Loading...
Permit CITY OF TIGARD ELECTRICAL PERMIT PERMIT #: ELC2001 -00187 L,`�' is DEVELOPMENT SERVICES DATE ISSUED: 4/13/01 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 PARCEL: 2S112DC -00100 SITE ADDRESS: 15705 SW 72ND AVE SUBDIVISION: OREGON BUS. PARK III ZONING: I -L BLOCK: LOT : 002 JURISDICTION: TIG Proiect Description: Replace 300A service with 600A Job No. 20245 RESIDENTIAL UNIT TEMP SRVC /FEEDERS MISCELLANEOUS 1000 SF OR LESS: 0 - 200 amp: PUMP /IRRIGATION: EACH ADD'L 500SF: 201 - 400 amp: SIGN /OUT LINE LTG: LIMITED ENERGY: 401 - 600 amp: SIGNAUPANEL: MANF HMI SVCI FDR: 601 +amps -1000 volts: MINOR LABEL (10): SERVICE /FEEDER BRANCH CIRCUITS ADD'L INSPECTIONS 0 - 200 amp: 1 W /SERVICE OR FEEDER: PER INSPECTION: 201 - 400 amp: 1 1st W/O SRVC OR FDR: PER HOUR: 401 - 600 amp: 1 EA ADD'L BRNCH CIRC: IN PLANT: 601 - 1000 amp: PLAN REVIEW SECTION 1000+ amp/volt: > =4 RES UNITS: > 600 VOLT NOMINAL: Reconnect only: SVC /FDR >= 225 AMPS: CLASS AREA/SPEC OCC: Owner: Contractor: PACIFIC REALTY ASSOCIATES CAPITOL ELECTRIC CO INC 15350 SW SEQUOIA PKWY #300 -WMI 12810 NE AIRPORT WAY PORTLAND, OR 97224 UNIT 1 PORTLAND, OR 97230 Phone: Phone: 255 -9488 Reg #: LIC 048748 SUP 3132S ELE 26 -496C FEES Required Inspections Type By Date Amount Receipt Elect'I Service PRMT CTR 4/11/01 $347.75 2720010000( Elect'I Final 5PCT CTR 4/11/01 $27.82 2720010000( PLCK CTR 4/11/01 $86.94 2720010000( Total $462.51 This Permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0080. You may obtain copies of these rules or direct questions to OUNC at (503) 246 -1987. • PERMITTEE'S SIGNATURE ISSUED B : ^ .ik / C4 OWNER INSTALLATION ONLY The installation is being made on property I own which is not intended for sale, lease, or rent. OWNER'S SIGNATURE: DATE: CONTRACTOR INSTALLATION ONLY 6a� SIGNATURE OF SUPR. ELEC'N: ✓`Q -Q-e _1 ( 4 a -✓`- DATE: LICENSE NO: 3/ 3 2-, 5 Call 639 -4175 by 7:OOpm for an inspection the next business day - Electrical Permit Application OFFICE lisi ONLY' � Date received: - •-pl Permit no.:ELd3ce /.00 Project/appl. no.: Expire date: 1 City of Tigard Date issued: By: Receipt no.: CITY OF TIGARD Address: 13125 SW HALL BLVD, TIGARD, OR 97223 Case file no.: Payment type: Phone: (503) 639-4171 Fax (503) 598 -1960 Land use approval: IN l'I•: OF I'I :I0I11' ❑ 1 & 2 family dewlling or accessory ❑ Commercial/industrial ❑ Multi - family ❑ Tenant improvement ❑ New construction 3 ❑ Addition/alteration/replacement ❑ Other: ❑ Partial Job address: W 72 ND City: TIGARD OR Bldg. No.: Suite no.: Tax map /tax lot/account no.: Lot: (Block: N/A (Subdivision: Project name TETRA PLASTICS 'Description and location of work on premises: REPLACE 3000A SERVICE WITH 600 AMP Estimated date of completion/inspection: Job no: 20245 Fee Max. Business Name: Capitol Electric Co., Inc. Description Qty. (ea.) Total no. Insp Address: 12810 NE Airport Way New residential - single or multi- family per City: Portland State: OR ZIP: 97230 -1029 dwelling unit. Includes attached garage. Phone: 503 - 255 -9488 (Fax: 255 -9488 IE -mail: darrell @cepdx.com Service included: CCB no.: 48748 'Elec. bus. lic.no: 26 -496C 1000 sq, ft, or less $ 145.15 4 e tro tics t .: N/A Each additional 500 sq. ft. or portion thereof S 33.40 t A (('t 4/9/2001 Limited energy residential $ 75.00 2 Signature of supervising ale 'c'an (required) Date Limited energy, non - residential S 45.00 2 Sup. elect. name (print): Darrell McNeel License no.: 3132 - Each manufactured home or modular dwelling PI.OFF,I lYO1WNI :R Service and/or feeder $ 90.90 2 Name (print): Services or feeders - installation, Mailing address: alteration or relocation: City: I State: IZIP: 200 amps or less 1 $ 80.30 80.30 2 Phone: Fax: IE -mail: 201 amps to 400 amps 1 $ 106.85 106.85 2 Owner installation: The installation is being made on property I own 401 amps to 600 amps 1 $ 160.60 160.60 2 which is not intended for sale, lease, rent, or exchange according to 601 amps to 1000 amps $ 240.60 2 ORS 447, 455, 479, 670, 701. Over 1000 amps or volts $ 454.65 2 Owner's signature: Date: Reconnect only $ 66.85 I I• :NCI : N I:4 :It Temporary services or feeders - Name: installation, alterations, or relocation: Address: 200 amps or Tess $ 66.85 2 City: State: ZIP: 201 amps to 400 amps $ 100.30 2 Phone: Fax: E -mail: 401 amps to 600 amps S 133.75 2 1'1,■N REVIEW (Pleas check all !hat apply) Branch circuits - new, alteration, ❑ Service over 225 amps - commercial ❑ Health-care facility or extension per panel: ❑ Service over 320 amps -rating of l &2 ❑ Hazardous location A. Fee for branch circuits with purchase of family dwellings ❑ Building over 10,000 square ft. four or service or feeder fee, each branch circuit $ 6.65 2 ❑ System over 600 volts nominal more residential units in one structure B. Fee for branch circuits without purchase ❑ Building over three stories ❑ Feeders, 400 amps or more of service or feeder fee, first branch circuit: $ 46.85 2 ❑ Occupant load over 99 persons ❑ Manufactures structures or RV Park Each additional branch circuit: $ 6.65 ❑ Egress/lighting plan ❑ Other: Misc. (Service or feeder not included): Submit 3 sets of plans with any of the above. Each pump or irrigation circle $ 53.40 2 The above are not applicable to temporary construction service. Each sign or outline lighting $ 53.40 2 Signal circuit(s) or a limited energy panel, alteration, or extension' _ $ 75.00 2 °Description: Each additional inspectionover th allowable in any of the above: Per inspection I I $ 62.50 I I Investigation fee Other ❑ Visa ❑ MasterCard Permit fee $ 347.75 Credit card number: / / Notice: this permit application Plan review ( 25% ) $ $86.94 Ex expires if a permit is not obtained State Surcharge 8% ) $ 27.82 Name of cardholder as shown on credit card $ withing 180 days after it has been TOTAL $ 462.51 Cardholder signature Amount accepted as complete. APR -09 -2001 13:12 FROM: PGE COYOTE SPRINGS 5414812741 TO:5032551966 PAGE:02 Portland Gotland Electrk COttlpelly MEMORANDUM 04/09/01 X TO: CONTACT: RANDY AT CAPITOL ELECTRIC PHONE: 503 - 255 -9488 CUSTOMER NAME: TETRA PLASTICS INC. ADDRESS: 15605 SW 72ND AVE TIGARD FROM: PGE ENGR MILO STARR 503 - 570 -4414 SUBJECT: 3 -PHASE SECONDARY FAULT CURRENT (RMSZ — TRANSFORMER DATA _ XFMR Impedance ( %): 1.4 % RADIAL NETWORK TRANSFORMER SIZE: 500 KVA XFMR ? No Secondary VOLTAGE (L to k): 480 v WYE ..... . ' • UL :. - ►;,-.o a ;8 CO DA: • 1 : 1 ti 444: R re 1,:ENO'T1i. • ' #•41 I WI , .:� •� �� REsI�• • ,!!(t 350 QX 040 BARE Res$sfancs 'Rt ; "0:00 •CihintlJ100Q' ; seccnarl',Re''nce,:' , .. 00b' VAULT ( or Pole) --> PANEL SECONDARY (or Svc Drop) Service Wire LENGTH: 90 Feet WIRE SIZE Number of Service RUNS: 3. Runs) of: 360 QX Service WIRE Resistance R: 0.0600 Ohms/1000 Service WIRE Reactance X: 0.0330 Ohms/1000' • • • FAULT CURRENT: 31,382 Amps . • (or SHORT CIRCUIT' CURRENT) RNIS Symmetrical (or INTERRUPTING CURRENT) • - X .over R ratio: 1.5748. T.. • loto Mr Wayne Amundson Cent/Wed to Excel by Allen .Dell. OF-ST Consult. 1 1fl00 CITY OF TIGARD BUILDING INSPECTION DIVISION 24 -Hoer Inspection Line: 639 -4175 Business Line: 639 -4171 MST s BUP • Date Requested AM PM BLD Location /5 7 S S 72-•- Suite MEC Contact Person '"7 Ph 3 3 - Z t fl PLM Contractor r,/1, ?�l/ / Ph SWR BUILDING ✓ Tenant/Owner /./A Se G�� w�--�a /04 �. ELC W-'0/8 7 Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Sf..31 , 1r--r ,) Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof / A/� Misc: C� Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam • Rough In Gas Line Smoke Dampers Final PASS PART FAIL 4 0xx•3?:7IN • Servi % Mg In UG /Slab Low Voltage Fire rm fC PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain 1 ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin [ 1 Please call for reinspection RE: 1 ] Unable to inspect - no access Fire Supply Line ADA Approach /Sidewalk Date OC/C/ Inspector Ext Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site.