Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Specifications
FIRE ALARM CONTROL PANEL • Model 5208 :,, r Fire Alarm Control Panel with ,, ��' ° � ''';••11;'1 ` Digital Communicator " { t e +{ $ a e . `" The Fire Alarm Control Designed to Grow with Your t : C ' ,r x Systems Needs, Without The Growing Pains. r ..,P-''''.,_ b � � The SK -5208 is a microprocessor based control panel with integrated UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The Sk -5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK -5208 delivers the performance to handle your installation. Features control panel touchpad, remote • 10 zones, 8 Class B (Style B) annunciator, or Window' and 2 Class A (Style D) or Class downloading software B (Style B) zones, expandable • Built -in walk test feature . to 30 zones Specifications --_; • UL Listed Operating Voltage: 24 VDC , • Supervised zone expanders and Primary AC: 120 Vrms @ I/O modules can be mounted 60Hz, 2A •-w remotely from the main control Total DC Load: 6 Amp panel Current Draw: i: • Event History Buffer (150 events) Standby: 140 mA with date /time stamp Alarm: 460 mA • All zones are compatible with 2- Dimensions: or 4 - wire detectors Width: 16" (40.64 cm) Hieght: 26.4" (67.06 cm) • 8 selectable /programmable Depth: 4" (10.16 cm) output patterns for notification Operating Temp: 32° to 120° F appliance circuits (0° to 49° C) ' • Built -in Digital Alarm Optional Accessories Communicator Transmitter • SK -5235 LCD Remote (DACT) Annunciator SK -5208 • 4 Notification Appliance Circuits • SK -5217 10 Zone Expander • 4 programmable general (2 max. per system) purpose relays • SK -5280 Status Display Module • Programmable smoke .(8 max. per system) • verification, pre -alarm delay, • cross zoning and enhanced 7181 Fire Zone Converter verification mode features that • 5220 Direct Connect Module can help minimize false alarms • SKSS Downloading Software • Programmable from the built -in SILENT KNIGHT FiRE'A1,ARM CONTROL PANEL • Model 5208 Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled /disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 Telephone Line 2 2 Class A (Style D or Class 8 (Style pnitkation Circuits [ ogr rnlmsbte !) . 1 Form C Relays 8 Class B (Style B) , 1111 Initiation Circuits .. " 41 I Notification • • �' Appiianos Circuits r 5235 Remote *: Annunciators �I��p� - - CP To ABC' • SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800-446 -6444 or in Minnesota 612 - 493 -6435 FORM# 350318, Rev. 1/00 FAX: 612 - 493 -6475 Copyright ©2000 Silent Knight World Wide Web: http: / /www.silentknight.com ii Enhanced Model Name or Number Compatibility ID # per Loop • Manufacturer Mode (Base model name or number in Compatible parentheses.) Head Base 3011(301B) A A 20 3011L (301BUSS B401BH) N/A N/A 20 301P (301B) A N/A 20 301PL (301BUSS B401BH) A N/A 20 301PT (301B) A N/A 20 301P(301DH -2) A N/A 20 301I -DH (301DH -2) A N/A 20 2100S A N/A 20 2100TS A N/A 20 2100TR A N/A 20 FCI 2100AT A N/A 20 • a1 SBS -1101 A N/A 20 SBS -1201 A N/A 20 SBS -1201T N/A N/A 20 PSD -7155 (2WB /2WRLT /2WRB) P55FE1 FE51A 40 PSD -7155 (CPD -001/ -002/- 003/ -005) P56FE1 FE5 1A 40 PSD -7156 (2WB /2WRLT /2WRB) P55FE1 FEOIA 40 PSD -7156 (CPD- 001 / -002/- 003/ -005) P56FEI FEOIA 40 CPD -7051 (2WB /2WRLT /2WRB) CPD7051 FE51A 40 CPD -7051 (CPD- 001 / -002/- 003/ -005) CPD7051 FE51A 40 DH100P (Duct Housing) N/A N/A 40 S111-24F (HS -224D or HSB -224) N/A N/A 25 SLK -12 N/A N/A 25 SLK -24F (HS -224D) N/A N/A 25 Hochilti SLK -24FH (HS -224D) N/A N/A 25 - (HS224L) Heat Detector base N/A N/A 30 SLR -8358B 'N /A N/A 25 PSD -7155 (70- 201000 -001) P55FE1, FE51A, FE01A 40 P56FE1 Kidde - Fenwal PSD -7156 (70- 201000 -001) P56FE1 FEOIA 40 CPD - 7051 (70- 201000 -001) CPD 7051, FE51A, FE01A 40 I51FE1 P/N 151204 A -3 Model SK -5208 Fire Control /Communicator Installation and Operation Manua! Enhanced Model Name or Number Compatibility ID # per Loop Manufacturer Mode (Base model name or number in Compatible parentheses.) Head Base • 1100T 20 1151 (B 110LP) 20 1400 A N/A 20 1451(B401B) A A 20 2100 A N/A 20 2100AT A N/A 20 2100D A N/A 20 2100T A N/A 20 2100TR A N/A 20 System Sensor 2100TS A N/A 20 2151(B110LP) 20 2300 A N/A 20 2300T A N/A 20 2300TB A N/A 20 2400 A N/A 20 2400TH 20 2400 (DH400) A N/A 20 2451 (B401B) A N/A 20 2451 DH (DH 400) A N/A 20 2451TH (B401B) A N/A 20 Four Wire Smoke Detectors Manufacturer Model Hochiki SLR -835B with HD -6 Base ESL 445C Series 449C Series System Sensor 1851B 2851/2851BTH DH400AC/DC A_4 P/N 151204 Manufacturer Model Type MT- 24- WM -VFR Horn RS- 2415 -HFR Strobe RSP- 2415 -VFR Strobe RS- 241575 -VFR Strobe RSP- 241575 -VFR Strobe _..0 RS- 2430 -VFR Strobe RS- 2430 -HFR Strobe RS- 2475 -VFR Strobe RSP- 2475 -HFR Strobe RS- 24110 -HFR Strobe RSP- 24110 -HFR Strobe SL- 24 -VFR Synchronized Remote Strobe SL1- 24 -VFR Synchronized Remote Strobe SL3- 24 -VFR Synchronized Remote Strobe SLP- 24 -VFR Synchronized Remote Strobe SLM- 24 -VFR Synchronized Remote Strobe SLIM- 24 -VFR Synchronized Remote Strobe SL3M- 24 -VFR Synchronized Remote Strobe Wheelock (Cont.) SLPM- 24 -VFR Synchronized Remote Strobe SHW- 24 -VFR Synchronized Remote Strobe SH2W- 24-VFR Synchronized Remote Strobe SHPW- 24-VFR Synchronized Remote Strobe SCM -24 -R Controller for Synchronized Strobes • SM- 12/24 -R Sync Module SR- 2415 -VFR Sync Strobe SRP- 2415 -HFR Sync Strobe SR- 241575 -VFR Sync Strobe SRP- 241575 -VFR Sync Strobe SR- 2475 -VFR Sync Strobe SR- 2475 -HFR Sync Strobe SR- 24110 -HFR Sync Strobe SRP- 24110 -HFR Sync Strobe V7001T- 12\24 -W -FR Strobe Horn WM3T -24 -FR Remote Strobe WM3T- 24-VFR Remote Strobe WS 1T -24 -FR Strobe WS3T -24-FR Strobe WST -24 -FR Strobe P/N 151204 A -11 • Model SK -5208 Fire Control /Communicator Installation and Operation Manual Manufacturer Model Type 46T- G4 -24 -R Bell 46T- G6 -24 -R Bell 46T -G 10 -24-R Bell 46T- G6- 24- WS- 24 -HF -R Strobe/Bell 46T- G10- 24- WS- 24 -HF -R Strobe/Bell 46T- G6- 24- WH- 24 -HF -R Strobe/Bell 46T- G10- 24- WH- 24 -HF -R Strobe/Bell 7001T- 12\24 -W -FR Strobe Horn 7002T- 12\24 -W -FR Strobe Horn AES -DLL -R Multitone Horn AES -ELI -R Multitone Horn AES-DL I -WS-24-VF-R Multitone Horn AES-EL I -WS-24-VF-R Multitone Horn AES- DL1- WH- 24 -VF -R Multitone Horn AES- EL1- WH- 24 -VF -R Multitone Horn AES- DLI- WM- 24 -VF -R Multitone Hom AES- ELI- WM- 24 -VF -R Multitone Horn AH -24 -R Hom AMT - 12\24 -R Strobe Horn AMT- 24- LS -VFR Strobe Horn AMT- 24- LSM -VFR Strobe Horn AMT- 24- IS -VFR Strobe Horn AS- 2415 -VFR Strobe Horn Wheelock - AS- 241575 -VFR Strobe Horn AS- 2430 -VFR Strobe Horn .4 AS- 2475 -VFR Strobe Hom AS- 24110 -HFR Strobe Horn SM- 12\24 -R Strobe Hom Controller DSM- 12\24 -R Strobe Horn Controller CH -BFI Chime CH-BF I -R Chime CH -CF1 Chime CH -CFL -R Chime CH -CFL -W Chime CH -DF I Chime CH -DFI -R Chime CH- BFI- WS- 24 -HF -R Strobe Chime CH- CFI -LS -24 Strobe Chime CH- CFI -MS -24 Strobe Chime CH- CFI -IS -24 Strobe Chime CH- CF1- LS- 24 -CFW Strobe Chime CH- CF1- MS- 24 -CFW Strobe Chime CH- CF1- IS- 24-CFW Strobe Chime CH- CF1- WS- 24 -CF -W Strobe Chime CH- DF1 -LS -24 Strobe Chime CH- DFL -MS -24 Strobe Chime CH- DFL -IS -24 Strobe Chime A -8 P/N 151204 ® � SBS -1101 1 FIRE CONTROL INSTRUMENTS IONIZATION SMOKE DETECTOR DESCRIPTION �y The SBS -1101 dual- chamber ionization smoke detector is :tr. specifically designed to meet the performance meats require of fire detection/alarm systems. This detector uses a state-of- the-art unipolar sensing chamber. The detector is designed to provide open area detection and is compatible with FCI fire alarm control panels. The detector operation and sensitivity can be tested in place. The detector has an LED which flashes every ten seconds indicating that power is being applied to the detector. The LED lights steadily when the detector is in alarm. A remote FEATURES LED annunciator is available as an optional accessory. The SBS -1101 detector includes a tamper- resistant feature • Unique Dual Unipolar Sensor Provides that, when used, prevents removal of the detector without the exceptional Stability use of a tool. • Built -in Tamper- resistant Feature Sensitivity testing is performed by inserting a tool into the • Built-in Test Switch recessed test switch opening. • Built-hi Visual Alarm Indicator Field metering of detector sensitivity may be performed with the aid of a voltmeter and test kit Part No. 119- 9010N. • Remote LED Option • Compatible with FCI Control Panels APPROVALS • Field metering of Detector Sensitivity • Removable Insect Screen and Cover for U.L. (STD 268) S 911 Field Cleaning • Sealed against Dirt, Insects, and Back C.S.F.M. 7271 - 0694:145 Pressure FM 0Q7A3.AY • bisect-resistant Screening NYC BS &A 1539 -88 -SA (.020 " /.508mm Openings) • Convenient Terminal Strip Wiring TECHNICAL SPECIFICATIONS Nominal sensitivity 1.5 % /ft. obscuration Operating voltage 8.5 - 35 VDC (24 VDC nominal) Standby current 100 uA maximum Operating temperature 32 to 120 F, (0 to 49 C) Operating humidity 10% to 93% relative humidity Air velocity 1,200 feet per minute max. Altitude 10,000 feet Constuction Off -white flame - retardant plastic Diameter 5.5 inches (14 cm) Height - 3.12 inches (8.0 cm) Weight 0.71b. (310 gm) ORDERING INFORMATION Part Number Model Description 110 - 3105J SBS - 1101 Ionization Detector 269 GROVE ST. NEWTON, MA 02166 - 2295 USA TEL: (617) 965 =2010 TELEX: 94 -8212 FAX: (617) 965 -0659 9020- 0245Ner. 1.0 - - MOUNTING RECESSED TAMPER TEST SLOT SWITC - • • On a 4-inch square box with plaster ring — . • . and FCI supp lied mounting bracket kit. �� J Minimum depth 1.5 inches. • On a 3.5 or 4 -inch octagonal box. ( —I''1 i ' Minimum depth 1.5 inches. LEO • Directly to ceiling using plastic screw TEST SOCKEY SWITCN ITM anchors. 0. 1' MAX. DIAMETER TOOL Refer to N.F.P.A. 72, Chapter 5 -3. "Smoke Sensing VIEWS SHOWING POSITION OF TEST MAGNET Fire Detectors" for spacing, location of detectors and other guidelines. INSTALLATION �� ^mi Line up the arrows on the detector with the arrows 4411 on the mounting bracket. Turn the detector clockwise REMOVABLE until the detector clicks IOR To use the tamper -proof into break the smaller tab ��� I � CLEANN at the scribed line in the tamper -proof tab located on the — detector mounting bracket. Install the detector. To re- !' move the detector from the bracket when using the ,-,-,. REMOVABLE S CREEN • tamper -proof feature, insert the blade of a small screw- c driver into the hole on the side of the base and push the plastic lever away from the detector head. Turn the i LOCK detector counterclockwise for removal. NOTE: The ` r . decorative ring must be removed in order to remove a head after it has been made tamper- proof. NOTE: The number of two -wire smoke detectors which can be accommodated per zone varies with dif- ferent control panels. Consult the control panel in- struction manual to determine the capacity. TESTING WARNING: To prevent detector contamination during construction, smoke detectors roust be Detectors may be tested locally in the following . protected,from dust and contamination until area ways: is clean-and dust free. See NFPA72- 54.7.1 -3 • A. Insert a tool into the test opening in the unit. For the complete procedure, refer to the Installation and Maintenance MAINTENANCE Instructions furnished with each detector. • B. Field metering of detector sensitivity Cleaning programs should be adapted to the individ- g ty ual environment We recommend, at the least, an annual may be performed with the aid of a voltmeter cleaning of the unit The detector screen and cover and test kit P/N 119- 9010N. For the complete assembly can be removed, revealing the sensing chain- procedure, refer to the Installation and ber. A vacuum cleaner can be used to remove dust from Maintenance Instructions furnished with each the screen, cover and sensing chamber. For the com- • detector. plete procedure, refer to the Installation and Mainte- nance Instructions furnished with each detector. - VITIATING CIRCUIT EOL -D ,440 . I ( ----112 oa r AT PANEL I NOTE: Polarity must be observed only If remote annunciator is used. __Style r 6pttarml liiilirn MilL nounis control panel) - WIRING DIAGRAM! FOR USE WITH FCi CONTROL PANELS l .. Specifications am provided for hrformatlon only and am believed to be accurate. However, no responsibility is assumed by Fire Control Instruments, Inc. for their use. Specifications subject to change without notice. 01996 All Rights Reserved 4 a 0 Series F'SYSTEM Plug -in �$ SENSOR' Smoke Detector Models Available -- 1451 Ionization Detector SSV120 - 1451A Ionization Detector, , �,I ` � ULC Listed : td I ,t 2451 Photoelectronic Detector 2451A Photoelectronic Detector, , ULC Listed 2451TH Photoelectronic with Thermal !f - — 4' 5451 Thermal Rate -of -Rise _ , - `. - �a l - ', . ,� # 1' I f1(., � � � ' li - .__._.� . ..._ -_. _. , Product Overview Low standby current System Sensor's 400 Series plug -in smoke detectors are designed to meet the per - Two visible LEDs "blink" In standby formance criteria designated by UL /ULC. The ion and photo units have a sensing and provide a 360° field viewing chamber sealed from back pressure air flow, dirt, and insects. This chamber is pro- tected by a fine mesh screen which can be cleaned or replaced. Additional key angle features include a recessed mounting option, interchangeable Ion, photo, or ther- Wide variety of mounting bases with mal detectors, a variety of mounting bases, and a full line of optional accessories. built shorting spring Ionization. All 400 Series ionization smoke detectors include a specially designed Detector head plugs easily Into base dual source, dual unipolar detector chamber design which will sense the presence of Built - in test switch smoke particles produced by fast combustion as well as slow smoldering fires. This chamber exhibits increased stability, significantly reduces nuisance alarms, and pro - Field sensitivity metering of detector vides better performance at higher air velocities. to meet the requirements of NFPA 72 Built - in tamper - resistant feature Photoelectronic. All 400 Series photoelectronic smoke detectors contain an optical sensing chamber designed to sense the presence of smoke particles produced by a SEMS screws for easy wiring wide range of combustion sources. A custom integrated circuit incorporates signal Optional recessed mounting processing to reduce false alarms. Removable cover and insect screen Thermal. The 400 Series thermal rate -of -rise with fixed heat detector contains a for fleid cleaning unique dual thermistor heat sensing circuit to provide maximum performance and solid state reliability. The Model 5451 is designed to initiate an alarm at 135 °F and to respond to a temperature increase in excess of 15° per minute. This enables the heat detector to communicate an alarm to the central control panel prior to reaching ® CO the static set point for these high rates of rise, providing a timely response to both LISTED rapid and slow temperature increases. This model should be used in applications T where rapid response is desired and where rapid temperature increases would only be caused by a fire emergency. MEA (, ) MSFM approved approved I1 - . • -‘1 SUPPLEMENTARY FIR E ALARM NOTIFICATION APPLIANCE CIRCUIT PANEL • (SNAC) INSTALLATION/OPERATING MANUAL Copyright 1995 First Printed: November, 1995 All Rights Reserved Last Printed: January, 1996 Published in U.S.A. Part Number: 9000-0348 Version 1.1 • • - • FIRE CONTROL • INSTRUMENTS • - - • • Serial Number • ( I 269 GROVE ST. NEWTON, MA 02166-2295 USA TEL: (617) 965-2010 TELEX: 94-8212 FAX: (617) 965-0659 2.0 SPECIFICATIONS • ELECTRICAL Operating input power 120 VAC, 3 amp. or 240 VAC, 2 amp. (Jumper selectable); 50/60 Hz, �.... non -power limited. 6 Operating output voltage 24 VDC (nominal) Standby battery circuit 24 VDC (nominal), 0.27 amp. max. charging current. 7 NH max. battery capacity, non -power limited. Supervisory current (quiescent) .060 amp. Alarm current .120 amp. Alarm output 6.0 amp. max. from all circuits combined. External power output 0.175 amp. max. @ 24 VDC, .02 V. ripple non - resettable, power limited. (For use with FCI FM -900 series 24 VDC door holders. See Sec. 3.8) MECHANICAL • Dimensions 14° H x 14" W x 31/2° D. All field wiring circuits are power limited. 3.0 INSTALLATION 3.1 AC Input The SNAC contains a three- terminal block, TB2, for connection to "hot", ground and neutral of a 120 VAC input source fused at 3 amperes maximum. This connection must be to a dedicated branch circuit and mechanically protected. All means of disconnecting the circuit must be clearly marked °FIRE ALARM CIRCUIT CONTROL° and accessible only to authorized personnel. Fusing of this circuit must comply with local codes for over current protection, and/or Article 760 -- °FIRE PROTECTIVE SIGNALING SYSTEMS" of the National Electrical Code, NFPA 70. The SNAC is jumper - selectable for operation from either 120 VAC or 240 VAC input. Cut Jumper W101 for 240 VAC operation. CAUTION: Failure to cut Jumper W101 for 240 VAC operation will damage the unit. 3.2 Earth Ground • The SNAG panel must be connected to an earth ground per Article 760 of the National Electrical Code, NFPA 70. A green wire lead is provided for this purpose. • CAUTION: Failure to make a proper earth ground connection to a metallic cold water pipe or driven - ground ' rod to the green °GND" wire will result in the loss of.frghtning protection and reduce the tolerance of the system to transients. 3.3 Battery Standby The SNAC can maintain two (2) 12 volt sealed lead -acid batteries of up to 7 ampere -hour capacity connected in series. The batteries may be _installed in the space at the bottom of the cabinet. Insert Jumper W9 to enable the charger. Remove W9 if the charger is be disabled, in the event an auxiliary charger is to be used. Standby period Battery size 24 -60 hours 7Ah • Use only battery Model B7R 6 of 13 9000-0348 • C• MS SERIES (0) FIRE CONTROL INSTRUMENTS NON - CODED, MANUAL FIRE ALARM STATIONS APPROVED Model MS -2, MS -2H The MS -2 manual fire alarm stations are double action devices. These stations requires that the outer door be lifted 1 to expose the actuation door which is then pulled forward to A RI yl4„ operate the alarm toggle switch. The actuation door is now locked in the readily observable "alarm" position. J t a To reset the station, a key ( common to FCI control panels) must be inserted and turned 1/4 turn clockwise, opening the MS - MS - 2H station. Closing the station resets the switch automatically. An optional breakglass rod is available for positive indica- tion of station operation. - PULL' Model MS -2P (Presignal) `J i FIRE Operation of the Model MS -2P presignal station is similar to that of the MS -2, with the addition of a key - operated switch FIRE mounted on the lower door. This switch may be used for I , ALARM; - y "general alarm" signaling. I pUU- • Model MS -2L, MS -2LP (Institutional) MS-6 MS -WS Operation of the Model MS -2L institutional station re- quires that a special key be used to release the actuation door before it can be operated. This lock may be keyed as required FEATURES by the particular application. The MS -2LP features an addi- tional key - operated switch mounted on the lower door. • Single and Double Action Versions Model MS -2 -D (Multiple Contact) • Tumbler Lock for Test and Reset The MS -2 -D features a DPST switch for multiple signaling Keyed Alike with FCI Controls via wire lead connections. • Positive Indication of Operation over Model MS -6 (Single Action) 180 Viewing Angle The MS -6 station is a single action device, requiring only • Surface or Semi -flush Mounting the pulling of the action door to release the compressed (MS -2, MS -6) button switch. It is available either with terminals (MS -6T) or wire leads (MS -6). • Shock and Vibration Resistant The station resets in the same manner as the MS -2. The reset • NEMA 3 Weatherproof Version key is common to FCI control panels. (MS-WS) Model MS - (Weatherproof) • Institutional Version (MS -2L) The surface mounted cast aluminum MS -WS station has a • Institutional Presignal Version protective hood over the actuation door which offers genuine (MS -2LP) NEMA 3 weatherproof construction. The pull door is held in place by a breakglass rod and extends below the body of the • Presignal Version (MS -2P) station so it can be pulled outward to operate even if ice • Optional "FIRE SUPPRESSION coated. The reset key is common to FCI control panels. P The surface mount backbox is threaded for 1/2 -inch (12.7 SYSTEM RELEASE" Markings mm) conduit fittings both on top and bottom. (MS -2H) • Optional DPST Switch (MS -2 -D) Specifications are provided for information only and are believed to be accurate. However, no responsibility is assumed by Fire Control Instruments, Inc. for their use. Specifications subject to change without notice. 01997 All Rights Reserved 301 2nd Ave Waltham, MA 02451 -1133 USA TEL: (781) 487 -0088 FAX: (781) 370 -4132 9020- 0358Ner. 1.5 • • t i 111 ` "6detlnY wod!' SLitchbox ` 1 172" (3.01 an( mlo. dept I .ro... Model BBQ Sudan Bulb= AGENCY APPROVALS UL (Std 38) File S2465 FM (MS -2, MS -WS) 0J3A9.AY/12880 (MS -6, MS -6T) 1D4A7.AY C.S.F.M. (MS -2, MS -6) 7150- 0694:107 (MS -WS) 7150- 0694:136 NYC BS &A (MS -2, MS -WS) 960 -81 -SA NYC MEA (MS -6) 103 -93 -E SPECIFICATIONS Material (MS -2, MS-6) Extruded 6063/T5 aluminum Doors (MS-2, MS -6) Clear anodize Switch type MS-2 Enclosed toggle MS-6, MS -WS Enclosed push button Contact material Silver plated bronze or copper Contact ratings MS-2 6 amp. max. @ 30 VDC (resistive) MS-6 0.5 amp. max. @ 30 VDC (resistive) MS-WS 3 amp. @ 30 VDC (resistive) Dimensions (overall) MS- 2,MS -6 5" H x 3.4" W x 2.8" D (12.7 cm x 8.64 cm x7.11cm.) MS-WS 5.8" H x 3.5"W x 2.75" D (14.73 cm x 8.89 cm x 6.99 cm ) ORDERING INFORMATION Part No. Model Description 1100 -0615 MS -2 Double action fire alarm station 1100 -0634 MS -2H Double action station with "FIRE SUPPRESSION SYSTEM RELEASE" markings 1100 -0619 MS -2P Presignal fire alarm station 1100 -0621 MS -2L Institutional fire alarm station 1100 -1096 MS -2LP Institutional presignal fire alarm station 1100 -0617 MS -2 -D Double action station with DPST switch 1100 -0632 MS -6 Single action station, wire leads 1100 -0633 MS -6T Single action station, terminals 2520 -0023 BB -2 Surface back box for MS -2, MS -6 stations 1120 -0206 Package of two replacement breakglass rods For MS -2 station 120 -1312G MS -WS Weatherproof station with surface backbox 2500 -0247 GR -1 Replacement glass rod for MS -WS 2 of 2 9020 -0358 :, it ,v G SYSTEM 400 Series TM � , SENSOR® High - Temperature A Division of Pittway 3325 Ohio Avenue, SL Charles, IL 60174 Duct Smoke Detector 1- 300- SENSOR2 (736 - 7672), Fax 630-377-6495 littp://www.systernsensoncom . ,..:: " . _ System Sensor DH400ACDCIHT provides a higher . _- e --� " temperature range than standard duct detectors for installation in extreme environments. The DH400ACDCIHT samples air currents passing through a i ' duct to provide dependable performance for management . ;, of fans, blowers, and air conditioning systems. The twist- in, twist -out 1451DHHT High- Temperature ionization is detector head allows easy removal for quick cleaning, maintenance, and replacement without removing the duct o housing. Specifications Agency Listings Length: 14.5 inches (36.8 cm) DH400ACDCIHT UL S911 Width: 5 inches (12.7 cm) APA451 UL 54011 ` Depth: 4 inches (10.2 cm) RTS451KEY UL S2522 Weight: 4.5 lbs. (2.0 kg) RTS451 UL 52522 Operating RA400Z UL S2522 Temperature Range: 32° to 158 °F (0° to 70 °C) PA400 UL S3593 Operating _ Humidity Range: 10 % to 93 % relative humidity Air Duct Velocity: 500 to 4000 ft. /min. Voltage: 24VAC /VDC or 120/220 VAC Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations, and several different means of visible and audible system annunciation. As with our duct detectors, all duct detector accessories are UL listed. . 1 / 0 0 0 II ILINIllil i t (� o o 1 ; 11 1111 1111 - 1 To - �E i li 1! 11111111411111.111.111111 1 0 0 0 r 0 f APA451 RTS451KEY PA400 with RTS451 RA400Z Piezo Remote Test PS24LOW Add -on Strobe Remote Test Remote Annunciator Station with Key (PS12 /24LENSW Station Annunciator smoke lens option available) o System Sensor 9/97 This document is not intended to be used for installation purposes. A05- 953 -01 • Electrical Ratings - DH400ACDCIHT Power Supp6 Voltage 20 - 29 VDC I 24 VAC 50 - 60 Hz I 120 VAC 50 - 60 Hz I 220/240 VAC 50 - 60 Hz CURRENT REQUIREMENTS (USING NO ACCESSORIES) Max. standby current 25 mA 35 mA RMS 20 mA RMS 20 mA RMS Max. alarm current 95 mA 55 mA RMS 55 mA RMS 30 mA RMS CONTACT RATINGS Alarm initiation contacts (SPST) 2.OA @ 30 VAC/DC (0.6 power factor) c eeessory Current Loads at 24 VDC Devlee Standby Alarm APA451 12mA MAX 30mA MAX Alarm auxiliary contacts (DPDT) 10A © 30 VDC PA400 OmA i5mA MAX 10A @ 250 VAC RA400Z OmA 7mA MAX RTS451 OmA' 7.5mA MAX RTR451 Kti' lmA• 7 5mA MAX Trouble contacts (SPST) 0.3A @ 32 VDC (resistive) *NOTE: When initiating an alarm. the RTS451 and RTS45IKEY require 103mA in alarm. Nominal ANY COMBINATION OF ACCESSORIES MAY BE standby current is OmA. Alarm current Is 8 mA maximum when test magnet is removed. USED SUCH THAT THE GIVEN CURRENT LOADS TOTAL: NOTE: Accessories are only rated to 120'F and must be installed Indoors. 100mA OR LESS IN THE STANDBY STATE, 150mA OR LESS IN THE ALARM STATE. Architectural /Engineering Specifications The air duct smoke detector shall be a System Sensor Station. The duct detector housing shall incorporate an Model DH400ACDCIHT Series Duct Smoke Detector. The airtight smoke chamber in compliance with UL 268A. The detector shall be UL listed per UL 268A, standard for housing shall be capable of mounting to rectangular or Smoke Detectors for Duct Applications, specifically for use round ducts up to 12' wide without adapter brackets. An in air handling systems. The detector shall operate at air integral filter system shall be included to reduce dust and velocities from 500 feet per minute to 4000 feet per residue effects on detector and housing, thereby reducing minute. The detector shall have an operating temperature maintenance and servicing. Sampling tubes shall be range of 32 °F to 158 °F. The detector housing shall be installed after the housing is mounted to the duct by equipped with an integral mounting base capable of passing through the duct housing. Terminal connections accommodating ionization detector heads. It shall be shall be of the strip and clamp method suitable for 14 -18 capable of local testing via magnetic switch or remote AWG wiring. testing using the RTS451KEY or RTS451 Remote Test Ordering Information Fart No. Description RTS451 Remote test station DH400ACDCIHT 4 -wire ionization high- temperature duct PA400 Piezo sounder smoke detector ' RA400Z Remote annunciator alarm LED 1451DHHT Replacement ionization high- temperature CRT400 Ion cover removal tool sensor head F36 -05 -00 Replacement air filters ST -1.5 Metal sampling tube duct widths 1' -2' (two per package) ST-3 Metal sampling tube duct widths 2'-4' MOD400R Sensitivity test module ST -5 Metal sampling tube duct widths 4' -8' MO2 -04 -00 Test magnet ST -10 Metal sampling tube duct widths 8' -12' RS14 Ion replacement screen P48 -21 -00 End cap for metal sampling tubes A2650 -01 Replacement installation kit APA451 Annunciator with piezo alarm and power (mounting hardware) LEDs RTS451 KEY Remote test station with key System Sensor Worldwide Manufacturing & Distribution In Canada: In the Far East: In Italy: Telephone: 905- 812 -0767 Telephone: 852- 2191 -9003 Telephone: 39-40- 9490 -111 Fax: 905 - 812 -0771 Fax: 852- 2736 -6580 Fax: 39-40- 382137 In China: In India: In the United Kingdom: Telephone: 852 -2191 -9003 Telefax: 91- 022- 8202564 Telephone: 44 -1403- 276500 Fax: 852- 2736 -6580 Fax: 44-1403-276501 Page 2 A05- 953 -01 n ui INC. FIRE ALARM SYSTEMS ADA �' :-- E 5946 M EA CSFM: SERIES SM AND DSM 7300 - 0785:132 151.92 -E SYNC MODULES Description Wheelock's Series SM and DSM Sync Modules are utilized with the Series AS /AH, Series NS /NS4 /NH, Series RSS, Series RSSP, Series SL /SLM and selected strobe • applications with other Wheelock combination appliances. When used with Series AS Audible Strobes and /or Series NS Horn Strobes, the SM and DSM Sync Modules provide independent operation of synchronized temporal pattern (code 3) horn and synchronized strobe flash, as well as the ability to silence the horn while maintaining the strobe flash ... while using only a single pair of wires. The sync modules are available in two versions; the SM 12/24 for control of a Class B NAC circuit; and a dual output version, the DSM 12/24 for control of either a Class A or two (2) Class B NAC circuits. Series SM or DSM Features • Approvals include: Underwriters Laboratories (UL 1971) Listing, New York City (MEA), California State Fire Marshal (CSFM), European Community (CE), and Chicago (BFP) on all models. • Uniquely designed to accept an independent strobe and audible input from the FACP and convert to a single output that connects to Wheelock's Series AS or Series NS family of audible strobes. • Series SM and DSM Sync Modules can also be used to synchronize Wheelock's Series RSS, RSSP, SL and SLM Sync Strobes. • 3 ampere per circuit current handling at 12 or 24 VDC. • Low operating current draw. • Compatible with all standard fire alarm control panels. • Meets the NFPA -72 (1999) requirement for Temporal Pattern when used with the Series AS /AH and /or Series NS /NS4 /NH. • 3 year warranty. Copyright 1999 Wheelock, Inc. All rights reserved. .� l • • • A WARNING: ALTHOUGH UL TESTING HAS VERIFIED THAT SYNC MODULES FUNCTION EVEN AT 80% OF THEIR MINIMUM RATING AND 110% OF THEIR MAXIMUM RATING, WHEELOCK STRONGLY RECOMMENDS THAT THE VOLTAGE APPLIED TO THESE PRODUCTS BE WITHIN THEIR RATED INPUT VOLTAGE RANGE. THE APPLICATION OF IMPROPER VOLTAGE MAY RESULT IN DEGRADED OPERATION OR DAMAGE TO THESE PRODUCTS, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district. federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). A WARNING: CONTACT WHEELOCK FOR "INSTALLATION INSTRUCTIONS" (P83123 -SM & P83177 -DSM) AND "GENERAL INFORMATION" SHEET ON THESE PRODUCTS. THESE DOCUMENTS DO UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS INCLUDING: • TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. • FUSE RATINGS ON NAC CIRCUITS TO HANDLE MAXIMUM INRUSH OR PEAK CURRENTS FROM ALL APPLIANCES ON THOSE NAC CIRCUITS. • COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. • THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED INPUT VOLTAGE RANGE. • INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. • USE STROBES ONLY ON NAC CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBE ON CODED OR INTERRUPTED NAC CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBE MAY NOT FLASH. Ordering Information Order Input Average Current (Amperes)* Model Number Code Voltage at 12/24 VDC Mounting Options ** SM- 12/24 -R SYNC MODULE 6369 12 or 24 .014/.025 W DSM - 12/24 -R SYNC MODULE * ** 6374 12 or 24 .020/.038 W Average current per actual Wheelock Production Listing 12 & 24 VDC Nominal Voltage. R = Red • • Refer to Data sheet # S -7000 for Mounting Options. • ** The maximum number of interconnected DSM modules is twenty (20). The total distance from the first to the last DSM shall not exceed 1,000 feet of #18 AWG wire. Use only #18 AWG wire. a s' t ti ht maws 1 ,_ , ' „.T-Y 1....es , ,,a. , mac . \0/ _ nifiE,A, _ i.; ,, N. _.„,-.,:-\. ,---4 k ., A -\=. 411a__ ' 0 .. :islalr±...,_-_:. FIRE AEARM SYSTEMS Helping People Take ActaonTM O R1N , `� , , . TM SP LJ 1 - SERIES AS A Family of Multi- Candela Appliances SINGLE & MULTI-CANDELA Appliances' AUDIBLE STROBE APPLIANCES • SERIES AH AUDIBLES Description Wheelock's patented 2 -wire Series AS Audible Strobe y 7 _T _ ; """`"'" Appliances and Series AH Audibles offer more features _ ,. with Tess current draw and Zero Inrush. Strobe options for wall mount models include 15/75cd or ', 4M , � , i ;: -+ --" Wheelock's patent pending Multi- Candela strobe with field ., , , 5 , =f s ? ' '. ,„ - -�-- selectable candela settings of: 15, 30, 75 or 110cd. SERIES AS SERIES AH Ceiling mount models are available in 15, 30, 75 or 100cd intensities. The audible provides a selectable choice of either a 10111 , continuous horn or temporal pattern (Code 3) when '` -+� constant voltage from a Fire Alarm Panel (FACP) is 15 1 , 3D applied. Each tone has 3 dBA settings to choose from. Ili I 75 4 ' - 110' Additionally, the audible may be silenced while maintaining strobe activation on combination Multi- Candela Indicator Series AS units. (bottom of lens) All models may be synchronized when used in Features • conjunction with the Wheelock SM, DSM Sync Modules Approvals include: UL 1971, UL 464, California or the PS- 12/24 -8 Power Supply with Wheelock's State Fire Marshall (CSFM), New York City (MEA), Pending: Factory Mutual (FM) and Chicago (BFP). Patented Sync Protocol. • ADA/NFPA/ANSI Compliant. • Wall mount models are available with Field Synchronization of the continuous horn tone provides the Selectable Candela Settings of 15, 30, 75 or 110cd temporal (Code 3) tone as mandated by NFPA -72 (1999) (Multi - Candela models) or 15R5cd. for all audible appliances. This ensures a distinct • Ceiling mount models are available in 15, 30, 75 temporal (Code 3) pattern when 2 or more audibies are or 100cd. within hearing distance. If not synchronized, the • Selectable Continuous Horn or Temporal (Code 3). • temporal sound may overlap and not be distinctive. At 3 Selectable dBA settings (99, 95 and 90 dBA) in both the same time, the strobes will also be synchronized. This tones. • Patented 2 - Wire Audible Strobe Appliance. provides the ability to comply with ADA • Patented Universal Mounting Plate. recommendations conceming photosensitive epilepsy • Strobes produce 1 flash per second over the regulated and NFPA standards when installing two or more visual voltage range. appliances within the field of view. • 12 and 24 VDC models with wide New UL "Regulated Voltage" using filtered DC or unfiltered VRMS All of this, plus the ability to silence the audible is input voltage. • achieved by using only 2 WIRES. Wall Mount or Ceiling Mount models. • Synchronize with Wheelock SM, DSM or PS- 12/24 -8 Power Supply with Wheelock's built -in sync protocol. • ZERO Inrush above Peak. • Compatible with all Wheelock 2 -Wire products. • Fast installation with IN / OUT screw terminals using #12 to #18 AWG wires. Copyright 2000 Wheelock Inc. All rights reserved. S NO AIL- CAUTIONS and WARNINGS are Identified by the symbol A . All wamings are printed In bold capital letters. A WARNIrIG: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR 0 APPLYING TIIIIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATIQN, INSTALLATION AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AVID SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. General Notes • Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA -72 (1999) specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL 1971. • Series AS Strobe products are listed under UL 1971 for indoor use with a temperature range of 32° F to 120° F (0° C to 49° C) and maximum humidity of 85 %. • Series AH -24 homs are listed under UL 464 for audible signal appliances (Indoor use only). • Series AH -24WP audible appliances are listed under UL 464 for indoor /outdoor use with a temperature range of -31°F to 150 °F ( -35 °C to 66 °C) and maximum humidity of 95 %. • "Regulated Voltage Range" is the newest terminology used by UL to Identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range ". Table 1: Ratings Per UL 1971 Table 4: dBA Ratings for 12 VDC and 24 VDC Series AS/AH 12 and 24 VDC Audible Model Input Voltage VDC Regulated Voltage Sbobe Candela (cd) Description Volume Reverberant dBA Mecholc dBA (g 10 R Range VDCIFWR Per UL 484 @ 10 ft. AS- 24MCW -FR 24 16.0 - 33.0 15130/75/110 I4gh 91 99 AS- 2415W -FR 24 16.0 - 33.0 15 Cateravus Hom Medium 88 95 AS- 241575W -FR 24 18.0 - 33.0 15 (75 on Ads) low 83 90 AS 2430W - FR 24 16.0 -33.0 30 High 87 99 AS- 2475W -FR 24 16.0 - 33.0 75 Code 3 Hom Medium 84 95 79 90 AS 24110W - FR 24 16.0.33.0 110 Low AS- 1215W -FR 12 8.0 - 17.5 15 A+rsrage Current • (AMPS) for Audible Strobe AS - 121575W -FR 12 8.0 - 17.5 15 (75 on Ards) At the 3 Audible Settings all 18, 24, 33 a 8,12 and 17.5 VDC AS 24 18.0 - 33.0 15 Average Currant - with High dBA Setting (99 dBA) AS 24 18.0 - 33.0 30 Voltage AS -2415W AS- 241575W AS -2430W AS -2475W AS-24110W 18.0 VDC .104 .124 .152 240 291 AS 2475C - FW 24 18.0 - 33.0 75 24.0 VDC .087 .102 .120 .177 .202 AS - 24100C 24 16.0 - 33.0 100 330 VDC .090 .100 .119 .152 .183 Voltage AS-1215W AS-121575W Tabu 2: Average Current • (AMPS) for AS -24 MCW Wall Models 8.0 VDC .303 .408 Average Currant -with High dBA Setting (99 dBA) 12.0 VDC 223 256 Voltage 1Sed 30cd 75cd 110cd 17.5 VDC 214 251 18.0 VDC .095 .142 242 .308 Voltage AS -2416C AS -2430C AS -24750 AS- 241000 24.0 VDC .088 .120 .174 224 18.0 VDC .130 .178 .357 .404 33.0 VDC .099 .120 .152 ,190 24.0 VDC .106 .135 248 277 Average Current-with Medium dBA Setting (95 dBA) 33.0 VDC .102 .131 200 245 Avenge Current - with Medium dBA Setting (95 dBA) 16.0 VDC .081 .128 .225 298 - Voltage AS -2415W AS- 241575W As -2430W AS -2475W As- 24110W 24.0 VDC .088 .105 .157 207 18.0 VDC 089 .108 .140 224 276 33.0 VDC .088 .090 .119 .157 ' - - 24.0 VDC .072 .083 .105 .156 .183 Average Current-with Low dBA Setting (90 dBA) 33.0 VDC .087 A77 A92 .130 .158 18.0 VDC .077 .119 .222 .294 Voltage AS-1215W AS- 121575W 24.0 VDC .060 .090 .142 200 80 VDC 251 .354 33.0 VDC .055 .081 .109 .147 12.0 VDC .171 217 17.5 VDC .147 .182 Table 3: Average Current • (AMPS) Voting. AS-2415C AS -24300 AS-2475C AS- 241090 Series AH- 24-RAN & WP 18.0 VDC .116 .164 .339 .389 VOLTAGE High Medium Low 24.0 VDC .091 .120 228 258 16.0 VDC .035 .020 .014 33.0 VDC .079 .103 .179 217 24.0 VDC .041 .024 .017 Average Current -with Low dBA Setting (90 dBA) 33.0 VDC .053 .030 .021 Voltage AS -2415W AS- 241575W AS -2430W A8-2475W AS- 24110W - - 18.0 VDC .088 .103 .135 218 271 24D VDC .064 .077 .098 .149 .177 SYNC MODULES / POWER SUPPLY 33.0 VDC .058 .087 .084 _ .117 .148 Average Current Voltage AS -1215W AS-121575W Model Number Order Code Input Voltage (AMPS) @ 24 Mounting (VDC) VDC Opltpns•• 8A VDC 238 .348 12.0 VDC .158 .194 SM- 1224 -R• 6369 24 .025 W 17.5 VDC .132 .182 Voltage AS-2415C AS -2430C AS -24750 AS- 241000 05M- 1224.8. 6374 24 .038 W 16.0 VDC .112 .160 232 .382 PS- 12124.8 ° 8114 120 VAC 26.0 VDC .082 .113 219 .252 33.0 VDC .089 .095 .164 207 #SM Sync Module is rated for 3.0 amperes Q 24 VDC. • Average Current per actual Wheelock Production Testing at listed ##DSM Sync Module is rated for 3.0 amperes per circuit. The maximum VDC. For Rated Average and Peak current across UL regulated number of interconnected DSM modules is twenty (20). Refer to Data Sheet voltage range for both Filtered DC and unfiltered VRMS, see S3000 or Installation Instructions (P83123 for SM and P83177 for DSM). Installation Instructions. ###Refer to Data Sheet S9001 or Installation Instructions P83862 for PS- 12/24 -8 Power Supply. •• Refer to Data Sheet S7000 for Mounting Options. • i,� " ! P :1A a R � s d l +� � 'y� 1 ♦. �; rE,A I _ M / . + 1 �r _ A . / . _.. `, . Fire Alarm Systems Helping People Take ActionTM t °RING � TM SERIES RSS &RSSP SINGLE SP// , C FI & MULTI - CANDELA STROBES A Family of Multi- Candela Appliances' & STROBE PLATES D C DESCRIPTION _ C.' , Wheelock's patented Series RSS Strobe Appliances and `_ Series RSSP Strobe Plates have lower current draw and a,' t p ,`, Zero Inrush while maintaining outstanding performance, , _ - ��� reliability and cost effectiveness. These versatile Series RSS Series RSSP appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 15/75cd or -, ; •` Wheelock's patent pending Multi- Candela strobe with field 15 • �3C selectable candela settings of: 15, 30, 75 or 110cd. j - 1 J Ceiling mount models are available in 15, 30, 75 or 100cd intensities. Multi - Candela Indicator (bottom of Strobe Lens) All models may be synchronized when used in Features conjunction with the Wheelock SM, DSM Sync Modules • Approvals include: UL 1971, New York City (MEA), or the PS- 12/24 -8 Power Supply with Wheelock's Califomia State Fire Marshall (CSFM), Pending: Patented Sync Protocol. Synchronized strobes can Factory Mutual and Chicago (BFP). eliminate possible restrictions on the number of strobes • ADA/NFPA/ANSI compliant. in the field of view. Wheelock's synchronized strobes • Meets OSHA 29 Part 1910.165. offer an easy way to comply with ADA recommendations • Wall mount models are available with Field conceming photosensitive epilepsy as well as meeting Selectable Candela Settings of 15, 30, 75 or the requirements of NFPA 72 (1999). 110 cd. (Multi- Candela models) or 15/75cd. • Ceiling mount models are available in 15, 30, 75 Wheelock's Series RSS Strobes employ a Patented or 100cd. Integral Strobe Mounting Plate that can be mounted to a • Low current draw with temperature compensation single gang, double gang, 4" square, 100mm European to reduce power consumption and wiring costs. backboxes or the SHBB surface backbox. If the flush • Strobes produce 1 flash per second over the regulated backbox has side or top space between it and the voltage range. finished wall, the NATP (Notification Appliance Trimplate) • 12 and 24 VDC models with wide New UL "Regulated may be used. It provides an additional .65" of trim for the Voltage" using filtered (DC) or unfiltered VRMS input Appliance. An attractive cover plate is provided for a dean, voltage. finished appearance on all models. • Wall Mount or Ceiling Mount models. • Synchronize with Wheelock SM, DSM or PS- 12/24 -8 The Series RSSP Multi- Candela Strobe Plates are a cost Power Supply with Wheelock's built -in sync protocol. effective way to retrofit required strobe appliances to bells, • ZERO Inrush above Peak. homs, chimes, multitones or speakers and easily mounts • Compatible with all Wheelock 2 -Wire products. to standard 4" backboxes or for surface mount use with • Fast installation with IN /OUT screw terminals Wheelock's SBL2 surface backbox. using #12 to #18 AWG wire. Copyright 2000 Wheelock, Inc. All rights reserved. NO*E: All CAUTIONS and WARNINGS are Identified by the symbol ih,. All warnings are printed In bold capital letters. AANARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, • SPECIFYINJOR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPUCATION, INSTALLATION ANDIOR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY,DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. General Notes • Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA -72 (1999) specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL 1971. • Series RSS & RSSP Strobe products are listed under UL 1971 for indoor use with a temperature range of 32° F to 120° F (0° C to 49° C) and maximum humidity of 85%. • "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range ". Table 1: Specifications & Ordering Information - Multi - Candela Models - WALL MOUNT Order Input Regulated Strobe Average Current • Model Code Voltage Voltage Range Candela (CD) VDC VDC/FWR 15cd 30cd 75cd 110cd Mounting Options .. RSS - 24MCW -FR 9400 24 16.0 - 33.0 15/30/75/110 .047 .081 .128 .166 B,D,E,F,G,H,J,N,O,R,X RSS - 24MCW -FW 9401 24 16.0 - 33.0 15/30/75/110 .047 .081 .128 .166 B,D,E,F,G,H,J,N,O,R,X RSSP - 24MCW -FR 9402 24 16.0 - 33.0 15/30/75/110 .047 .081 .128 .166 D,E,Z Table 2: Specifications & Ordering information - Single Candela Models Order Input Regulated Strobe Average ' Mounting Options •• Model Code Voltage Voltage Range Candela Current VDC VDC/FWR SERIES RSS STROBES - WALL MOUNT RSS- 2415W -FR 7470 24 16.0 - 33.0 15 .051 B,D,E,F,G,H,J,N,O,RX RSS- 241575W -FR 7471 24 16.0 - 33.0 15 (75 on Axis) .065 B,D,E,F,G,H,J,N,O,R,X RSS- 2430W -FR 7472 24 16.0 - 33.0 30 .081 B,D,E,F,G,H,J,N,O,RX RSS- 2475W -FR 7473 24 16.0 - 33.0 75 .133 B,D,E,F,G,H,J,N,O,RX RSS- 24110W -FR 7474 24 16.0 - 33.0 110 .161 B,D,E,F,G,H,J,N,O,R,X RSS- 1215W -FR 7475 12 8.0 -17.5 15 .123 B,D,E,F,G,H,J,N,O,R,X RSS- 121575W -FR 7476 12 8.0 - 17.5 15 (75 on Axis) .170 B,D,E,F,G,H,J,N,O,RX SERIES RSS STROBES - CEILING MOUNT RSS- 2415C -FW 7482 24 16.0 - 33.0 15 .072 B,D,E,F,G,H,J,N,O,R,X RSS_2430C -FW 7483 24 16.0 - 33.0 30 .102 B,D,E,F,G,H,J,N,O,R,X Note: Models are available in either RSS- 2475C -FW 7484 24 16.0 - 33.0 75 205 B,D,E,F,G,H,J,N,O,R,X Red or White. Contact Customer Service for RSS- 24100C -FW 7485 24 16.0 - 33.0 100 .238 B,D,E,F,G,H,J,N,O,R,X Order Code and Delivery. SERIES RSSP STROBE PLATES - WALL MOUNT RSSP- 2415W -FR 7792 24 16.0 - 33.0 15 .051 D,EZ • Average Current per actual RSSP- 241575W -FR 7793 24 • 16.0 - 33.0 15 (75 on Axis) .065 D,EZ Wheelock Production Testing at RSSP- 2430W-FR 7794 24 • 18.0 - 33.0 30 .081 D,EZ Listed VDC. For Rated Average RSSP-2475W-FR 7795 24 16.0 - 33.0 75 .133 D,EZ and Peak current across UL regulated voltage range for both RSSP- 24110W-FR 7796 24 16.0 - 33.0 110 .161 D,EZ Filtered DC and unfiltered VRMS, RSSP- 1215W -FR 7797 12 8.0 - 17.5 15 .123 0,E,2 see Installation Instructions. " Refer to Data Sheet S7000 for RSSP 121575W - FR 7798 12 8.0 - 17.5 15 (75 on Axis) .170 D.EZ Mounting Options SYNC MODULES / POWER SUPPLY Table 3: Audibles /Speakers for RSSP Strobe Plate average Product Series Model Number Order Input Voltage Cunent Mounting Code (VDC) (AMPS) @ Options" zawc Multitone Appliances AMT, MT SM- 12124 -R' 6369 24 .025 W Horns AH, NH DSM- 12/24 -R" 6374 24 .038 W Motor Bells MB - G6 /G10 PS 1224$"• 8114 120 VAC Speakers ET-1010/1080, E70, ET70 # SM Sync Module is rated for 3.0 amperes @ 24 VDC. Chimes CH70 ## DSM Sync Module is rated for 3.0 amperes per circuit. The maximum number of interconnected DSM Modules is twenty (20). Refer to Data Sheet S3000 or Installation Instructions (P83123) for SM and P83177 for DSM). ### Refer to Data Sheet S9001 or Installation Instructions P83862 for PS- 12/24 -8 Power Supply.