -
5 : 5,5633O0! 7290 016 2 1/2 3 .
. 6 88 9.00 2 13 . 4.5
' . : - . ..
125 1 141 3 2068 :rz-.-?5 4.1 : ' : 1:5 229 54 1 20
c 2rsp 30) 6495 0.16 ; ' 6.63 9.00 2 13 : 4.5
133.0mm 1 -1 ...„1 ! 2 .21 - V2 ,'.. : •••
2068 28900 168 229 54 20
c 500 300 7125 0.16 1 2 _ ,,,, x 21 6.88 9.00 2 13 i 4.8
39.7 139.7mm 1 •-.
2068 31715 4.1 : : 175 229 54 1 22
8. : •
6 ! 6.625 300 10:3-;0 016 1 2 _ ,,•, 800 1 0.00 i 2 13 1 5.0
150 1 168.3 2063 46020 4.1 ' - 1 203 254 5 3 • 23
1 6 300 92i: 0.16 2 _ ti ,!, , 71 1 2 0 5 0 <;:i 1 1 2 11
59.0 mm . 25i)
159p 2068 40955 4.1 -
5 6 00 300 9955 0.16 . 2 _ _
10.00 , 2 13
165.1mm 1 165.1 2068 44295 4.1 . '' . 207 254 , 54 25
8 i 3625 300 17525 0.19 " 10 50 13.14 2.63 11.3
5 x % '
200 l 219.1 2068 78000 4.8 ' 2 - 5 . 4 1 267 334 1 67 ' 5.1
' 'Working Pressure and End LiNicla10 :oral, fiorri all internal and external loads, based on standard weight :ANSI)
steal :Noe, standard roll or cut grooved In accordance with Viclaulic specifications Contact Victauls: for per for-
:mance on other pipe
WARNING. FOR ONE TIME FIELD FEST ONLY. 354 Maximum Joint +Aronsing Pressure may be increased to 1 1/2 times
the figures shown.
t The anewabie ;)ip4 sePrarion dimension shown is 101 553010 layout purposes only. Style 005 couplings are con-
sidered rigid connections and will nor accommodate expansion of contraction 05 i he piping sysrem.
(53 Number 05 60115 required 011.143111111001 of 1301441110 segrriencs. Metric thlead size. baits are available (color coded
gold) for ail coupling sizes upon 'agues:. Contact Vicrauk for de:aik..
Style 005 couplings ai 0 VdS and LPC Approved to 12 43r5175 psi.
• www.victaulic.com
'
VICTAUL1G IS A REGISTERED TRADEMARK OF vic COMPANY , t 4 + 2006 VIOTAULiC COMPANY ALI. RIGHTS RESERVED PRINTED IN THE IJSA •ctaulic
10.02 2 REV
IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 1 0.02
Fire oc ® Rigid Coupling
STYLE 005
WITH VIC- PLUS"' GASKET SYSTEM (NORTH AMERICA ONLY)
•
MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A -536, grade 65- 45 -12. Ductile iron conforming to ASTM
A -395, grade 65- 45 -15, is available upon special request.
Housing Coating: Orange enamel (North America); red enamel (Europe)
• Optional: Hoz dipped galvanized
Gasket:
• Grade "E" EPDM — Type A Vic - Plus'" Gasket System A
(Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and
Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the
rated working pressure using the Grade "E" Type A Vic- Plus' Gasket System. requiring no field
lubrication for most installation conditions.
• Grade "L" Silicone
Recommended for dry heat. air without hydrocarbons to +350 °F and certain chemical services.
For dry services Victaulic continues to recommend the use of Grade "E" Type A FlushSeal° Gasket.
Contact Victaulic for details.
Bolts/Nuts: Heat - treated plated carbon steel, trackhead meeting the physical and chemical
requirements of ASTM A -449 and physical requirements of ASTM A -183.
A Standard gasket and FlushSeal gasket approved for dry pipe systems to — 40 "F / -40'C. Based on
"typical" pipe surface conditions, supplemental lubricant is recommended for services installed
below 0 °F 1-18 °C and for all dry pipe systems or systems to be subjected to air tests prior to being
filled with water. Supplemental lubrication may also be required on pipe with raised or undercut
weld seams or pipe that has voids and /or cracks at the weld seams. Victaulic continues to
recommend the use of FlushSeal gaskets for dry services.
www.victaulic.com
jctaulic°
VICTAUUC I'3 A REGISTERED TRADEMARK OF VICTAUUC COMPANY.* 2006 VIC'AJUG COMPA.NY. ALL ■::Gi-TS RESERVED. PRINTED IN THE USA.
REV ....I 10.60....3
+ �, 2 *a ''.a g'.`� s ,F; .a ,y . ..: +5 , S � ' .�-. � " �� �'fr ` ,e� ,r ^ � ;
G EL' IF E 0 GT 0 0 UC 5��?�sr� e i f s }r are O. °�K<�
FireLock Rigid Coupling
STYLE 005
WITH VIC- PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY)
GENERAL NOTES WARNING: Depressurize and drain the piping system before attempting to install, remove, or adjust
any Victaulic piping products.
WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details.
NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be
installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the
right to change product specifications, designs and standard equipment without notice and without
incurring obligations.
INSTALLATION Reference should always be made to the I -100 Victaulic Field Installation Handbook for the product
you are installing. Handbooks are included with each shipment of Victaulic products for complete
installation and assembly data, and are available in PDF format on our website at www.victaulic.com.
•
111 II I 1 III I III I II I II I II IIIII II III I II III I I
WCAS- 697KR4
For complete contact information, visit www.victaulic.com
10.02 1538 REV I UPDATED 9/2006 \irctcaluhlc
VICTAULC IS A REGISTERED - R.AOEMARK OF VIC?AULC COMPANY. C 2006 VIC"AUi C COMPANY ALL RIGHTS RESERVED. PRINTED IN THE USA
10.02
A ;o __• • _ -.�,• . •u•.► i• 15
C — - — 0 ® VdS (LPCB)
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS
STYLE 75
!Ea 11 1k,
Style 75 is available where moderate pressures are expected or weight
considerations are a factor. Up to 50% lighter in weight than the Style 77,
the Style 75 coupling is recommended for service up to 500psi13450kPa
depending on size. Housings are cast in two identical pieces in all sizes.
Hot -dip galvanized and special coatings are available for all sizes.
./Fesr ova
111111
Exaggerated Tex dart::
MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A -536, grade 65- 45 -12. Ductile iron conforming to ASTM
A -395, grade 65- 45 -15, is available upon special request.
Housing Coating: Orange enamel.
• Optional: Hot dipped galvanized and others.
Gasket: (specify choice *)
• Grade "E" EPDM
EPDM (Green color code). Temperature range -30 ° F to +230 °F / -34'C to +110 °C.
Recommended for hot water service within the specified temperature range plus a variety
of dilute acids, oil -free air and many chemical services. UL classified in accordance with
ANSI /NSF 61 for cold +86 °F / +30'C and hot +180'F1 +82 °C potable water service. NOT
RECOMMENDED FOR PETROLEUM SERVICES.
• Grade "T" nitrile
Nitrite (Orange color code). Temperature range -20 °F to +180 °F / -29°C to +82 'C.
Recommended for petroleum products. air with oil vapors, vegetable and mineral oils within
the specified temperature range: except hot, dry air over +140'F / +60 °C and water over
+150"F/ +66 °C. NOT RECOMMENDED FOR HOT WATER SERVICES.
' Services listed are General Service Recommendations only. It should be noted that there are
services for which these gaskets are not recomrnended. Reference should always be made to
the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a
listing of services which are not recommended.
Bolts /Nuts: Heat - treated plated carbon steel, trackhead meeting the physical and chemical
requirements of ASTM A-449 and physical requirements of ASTM A -183.
JOB /OWNER CONTRACTOR ENGINEER
System No. Submitted By Spec Sect Para
Location Date Approved
Date
www.victaulic.com
ictaulic'
VICTAU! iC IS .A REGISTERED TRADEMARK OF VICTAUUC COMPANY ," 2006 VICT.4NUC COMPANY ALL RIGHTS RESERVED PRINTED IN THE !.JSA - - �-�
REV H 06.05 1
• CARBON STEEL PIPE - GROOVED COUPLINGS 06.05
• Coupng
STYLE 75
DIMENSIONS
Max. Work Allow. Pipe Bolt/Nut@ Approx.
Size Pressure ' Max. End Load' • End Sep. t . Deflect. Fr. C.,.t No - Size Dimensions - Inches/mm Wgt. Each
&CM)
GtEM.0 Gaffe •
- e a a M o l e 8 4 4 3 ep •
Ka,
cam (..) a G5 cia De: j 0 Sy .g C13
: 1 315 • 500 680 0 - 0.06 ! ' 0.57 1 2.38 4.27 1.77' 1.3
, 2` i 2 - vs x 2
5 :
.
. 14 ' 3450 3025 0 1.6 48 61 1M 4 5 -rn 2 3 -
1 ',:, 1 1 660 ; 500 1060 0 - 0.06 :
2' - 10' : 0.45 2.68 4.61 1.77 1.4
1 2 - Va x 2
32 42.2 1 3450
. 4305 0 - 1.6 38 68 117 45
1 V.1 i 1 900 500 5
1.420 0 - 0.06 : 0,40 ; ., , . 2.91 4.32 1.77 1.5
1' • • , _ x 2
40 48.3 ! 3450 6320 0 - 1.6 6 33 74 122 45 ! 0.6
. .
2 I 2.375 ! 500 2.215 0 - 0.06 ' 3' : '0.32 2 1 3.43 5.22 1.38 1 1 . 7
, .- 1 2 - Y..< . 2
50 60.3 1 3450 9360 0 - 1.6 26 37 133 48 ; 0.8
2½ 1 2 875 i 500 3.245 0 - 0.06 ' 0.26 • 3.38 5.68 138 : 1.9
. ! , _ 1.i •( !,
65 73.0 ! 3450 14440 0 1.6 2' 98 144 46 0.9
•
6.1 rm.., t 1 3.000 1 500 3.535 0 - 0.06 .. , .,. 0.26 4.00 59C) 138 ' 1.9
! - .
' !
76.1 : 3 l
450 15730 0 - 1.6 22 ' . 102 150 48 ' 0.9
3 : 3 500 1 500 ...50,7 U - 0.:16 . - .„ 7 0.22 1 2 _
,. ..< , : 4.50 7.40 1.88 ' 2.9
80 88.9 1 3450 21360 0 - 1 18 - ! 114 178 48 1.3
3 v.: 1 4000 : 500 6.300 0 - 0.06 : n 16 ; - 5.00 7.50 1.88 ; 2.9
0' - 54' ' - 2 ' x 2 ,:: ! 127
93 1 101.6 1 3450 26035 0 - 1.6 191 48 1 1,3
•
4 1 4 5.00 I 500 7.950 0 - 0 13 1 0.34 i . .. 1 5 80 803 2.13
. - 36 '
: 2 - x 2 •,:, : ' 1 '
100 ; 114.3 .3450 35380 0 - 3.2 23 2 , 47 204 1 54
.
4250 ! 450 6.380 0 - 0 13 0.35 ! . - . 535 7.79 1 2.13 ! 3.7
108.0 mm ! 1080 ( 3100 L 28 0 395 - 41' ; 2-12x/0 14 - 1 0 !
- 3.2 •
198
• 29 54 ! 1 7
-
4 '.: 5 000 450 8.820 0 613
.25 ! 9.43 ' 2.13 ' 5.5
.
120 .1270 ! 3100 39750 0 - 3.2 - 2 . 71 , 156 240 , 54 , 2.5
5 '1 5 563 ! 450 10.935 0 - 0 13 ' - 0.27 1 . ! 6.88 10.07 1 2.13 5.8
1" - ; 2 .;3!.‹
125 1 141.3 i 3100 46'660 0 - 3.2 1 - 8
23 1 175 256 i 54 26
... .........
9.735 0 - 0 13 1 , _ ., • 0.28 2- ,,,, ,.; I 6.55 9.37 : 2.13 6.0
133.0mm 1 5 2•50 ; 450 , _
133.0 ! 3100 43325 0 - 3 ' .7 1 • • 24 ' ` ' `'` ' 166 , 236 ! 54
:
1 5 500 : 4 50 10.66S 0 - 0 13
• ! 0.28 i - ! 6.50 ; 9 59 : 2.13 .3
139.7mm •4 ; 139.7 1 3100 47460 0 - 3.2 2
1 - 18' ! : 2 - ',./ x 3 ,,:: : ' - -
1 4 . 173 • 244 , 54 , 29
; .
1 6 000 i 450 , 12.735 0 - . 013 ; . • 0.21 1 . 1 7.38 1 10.48 ! 138 . 5.2
152 mffi 1524 I 1100 1 ,6670 0 ._ 3. , -1.1 ! 18 1 2. % x 3 4 1 187 • 266 : 45 ' 2
: ! - ........ -
6 1 6 625 i 450 1 15.5.25 0 - 0 13 ; • . ' 0.23 1 . : 800 , 11 07 : 2.13 ' 7.0
.; • - ' .
15() I 168.3 1 3100 1 69,365 0 - 3.2 ! 145 : _03 281 54 ' 3.2
Continued on page 3.
' t @ * Refer to notes on page 3.
...
Vtro
gio Ira
Ilk AL riffs
Aw
ill .-_:.-,,-
- www.victaulic.com
vicTAuLic is A REGISTERED TRADEMARK OF VICTALkiC COMPANY C 2006 VICTALMC COMPANY ALL RiGHTS RESERVED PRINTED IN THE USA Ictaulic
06.05 2 REV .H
• CARBON STEEL PIPE - GROOVED COUPLINGS 06.05
•
(---, ,.
kitaurniimp.
• ir.- ..,
•
STYLE 75
• .
DIMENSIONS
Max. Work Allow. Pipe Bolt/Nut@ • Approx.
Size Pressure * Max. End Load * End Sep. t Deflect. Fr. C.,1 No - Size Dimensions - Inches/mm , Wet. Each
i Pgiv. ;(1 I
I •
Gfomitin0 1 &it/J. fc, 1 ' 1 .
• Cile.33 1 &.tkb 1 i 1 ffai. t a I 1
tL 1 a 1 afir>. , Wraita■ 1 1
CO 1 I
■ G5 fiz , M 1 usazo ! ugic.-s 13 i 2 & 1 It
i59.0 um , ! 6 250 ! 450 00 13.300 0 - 0.13 . . 7 -
' 9' - 0.24 -- 10.49 2.13 6.3
159.0 31 61405 0 - 3.2 20 2 16 82.5 , 194 266 54 3.1
14.940 0 - 0 13 23 7.84 10 66 2.00 7.2
165.1mm t 6 500 ' - 450 " - 6' 0. ., _ x
165.1 : 3100 66433 0 - 3.2 19 199 271 52 . 3.3
8 9°C) . 450 22.635 0 - 0 13 0.16 , .. 9.72
. . 13.33 231 12.6
203.2 ! 3100 100725 0 - 3.2 2 !
13 247 339 58 • 5.7
. ..._
8 : 8 625 ' 450 26.280 0 - 0 13 - 0.18 ! . ' 10.34 • 13.97 2.32 12.4
5y : .< , 4
200 : 219.1 . 3100 116945 0 - 3.2 0 14 263 355 59 5.6
-,--
: .
10 000 . 350 27..500 0 - 01 0. ... 43. - 0 i , - ., - .,, ' 12.16 15.81 2.53 203
254.0 rnm # 1 254.0 2.400 122375 0 - 3.2 11 i - , s . 5 :..
309 . 402 64 9.4
---
. 1:..000 : 350 39.500 0 - 011 0.13 ,,,.., 5 , - , . 14 - .16 17.69 2.53 . 23.6
304.8 mm # ' cv _ 36
.304.8 I 2400 175775 0-32 • 2 9 • 30) 149 67 10.
Working Pressure and End Load are total, from all Internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in
accordance wirh Victaulic specifications. Contact Victaulic for performance on other pipe.
WARNING: FOR ONE TIME HELD TEST ONLY, the Maximum Joint 'Working Pressure may be increased to I 1/2 times the figures shown
5 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved
pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be
reduced by: 5O% for 3 /4 - 3 1/2120 ---- 9()mm: 2556 for 4"1100mm and larger.
@ Number of bolts required equals number of housing segments.
Metric thread size bolts are available (color coded gold) for all coupling SiZeS upon request. Contact Victaulic for details.
..1 1 r z i
..i.4- it I mil
A ff a i Trip
M fl
re
www.victaulic.com
\lictaulic°
VICTAULIC IS A REGISTERED TRADEMARK 08 VICTAULIC COMPANY. 8 2006 VICIAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA - -
REV..11 06.05_3
' V . "1cTYx.M fY 4aR� � ..t �FaY��C� y �J5 r.�r'A a� `.+'k' Y ^ ' @,"' b 4 -,; ..
,� �34'n ,� v P � ?'J I n Jt 6 �� (� � ^YY'dY
.}% -k tv*' .V" i T4s ,.t» ,�. f.:> 'n " ' 4 e" YF .? yr ^ {" 3F , & , ':,;,+: ^C -b
��"��G..$ E " —"� R
QOV D� QU I C7S � � � � .
� � s� R�4r #� �'? '»� ? V ' 5Y` rG'�"�.c�_
L .
Coupling
STYLE 75
WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details.
NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All
products to be installed in accordance with current Victaulic installation /assembly
instructions. Victaulic reserves the right to change product specifications, designs
- and standard equipment without notice and without incurring obligations.
INSTALLATION Reference should always be made to the 1 -100 Victaulic Field Installation Handbook for the product
you are installing. Handbooks are included with each shipment of Victaulic products for complete
installation and assembly data, and are available in PDF format on our website at www.victaulic.com.
1111111111111111111111111111111111111111
WCAS- 6QAQQT
For complete contact information, visit www.victaulic.com
06.05 1470 REV H UPDATED 412006 V Ictau'1c
VICTAUUC IS A REGISTERED TRADEMARK OF VIC TAUUC COMPANY. t 2000 VICTAU iC COMPANY. ALL R GF TS RESERVED. PRINTED IN THE USA
06.05
IPS CARBON STEEL PIPE — HOLE CUT PRODUCTS 11.02
VICTAULIC'' 'SAN ISO rol CERTIFIED COMPAFTY
Styles 920 and 920N Mechanical -T® Bolted Branch Outlets
PRODUCT DESCRIPTION
Victaulic Mechanical -T°' Outlet provides a direct branch connection at any location a hole can be cut in
pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position
permanently. A pressure responsive gasket seals on the pipe O.D.
Cross -type connections can be achieved by utilizing two upper housings of the same style and size, with
the same or differing branch size connections. NOTE. Style 920 and Style 920N housings cannot be
mated to achieve a cross connection.
Style 920 and Style 920N Mechanical -T outlets are available with grooved or female threaded outlet.
Specify choice on order. Units are supplied painted with plated bolts. Galvanized housings are available:
supplied with plated bolts.
Styles 920 and 920N All sizes of Style 920 and 920N are rated at 500 psi (3450 kPa) working pressure on Schedule 10 and 40
carbon steel pipe. They may also be used on high density polyethylene or polybutylene (HDPE) pipe.
Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe.
- Style 920 and 920N are not recommended for use on PVC plastic pipe.
Standard piping practices dictate that the Mechanical -T Styles 920 and 920N must be installed so that
the main and branch connections are a true 90` angle when permanently attached to the pipeline surface.
Style 920 Cross
VdS g
See Victaulic
publication 10.01
Tor details.
See chart on pa ,qe 5
for pressure ratings.
MATERIAL SPECIFICATIONS
Housing/Coating: Ductile iron conforming to ASTM A -536. grade 65- 45 -12, with orange enamel coating.
Ductile iron conforming to ASTM A -395. grade 65- 45 -15, is available upon special request.
• Optional: Hot dipped galvanized
Gasket: (Specify choice')
• Grade "E" EPDM
EPDM (Greed color code). Temperature range -30 °F to +230'F ( -34'C to +110'C). Recommended for
cold and hot water service within the specified temperature range plus a variety of dilute acids, oil -free
air and many chemical services. UL Classified in accordance with ANSI!NSF 61 for cold .86'F
( +30'C) and hot +180'F (+82 °C) NOT RECOMMENDED FOR PETROLEUM SERVICES.
• Grade "T' nitrile
Nitrile (Orange color code). Temperature range -20'F to - -180'F ( -29 °C to +82'C). Recommended for
petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature
range. Not recommended for hot water services over +150'F ( +66'C) or for hot dry air over +140'F
( +60'C)
•Services listed are General Service Recommendations only. It should be noted that there are services for
which these gaskets are not recommended. Reference should always be made to the latest Victaulic
Gasket Selection Guide for specific gasket service recommendations and for a listing of services which
are not recommended.
Bolts/Nuts: Heat - treated plated carbon steel, trackhead meeting the physical and chemical
requirements of ASTM A -449 and physical requirements of ASTM A - 183.
a REGISTERED TRADEMARK OF `JICTAOLIC - 3 COPYRIGHT 2004 vICTAUUC - PRINTED IN U.S.A. - Situ `tNCAS- 678NLV 1480 REV G
United States • Phone: 1-800-PICK-VIC (1- 800 -742 -5842) • Fax: 610 - 250 -8817 • e -mail: pickvic@victaulic.com
Canada • Phone: 905 -884 -7444 • Fax: 905 -884 -9774 • e -mail: viccanada@victaulic.com
Europe • Phone:32 -9- 381 -1500 • Fax: 32 -9 -380 -4438 • e -mail: viceuro @victaulic.be
Central and South America • Phone: 610 -559 -3300 • Fax: 610 -559 -3608 • e -mail: vical@victaulic.com 1 Cta U' 1 C e
Australasia • Phone: 86 -21- 58855151 • Fax: 86-21-58851298 • e -mail: vicap@victaulic.com
11.02
DIMENSIONS
Y �2 -�{ Max. Dimensions - Inches/millimeters Aprx.
T I II Work Hoie Fem. WbsEkch
Run X X Br Branch Press. Dia. Thd. Grv. 9
� v Nominal Inches Style PSI +0.13 V V Fem.
4'.' ^ riil I r / mm No. kPa -0.00 T'• $s $ W Y Z Thd. Grv.
j 1 1 2 x (ai 500 1.50 2.00 1.5 "s 1.61 5.35 2 75 3.
�--/ 920N 3 i 51 64 - 4 136 70 1,5 � - � WI X fa) 500 150 1.97 2.53 -- 1.61 5.35 2.75 3.1 -
Styles 920 and 920N
X '1 20 920N 3450 39,'i 50 64 - 41 136 70 1.5 -
X l (a3 500 1.50 1 85 2.53 - 1.61 5 35 2.75 3.0 -
wlGrooved Outlet X 2s 920N 3450 33.1 47 64 41 136 70 1,4
X 1'h (a) t 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2
X 3' 3450 44.5 52 79 75 41 135 76 1.7 1.5
T } =-+) 1 X 1V2 U;) t 920N 500 44.5 52 1.75 2.03 2 3.12 1 61 5.35 3 25 3.C, 3.2
X 40 3450 q45 52 '0 0 79 41 136 83 1.7 1.5
t r Pig I
�► X ''2 (3) 500 1.50 2 21 2.74 1.86 5 64 2.75 3
I ^ ur. T : va 65 X 15 20N 3450 38.1 56 70 - 47 143 70 1,4 -
Z. = � ` X 'L, (a)
920N 500 1.50 2.1, °. L.7.1 - 4 7 5.t 2.75 3.0
X 20 3450 38.1 55 70 47 143 70 1,4
+ Iwo X 1 (a) 500 1.50 2.06 2.74 1 86 5.64 2 75 2.9
Styles 920 and 920N X 25 970N 3450 38,1 52 70 - 47 143 70 1.4 -
w /Female Threaded Outlet X 1'!, t (a) 920N 500 1,75 2.30 3.00 3.25 1.86 6.29 3.00 3.5 3.2
X 32 3450 44,5 58 76 83 47 160 76 1.7 1,5
X 1'/2 t (a) 920N 500 2.00 2 28 3.00 3 25 1.86 6 26 3.25 3.6 3.3
X 40 3450 50.8 58 76 83 47 159 83 1.7 1,6
NOTE: Style 920 and Style 76.1 mm X ) 12 (a) 920 300 1.50 2.22 2 75 - 1 88 6.46 3 16 3.9
920N housings cannot be x 15 2065 38,1 56 70 - 48 164 80 1.8 -
mated to achieve cross X 1 0 (a) 920 300 1.50 2.19 2.75 - 1 88 6.46 3.16 3.9
connections. 3 20 2065 38.1 56 70 - 48 164 80 1.3 -
X 1 (a) 300 1.50 2 07 2.75 - 1.88 6 76 3.16 3 3 -
These new 9 , size Style X 25 0 2065 38.1 53 70 - 43 164 80 1,7 -
NEW 920N products require a
HOLE SIZE
d ifferent hole size ,.533 X 17, la) .r 920N 500 1.75 2.30 3 00 3.31 1 92 6.29 3 00 3.5 3.2
the 5ryie 0 20 it replaces, >; 32 3450 44.5 58 76 84 49 160 76 1,0 1.5
for propel installation X 1 4, (a) 500 2.00 2 28 3.00 3 31 1.92 6 29 3.25 3.5 3.3
Use caution to assure 920N
the proper size hole is X 40 3450 50.8 58 76 84 49 16; 83 1.6 1.5
prepared for the specific 3 X '72 13) 500 1.50 2.52 3.05 - 2.28 6.15 2.75 3.4
size and style used. 90 X t 5 920N 3450 38.1 64 78 - 58 156 70 1,6 -
rahue to tr e the proper X 1f, (a) 500 1.50 2.49 3.05 - 2.28 6.15 2.75 3.4
hole size could result in 92UN
jo leakage and X 20 3450 38.1 63 79 - 5 156 70 1,6 -
property damage. X 1 (a) o?ON 500 1.50 2.38 3 06 - 2 28 6.15 2 75 3.3 -
3 25 3450 38.1 61 78 - 58 156 70 1.5 -
X 1'), T 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7
X 32 (b) 920N 3450 44,5 65 93 90 58 156 76 1.3
X 1'z (a) T 02014 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8
3 40 (51 3450 50.8 71 89 90 58 156 83 1.9 1,8
X 2 (a) 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.0 4.6
X 50 (a) 920N 3450 63.5 70 39 90 53 172 99 2,3 2.1
3'/2 X 2 920N 500 2.50 .. - 3 75 2.44 6 72 3.88 - 3.8
90 X 5 0 3450 53.5 - - 95 62 171 99 - 1.8
4 X '1) la) 920N 500 1.50 3.03 3.56 - 2.69 7.01 2.75 3.7 -
100 X 15 3450 38.1 77 90 - 65 178 70 im -
X '14 (3) 920N 500 1.50 3.00 3.56 - 2.69 7.01 2.75 3.7
X 20 3450 38.1 75 40 - 63 178 70 1,9 -
X 1 (a) 500 1.50 2.88 3 56 - 2 69 7.01 2 75 3.6
3 25 92ON 3450 38,1 73 90 - 68 178 70 1.8 -
X 1'1, (a) T 9204 500 1.75 3.03 3.78 4.00 2.69 7.01 3.00 4.0 3.6
X 32 (51 3450 44.5 78 96 102 68 175 76 1.9 1,8
X 1'7 (a) i 50 0 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9
X 40 O) 920N 3450 50.8 33 102 102 68 178 83 2.0 1,9
X 2 (a) 1 500 2.50 3 25 4.00 4 00 2.69 7 01 3.88 5.0 4.6
X 50 920N 3450 63.5 83 102 102 69 178 99 2,3 2.1
X 2'r2 (a) t 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5 0
X 65 920 3450 69.9 73 102 102 69 136 118 2,6 2.3
X 76.1 rltm 920 500 2.75 - - 4.00 2 69 7.34 4 63 - 6.4
3450 69.9 - - 102 68 185 118 - 2,9
X 3 001 , 500 3.50 3 31 4.50 4 12 2.69 7 73 5.12 8 4 6.4
X 80 �` 3450 88.9 84 114 105 63 196 130 3,8 2.0
108 min X 17, (a) 500 1.75 3 08 3.78 - 2.63 7.64 3.05 5.0
X 32 92014 3450 44.5 78 96 - 67 194 73 2.3 -
X 1 1, (a) 500 2.00 3.28 4.00 - 2.63 7.64 3.25 5.0
• X 40 92UN 3450 50.3 83 102 - 67 194 033 2,3 -
(able i:Cntnued on page 3. See notes on page 4
2 Styles 920 and 920N Mechanical -T Bolted Branch Outlets
11.02
DIMENSIONS
V 1.-z -11 SIZE Max. Hole Dimensions - Inches/millimeters Aprx. Wgt. Ea. 1 Run X Branch Work. Dia. Fem. Lbs./kg
1 Nominal Inches Style Press. +0.13 Thd. Grv. Fem.
V �� mm No. PSI/kPa -0.00 T " V $ # V t W Y Z Thd. Grv.
1 , ^ iii ter - 108,0 mm X 2 (a) J4 . 500 2.50 3.25 4.00 2.63 7.64 4.00 4.00 5.6
,_ -- ' - - -` 3 50 lON 3:50 63.5 33 10 "l. - 67 194 102 2,5
lyl 76,1 min 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.00
3450 69.9 73 102 102 67 194 109 203 20
? : 3 (a) 500 3.50 3.31 4.50 4.00 2.63 7.63 4.88 - 6.5
Styles 920 and 920N 920 ;
w /Grooved Outlet x 60 3450 8.9 34 114 102 s% 194 124 3,e
5 X I ' • 020 500 2.00 4.22 4 75 3 16 9.70 3 69
125 X 15 3450 50,8 107 121 80 246 94
X 1 (a) 1 9 500 2.00 4.03 4 75 4.75 3 16 9.70 3 69 7.4 7.6
X 40 92G G0 3450 50.8 'IO2 121 121 80 246 94 3.4 3.4
X 2 (a) 1 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0
rIX I Z
!�� 50 ; 53. 102 "127 121 80 24E 1I1 3.7 3.6
, T * T 'Mil / X 2'/2 (a) 1 ry .. 500 2.75 3 63 4.75 4 75 3.16 9 70 4.63 8.3 7.9
T `� >: 6i �c0 3450 59. 92 121 121 80 246 113 3.8 3.6
X 3 (a) 5 500 3.50 3.31 5.00 4.63 3.16 9.70 5.31 8.4 8.3
+ No X 80 92p 3450 38.9 97 127 113 80 246 135 3.3 4,0
Styles 920 and 920N 133.0 mm X 2 0 20N 500 2.50 3.75 4.50 3.17 8.00 3.88
w/Female Threaded Outlet so 3450 53.5 95 114 81 203 99
X 3 500 3.50 3.31 5.00 3.00 9.46 5.31
X 80 920 3450 38.9 97 127 75 240 135
139,7 1101 X 1 'r_ 5 920N 500 2.00 3.78 4.50 -- 3 30 8.23 3 25
X 40 3450 50.6 96 114 - 84 209 83
NOTE: Style 920 and Style X 2 1 500 2.50 3.75 4.50 - 3.30 8.23 3.88
920N housings cannot be X 0 920 3450 53.5 95 "114 - 84 209 99
mated to achieve cross 500 2.75 3.63 4.75 - 3.13 9.85 4.63 - 8.8
connections.
X '7b.1 inr11 (3115 920 1450 69.9 92 121 - 80 250 118 - 4,0
Thew new Size Style X 76,1 mm 020 500 3.50 - - 4.63 3.16 9.70 5.31 11.0 -
NEW 920N products require a 3450 83.9 178 30 246 135 5.0
HOLE SIZE iliffer3n! bete sire than X 3 500 3.50 3.31 5.00 4.63 3.16 9.85 5.38 14.0
the Style 1120 it replaces, X 33.9 9201 3350 88,9 96.80 127 113 80 250 137 6,4
for proper Installation: o X 1'1 500 1.75 4.43 5 13 5.13 3.79 9.15 3 25 - 4.8
Use caution to assure
the proper 3Ize hole i3 ,2014 150 3 32 (5l 3450 44,5 112 130 130 96 232 83 - 2.2
prepared for the specific X 1V2 (a) 1 92UN 500 2.00 4.40 5 12 5.13 3 79 9.15 3 25 5.4 5.1
size and style used. X 40 (bt 3450 50.8 112 130 130 96 232 83 2.4 2,3
Failure to u3e the proper
hole size could result in X 2 (a) 1 500 2.50 4.38 .x.13 5 "13 3.79 9.15 3.88 6.0 5.6
joint leakage and X 50 920N 3450 535 111 130 130 96 232 99 2.7 2.5
property damage X 2'/2 (a) 1 92 500 2.75 4 01 5.13 5 12 3.69 1 0 51 4.63 8.3 7.6
X 65 Cl 3450 59.9 110 130 130 94 267 118 3.8 3.4
X 76.1 min (3)(51 920 500 2.75 - - 5.21 3.69 10.51 4.63 - 8.4
3450 69,9 - - 132 94 267 118 - 3,8
X 3 (a) 5 500 3.50 4.31 5.50 5.13 3.69 10 51 5.31 9 9 8.4
x 30 920 3450 833.9 110 140 130 94 267 135 4,5 3,3
X 4 (a) 1 500 4.50 3.91 5.75 5.38 3.69 10.51 6 25 10.1 10.1
X 100 920 3350 114.3 97 146 137 94 207 159 4.6 4.6
159.0 mm X 1'i, 3 50X1 1.75 4.43 5 13 3 53 9.40 3 25
X 32 'UN 3350 44,5 113 130 92 239 83
X 1 'h (a) 920N 500 2.00 4.41 5 13 - 3 63 9.40 3 25 7.8 -
X 40 3450 50.33 112 (30 - 92 239 33 3.5 -
X 2 (a) 500 2.50 4.38 5.13 - 3.63 9.40 3.88 8 0 -
920N
x 50 3450 53.5 111 (30 - 92 239 99 3,0 ..
X 76.1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63
3450 69.9 111 140 130 92 239 118
X 3 500 3.50 4.31 5.50 5 13 3.63 9 40 5.31 8.10
x 30 920 3450 83.9 110 140 130 92 239 135 205.74
X 1 U8.0 rnm 920 500 4.50 - - 5.38 3.63 9.40 6 12 - 10.0
3350 113.3 _ - 137 92 239 155 - 4,5
X 114,3 mm 920 5D 114` "3 9550 1 143 9 ' 92 � 23 159 1 F 2
- 165:1 mm X 1 3, 92014 500 1.50 3.38 4.56 3.79 9.34 2.75
2 25 3 450 38,1 99 116 96 23 7 0
X 1'i 500 1.75 4.43 5 13 3 7.9 9.34 3 25
i20N
X 3450 44.5 113 130 96 23 83
' X 1 (a) 1 ,20N 500 2.00 4.41 5 13 3 7.9 9.34 3 25
x 40 3450 50.8 112 130 96 237 23
X 2 (a) 5 500 2.50 4.38 5.13 3.79 9.34 3.88
9200
x 50 3450 53.5 111 130 96 2 ;'3.7 99
X 2'17 1 920 500 2.75 4 01 5.13 - 3.63 10.51 4.63 3.6 7.6
X 65 3450 09 9 110 130 ... _ 92 267 118 3,9 3 4
Table continued on page 4 See 00105 on page 4.
Styles 920 and 920N Mechanical -T''' Bolted Branch Outlets 3
11.02
DIMENSIONS
• y . Z SIZE Max. Hole Dimensions - Inches/millimeters
Run X Branch Work. Dia.
t I - I Nominal Inches Style Press. +0.13 Aprx. Wgt Ea.
y Vi i� mm No. PSUkPa -0.00 LbsJkg
ii i11 I711 165.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6
X 76.1 min (a)(b1
_P1 3450 6.9.9 110 130 132 92 6 118, 3.9 3.4
`j X 3 (a) T 920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4
+ IVI X 80 3450 88.9 110 140 130 92 267 135 4.6 3.8
X 4 (01 t 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4
Styles 920 and 920N x 100 3450 114.3 97 146 137 92 267 '159 4.8 3,8
w /Grooved Outlet 8 X 2 (a) 500 2.75 5.44 6.19 - 4.81 12.42 4.50 11.6 -
920
200 X 50 3450 69.9 138 157 ._ 122 316 114 5.3 ...
X 2!, 1 l�a) T 920 500
450 2.75
.i.9 5 6.19 6 157 19 4.81 2 12 316 7.1 0 11.6 15.3
r 3 (01 T
A0 920 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6
3450 S8,9 135 165 165 122 316 135 5.' 5.3
V t X 4 (a) T 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5
ASS 1111 T in 100 920 3450 114.3 122 171 162 122 316 153 6.9 5.7 Allik _ T l I
_ i Ivl
Styles 920 and 920N
w /Female Threaded Outlet
NOTE: Style 920 and Style
920N housings cannot be
mated to achieve cross
connections.
These new size Style
NEW 920N products require 3
HOLE SIZE different hole size than
the Style 920 it replaces.
for proper installation
Use caution to assure
the proper size hole 15
prepared for the specific
size and style used.
Failure to use the proper
hole Size could result in
joint leakage and .
property damage.
NOTES
"Center of run to engaged pipe end.
female threaded outlet only (Dimen-
sions approximate).
Avaiiate with grooved or female
threaded outlet. Specify choice on
order.
1 Center of 151110 end of Lining.
a Female threaded 0141515 are avail -
able to NPT and BSPT 5peci[catior
(a) British Standard female pipe
threaded outlet is available as listed.
Specify 'BSP1"' clearly on order
(01 For 76.1 min threaded Outlet. spec-
ify 3`74' B5P(' clearly or order.
4 Styles 920 and 920N Mechanical -T Bolted Branch Outlets
11.02
FLOW DATA
0
OUTLET SIZE Equivalent Length
OUTLET SIZE Equivalent Length
Feet/meter of Pipe Feetlmeter of Pipe
Nominal Actual Nominal Actual
Diameter Out. Dia. Female Diameter Out. Dia. Female
I InJmm Grooved Threaded InJmm l
tnm Grooved Threaded
6
S 1 i, 0840 20 2 2.375 9.0 10.5
/'l, 15 21.3 - 0.6 50 60.3 2 3.2
J - '
ILf!I 1.050 40 2 2 .875
11.0 .
�� 2 0 26.? 1.2 .0 3.8 12
1 315 5.0 3.5
1 15.5 5
25 33.7 - 1,5 80 88.9 4.1 4.7
Exaggerated for Clarity 11 1.660 5.5 6.0 4 4.500 20.0 22.0
- Flow test data has shown that 32 42.4 1.7 1.3 100 114.3 6.1 6,7
the total head loss between l'!. 1.900 7.0 8.0
point (1) and (2) for the Style 40 48.3 2.1 2.3
920. 900N and 929
Mechanical -T' fittings can Formulas for CV Values:
best be expressed in terms of
the pressure difference across 1P = 02 Where:
the inlet and branch. The C "
i 0 =. Flow (GPM) Cv = Flow Coefficient
pressure difference can be
obtained from the relationship Q _ C x .AP = Pressure Drop (PSI)
to the right.
Cv Values Pipe Size Pipe Size Pipe Size
Values for now of ‘ at Actual Actual Actual
Nominal Outside Nominal Outside Nominal Outside
+60 °F ( +16'C) are shown in Diameter Diameter Cv Diameter Diameter Cv Diameter Diameter Cv
the table at right. Inches/mm Inches/min Values Inches/rim inches/mm Values Incheslmm Inches/trim Values
1 !• 0.840 1' 1 '1.660 45 21/' 2.875 135
15 21.3 32 42.4 65 73.0
'9 1.050 1 '1.900 3 3.500
20 26.7 71 40 48.3 60 80 88.9 200
- I 1.:315 2 2.375 4 4.500
25 33.7 25 50 60.3 00 100 113 3 400
APPROVED PRESSURE RATINGS
The information provided below is based on the latest listing and approval data at the time of publication.
Listings /Approvals are subject to change and /or additions by the approvals agencies. Contact Victaulic
for performance on other pipe and the latest listings and approvals.
Rated Working Pressures
Run Size PSIlkPa
Actual
Nominal Outside
Diameter Diameter Outlet Size Pipe
Inches/mm Inches/1nm Inches/mm Schedule UL ULC FM
2`!_ 6 2875 • 6.625 400 400 400
Ali 10. 40
65 - 150 73,0 • 168.3 2755 2755 2 755
2 • 4 2.875 - 4.500 All DF 300 300 300
100 73.0 . 114.3 2065 2065 2065
2',' : . 4 2.875 - 4.500 300 300 300
65 • 100 '7 3 0 . 114.3 All SF 2 2065 2065
6 6.625 300 300 250
150 16x.:3 3 . a 10 2065 2065 1724
6 6.625 300 300 300
150 168.3
3,4 30, 40 2065 2065 2065
8 8.625 400 - -
21)) 2;9.1 2 1 0.40 2755 - -
8 8.625 300 - 250
2110 219.1 3.4 10 2065 - 1724
8 8.625 3 300 -- 300
3
200 71111 .4 0.4 2065 - 2065
NOTES: '10 refers to Listed/Approved Schedule 1 10 steel sprinkler pipe.
40 refers to Li stediApproved Schedule 40 steel sprinkler pipe.
DE re`er5 t0 Listed /Approved Dyn::; -r1ow steel sprinkler pipe manufactured by American tube Company.
00 refers to Listed /Approved Super.Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corpotis'lon.
This product sha11 be manufactured by Vi(aaulic Company. •411 products to be installed in accordance ::ill ! by I� I current 4iclaulic inst;.+lla[irnr,35sernLly ulstru ;alc:r:,
Viciauir.: reserves 1110119ht I0 change produce specifications, design and standard equipment without notice. and •ithoi.il inc ;urr109 obliga110ns.
Styles 920 and 920N Mechanical -T" Bolted Branch Outlets 5
"+- '' `- a -..' "f7. < „�Tt. ” .. as*r • s 'ri.„' Y �t a •4" '. `.4 r.. ,..: • ,',j °4�t wr, w ' : ... t , t .
s � :. � tv�t £ : ±h E%� ?r, ., �� s,'F . # '9Em 'p . J�. ti. .� ?";= ' Z_� B;
y �p q �� ?�,� k S F' y � '�F
AaH. � � d LC y:`7 y -, + q t ✓^d, N✓ ,:si k . ! a . 0 ff ♦ 4 E , uj.
'� - ,.' t u w _ „ c ,'�':yL,� " 7 .y r�dr° 8 t '' � z� � i �. �� r e ' 6 / r . �� � x � � ' qr. P WWW tOICO COFTIL s 3 v �0 . x i '' '. + r, ,�;� ". � ' " +r , „ _zas - r- e � f”: >rt�lt+ fss'..� „sue. ".�. +73P�• � ,.` tp; ° • ,,M v� `''"' i.'-.,' a.'," TC "�._R2VIS�on`5I24 /200;1k^�,�Y
t d " • ";,E" .: ."- +4�1 /,�� N�BCO ic . � -: �. .Fri - - t'i y' ".'s.
Fig. 2 - Adjustable Band Hanger ®
Fig. 2NFPA - Adjustable Band Hanger with Reduced Rod
Size Range — Size 2' /2" thru 4" pipe. w
•
• Material — Carbon Steel, Pre - Galvanized , -, 1
Function — Recommended for the suspension of non - insulated F "' . C
• pipe or insulated pipe with Fig. 220 shield. .. ,-- .. �•.
• Fig. 2NFPA accommodates the reduced rod schedule of the r ~� ' , •
National Fire Protection Association Pamphlet 13. r'' j �
Approvals — Underwriters' Laboratories Listed in the USA (UL) / t
• and Canada (cUL). Factory Mutual Engineering approved. ` - * `'
Conforms to Federal Specification . B /
WW -H -171 E, Type 10 and Manufacturers Standardization Society ... ' , f
SP -69, Type 10. r '
Finish — Pre - Galvanized Av' 1:-. � ii
Note — Available in Stainless Steel materials.
Order By — Figure number, pipe size and material '
Dimensions a Weights
Pipe Max. Rec. Approx Wt. /100
Size Rod Size A B C Load Lbs. Fig. 2 Fig. 2NFPA
2 1/2' 5 4'/. 1'/d 600 41 40
3 1/2* 6 4' /8 1' /. 600 45 43
3' /, 1/2* 73/8 51/4 21/8 600 52 50
4 5/8" 7 5 1 /8 1000 59 56
5 5/8 ** 9 678 2'h 1250 97 95
6 3/4 ** 9' /8 6 1' /d 1250 139 105
• 3/8" nut is used when NFPA rod sizing is requested.
•• 1/2" nut is used when NFPA rod sizing is requested.
+c- Main Office /Manutacouing Facility • 1375 Sampson Ave . • Corona CA 92879 • Ph: `.:.09 737 5599 • Fax 900.737 0330
Z2� Customer Service • 800.786.5:66
www.totco.com
CAT Wood 44.,
I
, . ....
os urearimmkio."0-0-4140000000
SAMMYS
• WOOD • 1/4u Rod • Vertical Mount Box quantity 100 except as noted with this marking (•)
USB#14 Nut Driver (Romani(?) • Box quantity 50 •
Item # Model ' Rod Size Shk Dia ' Shk Lgth
•
20 , GST .750 1/4-20 1/4 3/4 .
. iti.titrantooh)
21 ,GST 100 1/4-20 1/4 1
22 ' GST 200 , 1/4-20 1/4 2
... . . . . .. . .. .
23 ; GST 300 I 1/4-20 ; 1/4 3 !
- ------ ---- — ------ -
24 • GST 600 See page 13 for Stainless Steel
' 1/4-20 1 1/4 . 6
WOOD • 318° Rod • Vertical Mount Note: Screws less than 2" in
- ngth will plated
Use d14 Nut Driver (Item #100)
le be yellow. Greater than 2" are deaf
FM Test UL Test UUR101 I zinc per ASTAIB633111
Item # Model . Rod Size Shk Ola Shk Lgth . Load, lb. Load, lb. ' Pipe Size , Actual Pullout
..
10 ' GST .75 ' 3/8-16 1/4 : 3/4 : 564# - 6 Ry
_ —r—
11 GST 10 . 3/8-16 i 1/4 1 210# - 7/16 OSB
670# - 3/4° Phi ,
' .. -• .
.set. 12 GST 20 , 3/8-16 . 1/4 ,, 2 940# ; 850# 3/4-21/2 1760# - Fr
t 27 • GST 25-380 i 3/8-16 3/8 : 21/2j , 1500# : 4 2113# - Fr
4 13 GST 30 1 318-16 1/4 : 3
. , 1475# 1500# : 3/4-4 2060# - Fr
403 • GST 40 3/8-16 , 1/4 i 4 1 2180# - Fr
14 • GST 60 1 3/8-16 1/4 i, 6 ,
. .
WOOD • 112" Rod • Vertical Mount
Use tigISW Nut Orhter (item#101)
"111
,
1 Item # : Model .., !Rod Size C4a Lgth i Actual Pullout
8 • .GST 2 ; 1/2-13 i 1/4
2 . 1760# - Rr oi.ksw ate. #101)
Note: the 1114SW mast be used
. 06 • GST 2.5-384, 1/2-13 i 3/8 — 2 1/2 : 2113# - Fir
. . far screws with la" cep
15 • GST 3 . 1/2-13 i 1/4 3 , 2275# - Fr_ ,.
16 • ,GST 4 1/2-13 . 1/4 ; 4 : 2180# - Rr
--?.----
• 17 • GST 6 — ' 1/2-13 . 1/4 I 6 ; 2230# - Fr 1 Installations Not less than
2" nominal width
(1 1/2)
See Page S for installation instructions. <
I , i /N i l
Installation ( .
' . TO per NFPA 13 ii,
. ,
i I f
gig St mg 4.0 &WM I. 1 3
:',--
iii
6 ..... - i TGI Joist/Truss t .1
0 Consult truss manufacturer for
reeorronended Installation point.
Wood Flooring (See "Special Notes" 1:!
#
on Valle ii iii
MIIIIESIMISM11/11111111111111111615 1.:1,
• ,.:,,,,
I p... Wood Joist Lower face ot re
. , beam or Whit •
40. ill Minimum r Embedment into base
r :-.. Aft.
- — _ — -- - - - =to mat fin NFPA 13 compance .-, For vertical am
- li i install in center f '
e g .. samm ii ot lower face.
Double Sheetreek Coiling I
';'?... It you don't tata it, can us at
.11 1.888.773.0801 1 1
1
4 Wood - Sammys 1 5 Note: Must be installed with appropriate nut driver to comply with warranty.
.,,
SIC , . � . .... w ., rvr�+�.�."rs- . h �L.
4 „„ i „,........
See page 13 for Stainless Steel SIDEWINDERS
• WOOD • 1/4" Rod •Horizontal Mount Box quantity 100 except as noted with this marking ("•)
USt4SW Nut Driver fie; MA] I) • Box quantity 50
Item # Model . Rod Sze l Shk t a Shk Lgth Actual Shear/Pullout ausw,llca� cot)
300 ; SWG 200 1/4-20 1/4 2 1725# - Fr •
Note: Screws Less than 2" in length
WOOD • 318 n Rod • Horizontal Mount win be plated yellow. Greater than
Use #14SW Nut Driver (item 1101) 2" are clear zinc per
•
— _ r
i C UL Test UL Pipe i Actual ASTbtB6331/!
Item #` Model Rod Size Shk Dia Shk Lgth! Load, Ib. Size ; Shear/Pullout
18 !SWG 10 3/8 -16 ; 1/4 1 at.tsw them OM
19 SWG 20 I 3/8-16 1/4 2 1250# 3 1725# Fr
n t 26 •SWG 25- 380 3/8 -16 3/8 ' 2 1/2 ; 1500# : 4 2249# - Fr •
25 •.SWG 30 • 3/8-16 - 1/4 3 , _ ...._. -_ ....__._... .__
If fastening through gusset plate. use the SW12 20 (see page 5)
Installations
TGI Joist / Truss
Consult truss manufacturer for
il recommended instaftation point
(See
"Special
Joist » I Sidewinder •-• c "
1� `- Sldawlndar
111
/'
WOOD INSTALLATION INSTRUCTIONS
111
GST & SWG — See diagram figures 1- 4,11 -14 on page
18 and 19. Not leas than 2" nominal width (1 1n")
(Sell drilling & sell - tapping into wood) up to 3112" pipe: not lees than 3"
nominal width 4" it 5" pipe
Step 1: Insert the appropriate nut driver into a 3/8" or 1/2" 4-- >
portable drill: (a) Use #14 for GST for 3/8" and 1/4" rod: (b) Installation
use #14SW for SWG, and for GST for 1/2" rod. per NFPA 13
Step 2: Insert the screw into the nut driver. Now you are
ready to install the screw.
Step 3: Position drill and begin installation: (a) for installing
GST drill should be in a vertical position; (b) for installing
.
SWG drill should be in a horizontal position at a right angle -. — .: , « swimmer
to the structural member. Minimum 2112" from bottom for ^ ig
branch lines. Minimum 3" from
Step 4: When the nut driver spins freely on the cap of the bottom for main lines. Exception:
This requirement shaft not apply to 2"
screw installation is complete. or thicker nailing strips resting
on top of .ton beams. a
'; Step 5: Screw is now ready to receive 1/4 ", 3/8', 1/2" or v
metric all thread rod or bolt stock.
Eye protection should be worn at all times when Install- 1 IF
Ing this product
Note: Must be installed with appropriate nut driver to comply with warranty. Wood - Sidewinders 5
Bulletin 117Rev.Q
oD
. ® Model F1
ciT
Model F1 Recessed
Standard Response
xi
cp
S • rinklers 5,
The Designer Model F1 Sprinkler =
Standard Upright'
Standard Pendent
• Extended Coverage Pendent kt
Conventional
Vertical Sidewall 4 �Jt'.
• Horizontal Sidewall Upright Pendent
- HSW 1 Deflector -
Horizontal Sidewall Extended Coverage
( 4 ,,,* ..,,,,...
- EC-6 Deflector
The Designer Model F1 Recessed Sprinlder
Recessed Pendent ik .,
Recessed Extended Coverage Pendent �_
Recessed Extended Coverage Horizontal Sidewal Vertical Sidewalk Conventional
Approval Organizations
1. Underwriters Laboratories Inc. - ^--`'
2. Underwriters' Laboratories of Canada ' '`" """'`'
3. Factory Mutual Research Corp.
4. Loss Prevention Council " 'VS \
5. NYC BS&A No. 587 -75 -SA Horizontal Sidewall Recessed Pendent
6. Pleniere Assemblee
7. Verband der Schadenversicherer _
8. NYC MEA 258 -93 -E i `r
UL Listing Category `
Sprinklers, Automatic & Open (VNIV) �`� � � i�'
i
Product Description Extended Coverage Recessed Extended
The F1 Glass Bulb Sprinkler combines the durability of a Horizontal Sidewall Coverage Horizontal
standard sprinkler with the attractive low profile of a decora- Sidewall
tive sprinkler. Whether installed on exposed piping or in an
office ceiling, it is functional and attractive. The Horizontal t LA _ _
and Vertical Sidewall Sprinklers provide an equally attractive •
appearance when ceiling piping cannot be used. `
Beautifully versatile is the description for the Reliable
Model F1 Recessed Designer glass bulb sprinkler. Re-
cessing The Designer enhances its already low profile dec-
orative appearance, and facilitates a rapid and perfect Extended Coverage Recessed Extended
installation. Pendent Coverage Pendent
Model F1 Recessed Designer's escutcheon is highly ad- At normal temperatures, the glass bulb contains the fluid in
justable. The two piece construction makes field installation a both the liquid phase and in the vapor phase. The vapor
• very easy and rapid task. This also allows ceiling panels to phase can be seen as a small bubble. As heat is applied, the
later be removed without shutting down the fire protection liquid expands forcing the bubble smaller and smaller as the
system, thus facilitating maintenance of above ceiling ser- liquid pressure increases. Continued heating forces the liq-
- vices. uid to push out against the bulb, causing the glass to shatter,
The Designer Automatic Sprinkler utilizes a frangible opening the waterway and allowing the deflector to distribute
glass bulb. The glass bulb consists of an accurately con- the discharging water.
trolled amount of special fluid hermetically sealed inside of a The F1 Sprinkler temperature rating is identified by the
- precisely manufactured glass capsule. This glass bulb is color of the glass bulb capsule as well as frame color where
specially constructed to provide fast thermal response. applicable.
The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552
Model F1 Upright, Pendent & Conventional Sprinklers
Installation Wrench: Model D Sprinkler Wrench
' ' 4'
ti ,,,,,,,,,, 4.
. _ it
'I: -`,, ' , t ..„ ,, 1
;`', \ I 4 RAS
Upright Pendent Conventional Upright (2)
Installation Data:
Nominal Sprinkler
Nominal Thread Sprinkler Approval Identification
Orifice Size K Factor Height Organization Numbers (SIN)
US Metric Upright 1 Pendent
Standard - Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position
'h" (15mm) 'h" NPT (R1/2) 5.6 80 2.2" (56mm) 12,3,4,5,6,7 R1725 R1715
' %2" (20mm) 3 b" NPT (R (1) 8.0 115 2.3" (58mm) 1,2,3,4,7,8 R1722 R1712
' /x" (15mm) '/z" NPT (R1/2) 5.6 80 2.2" (56mm) 7 R1795 R1705
'/32" (20mm) 3 /4" NPT (R 8.0 115 2.3" (58mm) 7 R1792 R1702
X" (11mm) 'h" NPT (R'/) (2) 4.2 60 2.54" (65mm) 1,2,8 R1723 R1713
3e" (10mm) 1/2" NPT (R1/2) (2)(3) 2.8 40 2.54" (65mm) 1,2,8 R1721 R1711
10mm XLH R 3 /e 4.2 60 56.1mm 4,6,7 R1724 R1714
Conventional - Install in Upright or Pendent Position
10mm XLH R % 4.2 60 56.1mm R1774
15mm 1/2" NPT (RY) 5.6 80 56.1mm 4,6,7 R1775
20mm 3 4" NPT (R 8.0 115 _ 58.1 mm 4,7 R1772
") LPC Approval up 286 °F (141 °C)
(2) Small Orifice identified by a pintle extending beyond the deflector.
(3) FM Approval for SSU only, up to 200 °F (93 °C).
(4) VdS Approval for Intermediate Response 155 °F (68 °C) only.
. 2.
Model F7 Recessed Pendent Sprinkler
Installation Wrench: Model RC1 Sprinkler Wrench
—2 //4 - „Orr O&—.
(521.4
1 re/r•
(49)
r i- � -i
rum, couuAa (zs. x �z7 )
•.,„ kii �� t 1�
�;>R,y, _ �ti ii�
F1 Recessed �' ve— I
!I , tn..)
1771eX 1A 2 27/Z' Oft
r72 °)
(2) When installed directly into a tee, the escutcheon dimension's
adjustment will be reduced.
Installation Data:
Nominal Sprinkler
Nominal Thread K Factor Sprinkler Approval
Orifice Size Height Organizations uidentification
Numbers
US Metric Numbers (SSI N)
y," (15mm) X" NPT (R),) 5.6 80 2.2" (56mm) 1,2,3 ",4,5,7 R1715
'X„" (20mm) y;" NPT (RX) 8.0 115 2.3" (58mm) 1,2,3 ",4,8 R1712
X" (15mm) Y," NPT (R),) 5.6 80 2.2" (56mm) 7 R1705
'X," (20mm)t X" NPT (RX) 8.0 115 2.3" (58mm) 7 R1702
%" (11mm) (2) y," NPT (R1/2) 4.2 60 2.54" (65mm) 1,2,8 R1713
X" (10mm) (2) y," NPT (R1/2) 2.8 40 2.54" (65mm) 1,2,8 R1711
lOmm R X 4.2 60 56.1mm 4)3),7 R1714
(1) FM Approval
• Light Hazard - No Limitations.
• Ordinary Hazard - Groups 1 & 2, Wet Systems only.
(2) Identified by a pintle extending beyond the deflector.
(3) LPC Approval is XLH, OHI and OHU Occupancies only,
57 °C through 93 °C ratings.
(4) VdS Approval for Intermediate Response 155 °F (68 °C) only.
3.
Model F1 Vertical Sidewall Sprinkler
Installation Wrench: Model D Sprinkler Wrench
Installation Position: Upright or Pendent
• *
Approval Type: Light Hazard Occupancy i
4 1114
It
_ Vertical Sidewall
U.S. Patent No. 6,374,9201
Installation Data:
Nominal Approval Sprinkler
pr l
Nominal Thread K Factor Identification
Orifice Size US Metric Height Organizations Numbers (SIN)
)" (15mm) }z" NPT (RX) 5.6 80 2.2" (56.1mm) 1,2,3,4 6 ,8 R1785
(1) LPC Approval is pendent only, 57 °C through 93 °C ratings.
Sprinkler Deflector to
p Ceiling Distance
Type (Min. - Max.)
Upright 4 "(102mm) - 12 "(305mm)
Pendent 4 "(102mm) - 121305mm)
Model F1 Horizontal Sidewall Sprinkler
Deflector: HSW 1
Installation Wrench: Model D Sprinkler Wrench Y """"°
Horizontal Sidewall
Installation Data:
Nominal Approval Organizations Sprinkler
Nominal Thread K Factor Sprinkler Identification
Orifice Size Length Light Ordinary Numbers (SIN)
US Metric Hazard Hazard
• 1 /2" (15mm) 1/2" NPT (R 5.6 80 2.63" (67mm) 1,2,3,5 1,2,5 R1735
Note: UL and ULC Listing permits use with F1 escutcheons, light hazard only
4.
. Model F1 Extended Coverage Pendent Sprinkler
Deflector: EC Pendent e A .rc
Installation Wrench: Model D Sprinkler Wrench
. Approval Type: Extended Coverage - Light Hazard Occupancy q ;'
• a
1;' {�
Installation Data: ' ,Ni
Nominal Thread Nominal rinkler Approval Temperature Sprinkler .. • ¢--
K Factor Rating Identification
Orifice Size US Metric Height Organizations °F oC Numbers (SIN)
, r.,,," (20mm) 3;" NPT (R 8.0 115 2.2" (56mm) 1,2,8 135; 155 57; 68 R1742 Extended Coverage
• };" (15mm) Y,," NPT (R'/) 5.6 80 2.2" (56mm) _ 1,2,8 135; 155 57; 68 R1745 Pendent
COVERAGE AREA
Pressure
Flow Rate Nominal Max. Area
_ Width x Length
K =8.0 (115) K =5.6 (80)
gpm L/min psi bar psi bar ft. x ft. m x m
26 98.4 10.6 0,7 21.6 1,5 16 x 16 4.9 x 4.9
33 125.0 17.0 1,2 34.7 2,4 18x18 5.5x5.5
40 151.4 25.0 1,7 51.0 3,5 20x20 _ 6.0 x 6.0
Model F1 Recessed Extended Coverage Pendent Sprinkler
Deflector: EC Pendent
Installation Wrench: Model RC1 Sprinkler Wrench - 1/4 mat
Approval Type: Extended Coverage - Light Hazard Occupancy 071n""'
1 15/16 5u
(<y .2mm)
r t i , 1' X 4'
4 __ [15.4 � 1.4
IlFN COLLAR 1 1' X I/2 !MOWER
UNIX RCN! - - _ - - '25,Imm X 12..7nm]
AGAINST 9055 1R
*REA°. 1
BOSS , \ II
,' .per I f ! -1 I
A
" J /X , A WU5 14 EN ! (I) r L�S!f. 15/1e
lir (218.4 (19 f � '_ /,,,,
Extended Coverage A
__ _ (` ' ^`")
Recessed
r t wat= 2 27 /Ar at
(72.2nunj
( "When installed directly into a tee, the escutcheon
dimension's adjustment will be reduced.
Installation Data:
Nominal Temperature Sprinkler
Nominal Thread K Factor Sprinkler Approval Rating Identification
Orifice Size US Metric Height Organizations , oC Numbers (SIN)
1 X," (20mm) X" NPT (R /,) 8.0 115 2.2" (56mm) 1,2,8 135; 155 57; 68 R1742
Y," (15mm) y," NPT (R') 5.6 80 2.2" (56mm) 1,2,8 135; 155 57; 68 R1745
COVERAGE AREA
Pressure
Flow Rate Nominal Max. Area
Width x Length
K =8.0 (115) K =5.6 (80)
gpm L/min psi bar psi bar ft. x ft. m x m
26 98.4 10.6 0,7 21.6 1,5 16 x 16 4.9 x 4.9
33 125.0 17.0 1,2 34.7 2,4 18 x 18 5.5 x 5.5
40 151.4 25.0 1,7 51.0 3,5 20x20 6.0 x 6.0
5.
Model F1 Extended Coverage Horizontal Sidewall Sprinkler
Deflector: EC -6
. Glass Bulb: 3mm 155 °F (68 °C) Standard, Unless 5mm 135 °F (57 °C) is Specified
Installation Wrench: Model D Sprinkler Wrench
Approval Type: Extended Coverage — Light Hazard Occupancy
Extended Coverage Horizontal Sidewall
Installation Data:
Temperature Sprinkler
Nominal Thread K Factor Sprinkler Approval Rating Identification
Orifice Size US Metric Height Organizations , oC Numbers (SIN)
%" (20mm) NPT (R 8.0 115.3 2.75" (70mm) 1,2,8 135 (5mm bulb) 57 R1762
155 (3mm bulb) 68
COVERAGE AREA
Max. Area Deflector to
Flow Rate Pressure Width x Length Ceiling Dimensions
(Min. - Max.)
gpm Umin psi bar ft. x ft. m x m
36 136.3 20.3 1,4 16 x 22 4.9 x 6.7 4 "(102mm) - 6 "(152mm)
39 147.6 23.8 1,6 16 x 24 4.9 x 7.3 4 "(102mm) - 6 "(152mm)
•
•
6.
Model F1 Recessed Extended Coverage Horizontal Sidewall Sprinkler
Deflector: EC -6
Glass Bulb: 3mm 155 °F (68 °C) Only
- Installation Wrench: Model GFR1 Sprinkler Wrench
Approval Type: Extended Coverage — Light Hazard Occupancy
(IOI.9mm r0 151.Immj
3 I `I COLLAR
.e "ft I ; '1' iMii 7p/r ACJASr
R , 15/16' DA 411E01511
_�� �, � ( .9.�, 1- - I'�UNIIIIIII 2 ins;
1 t J
Recessed Extended Coverage ,7
Horizontal Sidewall „,, ...
1m �
(nsmml (o
1 a /s” AWUS7Yn+r
(79.Im,)
") When installed directly into a tee, the escutcheon dimension's
adjustment will be reduced.
Installation Data:
Nominal Thread K Factor Sprinkler Approval Temperature Sprinkler
Rating identification
Orifice Size US Metric Height Organizations °F oC Numbers (SIN)
1 %2" (20mm) %" NPT (R 8.0 115.3 2.75" (70mm) 1,2,8 155 68 R1762
COVERAGE AREA
Max. Area Deflector to Ceiling
Flow Rate Pressure Width x Length Dimensions
(Min. - Max.)
gpm Umin psi bar ft. x ft. m x m
36 136.3 20.3 1,4 16 x 22 4.9 x 6.7 4 "(102mm) - 6 "(152mm)
39 147.6 23.8 1,6 16 x 24 4.9 x 7.3 4 "(102mm) - 6 "(152mm)
•
7.
r
Model F1 & F1 Recessed Sprinklers Maintenance
Application The Models F1 and F1 Recessed Sprinklers should
Model F1 and F1 Recessed sprinklers are used in fixed be inspected quarterly and the sprinkler system main-
fire protection systems: Wet, Dry, Deluge or Preaction. tained in accordance with NFPA 25. Do not clean sprin-
Care must exercised that the orifice size, temperature rat- cle with soap and water, ammonia any other
ing, deflector style and sprinkler type are in accordance cleaning fluid. Remove any spprinkler r which has been
with the latest published standards of the National Fire Pro- painted (other than factory applied) or damaged in any
tection Association or the approving Authority Having way. A stock of spare sprinklers should be maintained
Jurisdiction. to allow quick replacement of damaged or operated
sprinklers. Prior to installation, sprinklers should be
Installation maintained in the original cartons and packaging until
. Model F1 sprinklers are standard response sprinklers in- used to minimize the potential for damage to sprinklers
tended for installation as specified in NFPA 13. They must that would cause improper operation or non - operation.
also be installed with the Model D Sprinkler Wrench specifi-
. cally designed by Reliable for use with these sprinklers.
The Model F1 Recessed Sprinklers are to be installed Temperature Ratings
with a maximum recess of 3 /4 inch (19mm). The Model F1 Sprinlder Maximum Ambient
Escutcheon illustrated is the only recessed escutcheon to Classification Temperature Temperature Bulb
• be used with the Model F1 Pendent and EC Sprinklers. The °F °C °F °c Color
use of any other recessed escutcheon will void all approv- Ordinary 135 57 100 38 Orange
als and negate all warranties. When installing Model F1 Re- Ordinary 155 68 100 38 Red
• cessed Pendent, EC Pendent, and EC HSW Sprinklers, use Intermediate 175 79 150 66 Yellow
the Model GFR1 Sprinkler Wrench. Any other type of Intermediate 200 93 150 66 Green
wrench may damage theses sprinklers.
High (H (1) 286 141 225 107 Blue
Y g P Extra High 360 182 300 149 Mauve
Glass bulb sprinklers have orange covers to protect the
bulb during the installation process. REMOVE THIS PRO- '" Not Available For F1 Recessed
TECTION ONLY AFTER THE SYSTEM HAS BEEN HYDRO- Patents: U.S. Patent No. 6,374,920
STATICALLY TESTED AND, WHEN APPLICABLE, THE Applies to Model F1 Vertical Sidewall Sprinklers.
ESCUTCHEONS HAVE BEEN INSTALLED. RASCO
wrenches are designed to install sprinklers when covers Finishes (11
are in place.
Standard Finishes
Sprinkler Escutcheon
Bronze Brass
Chrome Chrome
Ordering Information White Polyester Coated' White Painted
Specify: Special Application Finishes
1. Sprinkler Model Sprinkler Escutcheon
2. Sprinkler Type Bright Brass """ Bright Brass
3. Orifice Size Back Plated Black Plated
Black Paint Black Paint
4. Deflector Type Off White ""°' Off White
5. Temperature Rating:
Satin Chrome "" Satin Chrome
Specify Bulb Size when ordering Wax Coated "' "
P g Wax Over Lead cm c "'61
Model F1 EC HSW Sprinkler.
6. Sprinkler Finish c" Other colors and finishes are available on special order.
Consult factory for details.
7. Escutcheon Finish (where applicable) (4 200 ° F (93 °C) maximum.
(') UL and ULC Listed, and NYC Approved Only.
I ' ) 155 °F to 200 °F (68 °C to 93 °C) ratings only.
(5' 286 °F (141 °C) Sprinklers may be coated for ambient conditions
not exceeding 150 °F (66 °C).
(6) LPC approved for 10mm and 15mm sprinklers only.
The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly
• qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries
Manufactured by
The Reliable Automatic Sprinlder Co., Inc. ma
•
Re Ilab ie (800) 431-1588 Sales Offices A spar
(800) 848-6051 Sales Fax Revision lines indicate updated or new data.
(914) 668-3470 Corporate Offices
• www.rellablesprinkler.com Internet Address EG printed in USA. 12/03 P/N 9999970011
0
-
o _
ia : cn iimi iii i d y isruaryc-Oir - • ,
... v i . -, , ,.. *Ai _.. 1 ., , ._
CV
- . " %II Firli taut iiiti
Seismic Are L � = 111 , I loos
. 4,,, , , 1" clearance must . a
�
Ai &') .-
z
be provided around � •
�i>fler Sae.... lP. Part M ear °tad* Elba .
�- the sprinkler.
Fl as 12 6814002100 4112 Chrome White
• A metal extension 681 1404.1 00 •5 - Chrome
6814041500 •5-112 White
must be used to 1 1 14022100 4-112 cwt.
14027200 4-1/2 Wh
maintain In the, fire r £4037200
}.� �}` CCP�ICIDH 80156 1 6814022100 4-1/1
*5-1/2 Chrome
Mee
Chrotae.
rating Ql ce��� • 6814021800 A-ltZ Whiite
6814032100 n4.12 Cluome .
•
/ �
}' : 6814533800 *5-112 White
c9 r. Available for = 5-1t2 inch (hamster me made to order =limey take up to 6 to 8 weeks.
N
Z..6 Costa= Col= e rtyclalespmmpdt Paraffic sCokcsasslana d Iamb rivissopts • AIIo�Sto4etch a
recessed & dam Aomspdgsue endforAmM�a Wan n
R o _ —s i.
cm 0 co concealed - . •
I CS
sprinklers. • • - _ _ . •
o
•
•