Loading...
Permit ii , C ITY OF T MECHANICAL PERMIT 41 4 . DEVELOPMENT SERVICES PERMIT #: MEC2003 -00600 " �= 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 DATE ISSUED: 10/15/03 PARCEL: 2S112DC -00100 SITE ADDRESS: 15605 SW 72ND AVE SUBDIVISION: OREGON BUS. PARK III ZONING: I -L BLOCK: LOT: 002 JURISDICTION: TIG CLASS OF WORK: ALT FLOOR FURN: EVAP COOLERS: TYPE OF USE: COM UNIT HEATERS: VENT FANS: OCCUPANCY GRP: B VENTS W/O APPL: VENT SYSTEMS: STORIES: 1 BOILERS /COMPRESSORS HOODS: FUEL TYPES 0 - 3 HP: 1 DOMES. INCIN: ELE 3 - 15 HP: COMML. INCIN: MAX INPUT: BTU 15 - 30 HP: REPAIR UNITS: FIRE DAMPERS ?: 30 - 50 HP: WOODSTOVES: GAS PRESSURE: 50 + HP: CLO DRYERS: FURN < 100K BTU: AIR HANDLING UNITS OTHER UNITS: FURN > =100K BTU: <= 10000 cfm: > 10000 cfm: GAS OUTLETS: Remarks: New Rooftop unit. Value: $5000.00 Owner: FEES PACIFIC REALTY ASSOCIATES Description Date Amount 15350 SW SEQUOIA PKWY #300 -WM I [MECH] Permit Fee 10/15/03 $72.50 PORTLAND, OR 97224 [TAX] 8% StateTax 10/15/03 $5.80 [MECPLN] Plan Rev 10/15/03 $18.12 Phone: Total $96.42 Contractor: PROTEMP ASSOCIATES INC 9788 SE 17TH AVE PORTLAND, OR 97222 REQUIRED INSPECTIONS Phone: Cooling Unt Insp hone: 233 6911 Duct Inspection Reg #: LIC 38868 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable Taws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted in the Oregon Utility Notification Center. Those rules are set forth in OAR 952 -001 -00 Issued By: 1‘., Permittee Signature: _ '. __ Call (503) 639 -4175 by 7:00 P.M. for inspections needed e next l day II - Mechanical Permit Application . Received Mechanical ' Date/By: � FOR OF USE ONLY 7 / 3 12,11 Permit No.: tYvf-r 3O3 -06 (pct City of Tigard Planning Appro al Building foul , oz03.-1 •J g Date/By: Building No.: 13125 SW Hall Blvd. Plan Review Other Tigard, Oregon 97223 - ' Date/By: JO '/503 1}$ Permit No.: Phone: 503- 639 -4171 Fax:.,503- 598 -1960 Post Review Land Use 40,03, A Date/By: Case No.: rn Inteet: www.ci.tigard.or.us % • . 1 f l� Contact Juris.: See Page 2 for 24 - hour Inspection Request: 503 639 =4175 - Name/Method: �` �[ � `1 Supplemental Information. • TYPE OF WORK COMMERCIAL FEE* SCHEDULE - USE CHECKLIST ❑ New construction ❑ Demolition Mechanical permit fees* are based on the total value of the work Addition/alteration/replacement ❑ Other: performed. Indicate the value (rounded to the nearest dollar) of all CATEGORY OF CONSTRUCTION mechanical materials, equipment, labor, overhead and profit. ❑ 1 & 2- Family dwelling „2/ ommercial/Industrial Value: $ c 42 See Page 2 for Fee Schedule ❑ Accessory Building ❑ Multi- Family RESIDENTIAL EQUIPMENT /SYSTEMS FEE* SCHEDULE Description 1 Qty 1 Fee(ea.) 1 Total ❑ Master Builder ❑ Other: Heating/Cooling JOB SITE INFORMATION and LOCATION Furnace - add -on air conditioning ** 14.00 Job site address: is 5' 5 Dv 70( 41 0 Gas heat pump 14.00 Suite #: 1 Bldg. /Apt. #: Duct work 14.00 Project Name: s (/jL:k/ Hydronic hot water system 14.00 Residential boiler Cross street/Directions to job site: (for radiator or hydronic system) 14.00 Unit heaters (fuel, not electric) (in wall, in -duct, suspended, etc.) 14.00 Flue/vent (for any of above) 10.00 Subdivision: Lot #: Repair unit 12.15 Tax map/parcel #: Other Fuel Appliances Water heater 10.00 DESCRIPTION OF WORK Gas fireplace 10.00 / - .4„w ,4 /JAI/ T 4•. s ✓d (�.s78' Flue vent (water heater /gas fireplace) 10.00 -x i .5 11 /ii. [OL/C7 -, Log lighter (gas) 10.00 Wood/Pellet stove 10.00 Wood fireplace /insert 10.00 Chimney/liner /flue /vent 10.00 PROPERTY OWNER 1 ❑ TENANT Other: 10.00 _ / �"I J Environmental Exhaust & Ventilation Name: � iF /� =� L / / Range hood/other kitchen equipment 10.00 Address: Clothes dryer exhaust 10.00 Cit /State /Zip: Single duct exhaust Phone: 6„z y . c,3 ® e Fax: (bathrooms, toilet compartments, ❑ APPLICANT ❑ CONTACT PERSON utility rooms) 6.80 Name: Attic /crawl space fans 10.00 Address: Other: 10.00 Fuel Piping City /State /Zip: * *($5.40 for first 4. $I.00 each additional) Phone: Fax: Furnace, etc. *' Gas heat pump ** E -mail: Wall/suspended/unit heater ** CONTRACTOR Water heater •* Business Name: P4 aT p Fireplace ** Address: 9 2 sE' - 7 ,vG Range *: City /State /Zip: / -7z.sA � rf7/' '7 77 Clothes dryer (gas) •* Phone: a 33•,9// Fax: a3. .9 Other: ** CCB Lic. #: 3e_,-rs' Total: Authorized 04703 Mechanical Permit Fees* Signature: � =1 _ Date: % Subtotal: $ Minimum Permit Fee $72.50 $ 7r. ,s--0 C/ZZ. ►y /, 7 Plan Review Fee (25% of Permit Fee) $ 1$, i a- (Ple print name) State Surcharge (8% of Permit Fee) $ 5 TOTAL PERMIT FEE $ 0/ 1p . `7/ Notice: This permit application expires if a permit is not obtained within *Fee methodology set by Tri- County Building Industry Service Board. 180 days after it has been accepted as complete. •*Site plan required for exterior A/C units. i:\Dsts\Permit Fomu\MecPermitApp.doc 01/03 Mechanical Permit Application - City of Tigard Page 2 - Supplemental Information Commercial Fee Schedule: TOTAL VALUATION: PERMIT FEE: $1.00 to $2,000.00 Minimum fee $72.50 $2,001.00 to $5,000.00 $72.50 for the first $2,000.00 and $2.30 for each additional $100.00 or fraction thereof, to and including $5,000.00. $5,001.00 to $10,000.00 $141.50 for the first $5,000.00 and $1.80 for each additional $100.00 or fraction thereof, to and including $10,000.00. $10,001.00 to $50,000.00 $231.50 for the first $10,000.00 and $1.35 for each additional $100.00 or fraction thereof, to and including $50,000.00. $50,001.00 to $100,000.00 $771.50 for the first $50,000.00 and $1.25 for each additional $100.00 or fraction thereof, to and including $100,000.00. $100,001.00 and up $1,396.50 for the first $100,000.000 and $1.10 for each additional $100.00 or fraction thereof. All New Commercial Buildings require 2 sets of plans. i:\Building\Permit Forms \MecPermitAppPg2 09- 01- 03.doc CITY OF TIGARD 24 -Hour • BUILDING Inspection Line: (503) 63 175 INSPECTION DIVISION Business Line: (503) 6 1 MST BUP Received / Date Requested / 1 AM PM BUP Location l S' 0 5 7' .1'1 Suite MEC 3 -006 �d Contact Person /�/ �'L� Ph ( ) 3e 7 —0 8 / c/ o PLM Contractor - �� ) Ph ( ) 3 C� — 86 SWR BUILDING Tenant/Owner 4W I U ► E.Av ELC Footing ELC Foundation Access: Ftg Drain ELR Crawl Drain Slab Inspection Notes: SIT Post & Beam Shear Anchors Ext Sheath/Shear Int Sheath/Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Other: Final r PASS PART FAIL % f PLUMBING t� Post & Beam Under Slab + Rough Service Water Service Sanitary Sewer rfr/P, Rain Drains Catch Basin / Manhole Storm Drain Shower Pan Other: Final PASS PART FAIL MECHANICAL Post & Beam c„0 Rough -In Gas Line �J Smoke Dampers ma_ PAS PART FAIL CTRICAL Service Rough -In UG/Slab Low Voltage Fire Alarm Final Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd. PASS PART FAIL SITE Please call for reinspection RE: Unable to inspect no access Fire Supply Line /► ` ADA Date l Inspector Ext Other: Final DO NOT REMOVE this inspection record from the Job site. PASS PART FAIL