Correspondence FILE COPY e 2
dii /axl1A1�� lV ��,rtf'k ' h
July 12, 2004
CITY OF TIGARD
OREGON
John H. Romisch
PacTrust
15350 SW Sequoia Parkway, Suite 300
Portland, OR 97224
RE: TENANT IMPROVEMENT
Building Permit: BUP2004 -00305 Occupancy Type: B /S2
Tenant Name: Ron's Hotel & Restaurant Service Construction Type: VN
Address: 16364 SW 72 Avenue Occupant Load: 18
Area: 7,500 Sq Ft Stories: 1
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC)
1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999
edition. The submitted plans are approved subject to the following conditions.
1. 2 x 12 Ceiling joist have been installed over the new interior partitions at Office 106
and Reception 104. The joist are not permitted to be used for storage.
2. Provide a permanent sign indicating "STORAGE NOT PERMITTED" in a clearly
visible location.
3. The means of egress shall be provided with illumination of not less than 1 foot candle
at the floor level anytime the building is occupied. 1003.2.9.2 OSSC
4. Provide 2 -A rated fire extinguishers so that no usable space has a distance greater
than 75 feet to the extinguisher. Standard 10 -1, Chapter 3 TVFR99 -01.
5. Deferred submittals such as Fire Sprinkler, Mechanical Systems, etc. will be charged
a deferred submittal fee based on the valuation of the portion of the work being
deferred. The minimum fee shall be $200.00. Deferred items;
• Fire Sprinklers
• Mechanical System
American with Disabilities Act (ADA): It shall be the responsibility of the Architect,
Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA
requirements for the structure. The City of Tigard reviews the plans and inspects the structure
only for compliance with Chapter 11 of the OSSC which may not include all of the
requirements of the ADA.
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
•
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall
be maintained on the jobsite. The plans shall be available to the Building Division inspectors
throughout all phases of construction. 106.4.2 OSSC
Certificate of Occupancy: No building or structure shall be used or occupied until the
Building Official has issued a certificate of occupancy 109.1 OSSC
Premises Identification: Approved numbers or addresses shall be provided for all new
buildings in such a position as to be plainly visible and legible from the street or road
fronting the property.
When submitting revised drawings or additional information, please attach a copy of the
enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of
Tigard in tracking and processing the documents.
Respect ly,
ria ' : lalock,
S- or Plans Examiner