Permit V CITY OF T'IGAR� , ' BUILDING PERMIT PERMIT #: BUP2007 -00092 . COMMUNITY DEVELOPMENT DATE ISSUED: 3/5/2007 T[G 13125 SW Hall Blvd., Tigard, OR 97223 503.639.41 PARCEL: 2S112DC -00100 SITE ADDRESS: 15675 SW 72ND AVE ZONING: I -L SUBDIVISION: OREGON BUSINESS PARK III LOT: 002 JURISDICTION: TIG PROJECT: NIKE GOLF Project Description: Steel components to overhead crane system. REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: ALT FIRST: sf N: S: E: W: TYPE OF USE: COM SECOND: sf PROJECT OPENINGS? TYPE OF CONST: UNK sf N: S: E: W: . OCCUPANCY GRP: Fl TOTAL AREA: 0 sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: BASEMENT: sf AREA SEP. RATED: STOR: HT: ft GARAGE: sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: SMOK DET: DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : HNDICP ACC: BEDRMS: BATHS: IMP SURFACE: PRO CORR: PARKING: VALUE: $ 26,312.00 Owner: Contractor: PACIFIC REALTY ASSOCIATES US CRANE & HOIST, INC. VP 15350 SW SEQUOIA PKWY #300 -WMI 29375 SW KINSMAN RD = PORTLAND, OR 97224 WILLSONVILLE, OR 97070 p Contact #: PRI 503- 628 -5881 0 Phone: FAX 503 - 682 -1459 1 4 Reg #: LIC 65119 l FEES 0 Description Date Amount REQUIRED ITEMS AND REPORTS [BUPPLN] Pln Rv 2/14/2007 $193.90 [FLS] FLS Pin Rv 2/14/2007 $119.32 [TAX] 8% State Surcha 3/5/2007 $23.86 [BUILD] Permit Fee 3/5/2007 $298.20 Total $635.28 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of these rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344. Issued By: Zet...A,4...a. Permittee Signature ,t,/,,„ J 1 1 Call 503.639.4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. N.', , - CITY OF TIGARD BUILDING PERMIT e PERMIT #: BUP2007 -00092 COMMUNITY DEVELOPMENT DATE ISSUED: 3/5/2007 TIGARD 13125 SW Hall Blvd., Tigard, OR 97223 503.639.4171 PARCEL: 2S112DC-00100 SITE ADDRESS: 15675 SW 72ND AVE ZONING: I -L SUBDIVISION: OREGON BUSINESS PARK III LOT: 002 JURISDICTION: TIG PROJECT: NIKE GOLF Project Description: Steel components to overhead crane system. REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: ALT FIRST: sf N: S: E: W: TYPE OF USE: COM SECOND: sf PROJECT OPENINGS? TYPE OF CONST: UNK sf N: S: E: W: OCCUPANCY GRP: F1 TOTAL AREA: 0 sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: BASEMENT: sf AREA SEP. RATED: STOR: HT: ft GARAGE: sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: SMOK DET: DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : HNDICP ACC: BEDRMS: BATHS: IMP SURFACE: PRO CORR: PARKING: VALUE: $ 26,312.00 Owner: Contractor: PACIFIC REALTY ASSOCIATES US CRANE & HOIST, INC. 15350 SW SEQUOIA PKWY #300 -WMI 29375 SW KINSMAN RD PORTLAND, OR 97224 WILLSONVILLE, OR 97070 Contact #: PRI 503 628 - 5881 Phone: FAX 503 - 682 -1459 Reg #: LIC 65119 FEES Description Date Amount REQUIRED ITEMS AND REPORTS [BUPPLN] Pin Rv 2/14/2007 $193.90 [FLS] FLS Pin Rv 2/14/2007 $119.32 [TAX] 8% State Surcha 3/5/2007 $23.86 [BUILD] Permit Fee 3/5/2007 $298.20 Total $635.28 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of these rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344. Issued By: et,t4,..4 4 4- btA C/Z — ,,g Permittee Signature 4 ,_s--..,....c7/-m Call 503.639.4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application 15675 .50 •7 \1) A).xvc Commercial Tenant Improvement FOR OFFICE,USE ONLY 1,11 C ity o f Tigard" 9 e Permit /� p a 131 25 SW Hall Blvd., Tigard, OR 97223 P Review / l� i,--- ' `� � J O !� C Phone: 503.639.4171 Fax: 503.598.19607 E B 1 4 2007 DateBy: p 3 _,1 _0 1 Other Permit: T i G n R D Inspection Line: 503.639 D ate Read y: /r/o-7 Q B tuns: 0 See Page 2 for Internet: www.tigard -or.gov CITY OF 'j IGARD Notified/ ^ T,7 ' Supplemental Information BUILDING DIVISION � TYPE OF WORK REQUIRED DATA: 1- AND 2- FAMILY DWELLING ❑ New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ❑ Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. • ID 1- and 2- family dwelling Commercial /industrial Valuation: $ ❑ Accessory building ❑ Multi- family Number of bedrooms: ID Master builder ❑ Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: /6"t, IS - s W . '7 2 IJ i) hue- - New dwelling area: square feet City /State /ZIP: —r r �6A Qb , C 6 9/22 Garage /carport area: square feet � Suite/bldg. /apt. no.: Project name: (' i t . Covered porch area: square feet Cross street/directions to job site: 51 KO8L( 40 .. �/ 6 1.i12 Mme . Deck area: square feet ,j -5 Tv L14Q -I114r r) i • — `7 2 NP 4u ) 7y t co,) Other structure area: square feet Lge=r oF 6kr1 2 Nb (Wesr Si•OZ) REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, athd the profit for the DESCRIPTION OF WORK work indicated on this application. Valuation: $ LL, 3 i 2 F azGc -T STFgt. GowtPvnc 'T. - To 01)DilLHtpe r .'T/ n ii; si, Z 1 UZ "WE SYSTIht, Auto ANGi,v.2. . J Alija'. Existing building area: i ii , �'� square feet CD is (r fft1%r2. L - gice Sr Nc, S IV, New building area: square feet ❑ PROPERTY OWNER A TENANT Number of stories: i Name: 1,1 t $&E G Type of construction: Address: 4S(0 . (.J --72)J D t9fz • Occupancy groups: f --∎ I S — , 1-5 City /State /ZIP: ---17 Ole. q' 2. Ly Existing: Phone: ( ) Fax: ( ) New: ❑ APPLICANT ❑ CONTACT PERSON NOTICE Business name: All contractors and subcontractors are required to be Contact name: licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: jurisdiction in which work is being performed. If the City /State /ZIP: applicant is exempt from licensing, the following reasons apply: Phone: ( ) Fax:: ( ) E -mail: CONTRACTOR Business name: u L 214A,E A,00 1..a „ r �'NG • BUILDING PERMIT FEES* 1 Address: 3-9375 5,4), ICt�a,S�/► A RD . V D• x 3C4 y 70 (PAuase refer w fee schedule) City /State /ZIP: Structural plan review fee (or deposit): j 93 9 0 i41i - 5 /310�[t'tf Dom 97 0 7o �,t1rt�.5d1.. r 1 mil. ` / FLS plan review fee (if applicable): / /� . Phone: (5 ` 8 ,3 ) � 5 g Z. R i Fax: (5 B 3 8 2. — P159 ! / J CCB lic.: /9 /24 / � Total fees due upon a pplicatio n: �oS/ f Amount received: 3 )3, 0 42_, Ai Authorized signatur ih ... c: This permit application ex pires If a permit is not obtained • • within 180 days after it has been accepted as complete. Print name: j 0 u S 1¢ 7- r d am / Date: 9/1/62 * Fee methodology set by Tri- County Building Industry Service Board. I:\Building\Permits\BUP -TI- PermitApp.doc 12/27/06 440- 4613T(11 /02 /COM/WEB) • INSPECTOR'S SIGNATURES ARE NOT • Inspections Required for: liv 7 — ad0 ti. REQUIRED ON GREEN INSPECTION CARD. ✓ Code Inspection Description PASS Date By ✓ Code Inspection Description PASS Date By BUP - Building Permit ELC - Electrical Permit 405 Excavation 105 Underground/slab cover 410 Fill 110 Temporary electrical service 415 Grading 115 Electrical service 205 Footing 120 Electrical rough -in 805 MFG- Structure grading/footing 125 Wall cover 210 Foundation walls 130 Ceiling cover 215 Footing drain 135 Low voltage 220 Slab 140 Sign installation 310 Crawl drain 145 A/C or heating unit circuit 225 Post/beam structural 150 Hot tub /spa/pool 230 Underfloor insulation 195 Misc. inspection: 235 Shear walls /anchors 199 Electrical final 240 Exterior sheathing 245 Firewall 250 Roof nailing ELR - Restricted Energy Permit 255 Wtr proofing basement walls 135 Low voltage 260 Tilt -up panel 195 Misc. inspection: 265 Masonry 199 Electrical final 270 Reinforcing steel (rebar) 275 Framing 810 MFG Structure set -up MEC - Mechanical Permit 280 Insulation 605 Post/beam mechanical 285 Drywall nailing 610 Gas line 287 Suspended ceiling 7 615 Mechanical rough -in 295 Misc. inspection: C? (o g,•) �n°l 620 Hydronic piping p 899 MFG- Structure final 625 Duct work 498 Grading final 630 Fire damper 299 Final inspection 635 Smoke detector shutdown 640 Exhaust hood 695 Misc. inspection: 699 Mechanical final BUP - Fire Protection System Permit 905 Sprinkler underfloor /slab PLM - Plumbing Permit 910 Sprinkler rough -in 305 Plumbing underslab 915 Fire alarm rough -in 310 Crawl drain 920 Suppression trip test 315 Post/beam plumbing 995 Misc. inspection: 320 Plumbing rough -in 998 Alarm final 322 Shower pan 999 Sprinkler final 330 Water service 335 Rain drain 340 Storm drain SIT - Site Work Permit 505 Sanitary sewer 405 Excavation 345 Culvert/catch basin 410 Fill 350 Septic tank 415 Grading 395 Misc. inspection: 205 Footing 399 Plumbing final 210 Foundation walls 215 Footing drain 420 Sprinkler supply lines SWR - Sewer Permit 495 Misc. inspection: 505 Sanitary sewer _ 498 Grading final 595 Misc. inspection: 499 Final inspection 599 Final inspection I:\Building\Inspection Cards \Forms \AOP- InspCard- Blank.doc 12/09/2005 • 6032 North Cutter Circle Suite /1480 • Nigh � ® In Portland, Oregon 97217 r P SI ® .To Build On Phone:503- 289 -1778 Engineering • Consulting • Testing Daily Field Report Fax:503 289 - 1918 Page of I Client: Permits: Date: US Crane & Hoist BUP2007 -00092 3/8/2007 Project: Address: PSI Number: Nike Golf 15675 SW 72nd, Tigard, OR 702 - 70077 -1 General Contractor: US Crane & Hoist Subcontractor: !Weather: indoors Location(s) /Item(s): 16 3/4" anchors in powder coating room 0 New Inspection ❑ Re- Inspection V . ente ns /Testi. g . e ..oEmed.. .. # .. ) . ❑ Concrete ❑ Rebar ❑ Prestress 0 Epoxy Anchors ❑ Expansion Anchors ❑ Wood ❑ Welding/Bolting g/ g ❑ Other: 0 Special Inspectiorj Technician❑ Geotechnical ❑ At Completion ❑ In- Progress ❑ Post- Completion* p Continuous ❑ Periodic ❑ Other iietai ed Obs ry t n M e i Warki:na sh & P oceiire D scri tions�i!;;;'? ;?; Referenced Details /Drawings: Detail 03 PSI on site as required for continuous inspection of epoxy anchors, as per IBC chapter 1704.7 & Table 104.3. Performed continuous visual inspection of (16) 3/4" threaded anchors installed in 7/8" holes, with 4" embedment. Contractor furnished an RFI response from engineer approving the use of Redhead *Epcon A7 in place of Hilti Hy150 (attached). Holes were brushed & blown clean prior to installation. Anchors were installed in conformance with approved plans, revisions & applicable codes. * Expiration date verified, prior ti use, ICBO # ER5560. Non - Conformance # NONE Parties Notified: 0 General Contractor ❑ Subcontractor ❑ Architect ❑ Engineer ❑ Owner ❑ Other: ❑ Standby Time: To the best of my knowledge, the work inspected above was in accordance with the building department approved design drawings, specifications and applicable workmanship provisions of the International Building Code: ❑ Except As Noted ❑ Not Applicable p pp ❑Unapproved Drawings /Plans /Materials ❑ NCR Issued ❑ Non - Compliance ❑ Requires Engineers Acceptance (RFI) ❑ Reinspection Required Inspector (print): ID Number Kevin Larkin 1085919 Inspector Signature: Jobsite Representative Signature: Such inspection and testing shall not relieve the contractor of its obligations to the construction contract, approved permit documents and the State Building Code. • • . -MAH-i F:i: : FROM:ANDEng ENGNEEF,ING FAX:')326:3421 EAGE 1 ..--..-. . • I. , 4,-1 , c,NDERSON F ... _ ENGINEFRING , 77 . . .. 1 ! . - ......_ , , r r.. - I.g..3... • ri.... . . • . . , DATE: March 2. 2007 : TO: John Stratton • US Crane and Hoist • Wilsonville, OR Re: Substitution of Adhesive Anchors Nike Gulf — 2 ton Runway System Dear John. The "Redhead" Epcon Al Adhesive system is an acceptable alternative for the "I I ilti • HY-150 Adhesive for this specific application. Please call if you have any questions. • Sincerely. — : Eric E. Anderson. P.E. 1 • • ERIC E. ANDERSON P.F. 1092 S. Rec St. . Canby, OR 97013 • Office 503.263.32S0 • Fax 503.263.3-121 E-mail: cricgandersoci-engmeering.com fps Information • /� a To Build On Engineering • Consulting • Testing TESTED FOR: US Crane and Hoist PROJECT: Nike Golf Attn: Bryan Morris PERMIT NO.: BUP2007 -00092 29375 SW Kinsman Road Wilsonville, Oregon 97070 PROJECT SITE: 15675 SW 72 " Avenue Tigard, Oregon DATE: March 15, 2007 REPORT NO.: 702 - 70077 -2 INSPECTION TYPE(S): Epoxy Anchors, Structural Steel Erection (continuous) REMARKS: On this date a PSI representative was at the above referenced site to perform special inspections as requested or required in accordance with job specifications, IBC, and applicable codes. PSI representative was on site as requested at Nike Golf to provide special inspection of structural steel related work on the two ton crane installation. The following is noted: I. Witnessed the installation of the ' x 2 '/2 A325 bolts. All bolts were tensioned by the turn of the nut method and conform with the ICC section 1704 and detail requirements. 2. Witnessed the installation of four 5/8" all thread epoxy anchors at tie in to wall south, west, and east Kenway columns. Minimum embedment of 7 ''/2" achieved, Red Head Epcon A7 epoxy used. Installation conforms with ICBO ER5560 and detail requirements. To the best of my knowledge, the work was in accordance with the building department approved design drawings, specifications, and applicable workmanship provisions of the IBC. INSPECTOR: R. McIntire, ICC 0876684 -85 Respectfully submitted, Profession Service Industries nc. Jol Eakntan Construction Services JE/jb c: Nike Golf These test /inspection results relate only to the specific test locations noted. PSI is not responsible for any other location or elevation. Reports may not be reproduced, except in fill, without written permission of PSI. 6032 N Cutter Circle, Suite 480 Portland, Oregon 97217 Phone (503) 289 -1778 Fax (503) 289 -1918 1 • • . . jet_ =oZ _ �G1�_ ,✓ • .' &/•/-/ -'1' (2 7') W. AiikL"' 5 . • 5 5 - .7Ze,/ A - _ _ ,V u,4 �..- ,.. X4 1 , _ . • . . .-/) ..(40-y-... • _. .. . . • :__, . . • . , . : ., i4-1 • , l I .. N bti:::5•1' . r?r t:e _ 4 '; /47/. . . . . : : : __ _. di 4 1 • - - -- ' 1 - • ..1. 1 I • • • 1 i 51 q Building Division Plan Submittal Requirement Matrix T I G A R D Commercial & Multi- Family - New, Additions or Alterations Type of Submittal # of Plans (Includes new, additions and alterations.) Required at Submittal Demolition Permit 2 (site plan required showing location and square footage of all buildings to be demolished) Site Work 2 (must include location of all accessible parking) Plumbing (site utilities) 2 Building 1* Fire Protection System 2 ** Mechanical 2 Plumbing (building fixtures) 2 Electrical 2 Plan review is dependent upon submittal of a completed application and plans. After plan review approval, the Plans Examiner will contact the applicant to request additional sets of plans for distribution purposes (for contractor, City of Tigard, Washington County, and Tualatin Valley Fire & Rescue) * For over -the- counter commercial tenant improvements, submit 2 sets of plans. ** "New" fire protection systems require that plans bear the original seal of an Oregon licensed fire suppression engineer, or NICET level "3" technicians. I: \Building \Permits \BUP- TI- PermitApp.doc 03/23/06