Loading...
Correspondence Lip ° 6 0 ` /. CO OK( 4 I e tRpi\I /Fz-L-E-I VI (-(0 2t 6 971-o541 C (1AP r ji) r - fJ, -G' //iaaiirA�ij + December 10, 1997 � � CITY OF TIGARD Bruce Stock OREGON Stock and Associates 82 University Street Seattle, WA 98101 Re: Nike Tetra "Fire Alarm" 15705 SW 72nd Avenue PC# 49c BUP# 96 -0255 Enclosed with this letter is a copy of requirements needed to complete the plan review for the proposed alarm system. I am aware that a system has been installed on site and most likely does not meet the coverage stipulated in that May 6, 1996 letter addressed to Bruce Stock from David Scott, City of Tigard Building Official. In that letter an automatic fire alarm system was required thoughout the building. Total coverage is defined in the Uniform Fire Code, Section 2 -7.4. Please address this matter immediately as I have had a recent inquiry by Nike wanting to do additional work needing a permit at this site. Until this situation has been resolved we shall reserve processing all future applications. Sincerely, Jim Funk Plans Examiner Enclosure c: Howard Wright Construction Nike - Tetra PO Box 3764 One Bowerman Drive Portland, OR 97024 Beaverton, OR 97005 I:YiywMsitnfl.0ot 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Ma;;-10 -96 05:21P Stock&Assoc /R.Bauch&Assoc (206) 623 0160 P.02 •v• ow 1 4.414 11 0 I2M7 CITY OF ?IGARD `� '^ ' 411002.'003 Commarcla[6uiiding Permit Aoolicatioa City of marl S/ / SW Nall Blvd P A , Afrr Miami, OR 97223 (6013) 039 -4171 Jolted, Aft 's,: / 4 7e2 S Ski 12"D 4vt 54' C. , 1 Tansnt A// -iE �' iuJb s • •. , ..-,. - - ., .. , ,a•... 41"ia•, J ' / o00 . :x-- : :._ge e s m :� ; ' .. •.'• SY' 1i1 -s :t C ear .. n rid Pe4 tiG S Owner: _ : .0:o, ttle: ;OPT- ' • P� • Address: 1# &(44u/ F, re.... j r i i,. ? =4= : :Sw ` *i ;• +: .� . ' .: p '1'�GlS�" fi: e#44 10(03 i ISI 0 4 111 , ; ...1,ir ...i.;::: A .< „if- .,:: 'i ,; . Phone. 11) 9, /3 5> =-� _1• ", T . . , , .r., : ..« te:Fart .•.�_ t- '.t!1; .7. 777,!1:7:4.: : Contractor: _ �G KJ.GG4l ` �s ' r I '...b.:1, c' • 1 . Add g 5 sw snr A•✓. *r 71Ale,.( - . ) -- 0 17 (Pun Qtl Ga✓/7, o'f.9 a,J q Type of carat 2 Phone: (405) • 2 z • 061 ,. / O +w cssa: J t- if" r Spmiaeted7 Yes No Contractors LW!, N "t - 13456 patter oocy of came O rns,J Sv. R of oroject a', 27ti Cont name & Dnona: Matt S*Z4_ Stay (tat. 2nd, art;) / c' . f- �� Proposed we: Dff ld AN 114' -1 4I(4 A7chitectlEnpinaar. ?)(4.0 Address: 62 a.A.! /dfd i/y sr P A'^cus use: �� (,J� �� A Na e & mechanical plena 1 must be submitted at erne at Phone: ( ). G23 • 8_567.0 }r+Q permit appti�oelion tl` y � 1 JOB DESCRIPTION: L 17A) A Al-.4° A‘ e-- Y t S _Q f 7' i V U 2....... . , U • ti23• 86 (AD Applicant Signatu - & Phone number !�!�'_' — _______SM Received by: Data Received: /1 (q- f ill / rim A %-ie---" igh elk_ F—W ? .,._„, 5•1 /�h►rN :a ` June 4, 1996 curt OF TIGARD OREGON Stock and Associates 82 University Street Seattle, WA 98101 Re: NIKE TETRA "FIRE ALARM" 15705 S.W. 72nd Avenue PC5 -49C BUP96 -0255 The plans, battery calculations, and component cut sheets have been reviewed for conformity to applicable codes. Provide three (3) sets of revised plans incorporating the following items of protection: 1. Provide a cross - section of the building showing pitch of roof, height of building, and depth of structural roof beams. Detectors shall be located in accordance with UFC Std. 10- 3- 3 -5.3. 2. Provide a floor plan of the mezzanine with full detection in accordance with UFC Std. 10- 3- 2 -7.4. 3. The floor plan of the office showing locations of detectors and the FCI fire alarm legend does not provide a fully automatic fire alarm system in accordance with the Building Official's letter of May 6, 1996, and UFC Std. 10- 3- 2 -7.4. Provide coverage throughout the building as required. If you wish to discuss any of these items, please give me a call. Sincerely, X/ % James Funk Plans Examiner � bup96- 0255 \pc5- 49c.doc � ( 1 / 1 7 10' ar 125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 December 17, 1997 CITY OF TIGARD OREGON Bruce Stock Stock and Associates 82 University Street Seattle, WA 98101 Re: Nike Tetra "Fire Alarm" 15705 SW 72nd Avenue PC# 49C BUP# 96 -0255 We are in receipt of your as builts dated April 8, 1996 and a request for relocating the horns and strobe to 14 feet above finished floor. Are these ceiling mounted appliances? Ceiling mounted notification appliances are regulated by NFPA 72, Section 6-4.4 and Table 6- 4.4.1(b). The problem lies with the type of appliance specified. A Wheelock MT- 24- LSM -VFR specified for the manufacturing warehouse is noted as a wall mounted appliance. The pattern of appliances throughout the warehouse and manufacturing area appear to be on 24 foot spacing. Additional strobes are required. Provide ceiling mounted fixtures and new battery calculation using the correct number of appliances required by the standards. Sincerely, /Jim Funk Plans Examiner c: Howard Wright Capitol Electric, Inc. . PO Box 3764 12810 NE Airport Way Portland, OR 97024 Portland, OR 97230 -1029 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 6 -13 -1996 3.10PM FROM CAPITOL ELECTRIC 2577121 P. 1 ao (9 263-- CAPITOL ELECTRIC CO., INC. 12810 NE AIRPORT WAY PORTLAND, OR 97230 -1029 Owner TETRA PLASTICS (503) 255 -9488 Architect BRUCE STOCK Contractor FLETCHER WRIGHT Field Other DESIGN VARIATION /CLARIFICATION REQUEST TO: CITY OF TIGARD REQUEST NO: 326 13125 SW HALL BLVD TIGARD OR 97223 ATTN: JAMES FUNK Q �� , / PROJECT : TETRA PLASTICS DATE: 6/13/96 ` 07 OUR JOB #: 96 -75 d REQUESTED BY: RANDY TAS k 6 �r Action: ` / ( ) No Additional Action Required 5 \, (X) PLEASE PROVIDE ADDITIONAL INFORMATION x ( ) Convert to Change Order Proposal No. J� INFO REQUESTED: TETRA PLASTICS HAS REQUESTED US TO RELOCATE THE FIRE HORN STROBE DEVICES , IN THE MANUFACTURING AND WAREHOUSE AREAS OPENLY, TO A HEIGHT OF 14' ABOVE THE FLOOR. THEY INDICATE THE 80" HEIGHT WHERE THEY ARE LOCATED NOW IS TO LOW FOR THE SHELVING AND THE MATERIAL THAT MAY BE TEMPORALLY STACKED AGAINST THE WALL IN NORMAL DAY TO DAY OPERATIONS. V / || �_ / | [ 4 /- liF _ 4 )d)11_ ?v ) y 1 ei/2-L.44/0/ /2 f _ 14 ? _40 -7 d)- 7 0 cd_k- 7 f D 4_111 a 3r? _ f)•141-7 .3 0 Z el- 1/1 ,d o--7 — 4 12 (. 7 vv.? ej)) 7 ‘ 7-2,„ e l/7/ b/i t „, r 4 Pig 401 tc/ --'-' --- -----p- - -----------�-----' - --------- -- - ----'--- - ----- _ - -- -__- / CAPITOL /57O5 5 'v 72'L(zfv e_ ELECTRIC CO., INC. 12810 NE AIRPORT WAY PORTLAND, OR 97230 -1029 • (503) 255 -9488 FAX 257 -7121 LETTER OF TRANSMITTAL DATE: 12/12/97 TO: CITY OF TIGARD ADDRESS: 125 SW HALL BLVD. TIGARD OR. 97223 ATTENTION: JAMES FUNK - PLANS EXAMINER PROJECT NAME: TETRA PLASTICS ATTACHED: BID PROPOSAL SUBMITTALS CHANGE ORDER SPECIFICATIONS LETTER SHOP DRAWINGS LIEN WAIVER X OTHER NUMBER OF COPIES: DESCRIPTION: 3 FIRE ALARM PREMIT CORRECTION DRAWINGS DATED APRIL 8 1996 1 COPY OF ORIGINAL TRANSMITTAL DATED 6/13/96 1 COPY OF INFORMATION REQUEST # 326 DATED 6/13/96 1 COPY OF 6/20/96 DAILY LOG REFERING = IVAL WAL ' ROUGH, ACCEPTANCE OF FIRE ALARM TEST A ACCEPTANCE Tai RAISE HORN STROBES IN MANUFACTURING A' X FOR YOUR USE X FOR YOUR REVIEW X FOR APPROVAL REMARKS SIGNED X MAILED DELIVERED CAPITOL /570 5 5-t✓ 72 ( ELECTRIC CO., INC. 12810 NE AIRPORT WAY PORTLAND, OR 97230 -1029 (503) 255 -9488 FAX 257 -7121 LETTER OF TRANSMITTAL DATE: 6/13/96 TO: CITY OF TIGARD ADDRESS: 13125 SW HALL BLVD TIGARD OR ATTENTION: JAMES FUNK PROJECT NAME: TETRA PLASTICS ATTACHED: BID PROPOSAL SUBMITTALS CHANGE ORDER SPECIFICATIONS LETTER SHOP DRAWINGS LIEN WAIVER X OTHER NUMBER OF COPIES: DESCRIPTION: 2 REVISED FIRE ALARM DRAWINGS 1 INFORMATION REQUEST FORM X FOR YOUR USE X FOR YOUR REVIEW X FOR APPROVAL REMARKS SIGNED MAILED X DELIVERED • /07o5 s v✓ 7 z, -.o( "vf CAPITOL ELECTRIC CO., INC. 12810 NE AIRPORT WAY PORTLAND, OR 97230 -1029 Owner TETRA PLASTICS (503) 255 -9488 Architect BRUCE STOCK Contractor FLETCHER WRIGHT Field Other DESIGN VARIATION /CLARIFICATION REQUEST TO: CITY OF TIGARD REQUEST NO: 326 13125 SW HALL BLVD TIGARD OR 97223 ATTN: JAMES FUNK PROJECT : TETRA PLASTICS DATE: 6/13/96 OUR JOB #: 96 -75 REQUESTED BY: RANDY TASKER Action: ( ) No Additional Action Required (X) PLEASE PROVIDE ADDITIONAL INFORMATION ( 1 Convert to Change Order Proposal No. INFO REQUESTED: TETRA PLASTICS HAS REQUESTED US TO RELOCATE THE FIRE HORN STROBE DEVICES , IN THE MANUFACTURING AND WAREHOUSE AREAS OPENLY, TO A HEIGHT OAP ABOVE THE FLOOR. THEY INDICATE THE 80" HEIGHT WHERE THEY ARE LOCAT D NOW IS TO LOW FOR THE SHELVING AND THE MATERIAL THAT MAY BE TEM ORALLY STACKED AGAINST THE WALL IN NORMAL DAY TO DAY OPERATIONS. crud 04A ya et2Of / �r U I/'IIL.A1f l � r .fit/ ft44 5 X r e t m 4. 4rz, dpq, -cJ ..CAPITOL /570 5 s t,LJ 7 ELECTRIC CO. INC. 12810 N.E. AIRPORT WAY PORTLAND, OR 97230 255 -9488 DAILY LOG JOB: - 7 - 61-r.,, PI c,5 Date: C di'j - ‘i,� JOB # : el `ig Weather: C_1 C . LOCATION: 7 ra Temperature. Number And Types of Men Working Other Major Contractors On The Job Foremen g Journeymen a.. a_54 Apprentices Work In Progress: J O (skid, -S e S'MJ, SP v GP . ► 2-Er P f J A -j t Q rr) ft, To (IA , i • 110d -P rocs I LJ q 4 k R ,k A- I A rtv, Tes-j- , e tit ry -if.;' - S ok 17, 7 rc OPAPC M' Signature /,�