Loading...
Plans 1 5.)e -2440 Lt5 'City of Tigard, Oregon • 13125 SW Ha11 Blvd. • Tigard, OR 97223 • January 9, 2007 1. 1111 T I GARD Nike Golf Lab co 15705 SW 72n Ave Tigard, OR 97223 RE: NIKE GOLF BALL LAB - REQUEST FOR ALT MATERIALS & METHODS FOR PRE -FAB WALL PANELS FOR - PERMIT NO.: BUP2006-00583 Thank you for your submitted request. In review of your submitted request dated December 26, 2006, requesting to utilize section 104.10 of the (OSSC) Oregon Structural Specialty Code. You request the use of pre - manufactured wall panel provided by Porta -Fab Corporation consists of (2) layers of gyp board with a 2" polystyrene core. `The building official shall have the authority to ender interpretations of this code and to adopt policies and procedures in onler to clarify the application of its provisions. Such interpretations, pacies and procedures shall be in comp with the intent and purpose of this code. Such polices and procedures shall not have the effect of waiving requirements specifically provided for in this code." The evidence submitted for review was the wall panel assembly test results by Factory Mutual in accordance with the ASTM -84 Fire Test Method. See "Test 1" in the attached Factory Mutual test report This test demonstrates compliance with OSSC Code section 2603.3 " Surface - burning Characteristics ". The tested panel assembly had a Flame Spread rating of 5 which is under the allowable limit of 75 indicated in Section 2603.3 and a Smoke Density rating of 20 under the allowable limit of 450 indicated in Section 2603.3. RESPONSE This test demonstrates compliance with OSSC Code section 2603.3 "Surface- burning characteristics ". The tested panel assembly had a Flame Spread rating of 5 which is under the allowable limit of 75 indicated in Section 2603.3 and a Smoke Density rating of 20 under the allowable limit of 450 indicated in Section 2603.3. In closing, the proposed design is satisfactory and complies with the intent of the provisions of this code, and that the material, method or work offered is, for the purpose intended, at least the equivalent of that prescribed in this code in quality, strength, effectiveness, fire resistance, durability and safety." This approval is a site specific approval an not carry over to any other site. Respectfully Brian B ck, Ci Tigard B • ing Official Cc: Eric Sorensen Director of Corporate Architecture File Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772 669 2cc: .�Gs • � c 10 • J • . � J December 26, 2006 1 1.1 / 43 City of Tigard Building Department Attn: Brian Blalock 13125 SW Hall Blvd Tigard, OR. 97223 RE: NIKE GOLF BALL LAB - REQUEST FOR ALT MATERIALS & METHODS FOR PRE -FAB WALL PANEL PERMIT NO.: BUP2006 -00583 • Dear Mr. Blalock; Per our phone conversation on December 13th and at the request of Val Henzel I am requesting approval, as allowed under section 104.10 "Alternative Materials, Design and Methods ", of the pre- manufactured wall panel used in the assembly of the modular room specified on our permit drawings for the Nike Golf Ball Lab submitted to the City of Tigard on 12/13/06. The pre- manufactured wall panel provided by Porta -Fab Corporation consists of (2) layers of ' /2" gyp. bd with a 2" polystyrene core. The panel does not contain any electrical conduit or devices. All electrical conduit, outlets and switches are contained within a vertical structural column and are completely independent of the pre - manufactured wall panel. The wall panel assembly has been tested by Factory Mutual in accordance with the ASTM -84 Fire Test Method. See "Test 1" in the attached Factory Mutual test report. This test demonstrates compliance with OSSSC Code section 2603.3 "Surface- burning Characteristics ". The tested panel assembly had a Flame Spread rating of 5 which is under the allowable limit of 75 indicated in Section 2603.3 and a Smoke Density rating of 20 under the allowable limit of 450 indicated in Section 2603.3. Based on the information provided above we would like to request your approval of this pre - manufactured wall panel assembly for use in our project. Thank you for your consideration of our request and please call me at 780 -4293 should you have any questions. Respectfully, Eric Sorensen Director of Corporate Architecture NIKE, INC. Cc: Val Henzel, City of Tigard Lance Troutman, SSI Schaefer Systems International Inc. NIKE, INC. ONE BOWERMAN DRIVE BEAVERTON, OREGON 97005.6453 T:503.671.6453 F:503.671.6300 NIKE.COM