Loading...
Report „6 2a 002- I Advanced Security & Fire 2218 NE Sunrise Lane, Hillsboro OR 97124 503 -519 -4550 Fax 503- 640 -8311 CCB 152853 Fax To Person : Dennis Pagni Company : PacTrust Fax # : 503 -624 -7755 OSZ From: David Moravik Re: NFPA Fire Alarm Report. 94P 7 'c 7.--- Dennis, The attached is the NFPA fire alarm report required by the city of Tigard. Sincerely, David Moravik Advanced Security & Fire •d TTEB0b9EOS WtneJoW ptnea epb:BO LO SZ FeW • D o Record of Completion 2 m of Protected Property: / 9 e / Tic k e 14-y / C ; fifes tdress: / E� SD SZ 7 oc n d /91e e !) 1. p. of Protected Prop. (name/phone): A9 C- r/t u 67 -S43- D3- d - 7? sl7 / ithority Having Jurisdiction: / A f' / idress/Phone Number: I, 3 I S cS W /loll 8 Ivd. •=2 eQ 3 Type(s) of System or Service NFPA 72. Chapter 3 — Local • • if alarm is transmitted to location(s) off premises, fist where received: enir'91 3 ion C o rJ ' n 43D- .2$qG NFPA 72. Chapter 3 — Emergency VoiceJA Service Quantity of voice/alarm channels: e�� Single: Multiple: Quantity of speakers installed: Quantity of speaker zones: Quantity of telephones or telephone jacks included in system: NFPA 72, Chapter 4 — Auxiliary Indicate type of connection: Local energy: Shunt: Parana) telephone: • Location and telephone number for receipt of signals: C SM ( _st c 0909 , DR NFPA 72. Chapter 4 — Remote Station alarm: Sp ;. - l kler LUAfe' rlau) ) S,u D/ Vi91ve. - Superv . s / on e Supervisory: Eg Scr, ,i-e DS•) Pu /) S7 /37 - T"e NFPA 72. Chapter 4 — Proprietary If alarms are retransmitted to public fire service communications center or others, indicate location and telephone number of the organization receiving alarm: /VA Indicate how alarm is retransmitted: i3 6 1 / // // ll /� ; /4 D; 4-/e r Lv; 6 e l /u /A n NFPA 72. Chapter 4 — Central Station The Prime Contractor: c s f Central Station Location: / 19 c � dA - D R Figure 1 -7.2.1 Record or Completion. `afE NATIONAL FIRE ALARM CODE HANDBOOK p \ le ''i4/11 needs -7 /7,9 e oi ; ,,i 7 did 7"es lire //9 rc.- S' -�, 2-d — 1 TE130179E0S Itne.JoW ptne0 eT zBD LO S2 ReW 0 _ Chapter 1: Funeamentals of Fire Alarm Systems Means of transmission of signals from the protected premises to the central station: ' / McCulloh Multiplex Digital Alarm Communicator One-Way Rado Two-Way Radio ✓ Others C e /124 /i9 r BAG ALN90 Means of transmission of alarms to the public lire service communications center: (a) C r'A I 57 iGn ,gpe!'n 1-or (b) System Location: E. S 479 CA d A 1 01P Organization Name/Phone J R entative Name/Phone Installer Gr v/4n c d Sec urn / 7 .S lei re. Supplier ,.C:L/t1D J Iie {//On 7 we /1) Service Organization Location of Record (As -Built) Drawings: C.1 t y o 7,:_v9 and y g On Si f8.- Location of Owners Manuals: Dr) ,5:7 e 523, ,'9J v'9 r7 C ed Se Car : t,, 6 j: Pt':', Location of Test Reponss: /9 Cif / A contract, dated Z, ' / yy C c„.1.0.0 SP c u n / ]' y 53 lc; r L O dated .� . is in e rfC�t . �rtes<8 rtd in9perxrot ina�rdar , cewin�NFPAstand2rd ( s ) N a(s) . 2_ Record of System•Installation (RU out after installation is complete and Ong checked for opens. shoots. erational acceptance tee.) ground faults, and improper branching. but prior to conducting op This system installed in acconiance with the NFPA standards as shown below. was inspected by V !9 r �/ 7) D b /e, on _ S /� 02 includes the devices shown below. and has been in service since _5 . NFPA 72. Chapters 1 3 4 5 6 7 (circle all that apply) /NFPA 70. National Elecbical Code. Article 760 �/ Manufacturer's Instructions . Other specify): • Signed: • k_ ® Organization_ /at Record v/) n c e a S e. c U r "� . Dale: s a2 S/D � Record of System Operation All operational features and 1unc6ons of this system were tested by on S/7 /D 7 and found ig be operating property in accordance with the ✓ requirements of: NFPA 72. Chapters 1 3 4 5 6 7 (circle all that apply) V , NFPA 70. National Electrical Code. Article 760 1/ / Manufacturer's Instructions 1/ Other ): . Signed: `i i_ - ' - i Date: S G 7 OrganitaGon: �,9 C 71 14-5 f Figure 1 -7. .1 Continued NATIONAL FIRE ALARM CODE HANDBOOK a E'd 1 TE1310tr9EDS 11ineJoW PTABa eTb =60 LO SZ ReW 1 -7 Documentation 45 e. Alarm - Initiating Devices and Circuits (use blanks to indicate quantity of dn) • • MANUAL (a) / Manual Stations Noncoded. Activating Transmitters Coded (b) Combination Manual Fire Alarm and Guard's Tour Coded Stations AUTOMATIC . Coverage: Complete: Partial: (a) t Smoke Detectors ton _L_ Photo (b) Duct Detectors Ion Photo (c) Heat Detectors FT RR y Ff/RR RC o2 (d) Sprinkler Waterflow Switches: Transmitters Noncoded. Activating Coded (e) Other (fist): 5. Supervisory Signal - Initiating Devices and Circuits (use blanks to indicate quantity of devices) GUARD'S TOUR (a) Coded Stations . (b) Noncoded Stations. Activating Transmitters (c) Compulsory Guard Tour System Comprised of Transmitter Stations and Intermediate Stations NOTE: Combination devices recorded under 4(b) and 5(a). SPRINKLER SYSTEM (a) Coded Valve Supervisory Signaling Attachments Valve Supervisory Switches. Activating - Transmitters (b) Building Temperature Points (c) Site Water Temperature Points (d) Site Water Supply Level Points Electric Fire Pump: (e) Fire Pump Power (I) Are Pump Running (g) Phase Reversal Engine - Driven Fire Pump: (h) Selector in Auto Position (i) Engine or Control Panel Trouble (j) Fire Pump Running Engine -Driven Generator. (k) Selector in Auto Position - ( Control Panel Trouble (m) Transfer Switches (n) Engine Running • Other Supervisory Function(s) (specify): • Figure 1 -7.2.1 Continued NATIONAL FIRE ALARM CODE HANDBOOK b al T T E80179E0S )i t ne..loW p i net e T b= BD LO S2 ReW 46 Chapter 1: Fundamentals of Fire Alarm Systems • 6. Alarm Notification Appliances and Circuits Quantity of indicating appliance circuits connected to the system: Types and quantities of alarm indicating appliances installed: ( a) Bells Inch ( b) Speakers (c) � Homs ( d) Chimes ( e ) Other. • (I) ' Visual Signals Type: jj o C Nor r /,S7 y with audible w/o audible (g) Local Annunciator 7. Signaling Line Circuits Quantity and Style (see NFPA 72. Table 3-6) of signaling tine circuits connected to system: Quantity: am Style: 8. System Power Supplies L , (a) Primary (Main) :Norninal Voltage: "y Y Current Hating: � /9 m� Overcurrent Protection: Type: P TC Cu Location: Current Raring: _ -S �� 1�1i9X 3 /9 (b) Secondary (Standby): �y Storage Battery: Amp Hour Rating �. S X v2 � / cS ,9 i+, PS ) Calculated capacity to drive system. in hours: 24 60 Engine- driven generator dedicated to fire alarm system: Location of fuel storage: (c) Emergency or Standby System used as backup to Primary Power Supply. instead of using a Secondary Power Supply: Emergency System described in NFPA 70. Article 700 Legally Required Standby System described in NFPA 70. Article 701 Optional Standby System described in NFPA 70. Article 702. which also meets the performance requirements of Article 700 or 701 9. System Software (a) Operating System Software Revision Level(s): (b) Application Software Revision Level(s): • (c) Revision Completed by: (name) (firm) O. Comments: (signed) tor Central Station or Alarm S v i own c° (date) - S / / �.5 D 7 ervoa �%ompanY (title) / / (date) Figure 1 -7.21 Continued NATIONAL FIRE ALARM CODE HANDBOOK S ' °) T T EBOtr9E0S i ne ,loj.) p t neQ e T : g0 LO SZ ReW 1 -7 Docurfentation 47 Frequency of routine tests and inspections. if other than in accordance with th referenced NFPA Q u 1 i e r (_ x Ye r9 l)/ starndards(s). System deviations from the referenced NFPA standards) are: 6 nC ed Sec 4r ;7 - X T; P eS✓odeni 1/4 (signed) for Central Station or Atarm Service Corn y (tide) upon completion of the system(s) satisfactory test(s) witnessed (if required by the authority having jurisdiction): (date) (signed) for Central Station or Alamt Service Company () (date) Figure 1 -721 • 9' d T T Et30ia9EOS �{ t r e.lol l p i neQ LO SZ ReW