Specifications warn -66 uz- Simplex 9245 S.W. Nimbus Avenue Beaverton, OR 97008 Sales (503) 746 -1000 Service (503) 746 -1001 Fax (503) 643 -3219 August 28, 2000 Rural Electric 5285 NE Elam Young Parkway, #A900 Hillsboro, OR 97124 ATTN: Paul Ellis SUBJECT: 72' Avenue Building Fire Alarm & Area of Rescue Equipment Submittal Dear Paul: Enclosed are data sheets describing the equipment Simplex is proposing to furnish for this project. Please refer to individual sheets for mounting options. PART # DESCRIPTION SHEET# * * * * * * * * * * * * * * * * * * * * * * * * * * * ** *PANELS & BATTERIES******* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 4010 -9101 Fire Control Panel - Addressable S4010 -0001 4010 -9810 Digital Alarm Comm. Transmitter S4010 -0001 4010 -9813 Expansion Power Supply 54010 -0001 2081 -9275 Battery (pair) - 18 Ampere Hour S2081 -0006 * * * * * * * * * * ** *IDNET ONLY ADDRESSABLE INITIATING AND ANNUNCIATION * * * * * * * * * * * * * * ** 4606 -9101 LCD Annunciator for 4010 - N2 Data S4606 -0001 4098 -9710 Detector & Base — IDNet Addressable Photoelectric S4098 -0022 4099 -9001 Addressable Manual Pull IDNet S4099 -0001 4090 -9001 IAM IDNet Addressable Module S4090 -0001 4090 -9002 Relay IAM IDNet Addressable Control S4090 -0002 * * * * * * * * * * * * * * * * * * * * * * * * * ** HARDWIRED INITIATING PERIPHERALS * * * * * * * * * * * * * * * * * * * * * * ** 2098 -9445 Heat Detector Fixed 135 w/ (2) N/O S2098 -0051 * * * * * * * * * * * * * * * * * * * * * * ** SIGNALS - STROBES / HORNS / SPEAKERS * * * * * * * * * * * * * * * * * * * * * * * ** 4903 -9417 Horn Strobe 15 CD Red Synchronized S4903-0010 4903 -9418 Horn Strobe 75 CD Red Synchronized S4903 -0010 4903 -9419 Horn Strobe 110 CD Red Synchronized S4903 -0010 4904 -9331 Strobe 15 CD Red Synchronized S4904-0003 * * * * * * * * * * * * * * * * * * * * * * * * ** MISCELLANEOUS PERIPHER. ALS * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 2088 -9010 Relay DPDT MR -201 /C In Metal Can S2088 -0010 *** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** AREA OF RESCUE **** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 2080 -9025 Area of Rescue Master Station ADA 100 2080 -9026 Area Station ADA 100 2080 -9039 Backbox for Master, Area Station N/A 2080 -9035 Cabinet for Relay Cards N/A 2080 -9040 Area Station Sign SS N/A Sincerely, Rick Welch Building Systems Representative EiSlmplex TrueAlarm Fire Alarm Controls UL, ULC Listed, FM Approved Model 4010 Fire Alarm Control Panel for NYC, MEA Approved* TrueAlarm Analog Sensors and IDNetTm Addressable Devices Features IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Up to 250 addressable TrueAlarm or IDNet points** • Four, 2 A notification appliance circuits (NACs) with solid state current protection Installation convenience features: • • Electronic modules contained on one -piece chassis • Up -front terminal blocks for wiring access • Compact NEMA 1 rated cabinet is available in beige or red and can be pre- shipped for early installation Setup, programming, and maintenance features: • Device level ground fault search, locate and isolate IIIIIIIIIIIIIIIIIII�IIIII jmIufl IIIlIIIllllllll • Auto Program, automatic module and device programming for general alarm operation 4010 TrueAlarm Fire Alarm Control Panel • TrueAlarm individual analog sensing with front panel information and selection access ** Descri •tion • "Dirty" TrueAlarm sensor maintenance alerts, service TrueAlarm fire alarm control panels have the ability and status reports including "almost dirty" to provide location accuracy for monitoring and control. • Default TrueAlarm sensor device type operation When equipped with TrueAlarm analog sensing for • Duplicate address error detection smoke and heat detection, the processing power of the control panel also has the ability to analyze conditions at • Front panel or PC programming each location to provide accurate detection with • TrueAlarm sensor peak value performance report significantly reduced maintenance costs. • WALKTESTTM silent or audible system test t The Simplex 4010 TrueAlarm Fire Alarm Control Panel • Software verification simulation mode has been specifically designed to provide addressable operation and analog detection in a cost - effective package Supports the following IDNet devices** : for application sizes that previously were considered only • Addressable manual stations appropriate for conventional zoned monitoring. • Quad -state zone adapter modules (ZAMs) for Installation and Service Ease. The 4010 mounts on a initiating device monitoring single chassis for quick installation and removal. • IDNet ground fault/short circuit isolator base for Terminal blocks are large and up -front for easy access and inspection. Optional modules are easily and quickly TrueAlarm sensors installed and programmed as required. • Quad -state line powered individual addressable The 4010 cabinet provides convenient stud markers for modules (IAMs) for initiating device monitoring and drywall thickness and nail -hole knockouts for quicker relay control mounting. Smooth cabinet surfaces are provided for Available option modules include: locally cutting conduit entrance holes exactly where required. 4010 cabinets and electronics can be ordered • Simplex 4120 Network, DACT, or City interface separately, allowing early cabinet installation. • Equipment for Suppression Release Applications Ground Fault Assistance. Ground fault problems • RS -232 ports for printers or maintenance terminal often occur during installation. The 4010 provides Class A NAC adapter module isolating circuitry and software - controlled sequencing to • isolate ground faults to specific identified locations. This • Additional power supply assistance helps the installer to accurately locate the Compatible with Simplex: wiring problem for quicker repair. • Accepted for use — City of New York Department of Buildings — MEA35 -93E. • 4009 NAC power extenders, both IDNet compatible ** Simplex TrueAlarrn analog smoke detection and IDNet addressable devices and conventional models are protected by one or more of the following U.S. Patents: 5,155.468: 5,173,683; 5.543,777; 5,400,014; 5,552,765; 5,552,763; DES. 377,460. • 4003 Voice Control Panel t Simplex WALKTEST is protected under U.S. patent # 4,725,818. 1999 Simplex Time Recorder Co. All rights reserved. S4010- 0001 -2 3/99 4010 Operator Control Summary 4010 Display Panel and WALKTESTTM Extensive Feature List. The Simplex 4010 Fire Alarm Convenient Status Information. With the locking Control Panel provides access to an extensive feature list door closed, a window allows viewing of the status that includes: display. The 4010 status panel provides a two line by 40 character, super -twist LCD information display and eight • Providing easy and powerful operator information status LED indicators as shown in the illustration below. with a logical, menu - driven display • Extensive and automatic diagnostics for From this display, the LED indicators will describe the general category of activity being displayed with the LCD maintenance reduction providing more detail. For the authorized user, unlocking • History Logs available from the LCD or capable of the door will provide access to the control switches and (optionally) being printed allow further inquiry by scrolling the display for • Software Verification, allowing detailed logic additional detail. (Refer to control panel functional programming simulation to be conducted without illustration below.) activating connected outputs WALKTESTIm Diagnostic Operation Mode. The • Control Panel (or service PC) label editing patented Simplex WALKTEST process allows a single person to perform system test. The system records test • Password access control inputs such as intentional alarms or trouble and either logs • Auto Program Quick Configuration (Quick - CFIG) the response (silent WALKTEST) or outputs a brief, of connected modules and IDNet devices for recognizable audible notification signal (audible general alarm operation to quickly get the system WALKTEST). up and running Extended Operator Control Panel Functions FIVE STATUS INDICATOR LEDs provide system status indications in addition to LCD information. LEDs flash to indicate the condition and then when acknowledged, remain on until reset. THREE PROGRAMMABLE LEDs provide custom labeling (labels insert 2 X 40 LCD READOUT, LED backlighted during normal into a pocket), the top two LEDs are conditions and abnormal operating conditions, provides selectable as red or yellow, the bottom up to 40 characters for custom label information LED is selectable as green or yellow ** SYSTEM IS NORMAL 12:02:15.4n Mon 8- Mar -99 CONTROL bj.' FlRE - •':SYSTEMr SYSTEM.; ALARM.. - .: +AC PANEL VIEW '' ALARM! 'SUPEPIRSORY' _ TROUBLE 4I, SILENCED t POWER with 4010 door ' ;t♦. t Mra, SYSTEM RESET restores closed control panel to normal when all alarmed inputs are ALARM - • SUPV TROUBLE ALARM `: SYSTEM - retumed to normal ACK ACK ACK SILENCE RESET -', 74 •.'"Extv FUNCTNN. : ENABLE C1FAR : \ FRIER \ PREVIOUS: NEXT ALARM ACK acknowledges a Fire Alarm condition, logs the acknowledge and silences the operator NINE EXTENDED FUNCTION KEYS (accessible with panel and all annunciator tone alerts door open) select and scroll through display prompts for locating additional system information, performing maintenance functions, or for front panel programming SUP ACK acknowledges system supervisory conditions, logs the acknowledge, and silences the ALARM SILENCE causes audible notification appliances operator panel and all annunciator tone alerts to be silenced, used after evacuation is complete and while alarm source is being investigated TROUBLE ACK acknowledges system troubles, logs the acknowledge. and silences the operator panel and all annunciator tone -alerts Simplex Time Recorder Co. 2 S4010- 0001 -2 3/98 IDNet Addressable Interface temperature extremes in the range from 32° F to 155° F (0° C to 68° C). This feature can provide freeze warnings IDNet Overview. 4010 addressable device or alert to HVAC system problems. communications operate via Simplex IDNet. Using a two wire circuit. individual devices such as manual fire alarm stations, TrueAlarm sensors and sprinkler waterflow To additional IDNet switches can be directly connected (or interfaced), to devices, up to 250 total IDNet to communicate their identity and status. This addressability allows the location and condition of the connected device to be displayed on the 4010 panel LCD and on system annunciators. Additionally, control circuits Quick- Connect TrueAlarm (fans, dampers, etc.) may be individually controlled by sensors with sounder Modular TrueAlarm using a relay IAM (individual addressable module) and sensor with base the 4009 IDNet NAC Extender can be controlled for local or remote NAC expansion. (Refer to individual device documentation for further details.) Capacity. A total of 250 addressable monitor and control points may be intermixed on the same pair of wires. By Supervised IAM Modular TrueAlarm sensor using Zone Adaptor Modules (ZAMs) or Individual with IDNet isolator base Addressable Modules (IAMs), conventional initiating �� devices can be connected to the IDNet circuit. IDNet Addressable Operation: The IDNet controller continuously interrogates each addressable device on the Addressable station communication channel for status condition such as: _ 4009 lDNet NAC normal, off - normal, alarm, supervisory, or trouble. N Extender Sophisticated poll and response communication WNW B._--a techniques ensure supervision integrity and allow for "T- tapping" of the circuit for Class B (Style 4) operation. Quick - Connect Monitor ZAMs and TrueAlarm sensor Relay IAMs Wiring. Up to 10, 000 total feet (3048 m) of twisted, shielded #18 AWG wire may be connected to the IDNet channel. The distance from the panel to the farthest device may be up to 2500 feet (762 m). Unshielded wire may be I _ • used in certain retrofit applications. IDNet wiring can be - • either Class B (Style 4) or Class A (Style 6) depending on the system requirements. TrueAlarm Analo • Sensors TrueAlarm System Operation. IDNet communicates 4010 Control Panel with typical IDNet Devices with TrueAlarm smoke and temperature sensors. Every four seconds, smoke sensors transmit an output value Diagnostics and Default Device Type based on their smoke chamber condition. The 4010 CPU TrueAlarm operation gives the 4010 system the ability to maintains a current value, peak value. and an average value of each sensor's output. Status is determined by automatically indicate when a sensor is almost dirty, dirty, comparing the current sensor value to its average value. and excessively dirty. The NFPA 72 (National Fire Alarm Tracking this average value as a continuously shifting Code) requirement for a test of the sensitivity range of the reference point filters out environmental factors that cause sensors is fulfilled by the each sensor. e ability to maintain shifts in sensitivity. the sensitivity level of each ssor. Programmable Sensitivity. The sensitivity of each Modular TrueAlarm sensors use the same base and sensor can be field programmed at the 4010 Control Panel different sensor types (photoelectric smoke sensor, or heat for different levels of smoke obscuration (in percent) or sensor) can be easily interchanged to meet specific for specific heat detection levels. In order to evaluate location requirements. This feature also allows intentional whether the sensitivity should be revised, the peak value sensor substitution during building construction. When is stored in memory and can be easily read and compared conditions are temporarily dusty, instead of covering the to the alarm threshold directly in percent. smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control TrueAlarm heat sensors can be selected for rate -of- panel. Although the control panel will indicate an rise detection as either 15° F (8.3° C) or 20° F (11.1° C) incorrect sensor type, the heat sensor will operate at a per minute with an independent fixed limit of 135° F default sensitivity to provide heat detection for building (57° C) or 155° F (68° C). TrueAlarm heat sensors can protection at that location. also be programmed as a utility device to monitor for Simplex Time Recorder Co. 3 S4010- 0001 -2 3/99 TrueAlarm Information Details True Alarm sensor data can be displayed on the Remote Maintenance system LCD, on a remote maintenance terminal, or Terminal (Simplex printed on a remote printer. With the proper operator model 4190 - 9006) access, a TrueAlarm Service Report can be generated to list the specific details of each TrueAlarm device. This report, as well as the Status Report below can either be i 1 • displayed on the remote maintenance terminal or captured permanently by using a remote 80 character printer. _ - RS - 232 connections, one per device The figures below illustrate the format provided on either the remote maintenance terminal or a printer. This information is available at the system LCD by identifying y .� = '■7.. 7 g rs - the specific point of interest and reading one point at a r- -,. auttttttw 4010 Fire Alarm time. Control Panel tP , Compatible RS -232 devices include the Simplex model t� '"___ -- g 4190 -9006 Terminal and the Simplex model 4190 -9007, it' 80 column. 24 pin dot matrix printer. (The 2190 -9039, Remote Printer 24 VDC, 40 column printer is compatible with the 4010 (Simplex model 4190 - 9007) for event printing only.) (Contact Simplex for information on the complete line of 4010 Fire Alarm Control Panel TrueAlarm analog sensing products) RS - 232 Connection Options TrueAlarm Status and Service Re • ort Sam • Ies Simplex 4010 Fire Alarm System Page 1 REPORT 3 : TrueAlarm Status Report 2:43:03 pm Mon 8- Mar -99 Zone Sensi- Almost Name Custom Label tivity Device Status Dirty M1 -1 ANALOG PHOTO CLEAN ROOM 0.5 % NORMAL M1 -2 ANALOG ION CLEAN ROOM 1.3 % NORMAL M1 -3 ANALOG PHOTO MAIN LOBBY 2.5 % NORMAL *YES* M1 -4 ANALOG PHOTO CONFERENCE ROOM 1 2.5 % NORMAL M1 -10 HEAT DETECTOR GARAGE 135 F NORMAL M1 -11 ANALOG PHOTO KITCHEN 3.7 % NORMAL *YES* END OF REPORT Typical TrueAlarm Status Report Information Printout and /or Maintenance Terminal Screen Simplex 4010 Fire Alarm System Page 1 REPORT 4 : TrueAlarm Service Report 2:56:09 pm Mon 8- Mar -99 Dev Alarm Avg Current/ Peak/ State Num Custom Label at: val % alarm % alarm 1 ANALOG PHOTO - CLEAN ROOM 0.5/ 83 67 68/ 1% 72/ 10% NOR 2 ANALOG ION - CLEAN ROOM 1.3/209 94 97/ 2% 101/ 1% NOR 3 ANALOG PHOTO - MAIN LOBBY 2.5/185 117 117/ 0% 125/ 42% NOR 4 ANALOG PHOTO - CONFERENCE ROOM 1 2.5/161 93 93/ 0% 93/ 0% NOR 10 HEAT DETECTOR - GARAGE 135F /253 - -- 63/ -67F 66/ 69F NOR 11 ANALOG PHOTO - KITCHEN 3.7/216 116 116/ 1% 110/ 36% NOR END OF REPORT Typical TrueAlarm Service Report Information Printout and /or Maintenance Terminal Screen Simplex Time Recorder Co. 4 S4010- 0001 -2 3/99 Standard Panel Features media modules. May be both wired, both fiber optic. or N2 Communications for Serial Annunciator one of each. Control. Control for up to 6 remote Simplex DACT, Point Reporting Module. Provides serial Annunciator products including 24 Point I/O Module, and output information that can send location details to a LCD Annunciator. Includes extensive troubleshooting remote receiving station. diagnostics. DACT, Event Reporting Module. For applications Access Port. RS -232 service port for connecting PC where simple event status information is required (Alarm, tools for service diagnostics and for programming the Trouble, Supervisory, and AC power failure). CPU Flash EPROM memory. Dual RS - 232 Module. Available for interfacing to IDNet Addressable Communications Channel. printers or a maintenance terminal. Addressable channel provides communications for up to Single RS - 232 Module with Service Modem 250 remote addressable devices, including TrueAlarm Connection. Provides one port similar to the dual analog sensors and isolator bases (see descriptions on module, and a second port dedicated for dial -in from a page 3). service terminal, typically located off -site. With an off - Four NACs. Class B output is standard, rated for 2 A @ site terminal, programming changes and system 24 VDC nominal, with solid state current protection. diagnostics can be performed remotely, reducing service Class A operation is optional with the addition of an time for repair or reprogram. Security is maintained by adapter module. password protection. NAC operation can be selected for "on until Silence" or Optional Chassis Mount Modules "on- until- Reset ", and can be either coded or non - coded. Each NAC is also individually selectable to control Standard 4 A Expansion Module. Provides two taps Simplex synchronized visible notification appliances and of 2 A each, 28 VDC, filtered, non - regulated, similar to to control Simplex QuickAlertTM audible notification the standard power supply capacity. appliances using SmartSyncTM control, allowing separate Suppression Release Power Supply. This module audible and visible appliance operation using a common provides two taps of 2 A each, regulated at 24 VDC 2 -wire circuit. (Contact Simplex for more information.) t 10 %. Also included is a suppression release applique. Two Auxiliary Output Circuits. Operation is (This module may also be used for other applications programmable for trouble, alarm, supervision, or other requiring regulated voltage.) fire response functions. Output is one form "C" dry Battery Meter Module. Provides ammeter and contact each, rated 2 A @ 24 VDC. An optional relay kit is available for switching up to 1/2 A at 120 VAC. voltmeter for power supply monitoring. Power Supply. Standard output is 4 A @ 28 VDC, Dual Circuit Class A NAC Adapter Module. Mounts filtered, non - regulated. Internal system power is provided on the main 4010 printed circuit assembly and provides separately, allowing the 4 A to be available for NAC and the additional circuitry needed for Class A operation. auxiliary power tap functions. Over - current protection is Dual Circuit City Connect Module. Provides the solid state and self - resetting. interface required for direct wired reporting to Auxiliary Power Tap. Provides up to 1/2 A of the conventional City connection circuits. standard power supply voltage, over - current protected. Expansion Power Distribution Module. This Battery Charger. Capable of charging up to 25 Ah module provides two additional termination points for the sealed lead -acid batteries (4010 cabinet mounted). A 1/2 A auxiliary power output, or for one tap of the recharge time of 24 hours is typical with stable 120 VAC expansion power supply. input. For applications requiring larger batteries, external charger /cabinet assemblies are available. External N2 Communications Modules A depleted battery cutout feature is front panel selectable Up to six modules may be connected to the Simplex N2 to advise and/or to reduce current when battery voltage is serial communications bus. low. 4606 - 9101 LCD Annunciators provide remote acknowledge, reset. and alphanumeric status display. Optional Expansion Slot Modules (Refer to data sheet S4606- 0001.) (The 4010 is available with a Simplex 4120 Network 4605 Series 24 Point I/O Modules are available for Interface. 4010 points can be declared "public ".) remote mounting and provide 24 points that can be 4120 Network Interface, Fixed Media. Available for programmed as either general purpose switch inputs or wired applications. system controlled outputs. Typical applications are for remote annunciators and monitoring and control of other 4120 Network Interface, Modular Media. Available related processes. (Refer to data sheet S4010- 0002.) for wired connections or fiber optic. Require separate Simplex Time Recorder Co. 5 S4010- 0001 -2 399 4010 O • eratin • S • ecifications Input Power Requirements AC Input, 120 VAC base models 102 to 132 VAC, 60 Hz, 2 A maximum AC Input, 240 VAC base models 204 to 264 VAC, 50/60 Hz, 1 A maximum AC Input with 120 VAC expansion power supply 102 to 132 VAC, 60 Hz, 4 A maximum AC Input with 240 VAC expansion power supply 204 to 264 VAC, 50/60 Hz, 2 A maximum Environmental Operating Temperature Range 32 °F to 120 °F (0° C to 49° C) Operating Humidity Range up to 93% RH, non - condensing @ 100.4° F (38° C) maximum Output Ratings • Standard Power Supply Output 4 A total @ nominal 28 VDC, 24 VDC during battery operation Auxiliary Power Tap 1/2 A maximum of standard power supply voltage Expansion Power Supply Output * Additional 4 A @ nominal 28 VDC, 24 VDC during battery operation Suppression Release Power Supply Output' Additional 4 A @ 24 VDC ±10 %, 24 VDC during battery operation * Each power supply provides two output taps of 2 A each. Module Currents Module Supervisory Current Alarm Current DACT (Common Event or Point Reporting) 40 mA Dual RS -232 75 mA RS -232 with Service Modem 100 mA Network Modular with media cards 150 mA Refer to Alarm Current Network, wired communications 150 mA information listed below Dual Circuit City Connect 12 mA Dual Class A NAC Adapter 0 mA Remote 4606 -9101 LCD Annunciator 65 mA System Current (supplied separate from power supply output) Base System with: Supervisory Current ** Alarm Current ** no IDNet devices 195 mA 295 mA 50 IDNet devices 230 mA 330 mA 100 IDNet devices 265 mA 365 mA 150 IDNet devices 300 mA • 400 mA 200 IDNet devices 335 mA 435 mA 250 IDNet devices 370 mA 470 mA " Current calculation information: 1. To determine total supervisory current, add currents of modules in panel to base system value. 2. To determine total alarm current, add currents of modules in panel to base system alarm current and add all panel NAC loads and all auxiliary loads. Simplex Time Recorder Co. 6 S4010- 0001 -2 3/99 4010 Fire Alarm Control Selection Chart and Module Location Rules (refer to diagrams on next page) Category Model* Description Voltage Color 4010 -9101 Beige 4010 Fire Alarm Control Panel with: door, 120 VAC Control Panel 4010 -9102 cabinet, power supply /battery charger, IDNet Red Assembly 4010 -9201 interface, 4 NACs, 2 auxiliary relays, and external Beige (select one) 4010 -9202 N2 communications interface 240 VAC Red 4010 -9150 4010 Fire Alarm Control Panel electronics only 120 VAC N.A. for pre- shipped cabinets, requires door Optional Expansion Slot Features (two slots are available, select modules as required) Category Model Description 4010 -9810 DACT Module (Common Event Reporting) Reporting k an 4010 -9816 DACT Module (Point Reporting) I Includes two, 7 ft long RJ45 cables Modules 4010 -9821 4120 Network Interface Module with fixed, wired connections (select one) 4010 -9817 4120 Network Interface Module, Modular, requires 2 media modules RS - 232 4010 -9811 Dual RS -232 Interface Module Communications (select one) 4010 -9812 Single RS -232 Interface Module with Service Modem connection Media Modules 4010 -9818 4120 Network Wired Media Module Media modules mount on the 4010 -9817 (select 2 if using module without impact to slot allocation 4010 -9817) 4010 -9819 4120 Network Fiber Optic Media Module space. Chassis Mounted Expansion Modules (select as required) Category Model Description iimepp 4010 -9813 120 VAC input 4 A Expansion Power Supply Additional 4010 -9823 240 VAC input Power Supply (select one) 4010 -9814 Suppression Release Power Supply, 4 A @ 24 VDC, 120 VAC input 4010 -9824 regulated ± 10 %, includes front panel suppression system applique 240 VAC input Optional 4010 -9820 Battery Meter Module, Ammeter and Voltmeter Features (select one) 4010 -9825 24 VDC Expansion Power Distribution Module, provides two additional termination points for an expansion power supply tap or the auxiliary power output Optional 4010 -9806 Dual Circuit Class A (Style Z) NAC Adapter Module, 2 maximum Features 4010 - 9809 Dual Circuit City Connect Module, 1 maximum Accessories (select as required) Category Model Description 4010 -9826 120 VAC Auxiliary Relay Kit , allows one auxiliary relay to control up to 1/2 A @120 VAC, Optional select as required, 2 maximum Features 2975 -9801 Semi -flush trim, beige, 1 7/16" (37 mm) wide 2975 -9802 Semi -flush trim, red, 1 7/16" (37 mm) wide 2081 -9272 6.2 Ah Battery, 12 VDC, 2 required Batteries 2081 -9274 10 Ah Battery, 12 VDC, 2 required (required if batteries are 2081 -9288 12.7 Ah Battery, 12 VDC, 2 required internal, select 2081 -9275 18 Ah Battery, 12 VDC, 2 required, N ote: use will not allow bottom entry conduit one size) ry, q ry 2081 -9287 25 Ah Battery, 12 VDC, 2 required Cabinets 2975 -9215 Red Cabinet Dimensions: 22" H x 18" W x 5 3/8" D (select one if pre shipped) 2975 -9214 Beige Cabinet (559 mm x 457 mm x 137 mm) Doors 4010 -9858 Red Door (select one if Dimensions: 22" H x 18" W x 7/8" D pre shipped) 4010 -9857 Beige Door (559 mm x 457 mm x 22 mm) • ULC listed models are designated by a "C" or "CF" suffix such as 4010 -9010C or 4010 -9101 CF. "CF" indicates French labels. Contact your local Simplex representative for details. Simplex Time Recorder Co. 7 S4010- 0001 -2 3/99 . 4010 Module La out Reference Exr N3 € ow, 00 0 8 MIMI - e ' 4010-9820 0 0 i0 O r&' 'H : Meter Module 4010 -9806 i 4010 -9806 $ i or Expansion Class A ' Class A 4010 9809 4010 -9825 • Slots 1 8 2 Module Module City Module i 24 VDC Power Distribution i Block O i O 0 .® o • a a o or—? O O O 0 O 4098 -9814 rn 5 ®eO5Oe© x4010823, or 4010 -9824 • © Expansion Power Supply 8 - _ l ra l Ma 0 . AUX AUX, AUX.? BATTERY Mountin • Information POWER \ I I I Typical conduit entry area (cut holes as required) 6 1/4" o — (159 mm) -11. 18" (457 mm) 3/4" — 5 1/2" (19 mm) (140 mm) • E o 0 I Knockout .1•111• Mil •i •i' " " ' " " L ' Wall thickness guides - screw /nail holes _ ®!—' `:.&:•, .i : rc ®yf" $, for 1/2" (13 mm) (for semi -flush I I wall board mount) o ' • t Internal straps are • • i 1 e Wall thickness guides provided for wiring 4 $ o ° ® • for 5/8" (16 mm) management 21" 000000,__, 4 ( oe @oeo ®o® "t wall board) (2 each side) (533 mm) - _ -- r ......:,–.1....,...., - - • 1 Door, 5/8" -� - .i:.. -,ri.< xs ,.:,. A. - - (16mm)t - ------ -------- - -- - -- --- - - =" hick --- 04. 14 1/2" (368 mm) --o• Door and exposed L Battery Area cabinet dimension No conduit entry or wiring in this area ` for semi -flush mount a, ; 1 3/8" (35 mm) a: c Q b V _ 1 Wall board position reference for Shaded area is for non -power limited wiring semi -flush mount Simpler. the Simplex logo, TrueAlarm, WALK TEST. IDNet, QuickAlert, and SmartS,•nc are either trademarks or registered trademarks of Simplex Time Recorder Co. in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association /NFP.4). S4010- 0001 -2 3/99 ®Simplex Gardner, Massachusetts 01441 -0001 USA visit us on the world wide web at www.simp/exnet.com All specifications and other information shown were current as of printing and are subject to change without notice. Multi- Application Peripherals SiMpleX and Accessories Batteries and Chargers UL Listed 2081 Series System Batteries, 6.2 Ah to 50 Ah FEATURES / • Rechargeable, sealed lead -acid design: — Lead - calcium grid structure — Immobilized electrolyte in absorbent separator — High reliability dual seal construction — Low maintenance, no need to add water — Low self- discharge characteristics • One - piece, high impact polystyrene cell cover 0 • UL 924 recognized pressure relief valves • Available in a variety of capacities = 4 DESCRIPTION Simplex rechargeable sealed -lead acid batteries Sealed Lead -Acid Batteries for Panel Mounting provide reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems applications. They are designed with immobilized electrolyte in an absorbent separator, allowing them to APPLICATIONS provide rated capacity on the first cycle. Charging. These batteries are intended to be used Because of their sealed construction, packaging is with compatible Simplex battery chargers. allowed within the system electronics enclosure (see Series Connections. These batteries are required to Figure 1, page 2). When this is applicable, the quantity be connected in series to produce 24 V system voltage. of system cabinets and the battery wiring distances are Battery sets must be of identical voltage, model both minimized. number, appearance, and approximately the same date of manufacture for proper operation. Testing. Battery capacity testing is recommended to be performed by using a sealed lead -acid battery tester SPECIFICATIONS designed to withdraw a minimum of battery charge. The Nominal Voltage Rating 12 V /battery preferred tester applies a variety of amplitude and (6 V /battery for 2081 -9211, 50 Ah) duration controlled test pulses that compares terminal Discharge Rating 20 Hour Rate voltage against those predicted for the specific battery Typical Charge /Discharge Cycles 100 to 150 size. (Testing is available through Simplex Service). Preferred Charge Temperature Range .... 60° F to 90° F Disposal. Battery chemicals and materials can be (15.6° C to 32.2° C) recycled. Refer to information shipped with the battery or on its case. Return to the vendor or to a similarly qualified battery processing facility for proper disposal. @ 1998 Simplex Time Recorder Co. All rights reserved. S2081 0006 - 11/98 SEALED LEAD ACID BATTERY CONSTRUCTION DETAILS: (actual appearance will vary with battery size) Sealed outer cover Quick connect or post type terminal Vent hole (type varies with Potting material, black for battery size) negative, red for 0 0 positive (polarity is also clearly marked with + and -) ® F L —J Pressure relief valve Inner cover i , Absorbent separator used to immobilize electrolyte Semi - permeable Lead - calcium grids membrane separator Cell group Cell case (high impact polystyrene) S2081 -0006 -12 11/98 page 2 • BATTERY SPECIFICATIONS AND SELECTION CHART Battery Mechanical Specifications* Battery Ah, 20 Hour Length Width Height with Weight Model Rate (Ah) Terminals 2081 - 9272 6.2 6 1/8" (156 mm) 2 1/2" (64 mm) 4 3/16" (106 mm) 5.4 Ibs (2.5 kg) 2081 - 9274 10 6" (153 mm) 4" (102 mm) 4" (102 mm) 7.7 Ibs (3.5 kg) 2081 - 9288 12.7 6" (153 mm) 4" (102 mm) 4" (102 mm) 9.7 Ibs (4.4 kg) Ih 2081 - 9275 18 7 1/4" (184 mm) 3 3/4" (95 mm) 6 3/4" (171 mm) 13.6 Ibs (6.2 kg) 2081 - 9287 25 6 1/2" (165 mm) 4 15/16" (125 mm) 6 3/4" (171 mm) 17.3 Ibs (7.9 kg) 2081 - 9271 33 12 1/2" (318 mm) 3 3/8" (86 mm) 6 3/4" (171 mm) 24.5 Ibs (11.1 kg) (rectangular) 2081 - 9276 33 6 3/4" (171 mm) 6 1/2" (165 mm) 6 3/4" (171 mm) 24.5 Ibs (11.1 kg) (square) 2081 - 9211** 50 7 7/16" (189 mm) 4 1/2" (114 mm) 8 3/8" (213 mm) 21.5 Ibs (9.8 kg) Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the chart below for panel mounting compatibility. Except as noted, these batteries are 12 V each and series connected for 24 V system use. When installed in a fire alarm control panel, they are to be of identical voltage, appearance, model number, and approximately the same date of manufacture. " The 2081 -9211 battery supplies 6 V, four batteries are required per 24 V system. Battery Selection Chart for Fire Alarm Control Panel Mounting Battery Ah, Y0 Simplex Control Panel Series (see legend and notes below) Model Hour 4020 4100/4120 Rate 4003 4004 4005 4009 4010 (2, 4 or 6 -Unit) (2, 4 or 6 -Unit) 2081 -9272 6.2 2081 -9274 10 Yes Yes 2081 -9288 12.7 Yes 2081 -9275 18 Yes Yes Ext note 2 2081 -9287 25 Y Ext ? rectangu (rectangular) 33 Ext note 3 Ext 2081 - 9276 33 Yes (square) - Ext 2081 - 9211 50 Ext (note 1) Yes = can be placed in the respective equipment cabinet Ext = extemal battery cabinet required, refer to chart on page 4 Shaded area = not applicable NOTES: 1. Refer to chart on page 4 for external battery cabinet selection. The 50 Ah batteries may also be mounted in a 4 -unit or 6•unit 4100/4120 Universal Transponder with a solid door equipped with the battery shelf option. 2. The 4010 cabinet will accommodate 2081 -9275, 18 Ah batteries, but will not allow bottom entry conduit. 3. The 4020 cabinet will accommodate 2081 -9271, 33 Ah batteries, but will not allow bottom entry conduit. 4. Refer to individual fire alarm control panel product data sheets for additional battery application information. 5. These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers listed above. Refer to Simplex drawing 900 -012 for battery capacity selection charts. S2081- 0006 -12 11/98 page 3 EXTERNAL BATTERY CHARGER AND CABINET INFORMATION External Battery Cabinet Selection Chart Ah, 20 Externally Mounted Battery Battery Cabinets without Chargers Battery Hour Cabinets with Chargers (connects to charger in panel) Model * Ra te * 2081-9301" 1 2081-9303"* 2081 -9270"* 2081 -9281 2081 -9282 4009 -9801 4009 -9802 2081 -9275 18 Yes 2081 -9287 25 2081 -9271 Yes 33 Yes Yes (rectangular) 2081 -9276 33 (square) 2081 -9211 50 Batteries smaller than those listed are normally mounted in the product cabinet. " Refer to Simplex data sheet S2081 -0002 for additional information on these remote battery cabinet/charger products. Yes = can be placed in the respective equipment cabinet Shaded area = not applicable External Battery Cabinet Specifications Model Description Color Dimensions 2081 - 9281 2 -unit 4100 style cabinet without charger, with Beige 25 3/4" W x 20 3/4" H x 6 3/4" D solid door and battery shelf, primarily intended (654 mm x 527 mm x 171 mm) 2081 - 9282 for 50 Ah batteries Red 2081 - 9270** External battery cabinet without charger 2081 - 9301** Extemal battery cabinet with charger 26 1/2" W x 12" H x 12" D Red (673 mm x 305 mm x 305 mm) 2081 - 9303** Extemal battery cabinet with charger and with meters for voltage and current for up to 16 1 /4" W x 13 1 /2" H x 4 1 /8" D 4009 -9801 Extemal battery cabinet without 18 Ah charger, with solid door and batteries (343 mm x 413 mm x 105 mm) battery harness, for close- Beige nippled mounting to fire alarm for up to 25 3/4" W x 20 3/4" H x 4 1/8" D 4009 - 9802 control panel cabinet 33 Ah (654 mm x 527 mm x 105 mm) batteries ** Refer to Simplex data sheet S2081 -0002 for additional information on these remote battery cabinet/charger products. Simplex and the Simplex logo are registered trademarks of the Simplex Time Recorder Co. S2081 0006 - 11/98 f3 Simplex Gardner, Massachusetts 01441 -0001 U. S. A. ® Offices and Representatives Throughout the World Visit us on the world wide web at www.simplexnetcom. All specifications and other information shown were current as of printing and are subject to change without notice. g 6 SII ' 11pIP.X Multi- Application Peripherals and Accessories UL, ULC Listed, FM Approved 4606 -9101 LCD Annunciator NYC, MEA Approved* for the 4010 Fire Alarm Control Panel Features Remote LCD annunciator for use with the - `: Simplex 4010 fire alarm control panel LCD readout provides: • Two lines of 40 characters each • Wide viewing angle, super -twist design 4606 - 9101 LCD Annunciator • LED backlighting Control switches and status LEDs for: Descri•tion • Alarm, supervisory, or trouble acknowledge The Simplex 4606 -9101 LCD annunciator provides • Alarm silence remote annunciation using an 80 chars cter, back -lit, • System reset alphanumeric, LCD readout. Information is presented in clear, descriptive English language and includes: point status (alarm, trouble, etc.), alarm type (smoke detector, Three programmable LED indicators: manual station, etc.), number of system alarms, • Two LEDs are selectable as red or yellow supervisory conditions, and troubles, and up to 40 One LED is selectable as green or yellow character custom location label. Commun ications require • a single twisted, shielded pair and can also support the • With provisions for custom labeling 4605 series 24 I/O module on the same wire pair (up to six devices total). Information is transmitted over one twisted, Alarm, Supervisory, and Trouble conditions are also shielded pair (Simplex N2 communications) indicated by dedicated LEDs and a tone -alert audible indication. Each condition has a dedicated acknowledge Tone -alert sounder provides local audible push -button switch that silences the tone -alert but leaves indication the LED on until all conditions in that category are restored to normal. Lamp and LCD are functionally tested each time Repeated operation of the appr opriate acknowledge keyswitch is switched on switch will scroll the LCD display showing activity in the sequence of occurrence. The internal tone -alert also Mounts flush on standard 6-gang electrical box sounds to indicate the operation of any of the push - button switches. Mounting and trim options: • Surface mount box model 2975 -9217 (ordered separately) O • eration • Brushed aluminum trim model 4603 - 9111 All switches on the annunciator are controlled by the (ordered separately) "ENABLE" key switch with a key that is removable only in the disabled position. When enabled, notification appliances can be deactivated by pressing the "ALARM SILENCE" switch. Pressing the - CitydNewYarkD etrrleaoteWdags A3S93E "SYSTEM RESET" switch restores the system to normal Accepted fa operation. When system activity is normal, the LCD displays the time, date, and "SYSTEM IS NORMAL." m 1999 Simplex Time Recorder Co. All rights reserved. S4606- 0001 -2 3/99 4606 -9101 O. erator Information 2 X40 LCD READOUT, LED baddighted during normal conditions and abnormal operating conditions. FIVE STATUS INDICATOR LEDs provide system status indications in addition to LCD intonation. LEDs flash to indicate the condition and then when THREE PROGRAMMABLE LEDs acknowledged, remain on steady until reset each with custom labeling pocket. Si WI. ^t c « .g 'r, -Z r ' I . C in P .' „ $ 1„ t z / FlRE SYSTEr.1 SYSTEM ALARM ' POY.'ER :CONTROL ALARM SUPERVISORY ' TROUBLE SILENCED ON '.ENFCLL �'.' - S SUK - TR S LE ALARM C SYSTEM , AK ACK .,CY. ILE n'CE P.ESET ,, ALARM ACK acknowledges a Fire Alarm condition and silences the panel and all CONTROL ENABLE KEY SWITCH annunciator tone alerts. controls all switch functions. Key is removable only in disabled position. L SUPV ACK admowledges system conditions and silences the panel SYSTEM RESET restores control panel to normal and all annunciator tone - alerts. when all alarmed 'inputs are returned to normal. ALARM SILENCE causes audible notification appliances to be silenced, used TROUBLE ACK acmowledges system troubles and silences the after evacuation is complete and while alarm source is being investigated. panel and all annunciator tone - alerts. Simplex Time Recorder Co. 2 S4606-0001 -2 3/99 General Operating Specifications . , Voltage 18.9 to 32 VDC, system supplied Normal Operating Current 110 mA (LED backlighting is on) Battery Standby Current 65 mA (during battery backup, LED backlighting is tumed off after 30 seconds without switch activity) Alarm Current 140 mA maximum (LED backlighting is on and tone -alert is sounding) Operating Temperature Range 32° F to 120 °F (0° C to 49 °C) Operating Humidity Range up to 93% RH, non - condensing at 100° F (38° C) Communications �.... Type N2 external annunciator communications line from 4010 Fire Alarm Control Panel Capacity Up to 6 annunciator modules total, 4606 -9101 or 4605 series, 24 point I/O modules Wiring Requirements • 1, #18 AWG twisted, shielded pair for communications • 2, # 18 to #12 AWG for 24 VDC system power (plus ground) Mounting' Information` . • Trim Dimensions 4 1/2" H x 11 13/16" W (114 mm x 300 mm) Assembly Depth 1 5/16" (33 mm), 1 1/2" at terminal block location (38 mm) Standard Trim Finish Steel, painted beige 4603 -9111, Optional Trim Brushed aluminum (ordered separately) Trim Hardware Supplied with both slotted and tamper resistant screws • Masonry boxes: 6 -gang box, 2 1/2" (64 mm) deep minimum; RACO # 960, 2 1/2" deep; or RACO # 965, 3 1/2" (89 mm) deep (or equal) Boxes for Flush Mounting • Single gang boxes: use six, single gang boxes, 3 1/2" (89 mm) deep minimum, (supplied by others) RACO # 600 (or equal) • Conduit entrance is box dependent, refer to additional mounting information on page 4 and Installation Instructions 574 -188 2975 -9297, Surface Mount Box ,Option* (ordered separately) Dimensions f 12" W x 4 5/8" H x 1 3/4" D (305 mm x 117 mm x 44 mm) Finish Painted steel, ivory finish * Reference Wiremold box number V5748 -6. Simplex Time Recorder Co. 3 S4606- 0001 -2 3/99 • Flush Mount Ganged Boxes: Use 6 -gang box, 3 1/2" (89 mm) min. depth, RACO # 590 using knockouts 2 1/2" from front, or RACO # 600 using side knockouts or rear cable • _ _ clamps, or equal (supplied by others) ttn>•1 ti 'Al Alsen>•t iitn>ol Amnia! -.1 -� -� ® . W. Flush Mount Masonry Box: Use 6-gang box: # 960, 2 1/2" deep (64 mm) using top or bottom knockouts, or ^, n� : . ` -0 c ' x: RACO RACO # 965.3 1/2" (89 mm) deep, using e .o . 0" knockouts 2 1/2" from front, or equal ( - w ( ( ( (supplied by others) `! '� 1 L!' ..) . ) RI (Th Surface Mount Box: o. 0 0 0 ( (Th 0 0 Simplex model 2975 -9217 t — (\ (ordered separately) l o O O • Trim Plate O :. . .1.1 00 Imo O O o O 0 Terminal block access at •°`�' rear of enclosure, this side Annunciator Assembly NOTE: Enclosure extension into box is 10" W x 2 5/8" H x 1 5/16" D, 1 1/2" deep at terminal block access, offset to left (254 mm x 67 mm x 33 mm, 38 mm), select conduit entry accordingly Interconnection Wiring: Communications require a single # 18 AWG twisted, shielded pair. n IMMIiti IMMIM iiIIiIIIMII i Power requires 2, # 18 to # 12 AWG for 24 VDC system power (plus ground). Refer to installation instructions 574 -188 for additional wiring specifications. ec: t` rr 2 t . ts� , - + U �7-. 3 z, z x �� � 4 4606 -9101 LCD Annunciators 4010 Fire Alarm Control Panel Simpler and the Simples logo are registered trademarks of Simplex Time Recorder Co. in the U.S. and other countries. Wiremold it a trademark of The Wiremold Company. - 540 1441 - USA aSimplex Gardner, Massachusetts 01441 -0001 USA visit us on the world wide web at www.slmplexneLcom M specifications and other information shown were current as of printing and are subject to change without notice. Simplex TrueAlarm Analog Sensing p UL, ULC Listed *, FM Approved 4098 - 9710 Quick Connect NYC, MEA Approved** TrueAlarm Analog Photoelectric Sensor TrueAlarm addressable analog sensing with digital transmission via Simplex IDNet'", two -wire communications? __....r._._ _.. ._ ......... 11� ._s 1 f `ter.:.. AEI 1:7;-'7 QuickConnect design integrates sensor and base ., j d � ►� _ r 4 ,11111 11. f,- into one assembly: • Pluggable terminal block allows quick disconnect and reconnect 4098 -9710 QuidcConnect TrueAlarm Sensor • Mounts on 4" square or octagonal electrical boxes, escrtptton or single gang boxes (supplied separately) • Compatible with optional Adapter Plate 4098 -9832 Among its many features, the Simplex model 4010 Addressable Fire Alarm Control Panel fully supports Compatible with Simplex model 4010 Addressable TrueAlarm analog sensors and IDNet addressable Fire Alarm Control Panel to provide: devices. However, for applications that do not require the • Smoke sensitivity accurately maintained at a full TrueAlarm feature setts, the 4010 also supports the selected sensitivity of 2.5, 3.0, or 3.7 %/ft 4098 -9710 QuickConnect sensor to provide addressable obscuration analog sensing in a compact and cost - effective one -piece housing. The 4010 panel monitors and maintains the • Sensitivity monitoring satisfies NFPA 72 selected sensitivity of the 4098 -9710 as well as providing sensitivity testing requirements automatic compensation for environmental conditions • Automatic environmental compensation such as dust, dirt, and component degradation, and full • Automatic, once per minute individual sensor TrueAlarm data capture for each sensor. calibration check verifies sensor integrity QuickConnect Mounting. Wiring connections are • Ability to display and print detailed sensor made to a polarized, pluggable terminal block, providing a secure and quick connection to the sensor. A metal information in plain English language mounting bracket attaches to the sensor electrical box, • Tracking of excessive dirt accumulation allowing the 4098 -9710 sensor to be twisted and securely Highly functional and architecturally styled snapped in place. chamber enclosure: Sensor Alarm and Trouble LED Indication. The • Louvered design enhances smoke capture by 4010 control panel also determines when individual sensors need cleaning. Dirty sensors, or other sensor directing flow to chamber trouble, will automatically be annunciated at the control • Entrance areas are minimally visible when ceiling panel and that sensor's LED will light steadily. In an mounted alarm condition, the alarmed sensor's LED will light • Chamber is easily accessible for cleaning steadily. (LED operation is controlled by the panel. During system alarm, a sensor LED that was lit to Integral red LED for power - (pulsing), or alarm indicate trouble may return to pulsing to conserve or trouble (steady on) communications power, as long as it is not in alarm.) Magnetic test feature ensor ocations UL listed to standard 268 Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire • ULC fiistedmodel is4098 9710C. Alarm Code. On smooth ceilings, spacing of 30 ft (9.1 m) •• Accepted for use — City of New York Department of Buildings — MEA35 - 93E. may be used as a guide. t TrueAtsrm analog sensors and 1DNet communications are protected by one or For detailed installation information, refer to 4098 more of the following U.S. Patents: 5,155,468; 5,173,683; 5,543,777; 5,400,014; 5,552,765; 5,552,763; 4,796,025; DES. 377,460. Detectors, Sensors, and Bases Application Manual, 11 Contact Simplex for information on additional TnreAlannproducts. Simplex part number 574 - 709. O 1999 Simplex Time Recorder Co. All rights reserved. S4098 - 3/99 Specifications Power and Communications Provided by IDNet Communications, 24-40 VDC w /data, 1 address per sensor, up to 250 sensors /devices per 4010 Fire Alarm Control Panel IDNet Connections Screw terminals for in /out wiring, #18 to #14 AWG Sensitivity Panel selectable as 2.5, 3.0, or 3.7 %/ft obscuration Air Velocity Range 0 -2,000 ft/min (0 -610 m /min) Altitude up to 8,000 ft (2438 m) maximum UL Listed Temp. Range 32 F to 100 F (0 C to 38 C) Operating Temp. Range 32 F to 122 F (0 C to 50 C) Humidity Range 10% to 95% RH from 32 F to 122 F (0 C to 50 C) Color Frost White Dimensions Refer to mounting illustration 4098 - 9710 Mounting Information The 4098 -9710 QuickConnect sensor is supplied with a mounting bracket that attaches to the electrical box. Wiring is connected to a pluggable terminal block (supplied) that snaps securely into its mating pin connector in the sensor assembly. The sensor attaches to the mounting bracket with a twist -on snap action that secures it in place. P_ i ". , A , 7 r , Electrical Box Requirements: ; r w • . e. a ,';''','..,,-.g 4" octagonal or 4" square, 1 1/2" deep; $ ! . , A . ;i single gang, 2" deep (supplied separately) Field wiring --------6b. (2 tabs Mounting Bracket (2 places) (installed on box) Pluggable terminal block ----..., - Access to dipswitch a LED status indicator address on bade -( , . ) ( ( ) 1.- 2" � . a (51 mm) :gins ®°,11 ., . .g Wit: , ._z.a, s tcd/, : -;!`F 5" (127 mm) Mounting bracket for 4098 -9710 QuickConnect Sensor 4098 -9710 (included) 1/4" (6.4 mm) 4 14 63/8 "(162mm) opl 4098 -9832 Optional Adapter Plate (required for 4" square box mounting) Simplex, the Simples logo, TrueAlarm, and IDNet are trademarks or registered trademarks of Simplex Time Recorder Co. in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). 54098 -0022 -2 3/99 5 Simplex Gardner, Massachusetts 01441 -0001 USA ® visit us on the world wide web at www.simplexnetcom Ali specifications and other information shown were current as of printing and are subject to change without notice. ■ S�Mplex Multi- Application Peripherals UL, ULC Listed, FM Approved 1DNetTm Communicating Devices Addressable Manual Stations Features l ' Individually addressable manual fire alarm - ! • RM stations with: • Power and data supplied via Simplex IDNet 1 addressable communications using a single wire PULL DOWN pair* • Operation that complies with ADA requirements MIL • Pull lever that protrudes when alarmed • Break -rod supplied (use is optional) � Multiple models are available: 4099 -9001 IDNet Addressable Manual Station (front and side view) • Single action operation • Double action operation, Breakglass or Push PER ALA' M For use with Simplex model 4010 addressable BREAK LASS ( PUSH fire alarm control panels 'EMI DOWN ' PULL DOWN Compact, sealed construction: \ O\ • Allows mounting in standard electrical boxes • Screw terminals for wiring connections • Reduces dust infiltration 4099 - 9002 Breakglass 4099 - 9003 Push Tamper resistant reset key lock (keyed same as Simplex fire alarm cabinets) 0 • eration Activation of the Simplex 4099 -9001 single manual Multiple mounting options: station requires a firm downward pull to activate the • Surface or semi - flush with standard or matching alarm switch. Completing the action breaks an internal Simplex boxes plastic break -rod (visible below the pull lever, use is P optional.) The use of a break rod can be a deterrent to • Flush mount adapter available vandalism without interfering with the minimum pull • Adapters are available for retrofitting of existing requirements needed for easy activation. The pull lever latches into the alarm position and remains extended out addressable stations of the housing to provide a visible indication. Double Action Stations ( Breakglass) require the operator to strike the front mounted hammer to break the Descri •tion glass and expose the recessed pull lever. The pull lever then operates as a single action station. The Simplex model 4099 9001 addressable station Double Action Stations (Push Type) require that a combines the familiar Simplex manual station housing with a compact communication module that is easily spring loaded interference plate (marked PUSH) be installed to satisfy demanding applications. Its integral pushed back to access the pull lever of the single action individual addressable module (IAM) constantly monitors station. status and communicates changes to the connected control Station reset requires the use of a key to reset the panel via Simplex IDNet communications wiring. manual station lever and deactivate the alarm switch. (If the break -rod is used, it must be replaced.) Simplex IDNet addressable communications are protected by U.S. Patent Station testing is performed by physical activation of 4,796,025. the pull lever. Electrical testing can be also performed by unlocking the station housing to activate the alarm switch. © 1998 Simplex Time Recorder Co. All rights reserved. S4099- 0001 -2 10/98 IDNet Addressable' Manual Station' Product Selection : • Addressable Manual Stations Model Description 4099 -9001 Single action addressable manual station 4099 -9002 Double action addressable manual station, Breakglass operation 4099 -9003 Double action addressable manual station, Push operation Mounting Accessories Model . Description Reference 2975 -9178 Surface mount steel box, red 2975 -9022 Cast aluminum surface mount box, red Refer to page 3 for dimensions 2099 -9813 Semi -flush trim plate for double gang switch box, red Primarily for retrofit, refer to page 4 2099 -9814 Surface trim plate for Wiremold box 5744 -2, red 2099 -9819 Flush mount adapter kit, black 2099 -9820 Flush mount adapter kit, beige Refer to page 4 for details 2099 -9803 Replacement breakglass 2099 -9804 Replacement break -rod IS • ecifications Power and Communications IDNet, 1 address per station, up to 2500 ft (762 m) from fire alarm control panel, up to 10,000 ft ( 3048 m) total wiring distance (including T -Taps) Address means Dipswitch, 8 position Wire Connections Screw terminal for in /out wiring, for #18 to #14 AWG wire UL Listed Temperature Range 32 °F to 120° F (0° C to 49° C) intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° F) Housing Color Red with white raised lettering Material Housing and pull lever are Lexan polycarbonate Pull lever color White with red raised lettering Housing Dimensions 5" H x 3 3/4" W x 1" D (127 mm x 95 mm x 25 mm) IDNet Manual Station Semi = Flush . Mountin • 4" Square box mount 4" (102 mm) square box, 2 1/8" (54 mm) minimum Single gang box mount depth RACO #231 or equal (supplied by others) Single gang box, 2 1/2" deep (64 mm), RACO #500 or equal (supplied by others) ° Mount flush or with 1/16" (2 mm) maximum extension E ° ° DO NOT REC 4" Square box with cover plate 0 I Station FIRE C ALARM side view Sin gle gang cover plate, 3/4" (19 mm) extension, RACO #773 or equal (supplied by others) PULL DOWN Single gang ■1■ box outline Wall surface Simplexi Semi -flush mount side view Simplex Time Recorder Co. 2 S4099 0001 - 10/98 IDNet Manual Stations Surface Mountin. Simplex 2975 -9178 Box 5 3/16" H x 4" W x 2 3/16" D Wiremold box #5747 Simplex 2975 -9022 cast box (132 mm x 102 mm x 56 mm) Knockouts located 4 5/8" H x 2 7/8" W x 1 3/8" D 5" H x 3 7/8" W x 2 3/16" D (ordered separately) (117 mm x 73 mm x 35 mm) (127 mm x 98 mm x 56 mm) top and bottom su lied by others ( PP � Y ) (ordered separately) O • O FIRE CD ALARM AMIE ° �_> ° PULL 1 DOWN ♦ `- Knockouts for 3/4" 5" threaded conduit located (127 mm) top and bottom L fl Simplex (25.4 mm) I t— 3 3/4" (95 mm) — 4099 -9001 Housing dimensions Surface Mount Side View with Internal Detail Application Reference 1 1/4" Refer to NFPA 72, the National Fire (32 mm) Simplex 2975 - 9178 box Alarm Code, (reference section 5 -8) Field wiring (shown for reference) and all applicable Local codes for (shown for reference) complete requirements for manual ii i gn k rL'— ..,, r'r stations. The following summarizes the t'a basic requirements. 1. Stations shall be located in the Address setting under K normal ath of exit and distributed resealable label (accessible in the protected area such that they with cover open) - 2 5/8" are unobstructed and readily (67 mm) accessible. ' "+ 2. Mounting shall be with the Station cover operable part not less than 3 1 /2 ft hinges open for (1.1 m) and not more than 4 1/2 ft installation access � � g (1.37 m) above floor level. lax z Switch wiring 3. At least one station shall be s ',":",&' `" 1 (prewired) provided on each floor. Additioal �r ; „ .. .0 stations shall be provided to obtain r:S!K ' r_±.., e; 4 °f> a travel distance not more than 4Vr..; -,. - ..Jr 200 ft (61 m) to the nearest station Si Y:` ti 1`,41 i i:1 ,4: -' from any point in the building. ''4,;(;;,..A.-7{ i 4. When manual station coverage �" = appears limited in any way, additional stations should be installed. Simplex Time Recorder Co. 3 S4099- 0001 -2 10/98 • IDNet Manual Station, Retrofit Mountin • Information / / 0 0 Wiremold® When retrofit mounting the ®o c5 receptacle box 4099 9001 addressable station 2099 -9814 Surface trim model 5744 -2 for Wiremold box (supplied by for replacement of previous 5 1/81H x 5 "W others) generation Simplex addressable (130 mm x 127 mm) manuals stations, adapter plates c o may be required to fit the existing boxes. The diagram to o d o Two gang switch box, each 3" H x 2" W x 2 3/4" D the right illustrates common ! ® • °_ (76 mm x 51 mm x 70 mm) retrofit applications. (supplied by others) 4099- 9001IDNet I PULL DOWN ' ®O 0 addressable station 0 ar.X ' c..__ 2099 -9813 Semi -flush trim for 2 gang O ®O ° switch box, 6" H x 4 1/2" W • (152 mm x 114 mm) IDNet Manual Station, Flush Mounting Information Flush mount adapter kit SIDE VIEW 2099 -9819, black FRONT VIEW 2099 -9820, beige NOTE: Box must be recessed into wall 1" to 1 1/8" (25.4 mm to 29 mm) i • 8 ` [ . IRE ® ALARM O (203 mm) • 0 O 1. PULL DOWN (152 , I .r.�.� • 0 mm ) 1 O • 3 sonplex / 4 11/16" (119 mm) „ square box, 2 1/8" (54 mm) minimum depth Wall * surface •---- 4 3/4" (121 mm) -N. 6 3/4" (171 mm) Simplex, the Simplex logo, and IDNet are either trademarks or registered trademarks of Simplex Time Recorder Co. in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). Lexan is a registered trademark of the General Electric Co. aSimplex S 0 1441 -00 10/98 Gardner, Massachusetts 01441 -0001 USA visit us on the world wide web at www.simplexnetcom All specifications and other information shown were current as of printing and are subject to change without notice. B ■ - SII Multi Application Peripherals UL, ULC Listed, FM Approved IDNetTM Communicating Devices NYC, MEA Approved* 4090 -9001, Individual Addressable Module (IAM) Features IDNet addressable communications supply both PA = -. data and power over a single wire pair to 6 ' S oleX provide**: • • Supervised Class B monitoring of normally open, ; . dry contacts �. • Total wiring distance from IAM to supervision resistor(s) of up to 500 ft (152 m) _ _ ti • Monitored connection is compatible with Simplex _ _- l ii r ,> 2081 -9044 Overvoltage Protectors for outdoor or electrically noisy applications For use with Simplex model 4010 addressable 4090 - 9001 IDNet Supervised IAM (shown approximately full size) fire alarm control panels Compact, sealed construction: Current Limited •Operation Applications • NEMA 2 enclosure rating The 4090 -9001 can sense normal, open circuit, short • Allows mounting in single gang electrical box circuit, and current limited conditions. With the proper • Screw terminals for wiring connections end -of -line and current limiting resistors, dual functions • Reduces dust infiltration such as tamper switch and waterflow switch monitoring can be determined and communicated by a single Provides current limited monitoring: addressable point. • To monitor tamper switch (trouble) and waterflow Specificationst switch (alarm) on same circuit using one point Power and Communications IDNet, 1 address per IAM Multiple operation modes are available and are Screw terminals for in/out wiring, selectable at the control panel: Wire Connections for #18 to #14 AWG wire • Contact closure status can be tracked • 500 ft (152 m) w/o protectors • Momentary contact closure conditions can be Distance from IAM to • 400 ft (122 m with 2081 -9044 Contacts ( ) latched, such as from rate - of - rise heat detectors Overvoltage Protectors Descri • tion • Up to 2500 ft ( 762 m) from fire alarm control panel, The 4090 -9001 is an individual addressable module IDNet Wiring Distance • Up to 10,000 ft ( 3048 m) total (IAM) with both power and communications supplied by wiring distance (including T -Taps) a two -wire IDNet circuit. It provides location specific 1 9/16" x 1 3/4" x 1 1/4" addressability to a single initiating device (such as single Dimensions (40 mm x 44 mm x 32 mm) station smoke detector alarm contacts or heat detector Housing Material Black thermoplastic contacts) or multiple devices at the same location by 32 °F to 120° F (0° C to 49° C) monitoring normally open dry contacts and the wiring to Temperature Range intended for indoor operation an end -of -line resistor. Humidity Range Up to 93% RH at 100° F (38° C) Closure of the monitored contacts initiates an alarm or other response as programmed at the 4010 Fire Alarm Supervision Resistor" 6.81n, 1/2 W Control Panel. An open in the monitored circuit wiring Resistors for Current 1.8 kfl and 4.7kS2, 1/2 W will cause a trouble to be reported. Limited Operation" Selections can be made at the control panel to maintain Input Requirements normally open, dry contacts the alarm condition if the initiating device contacts are • Accepted for use— City of New York Department of Buildings— MEA35 -93E. momentary, such as from a rate - rise heat detector, or to " Simplex IDNet addressable communications are protected by U.S. Patent track the device contact status. 4,796,025. t Refer to installation instructions 574 -331 and field wiring diagram 842 -073 for additional information. © 1999 Simplex Time Recorder Co. All rights reserved. S4090- 0001 -2 2/99 Mounting Information 4090 -9001 IDNet = Field wiring shown supervised IAM -- - for reference /- ,,. Q P � I , I I I i '...cH4 'r ' _, j Single gang electrical \' box 2 1/2" (64mm) 1' ... -- J minimum depth 1; j (supplied by others) 1I Address setting under resealable label g Single gang blank cover plate and mounting screws (supplied by others) Simplex, the Simplex logo, and IDNet are either trademarks or registered trademarks of Simplex Time Recorder Co. in the C.S. and /or other countries. S4090- 0001 -2 2/99 ®Simplex Gardner, Massachusetts 01441 -0001 USA visit us on the world wide web at www.simplexnet.com All specifications and other information shown were current as of printing and are subject to change without notice. } g ® Sjmp'QJ( Multi- Application Peripherals UL, ULC Listed, FM Approved IDNetTM Communicating Devices: 4090 -9002 Relay IAM, NYC, MEA Approved* 4090 -9101 and 4090 -9106 Zone Adapter Modules Features IDNet addressable interface modules for use soak with Simplex model 4010 fire alarm control r. panels** it . ] j p , ,, . ®5 4090 -9002, Individual Addressable Relay Module i =:®! .. i ®s (Relay IAM): _. os , • A single addressable point provides control and '�, .V-� ®- status tracking of a form "C" contact , r wn, i • Low power latching relay design allows IDNet F L-L - - - - ' �� communications to supply both data and module O power Monitor ZAMs (Zone Adapter Modules) provide 4090 Series IDNet Relay IAM /ZAM Package an IDNet addressable interface to a conventional (shown approximately 1/2 size) initiating device circuit (IDC) available as: • 4090 -9101, Class B (Style B) monitoring for S • ecifications 2 -wire or 4 -wire initiating devices, with power reset connections for 4 - wire devices Communications IDNet, 1 address per device • 4090 - 9106, Class A (Style D) monitoring for Relay IAM Power Supplied by IDNet communications 2 - wire initiating devices Relay IAM Contacts (form "C ", SPDT) • Zone device power is supplied separately • 2 A @ 24 VDC, for transient (typically from fire alarm control panel) Power Limited Rating suppressed loads • (Refer to device compatibility list on page 2) • 1 A @ 24 VDC for inductive loads Compact, sealed construction: Non -Power Limited Rating lolad @ 120 VAC, transient suppressed • NEMA 2 enclosure rating for minimal dust ZAM Input Voltage 18.9 to 32 VDC (nominal 24 VDC) infiltration Supervisory =16 mA maximum • Mounts in standard 4" square electrical box ZAM Current @ 24 VDC Alarm = 72 mA maximum • Screw terminals for wiring connections (actual current is determined by total g device requirements) 4090-9101 ZAM, Zone 3.3 K2, 1 W Descri •tion Supervision Resistor IDNet Relay IAMs allow the Simplex 4010 fire alarm Wire Connections Screw terminals for in/out wiring, #18 to #14 AWG wire control panel to control a remotely located form "C" contact using IDNet addressable communications for both • Up to 2500 ft ( 762 m) from fire data and module power. Typical applications would be for alarm control panel switching local power for control functions such as IDNet Wiring • Up to 10,000 ft ( 3048 m) total wiring elevator capture, or control of HVAC components, distance (including T -Taps) pressurization fans, dampers, etc. Relay status is also • Compatible with Simplex 2081 -9044 communicated requiring only one device address. Overvoltage Protectors IDNet Monitor ZAMs allow a single addressable point Dimensions H x4 1/8 W x 1 51 (105 mmx105 mmx35 ) m) to monitor a conventional initiating device circuit (IDC) zone populated with 2 -wire or 4 -wire initiating devices. Housing Material Black thermoplastic Refer to page two for compatible devices. Mounting Plate Material Sheet metal, galvanized Temperature Range 32 °F to 120° F (0° C to 49° C) • Accepted for use — City of New York Department of Buildings — MEA35 -93E. intended for indoor operation • Simplex IDNet addressable communications are protected by U.S. Patent Humidity Range Up to 93% RH at 100° F (38° C) 4,796,025. © 1999 Simplex Time Recorder Co. All rights reserved. S4090 0002 - 3/99 Monitor ZAM Initiating Device Compatibility Reference 'Chart • Two -Wire Devices, for use with Class A Monitor ZAM 4090 -9106 or Class B Monitor ZAM 4090 -9101 Detectors (20 maximum) Compatible Bases 2098 -9201 through -9203, and -9276 2098 -9211 and -9637 2098 -9209 no base required 4098 -9401 through -9404 4098 -9407 through -9410 2098 -9211 4098 -9612 through -9615 4098 -9788, -9683, and -9684 4098 -9601, -9602, and -9605 4098 -9788, and -9683 Four - Wire Devices, for use with Class B Monitor ZAM 4090 - 9101 (refer to note 1) Detectors (20 maximum) Compatible Bases 2098 -9201 through 2098 -9203, and -9576 2098 -9536 4098 -9407 through -9410 4098 -9601, -9602, -9605, and -9612 through -9615 4098 -9682 NOTES: 1. Four -wire detectors require detector voltage to be connected to resettable power terminals. 2. Refer to installation instructions 574 -183, 574 -184, and field wiring diagram 842 -073 for additional information. 3. Contact Simplex for additional compatible devices. ZAM and Rela -IAM Mou'ntin. Information 00 fl i 1 r , ` Address setting under resealable label ® ' •-) 1j- 1, • ;` "'s kip VVVV t ,�•� JI 4" (102 mm) square box, 2 1/8" (54 mm) minimum '/ depth, RACO 231 or equal I (supplied by others) ® IDNet ZAM or Relay IAM 2 -gang cover plate (supplied by others) Simplex, the Simplex logo, and IDNet are either trademarks or registered trademarks of Simplex Time Recorder Co. in the U.S. and /or other countries. �'MP' iS4090-0002-2 3/99 Gardner, Massachusetts s 01441 -1441 -0001 01 USA USA visit us on the world wide web at www.simplexnet.com All specifications and other information shown were current as of printing and are subject to change without notice. Multi- Application Peripherals SiMpleX and Accessories Heat Detectors UL Listed 2098 Series Low Profile FM Approved* Fixed and Rate -of -Rise FEATURES • Available models: — Fixed temperature operation at 135° F (57 C) ' or 200° F (94° C) J°,Y — Available with both fixed temperature and Rate -of -Rise operation — Single or dual circuit contacts* — Refer to model selection chart on page 2 r o s, . • Dangling disk indicates operation of fixed 3 temperature element ',"i# k • Rate -of -Rise element is self- restoring • Low profile design with white color blends 2098 Series Low Profile Heat Detector with most ceilings • Easy installation: APPLICATIONS - Attaches with atwist- and -lock motion Fixed Temperature Operation. Detectors rated at 135° F (57° C) are suitable for most applications where — Same mounting plate accommodates 4 inch temperatures do not exceed 100° F (38° C). (102 mm) octagonal electrical box, or direct mounting Detectors rated at 200° F (94° C) are suitable where the ambient temperature exceeds 100° F (38° C) but not 150° F (66° C). DESCRIPTION Fixed temperature operation employs a fusible alloy Combination rate -of -rise and fixed temperature selected for the desired temperature. When activated, heat detectors should not be mounted in line with the extemal heat collector drops away for quick visual space heater blowers or directly over stoves and ovens indication. When the fixed temperature operation or other heat - generating units where rapid temperature occurs, the heat detector requires replacement to changes are normal. restore to normal. Intrinsically Safe. Single circuit heat detectors are Rate - - Rise Operation. Heat detectors using the appropriate for use with Simplex intrinsically safe rate -of -rise principle of operation have an air chamber, barrier modules as "simple apparatus". Refer to data a vent, and a flexible metal diaphragm. When the unit is sheets S2081 -0013 and S2081 -0018 for details. heated, the air in the chamber expands. The vent permits the chamber to breathe and slowly release the SPECIFICATIONS expanded air. If a fire occurs, the air in the chamber will expand more rapidly than it can be vented. This causes Contact Ratings • 1 A @ 6 -28 VDC, resistive the diaphragm to close its normally open contacts to • 3 A @ 6 -125 VAC, resistive signal an alarm condition. The rate -of rise heat detector restores itself to normally when the heat is dissipated. Rate -of -Rise Operation 15° F /min (8.33° C /min) Dimensions See diagrams on page 2 WARNING: In most fires, hazardous levels of smoke ann o�xic gas can build up before a heat detection device would initiate an alarm. In cases where Life FM approval applies to dual contact models, refer to chart on • Safety is a factor, the use of smoke detection is highly page 2. recommended. co 1999 Simplex Time Recorder Co. All rights reserved. S2098 - 3/99 PRODUCT SELECTION INFORMATION • Single Circuit Models, 1 Normally Open (N.O.) Contact, UL Listed _Model: • Marking Operation Fixed Temperature Rating UL Spacing 2098 -9439 none Fixed Temperature 135° F (57° C) 50 ft x 50 ft (15.2 m x 15.2 m) 2098 -9440 gray ring with Rate -of -Rise 200° F (94° C) 2098 -9441 gray dot 135° F (57° C) 25 ft x 25 ft (7.6 m x 7.6 m) gray ring Fixed Temperature 2098 -9442 and dot 200° F (94° C) 15 ft x 15 ft (4.5 m x 4.5 m) Dual Circuit Models, 2 Normally Open (N.O.) Contacts, UL Listed and FM Approved :Model: t " � : Markin�_� O` g pe rati on _Fixed Temperature Rating UL Spacing .FM Spacing 2098 -9443 none Fixed Temperature 135° F (57° C) 50 ft x 50 ft 30 ft x 30 ft 2098 -9444 gray ring with Rate -of -Rise 200° F (94° C) (15.2 m x 15.2 m) (9 m x 9 m) 2098 -9445 gray dot 135° F (57° C) 25 ft x 25 ft 20 ft x 20 ft Fixed Temperature (7.6 m x 7.6 m) (6.1 m x 6.1 m) 2098 -9446 ring 200° F (94° C) 15 ft x 15 ft 15 ft x 15 ft and gray dot (4.5 m x 4.5 m) (4.5 m x 4.5 m) DIMENSIONS Reversible mounting plate 1 3/8" 1 5/8" (35 I mm) (42 mm) t 4 9/16" (116 mm) Junction Box Mounting Ceiling Surface Mounting MOUNTING NOTES: 1. Reversible base accommodates electrical junction box mounting or direct surface mounting. 2. For electrical box mounting, use 4° (102 mm) octagonal box, or 4" square box with plaster ring. 3. Reference NFPA 72, the National Fire Alarm Code for more detailed information on location, spacing, maintenance and testing, etc., for these detectors. 4. In most fires, hazardous levels of smoke and toxic gases can build up before a heat detector would initiate an alarm. In cases where life safety is a factor, the use of smoke detectors is required. Simplex and the Simplex logo are registered trademarks of the Simplex Time Recorder Co. S2098 - 0051 - 3/99 f Simple Gardner, Massachusetts 01441 -0001 U. S. A. ® Offices and Representatives Throughout the World Visit us on the world wide web at www.simplexnetcom. All specifications and other information shown were current as of printing and are subject to change without notice. g 51111plP.X QuickAlertTM Notification Appliances UL Listed SmartSyncTM Compatible AudibleNisible Notification Appliances with Synchronized Flash Rates and Electronic Horns Features Wall mount audible /visible notification appliances _ j - __ a •um • with efficient electronic horn and high output - _ _ xenon strobe_ Compatible with ADA requirements • - - •- - Operates over a two -wire SmartSync circuit to provide: • Horns that are controlled separately from strobes FIRE FIR E on the same two -wire circuit • "On until - silenced" and "on operation QuickAlert A/V Notification Appliances are Available in on the same two - wire pair Red with White Lettering and White with Red Lettering • Horn control that can be selected to be temporal Features (Continued) coded, march time coded, or on continuously • Strobe appliances on the same circuit operating at Visible notification appliance (strobe): a synchronized 1 Hz flash rate • 24 VDC xenon strobe available with 15, 75, or 110 • Class B (Style Y) operation requires connection to candela output (strobe rating is clearly indicated on reflector) a compatible Simplex SmartSync NAC or to • UL listed to Standard 1971 SmartSync Control Module (SCM) 4905 -9938 • Class A (Style Z) operation is supported by using Audible notification appliance (horn): the 4905 -9938 SCM • Low current, 24 VDC electronic horn with Available housing colors: harmonically rich output sound suitable for either coded or steady operation • Red cover with white "FIRE" lettering • UL listed to Standard 464 • White cover with red "FIRE" lettering • Covers are available separately to convert housing Descri .tion color Audible and Visible Notification. For applications requiring audible /visible notification with horn tones, Simplex QuickAlert notification appliance design these Simplex 4903 series appliances combine a high provides: intensity strobe with a low current electronic horn in a • Flexible, easy, and convenient semi - flush or compact package that is easy and quick to install. The surface wall mounting to single gang, double gang, horn provides a loud and penetrating, harmonically rich or 4 - inch square outlet box sound suitable for either coded or steady operation as determined by the selected SmartSync mode. • Optional mounting adapters are available to cover SmartSync Two - Wire Advantage. With both audible surface mounted electrical boxes and to adapt to and visible controls carried on the same two -wire NAC Simplex 2975 - 9145 boxes circuit, using the SmartSync operation (patent pending) • In/out wiring terminals for #18 AWG to can provide the opportunity for significantly reduced (solid) #12 AWG, accessible from front of installation time and expense for both retrofit and new housing, providing easy access for installation, construction. inspection, and testing Multiple Model Choices. These AN notification • Rear of housing assembly does not extend into box appliances are available with three strobe intensity levels and with red or white housings. Mounting can be semi- • Rugged, high impact, flame retardant flush or surface mounted on a standard single gang, thermoplastic housing double gang, or 4" square (102 mm) electrical box. • UL listed red wire guard is available for Optional accessories are available to increase mounting semi -flush or surface mounting and application flexibility. © 1999 Simplex Time Recorder Co. All rights reserved. 54903- 0010 -1 10/99 Smart Sync Two- Wire Control Smart Sync output control is available from: Background. Typically, fire alarm control panels • 4009 IDNetTm NAC Extender, models 4009 -9201 and activate both audible and visible notification upon receipt 4009 -9301 (refer to data sheet S4009 -0002) of an alarm. At the direction of an authorized operator (or by pre - determined program), audible notification • 4010 Fire Alarm Control Panel with operating appliances may be silenced before the alarm condition is software Revision 2.X or higher (refer to data sheet reset (on- until - silenced) while the visible notification S4010 -0001) appliances are kept activated until the alarm condition is reset (on- until- reset). This operation has traditionally • SmartSync Control Module (SCM) 4905 -9938, required two different circuits (four -wire operation). The provides a SmartSync interface to conventional Simplex SmartSync operation mode provides this NACs and also is used with the 4009 IDNet NAC function using a single circuit (two -wire operation). extender or 4010 Control Panel to provide Class A operation (refer to page 6 for more information) - Product Selection AudibleNisible Notification Appliances (Horn /Strobe) Visible Notification Appliance Output s Model Number Housing Color 15 cd 75 ed 110 cd 4903 -9417 ✓ 414k 4903 -9418 ✓ Red with white "FIRE" lettering 4903 -9419 ✓ 4903 -9428 ✓ 4903 -9429 ✓ White with red "FIRE" lettering 4903 -9430 ✓ Adapters Model Description Dimensions 4905 -9937 Surface mount red adapter skirt Use to cover 1 1/2" 5 3/8" H x 5 1/4" W x 1 5/8" D deep surface (136 mm x 133 mm x 41 mm) 4905 -9940 Surface mount white adapter skirt mounted boxes Total depth with strobe = 4 3/8" (111 mm) 4905 -9931 Adapter plate, red, for mounting to Simplex 2975 -9145 box 8 5/16" x 5 3/4" x 0.060" Thick (typically for retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975 -9145 Red mounting box, requires Adapter Plate 4905 -9931 7 7/8" x 5 1/8" x 2 3/4" D (130 mm x 200 mm x 70 mm) Covers and Guard Model Description Dimensions 4905 -9957 Red cover with white "FIRE" lettering 5 1/8" H x 5" W x 1 1/2" D 4905 -9958 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) 4905 -9961 Wire guard with mounting plate, UL listed, red, compatible 6 1/16" H x 6 1/16" W x 3 1/8" D with semi -flush or surface mounted boxes (154 mm x 154 mm x 79 mm) Synchronization Modules Model Description Dimensions 4905 -9938 SmartSync Control Module, Class A or Class B (Style Z/Y), 4" x 4 1/8" x 1 1/4" D installs in 4" square box (refer to diagram on page 6) (102 mm x 105 mm x 32 mm) Simplex Time Recorder Co. 2 S4903- 0010 -1 10/99 Specifications Strobe Specifications Rated Voltage Range 22 to 29 VDC Operating Voltage Range 17.6 to 32 VDC See Note 1 below Flash Rate 1 Hz Strobe Output Nominal Average Current @ 24 VDC • Current Ratings, Strobe Flashing and 15 cd 67 mA Horn On (see Note 2) 75 cd 154 mA 110 cd 211 mA Strobe Rating 22 VDC 29 VDC Inrush /Peak Current Performance Reference, Nominal Average Currents.with Strobe Flashing 15 cd 77 mA 62 mA 134 mA and Horn On, and Inrush/Peak Currents 75 cd 168 mA 134 mA 262 mA (see Notes 2 and 3) 110 cd . 212 mA 187 mA 407 mA Horn Specifications Rated Voltage Range 22 to 29 VDC Operating Voltage Range 17.6 to 32 VDC Sound Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Hom.Sound Output Ratings @ 10 ft (3 m) Voltage 22 VDC 24 VDC 29 VDC Sound Type (see Note 4) Steady_ Coded - Steady . Coded Steady Coded Reverberant Chamber, UL 464 Test 84 dBA 79 dBA 85 dBA 80 dBA 86 dBA 81 dBA Anechoic Chamber 90 dBA 86 dBA 91 dBA 86 dBA 91 dBA 87 dBA 4905 -9938 SmartSync Control Module (SCM) Rated Input Voltage Range 22 to 29 VDC with maximum ripple of 2 V peak -to -peak Operating Input Voltage Range 17.6 to 32 VDC SmartSync NAC Output Capacity 2 A maximum (total device quantity is control panel dependent) Strobe Control NAC Input Current Output NAC current, plus 30 mA @ 24 VDC for SCM operating power Horn Control NAC Current 4 mA @ 24 VDC Class A Operation Mounting Mount SCM within 20 ft (6 m) of control panel, use metal conduit Requirement General Specifications Housing Dimensions (including Tens) 5 1/8" H x 5" W x 2 3/4" D (130 mm x 127 mm x 70 mm) Temperature Range 32 °F to 122° F (0° C to 50° C) Humidity Range 10% to 93 %, non - condensing at 100° F (38° C) Connections Terminal blocks for #18 AWG to #12 AWG NOTES: 1. These products operate to the nameplate rating requirements of UL Standard 1971 in effect at the time of the product listing. Requirements included demonstrating performance over the range of -20 % and +10% of the namplate rating as is stated as the operating voltage range. 2. Strobes supply rated light output at rated flash rate over the stated operating voltage range. 3. Initial inrush currents and repetitive peak currents are both electronically limited to the values shown. 4. Coded values are typical of the output measured with a temporal coded or a march time coded pulse and with a sound level meter reading on a "fast" setting. Under the same test conditions, coded hom output "peak" sound level readings are typically 4 dBA higher. Simplex Time Recorder Co. 3 S4903- 0010 -1 10/99 Installation Reference Mounting is compatible with r 1 0 V single gang, double gang, and I ' r ( 1 0 ( \ , , r 4" (102 mm) square boxes, _ 1 1/2" (38 mm) deep (by others )1,�,- / O /1o, O O- 1-61.--) U ) iI J J 1 J� O O ') / / - - / Wiring access hole � , � , - ' (� ` V Wiring terminals for .... At p ■ , 1 I SmartSync operation Mounting Holes: 4" Square (4) ] � Single gang ( n1Inll� 01 v Double gang (3) Transparent housing and lens assembly Cliii Removable cover (tool required) F 0 N. E Simplex Time Recorder Co. 4 S4903- 0010 -1 10/99 Side View, Surface Mount with Adapter Skirt and Wire Guard Options (Surface mount conduit and box shown for reference) 4" Square box profile, 1 1/2" (3388 mm) deep Ir _____ �__ Optional wire guard I 1I■ • 4905 -9961 • I■ EIS QuickAlert AN SO uncismom I.I Optional surface mount adapter skirt: 4905 -9937, Red; 4905 -9940, White (conduit knockouts on all four sides) 4905 -9931. Adapter Plate Installation Information 4905 -9931 Adapter Plate 2975 -9145 Box m-r7 O I �I�I�I� I Id�� �. 1 O O � 0 R 4 -Ii 1 Adapter Plat e 905 -993 0 4903 Series AN 4 4905 -9961 Optional Wire Guard (shown here for reference only, can be used on other mounting options) Simplex Time Recorder Co. 5 S4903- 0010 -1 10/99 • 4 Smart Sync Control Module (SCM) Additional SCM features: Model 4905 - 9938 SCM (Smart Sync Control Module) • Multi -Sync Mode. Up to eight SCMs can be provides an interface between standard NAC output and interconnected to synchronize system notification. Smart Sync two -wire controlled notification appliances. • NAC Powered. The SCM is powered from the strobe One NAC can be programmed to operate as control NAC. Dedicated power wiring is not required. "on-until-silenced" and would be designated as the horn • Isolated NAC Inputs. NAC inputs to the SCM are control (non- coded, on continuously during alarm). A isolated from each other and can be supplied from second NAC would be programmed to provide different control panels. "on-until-reset" operation and would be for the visible appliance (strobe) control (also non - coded, on • Class B (Style Y) and Class A (Style Z) operation are continuously during alarm). both supported. (Smart Sync Class A operation requires the 4905 -9938 SCM.) Coded Homs and Synchronized Strobes. In addition to operating the strobe and the horn • Earth fault detection protection is provided by the independently, the SCM can be switch selected to operate strobe control NAC during supervision mode. the horns as temporal coded, march time coded • Multi -Sync Isolation. The horn input NAC powers the (60 beats /minute), or on continuously. Strobes are Multi -Sync function and is isolated from the strobe activated with 1 Hz synchronized flashes. NAC wiring. • Multi -Sync Supervision. Multiple SCMs which are interconnected are supervised for proper circuit connection. 4905 - 9938 Smart Sync Control Module Installation Information. J 4905 -9938 SmartSync Control Module (SCM) � , 4" Square cover plate, 1 ‘ I ° RACO 752 or equal (by others) � II��I ,_ - ILI 4! Mounting Box (by others): Square box, 4" (102 mm), required depth depends on total conductor requirements. Minimum depth = 2 1/8" (54 mm), RACO 232 or equal. Extended depth (for maximum conductors), add 1 1/2" (38 mm) extension ring, RACO 201 or equal. Simplex Time Recorder Co. 6 S4903- 0010 -1 10/99 QuickA /ert Housin• Size Reference The Simplex QuickAlert family of notification appliances share a common overall size and appearance. This AN drawing is shown approximately full size for reference. 5" (127 mm) • f3 Simplex 5 1 18" (130 mm) r .. 00 1 L iiituyikafia a 1 Simplex Time Recorder Co. 7 S4903- 0010 -1 10/99 Simplex. the Simplex logo. IDNet, QuickAlert, and SmartSync are either trademarks or registered trademarks of Simplex Time Recorder Co. in the U.S. and/or other countries. S4903- 0010 -1 10/99 S'mP' Gardner, Massachusetts 01441 -0001 USA visit us on the world wide web at www.simplexnetcom All specifications and other information shown were current as of printing and are subject to change without notice. 5 Sim Iex QuickA /ertTM Notification Appliances ® p UL Listed; CSFM and SmartSyncTM Compatible Visible Notification NYC, MEA Approved* Appliances with Synchronized Flash Rates MEM r. 24 VDC powered xenon flashtube visible ' q , , fps notification appliance (strobe) for wall mounting: • UL listed to Standard 1971 A ,< • Models are available with 15, 75, or 110 candela • r�q. Strobe rating is clearly indicated on reflector • Compatible with ADA requirements • Diode polarized input for connection to reverse r. polarity, supervised notification appliance ' ' I P PP ? d F circuit (NAC) • In/out wiring is accessible from front of housing providing easy access for installation, inspection, ' : oshaiX and testing • Regulated circuit design ensures consistent output • Rugged, high impact, flame retardant thermoplastic housing available in red or white • Covers are available separately to convert housing color _ •' Synchronized flash rates for use with L =" FIR E `. • SmartSync two -wire control, when connected to a compatible fire alarm control panel NAC (refer to QuickAlert Visible Notification Appliances are Available in page 2 for details) Red with White Lettering and White with Red Lettering • SmartSync Control Module (SCM) model • escnptlon 4905 -9938 (required for Class A SmartSync operation) QuickAlert Strobes provide quick and convenient installation using a flexible mounting design. The strobe • Synchronization modules for Class B (Style Y) or housing is a rugged, one -piece assembly (including lens) Class A (Style Z) operation that mounts to single gang, double gang, or 4" square standard electrical box. Wiring terminals are accessible QuickAlert notification appliance design provides from the front of the housing, providing easy access for flexible, easy, and convenient semi - flush or installation, inspection, and testing. The cover can be surface wall mounting: quickly removed (a tool is required) and when in place, • Easily mounts to single gang, double gang, or the entire assembly is impact and vandal resistant. 4 -inch square outlet box Separate covers are available for color conversion. • In/out wiring terminals for 18 AWG to tro • e e ection 12 AWG wire • Rear of housing does not extend into box Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications Optional adapters and wire guard: of: the National Fire Alarm Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, • Mounting adapters are available to cover surface ICBO, or SBCCI; and the application guidelines of the mounted electrical boxes and to adapt to Simplex Americans with Disabilities Act (ADA). 2975 -9145 boxes • UL listed red wire guard is available for * This product has been approved by the Califomia State Fire Marshal (CSFM) pursuant to Section 13144.1 of the Califomia Health and Safety Code. See CSFM Listing 7125-0026:235 semi -flush or surface mounting for allowable values and/or conditions concerning material presented in this document It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. This product was not UCL listed or FM approve as of document revision date. Additional listings may be applicable, contact Simplex for the latest status. . _._. _. - - • :'ao 4.0003.2 2 /0 i ync ron ize • tro • es This operation has traditionally required two different Multiple Strobes. When multiple strobes and their circuits (four -wire operation). The Simplex SmartSync operation mode (patent pending) provides this function reflections can be seen from one location, synchronized using a single circuit (two -wire operation). flashes reduce the probability of photo- sensitive reactions as well as the annoyance and possible distraction of SmartSync two - wire control is available from: random flashing. Flash synchronization modules are • 4009 IDNet' • NAC Extender, models 4009 -9201 and available to control the observed flashes of synchronized 4009 -9301 (refer to data sheet S4009 -0002) flash models using a two -wire circuit (U.S. Patent No. • 4010 Fire Alarm Control Panel with operating 5,559,492). software Revision 2.X or higher (refer to data sheet S4010 -0001) �� •M•WIt • • SmartSync Control Module (SCM) 4905 - 9938, Background. Typically, fire alarm control panels provides a SmartSync interface to conventional activate both audible and visible notification upon receipt NACs and also is used with the 4009 IDNet NAC of an alarm. At the direction of an authorized operator Extender or 4010 Control Panels to provide Class A (or by pre - determined program), audible notification operation (refer to data sheet S4903 -0010 for more appliances may be silenced before the alarm condition is information) reset (on- until - silenced) while the visible notification Additional SmartSync compatible products include appliances are kept activated until the alarm condition is separate horns and combination horn/strobe AudibleNisible reset (on- until- reset). notification appliances. Contact Simplex for information on these related products. ' ro • uct e ection Synchronized /SmartSync Compatible Visible Notification Appliances (Strobes) es-tr i a, :mot. -7. - strobe output Rating -- - • MO -. _ _ . _ . - __ _ _ _ _ -- -- _ _ H ousing Color ta". , , `` F ". .• , —...15 cd 75 cd 110 cd 49049331 ... . 4904-9332 Red with white "FIRE" lettering 4904-9333 ■ 4904-9342 • " _ 49049343 ' •~ White with red .. "FIRE" lettering 4904-9344 Adapters i- 7 •, e . _:: r , ' ,, .: � :' pti -_`- - -. - ---- - -- - - Diinens ons' . - - Des on. i 4905 -9937 Surface mount red adapter skirt Use to cover 1 1/2" 5 3/8 H x 5 1/4" W x 1 5/8" D deep surface (136 mm x 133 mm x 41 mm) 4905 -9940 Surface mount white adapter skirt mounted boxes Total depth with strobe = 4 3/8° (111 mm) 4905 -9931 Adapter Plate, red, for mounting to Simplex 2975 -9145 box 8 5/16" x 5 3/4" x 0.060" Thick (typically for retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975 -9145 Red mounting box, requires Adapter Plate 4905 -9931 7 7/8" x 5 1/8" x 2 3/4" D (200 mm x 130 mm x 70 mm) Covers and Guard '-1 ,, , ' - 74 s crj ott 77_77_ _ -- - _ me - „D nstons - 71 "" 4905 -9959 Red cover with white 'FIRE' lettering 5 1/8" H x 5" W x 1 1/2° D 4905 -9960 White cover with red °FIRE° lettering (130 mm x 127 mm x 38 mm) 4905 -9961 Wire guard with mounting plate, UL listed, red, compatible with 6 1/16° H x 6 1/16° W x 31/8° D semi -flush or surface mounted boxes (154 mm x 154 mm x 79 mm) Synchronization Modules :z k , ; .• Ode7' '; `r De ptiad. -" .:77 . 'D T ensions— , 4905 -9938 - SmartSync Control Module, Class A or Class B (Style Z/Style Y), 4" x 4 1/8° x 1 1/4° D installs in 4° square box (refer to diagram on page 4) (102 mm x 105 mm x 32 mm) 4905 -9914 Synchronized Flash Module, Epoxy encapsulated with in /out Class B (Style Y) operation 18 AWG wire leads, rated for 1 3/8° x 2 7/16" x 13/16° 4905 -9922 Synchronized Flash Module, 2 A NAC, requires 10 mA for (35 mm x 62 mm x 20 mm) Class A (Style Z) operation power c:.. -.0..• r;.,e Do r., n ...,.� , �..,,.... �,..,. • .. tro•e peci icatlons Rated Voltage Range 22 to 29 VDC Operating Voltage Range 17.6 to 32 VDC See Note 1 below Flash Rate 1 Hz Strobe Output Nominal Average Current at 24 VDC Operating Current 15 cd 47 mA (see Note 2) 75 cd 134 mA 110 cd 191 mA Inrush /Peak Strobe Output 22 VDC 29 VDC Current i,,,1 trobe Performance Referenc N ',: Average. Currents and Inrush/Peak 16 cd i :':" ',. 55 mA .42 mA 98 mA ' .. i Currents. • ` (see Notes2 and 3) 75 cd - 152 mA - 114 - .258,mA 110 cd 192mA 167 mA. . 380mA Housing Dimensions (including lens) 5 1/8" H x 5" W x 2 3/4° D (130 mm x 127 mm x 70 mm) Temperature Range 32 ° F to 122 F (0 C to 50 C) Humidity Range 10% to 93 %, non - condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG NOTES: 1. These products operate to the nameplate rating requirements of UL Standard 1971 in effect at the time of the product listing. Requirements included demonstrating performance over the range of -20 % and +10% of the namplate rating as is stated as the operating voltage range. 2. These strobes supply rated light output at rated flash rate over the stated operating voltage range. 3. Initial inrush currents and repetitive peak currents are both electronically limited to the values shown. nsta ation "e erence Surface or Semi -Flush Strobe Mounting 7C...:Th LTh C.: 0 o Side View, Surface Mount with Adapter Mounting is compatible with i ( 1 0 ( 1 r Skirt and Wire Guard Options single gang, double gang, and 4" (102 mm) square boxes, /° ° - ° °, ° 1 1/2" (38 gang, double deep, by others — �� <0� — � (Surface mount conduit and • • • box shown for reference) _ A A , G 4" Square box profile, 1 1/2" (38 mm) deep NV :::::::te ��I / Optional wire guard g iIII® I , 0 1111 _ 16:- ° ° MUM ' • / Mounting Holes: W "� 4" Square (4) memo= ..,„ �' 1 1 QuickAleR . , Single gang (2) Strobe all - Cll Double gang (3) t ' = IIIIIIMP MEI 1.--- Transparent housing and lens assembly Optional surface mount adapter skirt: 4905 -9937, Red; 4905 - 9940, White Removable cover (conduit knockouts on all four sides) \` F 11 ( _ (tool required) ;..,.,tev r;..ne oe....-.+e. r„ ', SA904 0003 -2 2 /00 • • • 1 - • • : mart ync ontro ' o • u e I 7e erence peci ications 22 to 29 VDC, with maximum ripple of Rated Input Voltage Range 2 V peak -to -peak Refer to Note 1 on page 3 Operating Input Voltage Range 17.6 to 32 VDC SmartSync NAC Output Capacity 2 A maximum (total device quantity is control panel dependent) Strobe Control NAC Input Current Output NAC current, plus 30 mA @ 24 VDC for SCM operating power Horn Control NAC Current 4 mA @ 24 VDC Class A Operation Mounting Requirement Mount SCM within 20 ft (6 m) of control panel, use metal conduit • • • - • • : mart ync ontro I o• u e nsta ation n ormation $•: _ Q O Q Mounting Box (by others), 4" square ' Q (102 mm), required depth depends on O total conductor requirements: (? �` , O 1. Minimum depth = 2 1/8" (54 mm), I ` 0 RACO 232 or equal. • I ���, �, Q ,I Q 2. Extended depth (for maximum conductors ), add 1 1 /2" mm) ri , RACO 201 (38 or ual. \ '1c�‘ � Q Q extension 9 q %;),;' > 0 4905 -9938 SmartSync Control Module (SCM) 4" Square cover plate, RACO 752 or equal (by others) • 1 - • • • apter ' atel nsta ation n ormation 2975 -9145 Box 4905 -9931 4.--- Adapter Plate � I 1 n 1 / • L , o It( J k HHHHHHI .. _ if . - IF I 0 1 0 ,- 0 I 4904 Series Strobe �w n � � RI i O I / Adapter Plate � 0 w � � �_ 9 F ill ./ 4- O 4905 -9961 Optional Wire Guard (shown here for reference only, can be used on other mounting options) Simples, the Simples logo, IDNet, QuickAlert, and SmartSync are either trademarks or registered trademarks of Simples Time Recorder Co. in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). S4904- 0003 -2 2/00 E Simplex Westminster, Massachusetts 01441 -0001 USA ® visit us on the world wide web at www.simplexnetcom • Multi- Application Peripherals !Simplex and Accessories Miscellaneous Devices, Control Relays UL Listed Track Mounted /Encapsulated (Air Products) 4098 -9843 and 2088 Series FEATURES • • UL listed as control unit accessory �1 7Q�!! J!7p!!!!1AltlRJQ�l.. !w...►1 • Track mount package availability: oolol��nl 6, 1.l olo: olo5l6It5loieiolo l�?III�?I°I5∎0161a1 - Single or four relay module, with or without o o O ° enclosure, with SPDT or DPDT contacts en en e•1 . e= - LED indicates relay coil status a "° ° gr "'° "' ® ° a'Z y • �; °I " • • 5 • • 15,1 • • 665151° • - Enclosures provide status LED viewing ports - Multiple coil voltage inputs, diode polarized • - Modules are track mounted with "Snap- Apart" feature design Model 2088 -9020, Four DPDT Relay Package with Enclosure (shown with cover removed) • Single encapsulated SPDT relay package with color coded #18 AWG wire leads, available in two versions: - 2088 -9021 Provides diode polarized multiple input voltage ability and LED indication - 4098 -9843 Provides a diode polarized 24 VDC coil with In /Out wiring 1 , SPECIFICATIONS (refer to page 2 for dimensions) Vii' i ; Track Mount Relays BLU Contact Ratings 10 A @ 115 VAC, resistive RED ORG Coi Voltage 18 -35 VACNDC, 115, or 230 VAC Coil Current • SPDT models = 15 mA Encapsulated Relay Package • DPDT models = 35 mA (typical of 2088 -9021 and 4098 -9843) Terminal Block Ratings up to # 14 AWG Encapsulated Relays Connections I # 18 AWG color -coded wire leads DESCRIPTION These multi - purpose control relays offer SPDT or 2088 - 9021 DPDT, 10 Amp contacts in a variety of mechanical • Contact Ratings 10 A @ 115 VAC, resistive packages. Models are available for coil operation by Voltage 18-35 VACNDC, 115, or 230 VAC one of four input voltages allowing a single relay to be Coil Ratings energized from a voltage source of 18 -35 VDC or VAC, Current 15 mA @ 24 VACNDC, 115, or 230 VAC 115 VAC, or 230 VAC (not available with 4098 - 9843). 4098 - 9843 Voltage selection is made by wiring to the appropriate Coil Ratings 18 -35 VDC input, 15 mA © 24 VDC input terminals. • 10 A @ 115 VAC Each relay model (except model 4098 -9843) contains a Contact Ratings 7 A @ 28 VDC red LED which indicates that the relay coil is energized. • 250 µA @ 5 VDC Mounting options are varied for application flexibility. General Specifications (all models) Track mounted relays may be "snapped apart" from a Temperature Range -58° F to 185° F ( -50° C to 85° C) standard four - module assembly and used independently if desired. © 1999 Simplex Time Recorder Co. All rights reserved. S2088 0010 - 2/99 J RELAY SELECTION CHART Product ID Model Relay Relay Packaging Dimensions Type Quantity 2088 -9007 MR -101/T SPDT 3" H x 2 1/8" W x 1 1/2" D Track mount, without enclosure 2088 -9009 MR -201/T DPDT ( 76 mm x 54 mm x 38 mm) Single 2088 -9008 MR -101/C SPDT 6 1/8" H x 3 1/4" W x 2 1/2" D Track mount with enclosure 2088 -9010 MR -201/C DPDT ( 156 mm x 83 mm x 64 mm) 2088 -9017 MR -104/T SPDT 3" H x 8 1/2" W x 1 1/2" D Track mount, without enclosure 2088 -9019 MR -204/T DPDT ( 76 mm x 216 mm x 38 mm) Four 2088 -9018 MR -104/C SPDT 6 1/8" H x 9 1/2" W x 2 1/2" D Track mount with enclosure 2088 -9020 MR -204/C DPDT ( 156 mm x 241 mm x 64 mm) Encapsulated, multi - voltage coil, color 1 1/2" H x 1" W x 7/8" D 2088 -9021 PAM -1 coded #18 AWG wire leads, with coil (38 mm x 25.4 mm x 22 mm) SPDT Single status LED 4098 -9843 PAM -SD Encapsulated, 24 VDC coil, color 1 1/2" H x 1 3/16" W x 13/16" D coded #18 AWG wire leads (no LED) (38 mm x 30 mm x 21 mm) TRACK MOUNT RELAY WIRING REFERENCE SPDT contacts rated DPDT contacts rated 10 A @ 115 VAC, resistive / 10 A @ 115 VAC, resistive ® NC C NO NC C NO NC C NO ®® tt ®® ®® Relay energized LED - ( I I I ® ® ® ® ® ® ®® O 0 18/24 115 230 ® 0 18/24 115 230 ® (18 -35) VDC ( -) ( +) (18 -35) VDC ( -) (+) Coil voltage Coil voltage (note polarity (18 -35) VAC AC AC (note polarity (18-35) VAC AC AC for DC) 115 VAC N V for DC) 115 VAC N V 230 VAC V V 230 VAC V V Terminal strip connections Terminal strip connections SPDT models DPDT models Simplex and the Simplex logo are registered trademarks of the Simplex Time Recorder Co. S2088- 0010 -6 2/99 Simplex Gardner, Massachusetts 01441 -0001 U. S. A. Offices and Representatives Throughout the World Visit us on the world wide web at www.simp/exnet.com. All specifications and other information shown were current as of printing and are subject to change without notice. : Et SimpIex 6,.. ADA 100® Emergency CaII System 2080 -9025 MASTER STATION 2080 -9026 AREA STATION TION STANDARD FEATURES: ' _ ' • Vandal Proof 16 gauge Stainless Steel —. Construction • Area Station Supervision Circuits I a • Large 3" "PUSH FOR HELP Button • • Dual Audio & Visual Alarms for the ""'1'""°" Hearing and Visual Impaired • Custom Engraved Area Station Location .. L ___ i . s .. - Labels A./G1D G1 M • Keyed Master Station Reset Switch .�T • Modular Design provides for any number „,�,�5� ....sn►.io. of Areas Stations . -: . • No Telephone Lines Needed a - -a 1 1 1 i -- OPTIONAL FEATURES: 1 ("r • Recorded Voice Dialer or Pager Option • UL Listed Battery Backup System '""'""°CLIP MIMES • • Engraved Replaceable Directory • Master Station Desktop Base TYPICAL ADA 100 3 AREA STATION SYSTEM • 110 Candela Area Station Flashing Strobe SYSTEM OPERATION: Light Depressing the "PUSH FOR HELP” button on an Signs Stainless Steel Area Station places the system in "HELP • Braille Instructional Si 9 ( REQUESTED' mode, illuminates the HELP Frame) REQUESTED" LED at the Area Station, a red • Master and Area Stations available in LED at the Master Station (corresponding to that Polished Solid Brass and Brushed Solid specific Area Station), and sounds the 90 dbA Brass Housings piezoelectric alarms at both the Area and Master • Weather Hood (Stainless Steel or Solid Stations. The security attendant presses the Brass) "TALK' button on the Master Station to and the • Illuminated Area of Rescue Assistance acknowledge both the audio alarm Signs (with Independent Battery Backup) illuminated red LED at the Master Station, which silences the audio alarms at both the Master and • Custom Sizes'Available Area Station(s) and illuminates the °HELP • Multiple Master Stations COMING" LED light at the Area Station. This also enables two-way communication between the DESCRIPTION: Master Station and the Area Station permitting the The ADA 100 is a modular, hands -free security attendant to converse with the individual Emergency Cali System with dual audio and requesting assistance. Tuming the reset switch visual alarms and built-in supervision capabilities at the Master Station extinguishes the °HELP designed to comply with the Americans with COMING" LED indicator at each Area Station, the Disabilities Act It is fully expandable and may red LEDs at the Master Station, and resets the he used as an independent system (with its own system. The Master Station attendant using the attery backup system) or in conjunction with °TALK" and "LISTEN" buttons labeled for each other annunciator or fire alarm systems. Area Station's location controls all conversations. ADA 100 EMERGENCY CALL SYSTEM t COMPONENT DESCRIPTIONS The system monitors for AC power failure, AC MASTER STATION and DC surge suppression, and no/low battery indications. The system includes two (2) 12VDC The Master Station is the heart of the system sealed lead acid batteries (rated @ 4.5 amp from which all calls are controlled. It should be hours each), a 1.0 amp battery charger capable of mounted in an appropriate and secure area charging two internally mounted batteries in 12 typically adjacent to other security equipment. hours, a 24VAC 20VA transformer, and has a The ADA -100 Master Station accommodates up continuous output of 800mA. to 60 Area Stations. Master Stations are AMPLIFIER available in the following sizes: Located in the Amplifier Cabinet or Battery Back - 1- 5 Area Stations 6-10 Area Stations up System Cabinet, the Housing Devices, Inc. 11 -15 Area Stations 16-20 Area Stations ADA-35 Amplifier processes the audio for the 21 -25 Area Stations 26-30 Area Stations entire system. 31-35 Area Stations 36-40 Area Stations 41-45 Area Stations 46-50 Area Stations BFtAILLE INSTRUCTIONAL SIGN 51 -55 Area Stations 56-60 Area Stations The Braille Instructional Sign, captioned in both The ADA -100 system can utilize multiple Master English and Braille, is placed next to each Area Stations to accommodate larger systems of any Station in the system and reads: size. The Master Station also contains the °FOR ASSISTANCE PUSH 3 INCH HELP BUTTON' system °Reset' key switch. AREA STATION ILLUMINATED AREA STATION SIGN Area Stations are stainless steel vandal proof An optional illuminated sign is placed above each Area Station for easy visual identification of the intercoms with piezoelectric alarms, red LED Area Station's location. indicators, and a large 3' panic button labeled °PUSH FOR HELP'. Area Stations should be MOUNTING SYSTEMS & mounted in areas where they are visible and DIMENSIONS easily accessible by anyone needing help. Specify either a surface or flush mount installation RELAY CARD CABINET for each Master Station and Area Station. Flush The standard size Relay Card Cabinet holds up mounting is accomplished using a back box and to 10 Relay Cards. Each Relay Card provides surface mounting using a Surface Mounting the electronics support for one Area Station. Collar. Master Station back box dimensions are: Larger systems will use larger cabinets and more • 7 5 / x 7 5 /� x 3 / (1 -5 Areas) Relay Cards. • • 13 /2' x 7 /e x 3 /2' (6-10 Areas) Larger systems have custom sized back boxes.' RELAY CARD Area Station back box size is: 7 5 / 8 6 x 7 5/9 x 3 '/ 2 °. The Relay Card is the electronic brain for each Surface Mounting Collar Dimensions are: 9 1 / 4 ' x Area Station. One card is required for each Area 9 '/4 x 2' (Area Station); 11 '/ x 11 1 /4' x 2'/: Station used in the system. The Relay Card also (Master Station with 1 -5 Areas); Larger Master , contains a replaceable SCR chip. CONTROL BOARD Station Surface Mounting Collars are custom sized.' The Control Board, also located in the Relay Relay Card Cabinets, Battery Backup and Card Cabinet, provides electronic support for Amplifier Cabinets are 12' x 12' x 4° (10 Area both the Master Station and all Area Stations. Stations or less). Larger cabinets are required for systems with more than 10 Area Stations.' BATTERY BACKUP SYSTEM Master Stations can be custom sized to The Battery Backup System provides continuous accommodate larger numbers of Area Stations. power to the ADA 100 system in the event of a Specify engraving for the Master Station. power failure. The system features auto- Engraved directories will be used in lieu of resetting overload protection, visual AC and DC surface engraving on the Master Station if the power indicators and built-in battery charger engraving is not specified at the time of order. circuitry. ' Contact manufacturer for dimensions. • .- t e ` : A.DA- 1 0 O . r tr 4 " X * S . ... pax _,- k ,. ,...... - ction 7 Elderly, Handicapped & Infirm: An ADA -style Emergency Call System t F - jj�� r n i eG # + , + T t {�g. "�` _ �: ��' + _ n r ' 4 •49.71p•N"F1� .s' 4 % 7 '471";-4- ^V.y . '" z•�.'..ss;r.•. '` ' d9 '" f - TALK" LISTEN TROUBLE ••.•.•:... ® ■ BASEMENT 7. 1.;r.r . •HELP REQUESTED t � : ; ..y,, - •t`i:.r..+•+. �� L ` 4 5 � Q , N , spree..•:• , . • .� i « .. A .I . ..4 STAIR f • . • '•.•:• • •. > 3 „ , • »,• • • .:., • •.yr.• . r•••••. .. �. ,.. t... •...••. 2ND FLNE - _ • HELP COMING:' s p 3 , ...••.• Q • STAIR y , { ' - - f• • •• • • TALK LISTEN - • `a r� ' ' � f``',-s//a \.'��. u rj`. {`^'" ` 4,9 f,`"WX 7 :i : r t..) R.,,,,-,-..4A, - ....,Arip-,, 0 °y ELPX far = RESE - ..' , ;'r , r`i,{ . '. ' '+ sr, * ` ~ POWER v ^ . i w' '9 x 1 x y P x 2080 -9026 AREA STATION 2080 -9025 MASTER STATION JUMBO Push For Help button + vandal proof construction • Separate Talk and Listen controls • Up to ninety area stations supported • Great quality • No telephone lines needed • 16 gauge stainless with engraved lettering • Keyed reset switch • Built -in supervision alerts in case of system problems Intelligent System Design! • Button is pressed at Area Station. • Help Requested light flashes, alarm sounds. • At Master Station, zone light flashes, alarm sounds. • Pressing "talk" acknowledges call, silences alarms, enables two -way audio. • At Area Station, Help Coming light turns on. • Turning Key Reset, clears call and returns system to standby. 6%. Be S implex • 4 ADA -100 secti Wiring Diagram Master Station Area Station Irma Zone (Roo LED .I T �" •••••� 0 • � Lade Rea I.ED.I o /PUS Paws. /Gm. LED./ -*ill FOR HELP I ` / Area Station WIRE & CABLE LEGEND o - 0 (3) 14 AWG wires for 120V Relay Card Cabinet (3) " " "' 0-- AC. Power from a ° Pus dedicated emergency FOR power branch circuit HELP 0 0 Q One 18AWG 4 twisted pair Overall shielded cable such as Belden 9554, west Penn 3753 or equal plus (3) Area Station 18 AWG conductors (shier' Battery Bock Up Cabinet ° not required) for each remote station o ADA - 30 Amplifier o/ FOR © One 18 AWG 4 twisted pair ADA - 24V Transformer H�� overall shielded cable Battery o ° from each remote area Charger station to the relay cabinet. 0 One 18AWG 4 twisted pair overall shielded cable from battery back up to relay 120V AC Power cabinet NOTES 1 For each ADA - 100 emergency call system specify either surface or flush mounting for both master and area stations (flush units require back boxes 7 ' x 7 I /2" x 4 "). 2 For systems with 10 area stations or less, area station control modules (relay card cabinets and battery back up cabinets) are 12" x 12" x 4 "d. For systems with more than 10 area stations, larger cabinets are required. 3 Master station can accommodate up to 90 area stations 4 Specify engraving for master station and for each area station. 5 Directories may be used in lieu of engraving for master station if desired. • A DA -100 Section 7 Inspired by the requirements of the American Disabilities Act, the ADA- Technical 100 allows facilities managers to provide the highest standard of safety and Information security at a modest installed cost. The large "Push for Help" button immediately alerts the user that "help is requested" and also that "help is coming" (after the call has been acknowledged at the Master). Voice communications are clear and reliable and the system supports as many as 90 area stations. For those installations that do not require an interface to a telephone line or a shared voice /data bus, the ADA 100 provides a cost - effective solution. I SPECIFICATIONS I CALL STATION I LOCAL MASTER ALERTS I Son-Alert I Speaker DISPLAYS I LE.D.s I L.E.D.s CONTROLS Vandal Proof Buttons I Plastic Buttons WIRING I Direct I Direct DISTANCE 13000 Feer 3000 Feet DIMENSIONS Flush: 9" x 9" x 2" Flush: 10 5/8" x 7 5/8" Surface 8" x 8" x 2" Surface: 8" x 8" x 2" BACK BOX 17 5/8" x 7 5/8" x 3 1/2" 17 5/8" x 7 5/8" x 3 1/2" MODES Stand By Stand By Help Requested Help Requested Help Coming Help Coming On-Hold On -Hold Two-Way Talk Two -Way Talk POWER I Uninrerruprable I Uninterruprable