Packaged
Gas /Electric
Rooftop Units
VoyagerTM
3 through 25 Tons — 60 Hz
4:
k C'
.7, _
- --: -- •
r i
,,
a f
•
` - ......
1
•
•
e :
; ,
..
0 _
'r7tavE General 3 , 4 Ton
Data Standard Efficiency
•
Table 9-1 General Data
3 Ton Downflow Units 4 Ton Downflow and Horizontal Units
YCD036C1 YCD036C3, C4 YC *048C1 YC*048C3, C4,'CW
Cooling Performance' "s• , o .
Gross Cooling Capacity 37,400 37,400 49,900 48,900
SEER 10.00 10.00 10.00 10.00 ., ''
SEER' e < i, -�.ss
Nominal CFM / ARI Rated CFM 1200/1200 1200/1200 1600/1600 1600/1600
ARI Net Cooling Capacity 36,000 36.000 48,000 47,000
System Power (KW) 4.01 3.99 5.34 5.26
Heating Performance'
Heating Models Low High Low High Low High Low High
Heating Input (Btuh) 80,000 120,000 80,000 120,000 90,000 120,000 90.000 120,000
Heating Output (Btuh) 62,000 94,000 65,000 97,000 70,000 94,000 73,000 97,000
('AFUE % ' 78 78 81 81 78 78 81 81
Steady State Efficiency (%) 80 80 81.0 81.0 80.0 80.0 x81.0, 81.0
No. Burners 1 1 1 1
No. Stages 1 1 1 1
Gas Connection Pipe Size (in.) 1/2 1/2 1/2 1/2
Compressor
No./Type 1 /Climatuff® 1 /Climatuff 1 /Climatuff 1 /Climatuff
Sound Rating (BELS) 8.2 8.2 8.6 8.6
Outdoor Coil - Type Hi- Performance Hi- Performance Hi- Performance Hi- Performance
Tube Size (in.) OD .375 .375 .375 .375
Face Area (sq ft) 5.87 5.87 7.43 5.87
Rows /FPI 2/16 2/16 2/16 2/16
Indoor Coll - Type Hi- Performance Hi- Performance Hi- Performance Hi- Performance
Tube Size (in.) .375 .375 .375 .375
Face Area (sq ft) 3.67 3.67 4.83 4.83
Rows/FPI 2/15 2/15 2/15 2/15
y i' Refrigerant Control Short Orifice Short Orifice Short Orifice Short Orifice
Drain Connection No. /Size (in.) 1/ 3/4 PVC 113/4 PVC 1/ 3/4 PVC 1/ 3/4 PVC
Outdoor Fan - Type Propeller Propeller Propeller Propeller
No. Used /Diameter (in.) 1/24 1/24 1/24 1/24
Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1
CFM 3150 3150 3940 3630
No. Motors /HP 1/.25 1/.25 1/.33 1/.33
Motor RPM 850 850 1075 1075
Indoor Fan - Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal
No. Used /Diameter (in.) 1/9 X 9 1/9 X 9 1/12 X 9 1/12 X 9
Drive Type /No. Speeds Direct/2 Direct/2 Direct/2 Direct/2
No. Motors 1 1 1 1
Motor HP (Standard /Oversized) .33/.40 .33/.40 .50/.75 .50/.75
Motor RPM (Standard /Oversized) 1075/1400 1075/1400 850/1040 850/1040
Motor Frame Size (Standard /Oversized) 48/48 48/48 48/48 48/48
Filters - Type Throwaway Throwaway Throwaway Throwaway
Furnished? - Downflow Yes Yes Yes Yes
Horizontal - - Yes Yes
(No.) Size Recommended (2) 20 X 25 X 1 (2) 20 X 25 X 1 (2) 20 X 25 X 1' (2) 20 X 25 X 1'
Refrigerant Charge (Lbs of R -22) 5.6 5.6 6.6 5.6
NOTES
1. Cooling Performance is rated at 95 F ambient. 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and
includes the effect of fan motor heat. Units are suitable for operation to 120% of nominal cfm. Rated in accordance with ARI Standard 210/240 or 360.
2. SEER is rated at ARI conditions and in accordance with DOE test procedures.
3. Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards. Ratings
shown are for elevations up to 2000 feet. For elevations above 2000 feet. ratings should be reduced at the rate of 4% for each 1000 feet above sea level.
4. AFUE is rated in accordance with DOE test procedures.
5. Sound Rating is rated in accordance with ARI Standard 270 or 370.
6. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.
7. YCH048C model requires (2) 16 x 25 x 1 filters.
8. Horizontal models have 8.95 SEER.
4.
*Indicates both downflow and horizontal units.
9
i � Y . •. . . _ ..; ra .. qK.- .-. 'N. N,Y . a1F' r" .;.. , -' w M ''` _ , p.1 , ?:,', C.. : u '..,. a . _ Y.c _ ,, , ..
.. e yr T'°W
General 5 61/4, 71/2. `ion
Data Standard Efficiency
•
■
Table 10 -1 General Data
61/4 Ton Downflow 71/2 Ton Downflow and Horizontal
C6 Ton Downflow and Horizontal and Horizontal Single Compressor Dual Compressor
YC*060C1 r YC>a060C3, C4. CW YC*075C3. C4. CW YC*090C3, C4, CW YC*090D3, D4, DW
Cooling Performance'
Gross Coofing Capacity 64,000 62,500 75.000 92,000 90,000
EER /SEER -/9.85 - /10.00 9.00/- 9.00 9.00 -
Nominal CFM / ARI Rated CFM 2,000/2,000 2,000/2,000 2,500/2,188 3,000/2,625 3,000/2,625
ARI Net Cooling Capacity 61,500 60,000 72.000 88,000 86,000'
Integrated Part Load Value' - - - - 9,4
System Power (KW) 6.95 6.71 8.00 9.78' 9.56'
Heating Performance'
Heating Models Low High Low High Low High Low High Low High
Heating Input (Btuh) 90,000 135,000 90,000 135,000 120,000 205,000 120,000 205,000 120,000 205,000 '
1st Stage (2 Stage Only) 150,000 150,000 150,000
Heating Output (Btuh) 70,000 105,000 73,000 109,000 97,000 166.000 97,000 166,000 97,000 166,000
1st Stage (2 Stage Only) 122,000 122,000 122,000
j AFUE %5 / 78 78 -` 81 ". B1 81 81 81 81 81 81
Steady State Efficiency ( %)' 80.0 80.0 1 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0
No. Burners 1 - 1 1 1 1
No. Stages 1 1 1 2 1 2 1 2
Gas Connection Pipe Size (in.) 1/2 1/2 1/2 1/2 1/2
Compressor
No./Type 1 /Climatuff® 1 /Climatuff 1 /Climatuff 1/Trane H 2/Climatuff
Sound Rating (BELS)' 8.6 8.6 8.8 8.8 8.8
Outdoor Coil - Type High - Performance High- Performance High- Performance High - Performance High- Performance
Tube Size (in.) OD .375 .375 .375 .375 .375
Face Area (sq ft) 11.32 9.76 11.32 12.09 14.00
Rows/FPI 2/16 2/16 2/16 2/16 2/16
Indoor Coil - Type High- Performance High - Performance High - Performance High - Performance High- Performance
Tube Size (in.) .375 .375 .375 .375 .375
Face Area (sq ft) 6.33 6.33 7.00 7.88 7.88
Rows/FPI 2/15 2/15 2/15 3/15 2/15
Refrigerant Control Short Orifice Short Orifice Short Orifice Short Orifice Short Orifice
Drain Connection No. /Size (in.) 1/ 3/4 PVC 1/ 3/4 PVC 1/ 3/4 PVC 1/ 3/4 PVC 1/ 3/4 PVC
Outdoor Fan - Type Propeller Propeller Propeller Propeller Propeller
No. Used/Diameter (in.) 1/24 1/24 1/24 1/24 1/24
Drive Type /No. Speeds Direct/1 Direct/1 Direct/1 Direct/1 Direct/1
CFM 4,900 4,270 4,870 5,450 5,620
No. Motors /HP 1/.50 1/.40 1/.50 1/.50 1/.50
Motor RPM 975 1,075 1,075 1,075 1,075
Indoor Fan - Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal
No. Used/Diameter (in.) 1/12 X 9 1/12 X 9 1/12 X 9 1/12 X 9 1/12 X 9
Drive Type/No. Speeds Direct/2 Direct/2 Belt/1 Belt/1 Belt/1
No. Motors 1 1 1 1 1
Motor HP (Standard /Oversized) .60/.75 .60/.75 1.0/2.0 1.0/2.0 1.0/2.0 .
Motor RPM (Standard /Oversized) 850/1040 850/1040 1725/1725 1725/1725 1725/1725
Motor Frame Size
(Standard /Oversized) 48/48 48/48 56/56 56/56 56/56
Filters - Type Throwaway Throwaway Throwaway Throwaway Throwaway
Furnished ?- Downflow Yes Yes Yes Yes Yes
- Horizontal Yes Yes Yes Yes Yes
(No.) Size Recommended (2) 20 X 25 X 1 (2) 20 X 25 X 1 (3) 16 X 25 X 1 (3) 16 X 25 X 1 (3) 16 X 25 X 1
Refrigerant Charge (Lbs of R -22)' 8.4 7.9 9.1 10.6 6.3 /Circuit
NOTES
1. Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb. 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and
includes the effect of fan motor heat. Units are suitable for operation to :20% of nominal cfm. Rated in accordance with ARI Standard 210/240 and 360.
2. EER and /or SEER are rated at ARI conditions and in accordance with DOE test procedures.
3. Integrated Part Load Value is based on ARI Standard 210/240 or 360. Units are rated at 80° F ambient, 80' F entering dry bulb, and 67° F entering wet bulb at ARI rated cfm.
4. Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards.
Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet. ratings should be reduced at the rate of 4% for each 1000 feet above sea level.
5. AFUE is rated in accordance with DOE test procedures.
6. Sound Rating is rated in accordance with ARI Standard 270 or 370.
7. Refrigerant cnarge is an approximate value. For a more precise value, see unit nameplate and service instructions.
8. YCH090C. high heat has 86,000 Btuh ARI Net Capacity, 9.66 system KW, and 8.9 EER. •
9. YCH090D. high heal has 85.000 Btuh ARI Net Capacity, 9.55 system KW, 8.9 EER and 9.1 IPLV.
10. YCH high heat models 2.0 HP standard motor
•
*Indicates both downllow and horizontal units.
10
MINE
General 171/2, 20, 25 Ton
Data High Efficiency
t
Table 20-1 General Data
17 Ton 20 Ton 25 Ton Units
Downflow and Horizontal Units Downflow and Horizontal Units Downflow and Horizontal Units
YC *211 C3,C4,C W YC *241 C3,C4,C W YC*301C3,C4,CW
Cooling Performance'
Gross Cooling Capacity 220,000 268,000 300,000
EER 11.0 10.6 10.4
Nominal CFM / ARI Rated CFM 7,000 / 6,200 8,000 / 7,000 10,000/8,750
ARI Net Cooling Capacity 208,000 250,000 278,000
Integrated Part Load Value' 12.0 11.2 11.0
System Power (KW) 18.91 23.58 26.73
Heating Performance'
Heating Models Low High Low High Low High
Heating Input (Btuh) 250,000 350,000 250,000 400,000 250,000 400,000
1st Stage 175,000 250,000 175,000 300,000 175,000 300,000
Heating Output (Btuh) 203,000 284,000 203.000 324,000 203,000 324,000
1st Stage 142,000 203,000 142.000 243,000 142,000 243,000
AFUE % = (Downflow /Horizontal) ( _80.2 / 81.0 79.3 / 79.7 80.2 / 81.0 79.8 / 79.7 80.2/81.0 79.8/79.7
Steady State Efficiency ( %) C 81.0 ( 81.0 81.0 81.0 81.0 81.0
No. Burners 1 1 1 1 1 1
No. Stages 2 2 2 2 2 2
Gas Connection Pipe Size (in.) 1/2 3/4 1/2 3/4 1/2 3/4
•
Compressor
No./Type 2/Trane 3-D® Scroll /Copeland Scroll 2/Trane 3-D Scroll 2/Trane 3-D Scroll
Sound Rating (BELS) 9.4 9.4 9.4
Outdoor Coil - Type High- Performance High - Performance High Performance
Tube Size (in.) OD 0.375 0.375 0.375
Face Area (sq ft) 35.30 35.30 35.30
Rows/FPI 3/16 3/16 3/16
Indoor Coil - Type High- Performance High- Performance High Performance
Tube Size (in.) 0.375 0.375 0.375 0
Face Area (sq ft) 26.00 26.00 26.00
Rows /FPI 4/15 4/15 4/15
Refrigerant Control Short Orifice Short Orifice Short Orifice
Drain Connection No./Size (in.) 1/1.0 NPT 1/1.0 NPT 1/1.0 NPT
Outdoor Fan - Type Propeller Propeller • Propeller
No. Used/Diameter (in.) 2/26 2/26 2/26
Drive Type /No. Speeds Direct/1 Direct/1 Direct/1
CFM 12,800 13,700 13,700
•
No. Motors /HP 2/1.0 2/1.0 2/1.0
Motor RPM 1125 1125 1125
Indoor Fan - Type FC Centrifugal FC Centrifugal FC Centrifugal
No. Used/Diameter (in.) 1/18 x 18 1/18 x 18 1/18x18
Drive Type/No. Speeds BELT /1 BELT /1 BELT /1
No. Motors 1 1 1
Motor HP (Standard /Oversized) 5.0/7.5 5.0/7.5 7.5
Motor RPM ( Standard/ Oversized) 3450/3470 3450/3470 3470
Motor Frame Size (Standard /Oversized) 145T/184T 145T/184T 184T
Filters - Type Throwaway Throwaway Throwaway
Furnished? Yes Yes Yes
(No.) Size Recommended (4)20 X 20 X 2/(4)20 X 25 X 2 (4)20 X 20 X 2/(4)20 X 25 X 2° (4)20 X 20 X 2/(4)20 X 25 X 2°
Refrigerant Charge (Lbs of R -22)' /Circuit 25.7/12.5 21.8/21.8 24.5/24.5
NOTES:
1. Cooling Performance is rated at 95F ambient, 80F entering dry bulb, 67F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net
and includes the effect of fan motor heat. Rated in accordance with ARI Standard 210/240 or 360
2. EER is rated at ARI conditions and in accordance with DOE test procedures.
3. Integrated Part Load Value is based On ARI Standard 210/240 or 360. Units are rated at 80F ambient, 80F entering dry bulb, and 67F entering wet bulb at ARI rated cfm.
4. Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards
Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level.
5. AFUE and Steady State Efficiency is rated in accordance with DOE test procedures.
6. Sound Rating is rated in accordance with ARI Standard 270 or 370.
7. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.
8. Horizontal Models have 8 -20 x 25 x 2 filters. ��
*Indicates both downflow and horizontal units.
20
General 25 Ton
Data Standard Efficiency
Table 14-1 General Data
25 Ton Downflow and Horizontal Units
YC *300B3,B4,BWL (j YC*30083,B4.BWH
Cooling Perfonnance'
Gross Cooling Capacity 290,000
EER 9.7
Nominal CFM / ARI Rated CFM 10,000 / 8,750
ARI Net Cooling Capacity 272,000
Integrated Part Load Value' 9.8
System Power (KW) 28.05
Heating Performance'
Heating Models Low •High
Heating Input (Btuh) 250,000 400,000
1st Stage 175,000 300,000
Heating Output (Btuh) 203,000 324,000
1st Stage 142,000 243,000
AFUE ( %) Downflow/Horizontal 80.2/81.0 79.8/79.7
(Steady _State Efficiency ( %) 81.4/81.0 '
No. Burners 1
No. Stages 2
Gas Connection Pipe Size (in.) 1/2 3/4
Compressor
No./Type 2/Trane 3 -D® Scroll
•
Sound Rating (BELS)e 9.4
Outdoor Coll - Type Hi- Pertormance
Tube Size (in.) OD .375
Face Area (sq ft) 36.43
Rows/FPI 2/16
Indoor Coil - Type Hi-Performance
Tube Size (in.) • .375
Face Area (sq ft) 26.00
Rows/FPI 3/15
Refrigerant Control Short Orifice
Drain Connection No. /Size (in.) 1/1.00 NPT
Outdoor Fan - Type Propeller
No. Used/Diameter (in.) 2/28
Drive Type /No. Speeds Direct/1
CFM 16,700
No. Motors /HP 2/1.0
Motor RPM 1,125
Indoor Fan - Type FC Centrifugal
No. Used/Diameter (in.) 1/18 X 18
Drive Type/No. Speeds Belt/1
No. Motors 1
Motor HP (Standard /Oversized) 7.5/NA
Motor RPM (Standard /Oversized) 3470/NA
Motor Frame Size (Standard /Oversized) 184T/NA
Filters - Type/Furnished? Throwaway/Yes
(No.) Sze Recommended (4) 20 X 20 X 2
(4) 20 X 25 X 2
Refrigerant Charge (Lbs of R -22)' 17.0 /Circuit
NOTES
1. Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and
includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Rated in accordance with ARI Standard 210/240 or 360.
2. EER is rated at ARI conditions and in accordance with ARI Standard 210/240 or 360.
3. Integrated Pan Load Value is based on ARI Standard 210/240 or 360. Units are rated at 80° F ambient, 80° F entering dry bulb, and 67° F entering wet bulb at ARI rated cfm.
4. Heating.Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards. Ratings
shown are for elevations up to 2000 feet. For elevations above 2000 feet. ratings should be reduced at the rate of 4% for each 1000 feet above sea level.
5. AFUE is rated in accordance with DOE test procedures.
6. Sound Rating is rated in accordance with ARI Standard 270 or 370.
7. Refrigerant charge is an approximate value. For a more precise value. see unit nameplate and service instructions.
8. Horizontal models have 8 - 20 x 25 x 2 fitters.
*Indicates both downflow and horizontal units.
14
0 TRAWE'" UH -DS -4
September 1994
Second Printing
Indoor Gas
Heating Products
Unit Heaters
and Duct
Furnaces
•
a �,� f � a
X33 ' t - , c.
---- 0, . . i i'l ..-7----------- . --- . — , , ( :
i
4
x _ z
i
it_
• ` , ,-
..':. i , . ,. , , ,
vid... M :4_:// If , 1
II' II, , ' k � •
..:,' A — '-- ,.4 li ji t 1 t ; , 11 . F . %:.: • ' skf
1 , { f i: ■r
''1E.) ) W.. „ ,
1 I sla I le p
•
. :'
i