Correspondence &gyp (Pa tio2.3
A ill
r May 24, 2006 : -il'
CITY OF TIGARD
OREGON
Pac Trust
Dennis Pagni
15350 SW Sequoia Prkwy, suite 300
Portland, OR 97224
RE: SAFECO - REVIEW
Project Information
Building Permit BUP2006 -10023 Construction Type: 3B
Tenant Name: Safeco D, Occupancy Type B
Address: 16505 SW" Ave Stories: 2
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004
edition; and the State of Oregon Fire Code (OFC) 2004 edition. The submitted plans are approved .
subject to the following conditions.
1. The main exit shall be provided with signage indicating `°THIS DOOR MUST REMAIN
UNLOCKED DURING BUSINESS HOURS" Section 1008.1.8 OSSC
2. Exits and exit access doors shall be marked by an approved exit sign readily visible from any
direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases
where the exit or the path of egress travel is not immediately visible to the occupants.
1011.1 OSSC FYI Additional exit signs may be required by the city field inspector to dearly
• indicate the path of egress
3. All exit doors shall be openable from the inside without the use of a key or any special
knowledge or effort. 1008.1.8 OSSC
4. Exit signs shall be illuminated at all times and shall be provided with a second source of power that
will provide 1 1 /2 hours of illumination in case of primary power loss. 1006.3 OSSC FYI Additional
exit signs may be required by the city field inspector to clearly indicate the path of egress.
5. The means of egress shall be provided with illumination of not less than 1 foot candle at the floor
level anytime the building is occupied. The means of egress illumination shall be provided with a
second source of power in case of primary power loss. 1006.2 OSSC
6. Provide 2 -A rated fire extinguisher in the new area. The extinguisher shall be located so that no
usable space has a distance greater than 75 feet to the extinguisher. OFC 906.3
7. Floor drains shall not be located within the clear floor space at a lavatory, water closet, urinal, or
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
bathtub or shower. Floors shall not slope in excess of 1 unit vertical in 50 units horizontal (2-
percent slope). Floor drains shall comply with Section 1109.4.5 and be without abrupt changes of
level. Exception: Floor drains may be located within a clear floor space at a fixture provided the openings in the
drain aver shall not exceed 1/2 inch (12.7 mm) in any direction and the drain cover shall be no more than 1 18 inch
below the level of the surrounding finished floor surface. 1109.10.1 OSSC
8. Safety glazing including but not limited to: the following locations: Each unit of glazing shall
be permanently identified by the manufacturer. Sec. 2406. Some of these locations are as
follows:
a. Glazing in ingress and means of egress doors.
b. Glazing in an individual fixed or operable panel adjacent to a door where the nearest
vertical edge is within a 24" arc of the door in a closed position and whose bottom edge is
less than 60" above the floor or walking surface except when there is an intervening wall or
other permanent barrier between the door and the glazing.
9. Deferred submittals such as Truss Joist Shop Drawings, suspended ceiling system etc, will be
charged a deferred submittal fee based on the valuation of the portion of the work being deferred.
The minimum fee shall be $200.00. This fee is in addition to the project plan review fee based on the
total project value. OAR 918-050-0150 Deferred Items: None listed
NOT PART OF THIS REVIEW:
Fire Sprinklers, Fire Alarm, Mechanical System, Plumbing, Electrical
American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer,
Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the
structure. The City of Tigard reviews the plans and inspects the structure only for compliance with
Chapter 11 of the OSSC, which may not include all of the requirements of the ADA.
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be
maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout
all phases of construction. 106.3.1 OSSC
Certificate of Occupancy: No building or structure shall be used or occupied until the Building
Official has issued a certificate of occupancy 110.1 OSSC
Premises Identification: Approved numbers or addresses shall be provided for all new buildings in
such a position as to be plainly visible and legible from the street or road fronting the property.
When submitting revised drawings or additional information, please attach a copy of the enclosed City
of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and
processing the documents.
Respectfull
Val Henzel, Senior ' lans Examiner