Loading...
Plans . . . ... PORTLAND, ORE 97224 OCCUPANCY AREAS & LOADS: #3082 B 3,125 SF 31 OCC AR IN W. HANSON 1 624-6300 (PHONE) S -2 IN TERS T ( 624 -7755 (FAX) TOTAL 5,981 SF 37 OCC . AT 5 AMC , OREGON , .. r A BLDG. #: OPB I BLDG. #17 (1opb117) NUMBER OF EXITS REQUIRED �J a % �0 o 0 0 G V B S-2 1 EXITS o Z CONST. TYPE.: - E P,p er . J 9 6. g _•` i _ N - OF '� . L - ',,,,.,,,,,,, ,, •. EXIT f 290 , ' , � T Q THIS BUILDING HOUSES FIVE SEPERATE TENANTS INCLUDING THIS TENANT. THE PROD. #08130 �� to i(j I - O I 10- SAtEM EXISTING BUILDING IS A SINGLE STORY BUILDING OF 22,170 SF AND IS FULLY < " › - IR _ ° SPRINKLERED. THERE IS FRONTAGE ON ALL FOUR SIDES OF AT LEAST 80 FEET. �+L I �� _ = OR EGON ' _ ACTUAL BUILDING AREA TOTALS w o o _ - - ; BUSINESS B C 1 9 SF BUSINES I M i PARK I OC UPANCY = 4,2 0 = } 1 1 S -2 OC UPANCY = 7 780 SF > 6 CC c CC �, '_ .,..,.,,, TOTAL 22,170 SF n- Q ' r �7 \ /3:P1 l cL � O III-i / \c MIXED OCCUPANCY - NON-SEPERATED USES. (IBC 302.3.1) Z Q N N- a ALLOWABLE AREA (B USED AS MOST RESTRICTIVE FROM TABLE) D 0) o 1 0 ZED B 9 , 0 00 + 2 7,000 (300% SPRINKLER INCREASE) = 36,000 SF 5 ! LOCATION MAP z W I i SCALE I" =400' �0 N c � �l J 36,000 SF > 22,170 NON - SEPARATED USES ALLOWED Z Q z (O (p 5 F-I 1) FE) m SHEET INDEX: GENERAL NOTES rx Lot" °° CITY IX Ci_ LL OF TIGARD 1. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH THE '� d A -1 GENERAL INFORMATION LATEST EDITION OF THE INTERNATIONAL BUILDING CODE AS AMENDED BY Q A -2 BUILDING FLOOR PLAN `•" 1 DEFERRED / THE STATE OF OREGON AND ALL OTHER STATE OR LOCAL CODE Conditionally Approved...........„. [ I Ere sp ` REQUIREMENTS THAT APPLY. A -3 PARTITION & POWER PLAN See Lotter to Follow........„.,.„.. [ 1 Fire Alm A -4 CEILING PLAN t f Permit 44 • .r � . Mfxhenlcd 2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS A -5 DETAILS Plumbing SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND NOTIFY A -6 DETAILS i4d` f� Electrical OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK. By 4iiiiMa s < �C�/ •z_ puss Engineering — r °P Drawings .... 3. CONTRACTOR SHALL KEEP THE AREA OF WORK FREE OF GARBAGE AND Y W Other ...∎ DEBRIS ON A DAILY BASIS. - CONSTRUCTION LEGEND OFFICE COPY a- `n a Z CV 4. ALL GYPSUM BOARD TO BE A MINIMUM OF 5/8 "THICK VERTICALLY (A j N ATTACHED TO 3 1/2" METAL STUDS 24" O.C. WITH 1" TYPE S -12 SCREWS 12" LLI W Q m CC 1 EXISTING TO REMAIN RECESSED LIGHT (SEE PLAN FOR SPECS) O.C. UNLESS OTHERWISE NOTED. cc Z 0 LL c5 N = = = EXISTING TO BE REMOVED SU PPLY DIFFUSER - STANDARD KRUEGER PERFORATED 5. ACOUSTICAL CEILING SYSTEM IS EXISTING m N 0 I. FACE OR EQUIVALENT WITH ADJUSTABLE VANES p Z z z ® NEW STANDARD WALL O 6 . HVAC IS EXISTING. ADJUST / MODIFY DUCT WORK TO NEW WALL w g 0 . RETURN DUCT: PERFORATED FACE WITH NO METAL CONFIGURATION. W 0 0 1-- / 7 DUPLEX RECEPTACLE (SHINE) SHOWING THRU GRILL. a w 0 ' C O 40 FOURPLEX RECEPTACLE O THERMOSTAT - TOTAL -LINE SIGNATURE MODEL NO. 7. ADJUST EXISTING SPRINKLER SYSTEM PER NEW WALL CONFIGURATION. O 0 T a CPV220 ><, 2 X 4 FLUOR. FIXTURE /PARABOLIC LENSE 8. TELECOMMUNICATION SYSTEM BY TENANT. REVISION 1 EXHAUST FAN goVi 2 X 4 FLUOR. FIXTURE /PARABOLIC O -T -C , 3 9. CONTRACTOR TO PROVIDE AND INSTALL FIRE EXTINGUISHERS MIN 2A, 1 Illum/ LENSE /STEADY BURN BALLAST 2X2 . SPRINKLER HEAD; TYP• 10BC. 2 TILE .e 2 X 4 FLUOR. FIXTURE /ACRYLIC LENSE e EXIT SIGN (LED RED) Consuuction 1Yp0 10. ALL DIMENSIONS ARE TO FACE OF SHEETROCK UNLESS OTHERWISE r Rated Corridor NOTED. DATE: 1 /30/08 I� i l c cF L FLUOR. ® FIRE EXTINGUISHER 76":S PERMIT /BID SET II 2 6, . Gr....n. ib tO O O CI_______7.-6 000 O r 20� -0" sly I0� 25' z 1 -- - O _ 1 1 co b z 1 \ - - 0 1 1 a e I I = 0 I _ _ 1 O C 0 1. Z o _ .O ; ID . r 1 ._ I' • 1 ` - - - -J 1 - 0 l 1 1 I -j11 I 0 I 114, I I r _ JI - - -j 4 1 ,T, I I I Z fli 3 7 , bii 1 .: '� 1 I I o 1 1 -- a I Z L. I N 1-4 0 I V O m 0 N 1 SPACE FOR: MARTIN HANSON ARCHITECT 1 ys j `� K m OREGON AIR REPS PORTLAND, OR 97224 �- �y i t = -` 0 PH (503) 624 -6300 CO W Z FX (503) 624 -7755 - 03 O OREGON BUSINESS PARK I Oo O Po z w co 15954 SW 72ND AVENUE BUILDING #17 (PTR #117) 0 �� � y Z z PORTLAND, OR 97224 A P�4dUBT PROPERTY q. ilDr0 I '.,' r� #3082 • MARTIN W. HANSON .., 4 cp. CIAO . ' , OREGON 102 -'= O CONF �?'� O Og� 101 1 � . § ENTRY ' PROJ. #08130 I -8 1-8-115- 1 0 T es DOCK HIGH 0 t 107 x cc DOOR ■ OPEN OFFICE a a 13--1 f= _L--- WORK aa• -r Cr a N r 1 -G I z Q N T © .— p o O6 oto a Tar 103 z 3� P N. z I. r 0- c4 O CIRC. � ■ Z z ow 38• ' • I al' '' 4 •...* c cc 6 In 1 05 1 CY � 1- io L S tz WOMEN ]j MEN EXIT PATH = 85' 10 i ^ x ► I. .T-CL LL L L 4 ' . i l) 10'-1 1/2' T 1 0 1 1 4 3/4 c CI 111 bm• I 109 I ' F ' WAREHOUSE • BREAK I 41 q Q5 3' x9' 11► iI _ 4 ®,- 108 1 108B Y w ® 4' x 9' OFF. ►; OFF. cc ■ ■ co az� C O" - ; U) > N ® ® _ 11� • CC w o rn 1,__13 3 O z 0 0 O ® CONSTRUCTION NOTES: Q 5 N O > - I 1 SOUND 05 4' x 9 S U REMOVE EXISTING PARTITION z z 0 > Z --) `► I I ► O2 REMOVE EXISTING DOOR/FRAME w O 0 110 1 - DISPOSE OF U W Cl in 6 ~ — — — n _ _ — _ OPEN OFFICE / O REMOVE EXISTING LOW WALL 0 - DISPOSE OF. +� 0 O T n. RELOCATE EXISTING ELECTRICAL 4 NEW BUILDING STANDARD DEVICES THAT CONFLICT WITH NEW O REVISION PARTITION LOCATIONS. ADD NEW PARTITION TO CEILING. WHERE SHOWN I / $* 1 , O5 NEW BUILDING DOOR / FRAME -SIZE AS NOTED. PAINT ONLY THOSE WALLS AFFECTED Z. BY DEMO. / NEW CONSTRUCTION. - • - .. , . © NEW BUILDING STANDARD • -> / RECITE. DATE: 1/30/08 PARTITION AND POWER PLAN - 0 NEW DRIVE -IN RAMP W/ SIDE PERMIT /BID SET ,, RETAINING WALLS / METAL R > < I I >< I_ #3082 .Cj� 9 a ' RTIN W. HANSON C i y I I 1 X > I X '= zf 1 CLACKA . , OREGON , . `' ® • p � � 1 4 ' O F Ogg • >C — = PROJ. #08130 • >< >< — 1 .- Y .-- .. e ----- _ , . o co o R i 6 DOCK HIGH - X • /R U o� _. • — — — • _ �� a a GRID MAIN \ A • T 1 >< ^ Q N a 1 ./ � z r a W P 0 z ►liliuu • / 1 0 (D r Im ><.. x � o NN i I oo ° ° ...... .: ' .1 :: '' :9 >< au 4 / 0 A 1 1 j _ r ________, :jir __,___. . . . 1 ._.). ,....__„J - 1 ><Kri 2><. U) CL Y CC w > _ oC w orn cC RJ Q D�O 1 i I I >< _ ° a. z O (-) Z CI3 a- CEILING NOTES: v w -I in cc 4 - — — — — — — — EXISTING CEILING GRID & LIGHTS TO a 0 REMAIN. � 0 0 r a. REVISION RELOCATE OR ADD HVAC / FIRE SPRINKLER HEADS AS SHOWN FOR NEW WALL N X X CONFIGURATION. 1. 7-777 NEW / RELOCATED CEILING FIXTURE REFLECTED CEILING PLAN 4..z.,., (HVAC OR LIGHTING). 2. . .. " SCALE 1/8" = 1'70" DATE: 1/30/08 PERMIT /BID SET © \ WITHOUT INTERSECTING WALLS ) #3082 ' TI W. HANSON '� A -5 \ ----, y k- BLOCKING TYP. @ FASTENING POINTS ROOK OF DECK BEAM cp CIACKA AS, OREGON ~"""" " """' """ ^ ''" "" ' EXISTING SUSPENDED CEILING � � 4; \ II!, / REVE HEADER RECESSED J OF O g SUSPENDED CLG ASSEMBLY PROD. #08130 F U 3 -5/8" MTL. STUDS @ 24" O.C. 1 , 4 5° 0 r 5/8" GYP. BRD. BOTH SIDES T :,:' !Fir' CENTER LINE OF STUD IV I L I MI I. W __ x } 2 0 GA 3 5/8° METAL STUD BRACING V Fi•I a CC Q TO ROOF STRUCTURE AT 10' O" ' d 0 RACO TOP OC W/ (2) #8 SHEET ME _ TRACK w/ RACO SCREWS AT EA CH END. B RACING Z r a © BLACK REVEAL, TO BE PRO WHER DISTANCE O tc) ('3 A -5 4" RUBBER BASE -TYP. TYP EA SIDE BE TWEEN PERPENDICULAR INTERSECT (� 1 N- Z F WALLS O R HOR BRACING W ° ' I p WITH I , POWD R V AN HORSS AT 24" .C. ATTACH FINISH FLOOR (n d BETWEEN WALLS EXCEEDS 12' -0° OC Z z I ' I1 m .. ffilill el TYPICAL WALL SECTION 3 WALL BRACING DETAIL 2O = SCALE 1" = 1'-O" T a x 4 A -5 SCALE 3" = 1' -0" Al • g o PP TYPICAL STUD 2 0' (--) 1' 11' — • • Y W o / PROVIDE HC SIGNAGE FOR ALL NEW AND Q Q - EXISTING HC RR'S z KROY #2835207 BLACK (MEN) IZ W N I 0 at60100 • 1 KROY #2835209 BLACK WOMEN) LLI W Q N TYPICAL TRACK w Z [ CC Z p INSTALL STUDS WITH SAME o o ° Q D N 0 0 DIMENSION (10° MIN.) FOR Q " I " ADDITIONAL SWITCH r PIP' c, ci a S' (GANGLOCA11ON z m p 0 9 cc cc BRIDGING ALIGNMENT ° z ° "' LL I p O Z w ° � � W CD c' • w v' O o1-a POWDER DRIVEN 8° 20" 8' cp ANCHORS AT 24' 0.C. a • \ • ELECTRICAL REVISION 1° 40 0 / OR J -BOX w 6 a , J- „ 1. ( 1 ) #10 -16 SCREW 4 C o Z PER STUD FLANGE ' • ❑ 1 o w o 2. 0 CD U NDERCUT DOOR AS : •, o �, -. M REQUIRED TO CLEAR DATE: 1/30/08 FLOOR FINISH • • ._ PERMIT /BID SET '` %A /A1 1 MAC 1"11 - T A 11 /7\ BA, I 1 K IT1 N I/1 I IrI e ItF #3082 N.."..7 RTI W. HANSON j r _§ 11 _ . CLACKAMAS, OREGON ,.. INSTALL 36' HIGH HAND '• RAILING ON TOP OF RET. WELD WALL ATTACH WITH WEL • PLATES _.,...--- PROJ. #08130 (2) #4 CONTIN - • a • .,... • -• • -; ..• .' I c.) CONC SLAB BROOM FINISHED . s :. • . • . 1 W 0 • ID E'm #4@12'H - ' • co R ` 1-1 • • •• I 1■1 Z • 4-■ cc = • #4@12'V • CO • * GRAVEL FILL 1 . 1 • . . . #4 @ 12' ---............... \ < c\I ; a ( 3 ) . . 4 • . 1 -,.• 7 S "53 © o 6 8 2 o r \ cin cc co N z EXIST. A.C. o (._,.. / ASPHALT ._ — N-N- _1 I. r---....,....,... I-Er #4 REBAR 8" INTO EXIST 4' 0.C. W - CO 0 D Z z 03 1.—• co cl_18 E L' g Lo cc SS 4t CI) 0 1 X LC1 a- CI- LL 44 1 RAMP wALL SECTION ik A-5 SCALE 1/2" = wr i 1/2" PAINTED —..........................__, TUBE STEEL --..."-----........."----- --"----"""--"------"""""--"----"""""---""""""--"-"""----""--- 11 Y w CC D < Z •:1 Cr 11 w c \I 1 '-0" CL w > cv LI OC w a) 0 m 1 '-o L " Cr — Z (n N o m 0 CONC. SLAB . • • ....::. .:,.:. .:!...;;;...1:4... ", :•.4; - ‘..-. . Z Z BROOM FINISHED : O 0 6 w .5 co .i. . ... .. : i • , . :. .. .i.• 4 :. '' . '-' .7 -"...:!.-:!.:•-:: ....:': .:'. 1 ::: 1 ! •, : :.-1 ,...!•;' ' -,-! : ..'' .• .,.. 4•• w CD cp 't . .. u U — I W L a ( 3 C C . .. .. . • • .. . • < CC CC 10 • .. • • • • • • . • • • . . .. . • . .. . : : . .: 7: ;: . i ' t ; '•-• ..i.:.."::- ....::.....;:,•-: • l ' ': i .. ; • : • .. C21 0 0 1- a REVISION . . . . .• , . • • : cn . . .. .. _ . . • . . • GRAVEL FILL : . . . . . ' .sr. ;:.• .::•;•-....:.:'.. t.; ...::"..: !:'!..:.:....,. -. ,...:. .. .. .. . .. . . • . • . . • . ... . . .. . - i! .--:;-.:::; .q.::: :.• ...: , -:.• ,. , ; * 4, —co .•.. • . . .. :. . • . . • •• . . . .. . . ... . . . . 1. . . •. . • . • 2. . .. 4 a-O- 9.--o" /- / — DATE: 1/30/08 • 17 EXISTING ASPHALT PERMIT/BID SET 24-0 " • --,, c - 9 .- DRIVE—IN RA MP CROSS SECTION