Loading...
Report 2c— C 1 A +K -A'TCa 2;4 � z R'alpltlk,Evaatluatlon Saf A sessrnentFo , r � , _: :r �s�..' � *":F,.,_...c.a..5 .��.�....�. Inspection Inspector ID: iS1 fj, / A %J Inspection date and time: /1 /a4‘ a. UCJ ❑ Am RPM Affiliation: (' 1 Tl( U A.. _ Areas inspected: J Exterior only ❑ Exterior and interior Building Description Type of Construction Building name: PM. T = wy •r ' ❑ Wood frame ❑ Concrete shear wall Address: /5"(-.o - - 1 5'705 5 L . ■ 7a N ` AWL- ❑ Steel frame ❑ Unreinforced masonry Tilt•up concrete ❑ Reinforced masonry ❑ Concrete frame ❑ Other: Building contact/phone: Number of stories above ground: below ground: Primary Occupancy Approx. "Footprint area" (square feet): D.D ❑ Dwelling Commercial ❑ Government ❑ Other residential ❑ Offices ❑ Historic Number of residential units: ❑ Public assembly El Industrial ❑ School Number of residential units not habitable: ❑ Emergency services ❑ Other: Evaluation Estimated Building Damage Investigate the building for the conditions below and check the appropriate column. (excluding contents) Observed Conditions: Minor /None Moderate Severe ❑ None Collapse, partial collapse, or building off foundation ❑ ❑ ❑ 0 -1 % Building or story leaning ❑ ❑ ❑ ❑ 1 -10% Racking damage to walls, other structural damage ❑ ❑ ❑ ❑ 10 -30% Chimney, parapet, or other falling hazard ❑ ❑ ❑ 30 -60% Ground slope movement or cracking ❑ ❑ ❑ ❑ 60 -100% Other (specify) ❑ ❑ ❑ ❑ 100% Comments: aA x► - -rNc 4 .Jua r►{ ) O :>f rz6_ i4A ColinkF t7 fae•in Pa AC `;it L,; ni t_ To i3Ae / Will r Posting Choose a posting based on the evaluation and team judgment. Severe conditions endangering the overall building are grounds for an Unsafe posting. Localized Severe and overall Moderate conditions may allow a Restricted Use posting. Post INSPECTED placard at main entrance. Post RESTRICTED USE and UNSAFE placards at all entrances. ❑ INSPECTED (Green placard) ❑ RESTRICTED USE (Yellow placard) WINSAFE (Red placard) Record any use and entry restrictions exactly as written on placard: /rt.../- ST2t,„:T+.t r F ?U.ST IN rJ 5AY E DAtui. , & TA PL ?L& ALO4Vea $t, S CF ' B k. TILLf y, Further Actions Check the boxes below only if further actions are needed. ❑ Barricades needed in the following areas: Detailed Evaluation recommended: Structural ❑ Geotechnical ❑ Other: ❑ Other recommendations: _ Comments: C r)r1c 1- f' t T u fAL &V AL- IA A ; ,rOAJ `}2 LcitA .n • o Copyright 1995- 07,Apptied Technology Council. Permission is granted for unlimited,non•exchrsive. t n• commercial use and distribution of ATC evaluation forms, provided that this Copyright Notice appears on all copies and the Applied Technology Council name shall not be used in any advertising or publicity of Licensee product. Permission h further subject to the following conditions:11) Licensee does not reprint. repackage or alter this form for sale or license; and 121 no material gain or financial profit is to be made horn any sale or license of this form. Placards may be used without restiictions for their intended use as building postings. All rights not specifically granted to Licensee are herein reserved by ATC.