Loading...
Plans ii�1ec zd —0Li 6k Page Number of REZN ®R° Power Vented, Low Static Axial Fan Unit Heaters for Residential and Commercial /Industrial Use ` Model UDAP Sizes 30 -125 approved for utility applications such as residential garages under CSA International Requirement 0 10.96 - U.S. and CR96 -0005 - Canada t tY/ Dam !x ✓ 1}t1.1.04. , �Rp� `20 9p �? • 11 (-----: p ' 3 : i Q-1 onj WHO. I t " CSA 2.6b ANSI Z83.8b DESCRIPTION Reznory V3 Series Model UDAP gas -fired unit heaters are available in 14 sizes ranging from 30,000 to 400,000 BTUH gas input. Sizes 30 -125 are approved for residential application. All sizes are approved for commercial/ industrial installations. Model UDAP heaters are designed for 82 -83% thermal efficiency and are approved for installation in the United States and Canada by the Canadian Standards Association (CSA). Reznor V3 Series unit heaters have a refreshing new appearance with a glossy white cabinet finish and less visible hardware. Each size cabinet is easily suspended from either 2 or 4 suspension points. Or, an optional hanger kit for Sizes 30 -125 allows for ceiling mounting. The low voltage terminal strip on the outside of the cabinet makes connecting control wiring easy with no panels to remove. The addition of a "G' terminal to the strip, along with the new design of the circuit board, allows for fan only operation (without adding relays). All units have a factory installed gas line nipple to the exterior of the cabinet for easy gas service connection. The preeminent new intemal feature is the Tcone2 ® heat exchanger and single bumer combustion system. - Other standard features include a single -stage gas valve, multi -try direct spark ignition with 100% lockout, pres- sure switch to verify vent flow, resiliently isolated venter motor, venter wheel with improved housing, resiliently isolated axial fan and motor assembly, and a high temperature limit control. Sizes 30 -125 also include a flame rollout safety switch. Operation is controlled through an integrated circuit board. The circuit board monitors healer operation and has LED diagnostic indicator lights to identify abnormalities in control functions. The V3 Series unit heaters are designed to provide all the features you expect in a Reznor heater plus im- proved efficiency, easier installation, and a new look - both inside and out. Look for the unique white unit with no visible front and bottom hardware, deep red louvers, black side handle, and angled corner to know you have a genuine Reznor unit by Thomas & Betts. STANDARD FEATURES • Sizes 30 -125 certified for residential heating application • Sizes 30-400 certified for commercial/industrial heating application • 82-83% Thermal efficient - TOP in its class! CITY OF TIGARD • 50 -60 °° F Rise range • TCORE titanium stabilized aluminized steel heal exchanger i �../ • Patented** TcoRe2' � single burner combustion system including a e •••• ...• 1 • 115/1/60 Supply voltage Conditionally Approved „. [ j • 115 Volt open fan motor with internal overload protection See Letter to: Follow [ • Transformer for 24 -volt controls • Integrated circuit board with diagnostic indicator lights Attached k a y �t' ' '-- • Multi -try direct spark ignition with 100% lockout Permit Numbe . v r0 r' .. M - I1 , • Fan relay (included on the circuit board) ' s r i .'�,�� �.�. • Single -stage natural gas valve (field adjustable for operation to 9 t>3r , :: =, = ' . . `1 • Vibration/noise isolated fan and venter motors - designed for loBt{oise op ;+ y•� tl; �� D ate: r • 2 -pt and 4 -pt Suspension - standard on all sizes 77 • External terminal strip for 24 -volt wiring • External gas connection • Full fan guard - engineered for safety • Improved cabinet design with less visible hardware and a NEW Reznor appearance OPTIONAL FEATURES - • Single- stage, propane gas valve (field adjustable for operation to 9.000 ft. elevation) FACTORY INSTALLED • Two-stage natural gas or propane gas valve - Sizes 60 -400 • 409 or 316 Stainless steel heat exchangers • 208 or 230 Single phase voltage • Totally enclosed fan motor (Sizes 30 -250, 115V only) • Common venting with other gravity vented Category I appliance(s) (Sizes 30 -100) U.S. Patent No. 6.889,686 . Form RZ -C -UH (Version H) Page 8 OFFICE COPY Page Number of OPTIONAL FEATURES - • Vent cap FIELD INSTALLED • Thermostat • Thermostat guard with locking cover • Vertical louvers - new design • Downturn nozzle kits - new design • Gas conversion kits (natural and propane) • Master /Slave controls for zoning up to six units • Ceiling suspension kit - Sizes 30-125 • Hanger kits for 1" pipe • Stepdown transformer (for 230/3 and 460/3 supply voltage) • Manual shutoff valves TECHNICAL DATA Model UDAP Size 30 46 60 75 100 125 150 176 200 226 260 300 360 400 Input Heating Capacity - BTUH 30,000 45,000 60,000 75,000 105,000 120,000 150,000 175,000 200,000 225,000 250,000 300,000 350,000 400,000 kW /h 8.8 13.2 17.6 22.0 30.8 35.2 43,9 51.2 58.8 65.9 73.2 87.8 102.5 117.1 Thermal Efficiency ( %) 82 83 83 83 83 83 83 83 83 83 83 83 83 83 Output Healing BTUH 24,600 37,350 49,800 62,250 87,150 99,600 124,500 145,250 166,000 186,750 207,500 249,000 290.500 332,000 Capacity" kW /h 7.2 11.0 14.6 18.3 25.6 29,2 I 36.4 42.5 I 48.6 I 54.7 60.8 72.9 I 85.1 97,2 Gas Connection Natural 1/2 1/2 112 1/2 1/2 1/2 1/2 1/2 1/2 3/4 314 3/4 3/4 3/4 (inches) a Propane 1/2 I 1/2 1/2 1/2 1/2 I 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 Vent Connection Size a (inches 4 4 4 4 4 4 5 5 5 5 5 6 6 6 diameter) Control Amps (24 volt) 1.0 1.0 1.0 • 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 , 1.0 Full Load Amps (115 volt) 1.9 2.4 2.4 3.3 3.9 5.1 3.8 3.8 4.6 7.5 7.5 11.0 11.0 11.0 Maximum Over Current Protection 15 16 15 15 15 15 15 15 15 15 15 20 D 20 20 Normal Power Consumption 109 155 155 217 276 354 392 392 491 747 747 1086 1086 1086 (watts) Discharge Air Temperature Rise 50 65 60 60 60 60 60 60 60 60 60 60 60 60 CFM 456 629 769 961 1345 1537 1921 2242 2562 2882 3202 3843 4483 5123 Air Volume NV /minute 12.9 17.8 21.8 27.6 36.7 45.9 54.4 63.5 72,5 _ 81.8 90.7 108.8 126.9 145.1 Discharge Air Opening It' r 0.96 0.96 1.25 1.25 2.01 2.01 2.56 2.56 2.56 3.51 3.51 4.79 4.79 4.79 Area M 0.09 0.09 0.12 0.12 0.19 0.19 0.24 0.24 0.24 0,33 0.33 0.45 0.45 0.45 Output Velocity FPM 475 658 618 770 688 783 752 877 1003 820 911 802 936 1069 M/minute 145 200 188 238 196 245 229 267 306 250 278 244 285 326 Fan Motor HP E Open 0.02 0.03 0.03 0.06 1/30 1/20 1/6 1/6 1/8 1/4 1/4 1/2 1/2 1/2 Enclosed 0.06 0.06 0.06 0.06 1/4 1/4 114 1/4 1/4 1/4 1/4 1/2 1/2 1/2 Fan Motor RPM 1560 1650 1650 1550 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 Fan Diameter (inches) 10 10 12 12 16 16 18 18 18 20 20 24 24 24 Sound Level _ dBb @ 4 0 40 40 49 54 ( 55 51 52 53 56 56 59 61 62 Approximate Net lbs 54 59 67 72 96 101 172 187 187 203 216 269 294 306 Weight kg 24 27 30 33 44 46 _ 78 85 _85 92 98 122 133 139 Approximate Ship Ibs 61 66 74 79 118 123 204 y 219 219 245 257 321 346 358 Weight kg 27 30 33 , 36 54 _ 56 93 100 _ 100 111 _ 117 146 _ 157 _ 163 " CSA rating for altitudes to 2000 rt, • Size shown Is for gas connection to a single stage gas valve, not supply line size. Smeller or larger vent pipe diameters may be allowed: refer to the Venting Installation Manual. Form I -V -PV. It vent diameter is different from vent connection, reducer /enlarger; will be field- required. ° MODP e. 2.25 x (largest motor FLA) + smallest motor FLA. Answer Is rounded to the nearest commercially available arcuit breaker. • All other information in this table is based on a heater equipped with a standard 115 volt open Ian motor. Form RZ-C-UH (Version H) Page 9 DIMENSIONS Page Number of Model UDAP - ±1/16" (2mm) Size A B C 0 E F G H J K M N P Q R 30, 46 12 1/8 25 5/8 10 13 13/16 26 21 9116 5 3/16 6 1/2 2 11/16 3 7/8 17 3/8 11/16 4 5/16 13 9 9/16 60 15 1/8 25 5/8 13 13 13/16 27 21 9/16 7 7/8 6 1/2 5 112 3 7/8 17 3/8 11/16 4 5/18 13 10 1/2 76 15 1/8 25 5/8 13 13 13/16 27 5/8 21 9/16 7 7/8 6 1/2 5 1/2 3 7/8 17 3/8 11/16 4 5/16 13 10 1/2 100 23 1/8 26 5/8 21 13 13/16 28 5/8 21 9/16 14 1/2 6 1/2 8 3/4 3 7/8 17 3/8 11/16 4 5/16 13 10 1/2 125 23 1/8 25 5/8 21 13 13/16 29 3/8 21 9/16 14 1/2 6 1/2 8 3/4 3 7/8 17 3/8 11/16 4 5/16 13 , 10 1/2 150, 175. 20 1/8 38 3/16 16 2 3 42 35 3/8 8 1/2 8 1/4 5 7/16 6 1/2 25 11/16 1 3/8 8 3/16 22 3/16 16 3/8 200 - 226, 260 26 1/8 38 3/16 22 23 42 35 3/8 13 1/16 8 13/16 9 6 1/2 25 11/16 1 3/8 8 3/16 22 3/16 15 5/8 300, 350, 34 1/8 4 1 30 23 42 35 3/8 17 1/16 9 11 13/16 7 5/16 27 11/16 1 3/8 8 3/16 22 3/16 16 3/16 400 Size A 8 C D E F G H J K M N P Q R 30, 46 (308) (651) (254) (351) (660) (548) (132) (165) (68) (98) (441) (17) (110) (330) (243) 60 (384) (651) (330) (351) (686) (548) (200) (165) (140) (98) (441) (17) (110) (330) (267) 75 (384) (651) (330) (351) (702) (548) I (200) (165) 1 (140) (98) ' (441) (17) (110) (330) (267) 100 (587) (651) (533) (351) (727) (548) (368) (166) (222) (98) (441) (17) (110) (330) (267) 125 (587) (651) (633) (351) (746) (548) (368) (165) (222) (98) (441) (17) (110) (330) (267) 150, 175, (511) (970) (406) (584) (1,067) (899) (216) (210) (138) (165 200 ) (65 2) (36) (208) (564) (416) 225, 260 (664) (970) (559) (584) (1,067) (899) (332) (224) 1 (229) i (165) (652) (35) (208) (564) (397) 300,360, (867) (1,041) (762) (584) (1,067) (899) (433) (229) (300 400 ) ( 186 ) (703) (35) (208) (564) (411) N -+ M ■ R - Hanger __..._ .... ......... .... Dimension for A _ 2-pt Suspension . . P Combustion Air Inlet PandQ - R Hanger Thermostat R EAR O Connection VIEW Dimensions C TOP VIEW %.l �� N.r. for 4 - t (30 -125 Vertical; 41V p a 150-400 Horizontal) Suspension (l - 3/8 " -16 Female Thread `IW t/� „ i , all suspension points i t . J o 0 Line Voltage *. K . External Vent Connection • Inlet (connects H--► Gas (see Technical at circuit board) Connection Data for size) l i B ,I E A 0 ' F T r _ • • 1 • FRONT 0 RIGHT SIDE �� VIEW Z VIEW A c I N (Access Panel) • j CLEARANCES FROM COMBUSTIBLES Flue Non - Access To Connector Access Panel Side Bottom' Rear Size inches mm inches mm Inches mm inches mm inches mm inches mm 30-125 1 25 6 152 18 457 1 25 1 25 18 457 150-400 4 102 6 _ 152 _ 18 457 2 51 1 25 _ 18 457 `Suspend the heater so that the bottom is a minimum of 5' (1.5M) above the floor. Form RZ -C -UH (Version H) Page 10 14,01Zond HotZone Gas Aisle Series Heatelrs Specifications r-= -- w " L' q ` I ' r '' HotZone' Gas Aisle Series Heaters .mss; Gas HotZone heaters are high power, high intensity infrared , a ` , * r spot heaters that are typically used in groups, with the heaters' ` 't,, beam patterns overlapping in the long dimension to heat a 1'*" ' long thin space. Example: applications include heating a row ; 00. " " F, a _ t .:n „r x= ;..� '����° of workspaces along a conveyor belt, aisles in a warehouse or `. s' `, - r s s ,,''' a bank of checkout stations in a big box store. '. ue ... " .,_.. �< Product Number HZN35120L HZN70120L HZN110120L HZN145120L (natural gas) (natural gas) (natural gas) (natural gas) HZL35120L HZL70120L HZL110120L HZL145120L (propane) (propane) ' (propane) (propane) Lens Power 3x Spot Pattern 2:1 Oval Element Type Ceramic burner Typical Mounting 10' — 18' 13' — 23' 18' — 28' 18' — 28' Height Range z +15° Spot Size at minimum mounting 60 ft 120 ft 180 ft 240 ft height* Maximum temperature increase 27° F 35° F 27° F 36° F at minimum mounting height* Maximum temperature increase 11° F 11° F 11° F 15° F at maximum mounting height* Input Power 35,000 BTU 70,000 BTU 110,000 BTU 145,000 BTU Gas Natural gas or propane Controller Voltage 120V (24V & mV available) Dimensions 32 "x14 "x23" 32 "x21 "x23" 32 "x28 "x23" 32 "x34 "x23" Weight 48 lbs. 61 lbs. 75 lbs. 83 lbs. Standard Colors Unpainted aluminum Color Options Special order custom colors Mounting Options Ceiling or wall, chain hung Other ETL Certified for vented or unvented use out of direct rain *Temperature increase resulting from direct radiant energy. In most applications, surface heating and other affects will also raise the ambient temperature over time and add to the temperature increase. © 2009 Schaefer Ventilation All Rights Reserved .0 EFER Doc#: HZGasAisleSeriesspecs09.doc 1.800.779.3267 \ / \ FLUE -- N NN : , /\___ AGA APPROVED WEATHER CAP ih TALL CONE I 1� /‘/ FLASHING ROOF (See Arch. Dwgs STORM COLLAR M GAS LINE CONNECT T❑ PER P15-050 ROOF STRUCTURE Y C7_----1 ' 3/8" ALLTHREAD / DOUBLE NUT 1 SEISMIC QI \ \ BRACING \ UNIT HEATER NN \ N N GAS SHUTOFF PRESSURE TAP VALVE SEDIMENT TRAP/ PRESSURE TAP GAS HEATER DETAILS NTS • OVERHEAD STRUCTURE AND FIELD CONNECTIONS MUST BE ADEQUATE TO SUPPORT WEIGHT OF HEATER c-T.1 - 10 NOTE GAS MAINS AND ELECTRICAL III LINES MUST NOT CROSS 1/0 TENS❑ I CHAIN II OVER TOP OF HEATER MOUNT III II l i l III 64' CLEAR TO III C❑MBUSTIB 33" CLEARANCE TO II COMBUSTIBLE y= - - - - - - -- V l/ /I "S" HOOK ' I" WIRE DIA. 0 (CRIMP ALL "S" (9 HOOKS CLOSED) ..0 °/°°/°g7' I •Ir - 125' CLEARANCE TO COMBUSTIBLE INFRARED HEATER DETAILS NTS 1 1 1 1 1 1 , MAIN GAS LINE "S" HOOK f') 1=1 I 111 IR HEATER ! PRESSURE TAP REG. GAS SHUTOFF SEDIMENT TRAP/ VALVE PRESSURE TAP TYP, IR GAS HOOK -UP NTS / METAL ROOF ZGURT I 6. , -1 1 ...' _.. 1 .' � I.R. HEATER REFLECTOR 0 . . BURNER TUBE TYP, IR GAS SEISMIC BRACING NTS