January 22, 2003
T0302349.CTI
Permit No.: BUP2003 -00003
FIELD INSPECTION REPORT
DATES COVERED: January 13, 2003
PROJECT: Nike — Golf Assembly
ADDRESS: 15705 SW 72 Ave — Tigard, OR
INSPECTOR: S. Fox — COP#597, OBOA #177, ICBO #0840028 -88, ACI #936672
01- 13 -03: As requested by Howard S Wright, CTI representative was on site to inspect epoxy
procedures and the following was noted:
Contractor epoxied (4) 7/8" x 9" all thread rods for the hardy shear panel holddowns. Two rods
were installed at each ends.
Holes were drilled 1" x 5 1 /2 ", and were thoroughly cleaned. Epcon C6 epoxy was injected and
all thread rods were installed in conformance with approved project drawings.
Epcon C6 was used in conformance with ICBO ER -4285. Epoxy had batch # EONR 70437 with
expiration date of 1/2004.
*** CHECK ONE BOX ONLY*" YES NO
1. This is a preliminary inspection only. — OR — ❑
2. The work inspected conforms to acceptance criteria listed above. If "No," the portions of the
work that are non - conforming items are clearly stated above and will be added to the NCL.
Remaining portions of the work, which are not preliminary in nature, are to be considered as ® ❑
conforming.
Our reports pertain to the materials inspected/tested only. Information contained herein is not to
be reproduced, except in full, without prior authorization from this office.
If there are any further questions regarding this matter, please do not hesitate to contact this
office.
Respectfully submitted,
CARLSON TESTING, INC.
F. Hietpas
Quality Assurance Manager ,
SF /ck
cc: Nike Retail Services Inc — Eric Sorensen
City of Tigard Building Dept
VLMK — Trent Nagel
Ralston Architects — Erich Karp
01 -13-03 fr.doc I
Main Office Salem Office Bend Office
• P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918
Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708
Carlson Testing Inc. Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155
FAX (503) 684 -0954 FAX (503) 589 -1309 FAX (541) 330 -9163
Special Inspection
FINAL SUMMARY LETTER
February 7, 2003
T0302349
FILE
City of Tigard COp Y
13125 SW Hall Blvd.,
Tigard, OR 97223 -8199
Attn: Building Department
Re: Nike — Golf Assembly
15705 SW 72 Ave — Tigard, OR
Permit No.: BUP2003 -00003
Dear Sir or Madam:
This is to certify that in accordance with Section 1701 of the Uniform Building Code and Chapter 24.20,
Title 24, we have performed special inspection of the following item(s) per our inspection reports only:
Installation of Epoxy Anchors
All inspections and tests were performed and reported according to the requirements of Project Documents
and, to the best of our knowledge, the work was in conformance with the approved plans and
specifications, approved change orders and applicable workmanship provisions of the State Building Code
and Standards, as well as the structural engineer's design changes, approvals and verbal instructions.
Our reports pertain to the material tested /inspected only. Information contained herein is not to be
reproduced, except in full, without prior authorization from this office.
If there are any further questions regarding this matter, please do not hesitate to contact this office.
Respe r ully submitted,
CARL :ON TESTING, INC.
Ja7 F. Hietpas
Q , ality Assurance Manager
I H/Is
cc: Nike Retail Services. Inc — Eric Sorensen
VLMK — Trent Nagel
Ralston Architects — Erich Karp
P:\WORD%REPORTSWtNLTR \709302349
JAN 17 '03 02: 47PM VLMK ENGINEERS P.1 /1
CONSULTING
P 503222.4453
ENGINEERS F 503.248.9263
E vlmk @vlmk.com
3933 SW Kelly Avenue • Portland • Oregon 97201 -4393 1N www.vlmk.com
FIELD REPORT
Date: January 13, 2003 Job No 202492
Project: Nike Golf - Dryer Room Permit No:
13 Address: '6SW 72nd Ave Contractor: Howard S. Wright
Location: Tigard, Oregon Owner:
Weather: Light rain TemplTime: Approx. 50 at 2:30 pm
Present at Site: Steve Harding, Howard S. Wright; Trent Nagele, VLMK Consulting
Engineers
TO: Kimmo Akerblom, Ralston Architects
A structural observation visit was made to review framing of the new dryer room. This
room is a rectangular- shaped room approximately 10 feet wide with doors on each end.
Framing of the room is cold formed metal studs and joists.
At the time of my visit, rough framing of the room was complete. Sheathing had been
applied to the top of the ceiling joists and along the long sides of the room. Hardy
panels had been installed on each end of the room. The top mechanical unit had not
yet been placed.
Construction appeared to be in good order and per plans and specifications.
Should you have any questions or concerns, please do not hesitate to contact me.
Submitted By:
22t0e&
Trent C. Nagele, P.E., S.E.
VLMK Consulting Engineers
cc: Eric Sorenson, Nike
Steve Harding, Howard S. Wright
Travis Lawson, Howard S. Wright
City of Tigard
TCN:jjs
1 Structural Engineering • Civil Engineering • Industrial Engineering • Planning • Studies / Evaluations • Entitlement
K:Construction Docs'Field ReportsWfke Golf Dryer Room 1- 13- 03.doc