Proiect
Triangle Point VAV Subs
t 3 cv T
City of Tigard
Ap •roved Plans I ?Jic'
By I Date 1
14/0 a) to -6n4-77
Approved plans
shall be on job site.
OFFICE COPY
7
•
Table Of Contents
Project: -Untitled10 09/29/2010
Prepared By: 11:05AM
S2 - 1 3
Unit Report 4
Certified Drawing 5
Performance Summary 6
Acoustic Summary 7
S2 - 2 8
Unit Report 9
Certified Drawing 10
Performance Summary 11
Acoustic Summary 12
S2 - 3 13
Unit Report 14
Certified Drawing 15
Performance Summary 16
Acoustic Summary 17
Air Terminals Builder 1.09e Page 2 of 17
S2 -1
Project: - Untitledl0 09/29/2010
Prepared By: 11:05AM
S2 -1
Tag Cover Sheet
Unit Report
Certified Drawing
Performance Report
Acoustic Summary
•
Air Terminals Builder 1.09e Page 3 of 17
•
Unit Report For S2 -1
Project: - Untitled10 09/29/2010
Prepared By: 11:05AM
V
s'
_--_.. _
Unit Parameters
Tag Name* S2 -1
Quantity: 1
Model Type VAV - CCN
Model 35E Single Duct Terminals
Control Type' 4141: CCN 1 -2 Stage Electric Heat
Unit and Inlet Size: 16 Inch
Part Number: 35EC1300L160414100000S000000E4211 .0K0000152007500750
Reheat Option: Electric Reheat
Insulation Lining: Standard (1/2 inch dual density f/g liner)
Outlet 24x18
Dimensions
Unit Depth: 39.5 in
Unit Width• 24.0 in
Unit Height 18.0 in
Unit Operating Weight • 66 lb
•" Weights and Dimensions are approximate. Weight does not include curbs
and accessories. Approximate dimensions are provided primarily for
shipping purposes. For exact dimensions, refer to certified drawings.
Warranty Information
1 Year Parts Only Warranty
Ordering Information
Part Number Description Quantity
Base Unit
35EC1300L1 60414100000S0 35E Single Duct Terminals 1
00000E4211.0K0000152007
500750
22 Gauge, Controls Left, No Access Panel
4141: CCN 1 -2 Stage Electric Heat
277v/1 Ph /2S
11.0 kW
Hangers
Door - Interlocking Fused Disconnect
Accessories
Air Terminals Builder 1.09e Page 4 of 17
Certified Drawing for S2 -1
Project: - Untitledl0 09/29/2010
Prepared By: 11:05AM
CODE Tw oocw¢.r „RR ,ROPE,,, a sua+$200P a TIM BASE UNIT WITH
0— Carrier TM, �er casnnne�a ANALOG OR DIGITAL
ne 35E
Cart NO
erte PAL T PP dYtOso PART PERrawrce
CATALOG A United TecnnalogiesCompany �.T�arrscoMS .rrs OP CONTR low A ND
ELECTRIC REHEAT
CHARTED 'A' DIMENSION INCLUDES INLET
6 1/4 ADAPTER PROVIDED ON SIZES 4 & 5.
W (159) �O 39 1/2 (1003) —1/2 (13)
AIR FLOW TYP SLIP & DRIVE OUTLET
SENSOR DUCT CONNECTION
I
HE 4`� INLET DISCHARGE
H N t2 5) TOP VIEW y TYP
. AIR I I LO
AIR
1 1 ll FLOW FLOW
DAMPER D 11
DIGITAL & REHEAT
INLET VIEW • SIZES 6-16 CONTROL ENCLOSURES
SIZE 22 (RECTANGULAR INLET)
(16"x 2e) ` — 36 5/8 (930) I B -
PROVIDE 36" MINIMUM ACCESS
PER NEC RF
I
SENSOR - Carriers standard linear multiple point air flow sensor is standard on all units with digital and pneumatic controls,
or for units with no controls.
LINER - The base unit is lined with standard 1/2" (13mm) thick, dual density insulation, with a body density of 1.5 Ibs/cu. Ft
(24 kg/m 3 ). This lining is coated to prevent erosion, and meets the requirements of UL 181 and NFPA 90A.. Optional: 1'
(25mm) thick insulation meeting same specifications as 1/2".. Optional: Steriliner insulation system, 13/16" thick rigid
insulation, foil laced on air stream -side, edges sealed from air stream with sheet metal z- strips.. Optional: Noliner insulation
system, with no internal insulation. External insulation is recommended to prevent condensation.
. Optional: Cellular insulation system, 3/8" thick thermal insulation consisting of closed-cell elastomeric insulation with a
smooth surface.
. Optional: Sterilwall insulation 1/2" think, blanket type, enclosed between zink - coated sheet metal.
. Optional: Perforated Double wall insulation - 23% perforated Sterilwall.
CASING - The base unit is constructed of 22 Ga galvanized steel. Seams are mechanically sealed to prevent
leakage k2% at maximum rated airflow at 6" (1.49kPa) Pal.. Optional: 20 Ga. galvanized steel casing.
DAMPER ASSEMBLIES - Leakage through the damper is less than 2% of nominal CFM at 6" (1.49Pa) Ps.
Size 4 through 16 - One heavy gage steel damper with polyethylene foam gasketing.
Size 22 - Two aluminum heavy gage opposed blades cross- linked with polyethylene foam gasketing.
ELECTRIC HEATER - . ETL Listed, adherence to UL 429 for electrically operated valves. Automatic reset thermal cutout,
Manual Reset thermal cutout and positive pressure air flow switch are standard. PE switches are standard step controllers
when pneumatic control systems are specified. Magnetic contactors are standard step controllers when electronic control
systems are specified. Control enclosure houses all control components. Available heater voltages:. 120v/1 e, . 208v/10,
. 240v118, . 277v110, . 208v/3o/3 -wire, . 480v/3e/4 -wire. Optional:. mercury contactors, . fuse block with fuses for primary
overload protection, . disconnect switches, . fused disconnect switches, . dust -tight construction.
UNIT ACCESSORIES - . Optional hanger brackets, . optional control sequences, see submittals.
35E WITH OPTIONAL ELECTRIC HEAT
INLET NOM MAX
_ SIZE CFM Ws) W H A B D C
4 230 (109) 12 (305) 8 (203) 5 3/8 (136) 5 15/16 (151) 3 7/8 (98) 2 (51)
5 360 (170) 12 (305) 8 (203) 5 3/8 (136) 5 15/16 (151) 4 7/8 (124) 2 (51)
6 515 (243) 12 (305) 8 (203) 3 3/8 (86) 5 15/16 (151) 5 7/8 (149) 2 (51)
7 700 (330) 12 (305) 10 (254) 3 3/8 (86) 5 15/16 (151) 6 7/8 (175) 1 (25)
NOTE: 8 920 (434) 12 (305) 10 (254) 3 3/8 (86) 5 15/16 (151) 7 7/8 (200) 1 (25)
1. Right hand configuration shown. 9 1160 (547) 14 (356) 12 1/2 (318) 3 3/8 (86) 3 15/16 (100) 8 7/8 (225) -
Leh hand is available.
2. Dimensions are given as inches (mm). 10 1430 (675) 14 (356) 12 1/2 (318) 3 3/8 (86) 3 15/16 (100) 9 7/8 (251)
3. See Drawing 35E for basic
unit Information. 12 2060 (972) 16 (406) 15 (381) 3 3/8 (86) 3 15/16 (100) 11 7/8 (302) -
4. See Drawing 35E - 202 - 11 for controls 14 2800 (1321) 20 (508) 17 1/2 (445) 3 3/8 (86) 1 15/16 (49) 13 7/8 (352) -
sped8cation data.
5. Size 22 control endosure 16 3660 (1727) 24 (610) 18 (457) 3 3/8 (86) 1 15/16 (49) 15 7/8 (403) -
32 5/8' (829mm) by 10 114' (260mm).
22 7000 (3304) 38 (965) 18 (457) 4 1/4 (108) - See Above 1 1/8 (29)
PRODUCT INFORMATION IS SUBJECT TO CHANGE WITHOUT NOTICE. 06/16/2003
jp,AAAAg J00 POMP LOG ORP.K1.4.
E101 W. B ,"P. 35E-202 -4
Air Terminals Builder 1.09e Page 5 of 17
Performance Summary For S2 -1
Project: - Untitled10 09/29/2010
Prepared By: 11:05AM
Unit Parameters
Tag Name S2 -1
Quantity: 1
Model Type* VAV - CCN
Model 35E Single Duct Terminals
Control Type* 4141: CCN 1 -2 Stage Electric Heat
Unit and Inlet Size: 16 Inch
Part Number: 35EC13001160414100000S000000E4211 .01(0000152007500750
Reheat Option: Electric Reheat
Outlet* 24x18
Unit Performance
Altitude: 0 ft
Max. Primary Airflow 1,520 0 CFM
Min. Primary Airflow 750 0 CFM
Inlet Static Pressure: 1.00 in wg
Downstream Static Pressure: .20 in wg
Minimum Static Pressure Drop: .04 in wg
Motor Voltage: 4141: CCN 1 -2 Stage Electric Heat
Note Inlet Static Pressure includes downstream pressure drop.
Electric Heating Coil Insulation:
Coil Airflow: 750.0 CFM Lining:...Standard (1/2 inch dual density f/g liner)
Capacity: 37.54 MBH Attenuator Yes
Entering Air Temp: 55.00 F
Leaving Air Temp: 101.35 F
Coil PD: 007 in wg
Error:... Query for txtReheatVoltage not resolved
kW: 11.0 kW
Steps: 2
MCA: 49.64
MOCP• N/A
Other Information: Acoustic Summary:
Maximum Airflow: 3,706.0 CFM Sound Power Levels, dB re 10E - 12 watts
Design Airflow: 1,520.0 CFM Primary Airflow: 1,520.0 CFM
Safety Factor: 59 %
Unit LxWxH: 39.5 x 24 x 18
Octave Bands (dB)
Radiated Sound 2 3 4 5 6 7 NC
Primary Sound (Pwl) 49 45 41 39 35 30
Total Attenuation 17 18 20 23 25 26 '
Room Sound Level (Sol) 32 27 21 16 10 < 10 14
Discharge Sound
Primary Sound (Pwl) 52 47 40 37 35 35
Total Attenuation 29 30 41 53 55 41
Room Sound Level (Spl) 23 17 < 10 < 10 < 10 < 10 1
Notes:
1. Room sound levels shown Include attenuation transfer functions shown above.
2. Data were obtained from tests conducted In accordance with ARI Standard 880 -90.
3. Sound power levels are In decibels, re 10 " -12 watts.
4. Dash ( -) In space Indicates sound and/or NC value is less than 10.
" Sound calculations are based on largest Inlet size.
The results of this program are only an aid to the designer, and are not a substitute for professional services.
Carrier Corporation accepts no liability for the adequacy of any resulting design or installation.
All data subject to change without notice.
Air Terminals Builder 1.09e Page 6 of 17
Acoustics Summary For S2 -1
Project: - Untitledl0 09/29/2010
Prepared By: 11:05AM
Unit Parameters
Tag Name S2 -1
Quantity: 1
Model Type VAV - CCN
Model 35E Single Duct Terminals
Control Type 4141: CCN 1 -2 Stage Electric Heat
Unit and Inlet Size: 16 Inch
Part Number: 35EC1300L160414100000S000000E4211 .0K0000152007500750
Reheat Option: Electric Reheat
Outlet 24x18
Insulation: Other Information:
Lining:...Standard (1/2 inch dual density Vg liner) Maximum Airflow: 3,706.0 CFM
Attenuator Yes Design Airflow: 1,520.0 CFM
Safety Factor: 59 %
Unit LxWxH: 39.5 x 24 x 18
Acoustic Summary:
Sound Power Levels, dB re 10E - 12 watts
Primary Airflow 1,520.0 CFM
Octave Bands (dB)
Radiated Sound 2 3 4 5 6 7 NC
Primary Sound (Pwl) 49 45 41 39 35 30
Total Attenuation 17 18 20 23 25 26
Room Sound Level (Spl) 32 27 21 16 10 < 10 14
Discharge Sound
Primary Sound (Pwl) 52 47 40 37 35 35 '
Total Attenuation 29 30 41 53 55 41
Room Sound Level (Spl) 23 17 < 10 < 10 < 10 < 10 1
Notes:
1. Room sound levels shown include attenuation transfer functions shown above.
2. Data were obtained from tests conducted In accordance with ARI Standard 880 -90.
3. Sound power levels are In decibels, re 10A -12 watts.
4. Dash ( -) In space indicates sound and /or NC value Is less than 10.
-. Sound calculations are based on largest Inlet slze.
The results of this program are only an aid to the designer, and are not a substitute for professional services.
Carrier Corporation accepts no liability for the adequacy of any resulting design or installation.
All data subject to change without notice.
Air Terminals Builder 1.09e Page 7 of 17
S2 -2
Project: - Untitled10 09/29/2010
Prepared By: 11:05AM
S2-2
Tag Cover Sheet
Unit Report
Certified Drawing
Performance Report
Acoustic Summary
Air Terminals Builder 1.09e Page 8 of 17
Unit Report For S2 -2
Project: -Untitledl0 09/29/2010
Prepared By: 11:05AM
.
a i t
Unit Parameters
Tag Name S2 -2
Quantity: 1
Model Type VAV - CCN
Model 35E Single Duct Terminals
Control Type 4141: CCN 1 -2 Stage Electric Heat
Unit and Inlet Size: 16 Inch
Part Number: 35EC1300L160414100000S000000E4213 .0K0000194007500750
Reheat Option: Electric Reheat
Insulation Lining: Standard (1/2 inch dual density f/g liner)
Outlet 24x18
Dimensions
Unit Depth: 39.5 in
Unit Width• 24.0 in
Unit Height 18.0 in
Unit Operating Weight : 66 lb
*" Weights and Dimensions are approximate. Weight does not include curbs
and accessories. Approximate dimensions are provided primarily for
shipping purposes. For exact dimensions, refer to certified drawings.
Warranty Information
1 Year Parts Only Warranty
Ordering Information
Part Number Description Quantity
Base Unit
35EC1300L160414100000S0 35E Single Duct Terminals 1
00000E4213.0K0000194007
500750
22 Gauge, Controls Left, No Access Panel
4141: CCN 1 -2 Stage Electric Heat
277v/1 Ph /2S
13.0 kW
Hangers
Door - Interlocking Fused Disconnect
Accessories
Air Terminals Builder 1.09e Page 9 of 17
Certified Drawing for S2 -2
Project: -Untit]ed10 09/29/2010
Prepared By: 11:05AM
CODE n.s ocaAe u v
.r t. PROPERTY 910.90. OF ,wEM BASE UNIT WITH
0- Carrier : c c . = ANALOG OR DIGITAL
THE 35E
CATALOGA WNr6Yf 8WLLWi tlOSCLOS® '"'r C 'm CONTR OLS A ND
A United Technologies Company �w.no. cansEm A.e on
ELECTRIC REHEAT
CHARTED 'A' DIMENSION INCLUDES INLET
ADAPTER PROVIDED ON SIZES 4 & 5.
W (159) - 39 1/2 (1003) —1/2 (13)
AIR FLOW TYP SLIP & DRIVE OUTLET
SENSOR DUCT CONNECTION
INLET DISCHARGE
H 1 2 (305) ♦
TYP TOP VIEW - ►
AIR
AIR - 4 1 '
i t FLOW FLOW
DAMPER D II I 1 ~
DIGITAL & REHEAT
INLET VIEW - SIZES 6-16 CONTROL ENCLOSURES
SIZE 22 (RECTANGULAR INLET) I
(16"x 241 F--- 36 5/8 (930) I L 13
PROVIDE 36" MINIMUM ACCESS
PER NEC R9UIREMENT
I
SENSOR - Carrier's standard linear multiple point air flow sensor is standard on all units with digital and pneumatic controls,
or for units with no controls.
LINER - The base unit is lined with standard 1/2" (13mm) thick, dual density insulation, with a body density of 1.5 Ibs/cu. Ft
(24 kg/m '). This lining is coated to prevent erosion, and meets the requirements of UL 181 and NFPA 90A.. Optional: 1"
(25mm) thick insulation meeting same specifications as 1/2".. Optional: Steriliner insulation system, 13/16" thick rigid
insulation, foil faced on air stream -side, edges sealed from air stream with sheet metal z- strips.. Optional: Noliner insulation .
system, with no internal insulation. External insulation is recommended to prevent condensation.
. Optional: Cellular insulation system, 3/8" thick thermal insulation consisting of dosed -cell elastomeric insulation with a
smooth surface.
. Optional: Sterilwall insulation 1/2" think, blanket type, enclosed between zink- coated sheet metal.
. Optional: Perforated Double wall insulation - 23% perforated Sterilwall.
CASING - The base unit is constructed of 22 Ga. galvanized steel. Seams are mechanically sealed to prevent
leakage [ <2% at maximum rated airflow at 6" (1.49kPa) Ps.].. Optional: 20 Ga. galvanized steel casing.
DAMPER ASSEMBUES - Leakage through the damper is less than 2% of nominal CFM at 6" (1.49Pa) Ps.
Size 4 through 16 - One heavy gage steel damper with polyethylene foam gasketing.
Size 22 - Two aluminum heavy gage opposed blades cross- linked with polyethylene foam gasketing.
ELECTRIC HEATER - . ETL Listed, adherence to UL 429 for electrically operated valves. Automatic reset thermal cutout,
Manual Reset thermal cutout and positive pressure air flow switch are standard. PE switches are standard step controllers
when pneumatic control systems are specified. Magnetic contactors are standard step controllers when electronic control
systems are specified. Control enclosure houses all control components. Available heater voltages:. 120v/1 e, . 208v/1 e,
. 240v/1 e, . 277v/10, . 208v/3e/3 -wire, . 480v/3e/4 -wire. Optional:. mercury contactors, . fuse block with fuses for primary
overload protection, . disconnect switches, . fused disconnect switches, . dust -tight construction.
UNIT ACCESSORIES - . Optional hanger brackets, . optional control sequences, see submittals.
35E WITH OPTIONAL ELECTRIC HEAT
INLET NOM MAX
SIZE CFM (Lis) W H A B D C
4 230 (109) 12 (305) 8 (203) 5 3/8 (136) 5 15/16 (151) 3 7/8 (98) 2 (51)
5 360 (170) 12 (305) 8 (203) 5 3/8 (136) 5 15/16 (151) 4 7/8 (124) 2 (51)
6 515 (243) 12 (305) 8 (203) 3 3/8 (86) 5 15/16 (151) 5 7/8 (149) 2 (51)
7 700 (330) 12 (305) 10 (254) 3 3/8 (86) 5 15/16 (151) 6 7/8 (175) 1 (25)
NOTE: 8 920 (434) 12 (305) 10 (254) 3 3/8 (86) 5 15/16 (151) 7 7/8 (200) 1 (25)
t. Right hand configuration shown. 9 1160 (547) 14 (356) 12 1/2 (318) 3 3/8 (86) 3 15/16 (100) 8 7/8 (225)
' Lett hand is available.
2. Dimensions are given as Inches (mm). 10 1430 (675) 14 (356) 12 1/2 (318) 3 3/8 (86) 3 15/16 (100) 9 7/8 (251)
3. See Drawing 35E -202 -1 C for basic
unit information. 12 2060 (972) 16 (406) 15 (381) 3 3/8 (86) 3 15/16 (100) 11 7/8 (302) -
4. See Drawing 35E - 202.11 for controls 14 2800 (1321) 20 (508) 17 1/2 (445) 3 3/8 (86) 1 15/16 (49) 13 7/8 (352) -
speci0cadon data.
5. Size 22 control endosure 16 3660 (1727) 24 (610) 18 (457) 3 3/8 (86) 1 15/16 (49) 15 7/8 (403) -
32 5/8" (829mm) by 10 1/4" (260mm).
22 7000 (3304) 38 (965) 18 (457) 4 1/4 (108) - See Above 1 1/8 (29)
PRODUCT INFORMATION IS SUBJECT TO CHANGE WITHOUT NOTICE. 06/16/2003
01.11 01P.S. ,nc ro. 0s.w01(.0.
.,,.ra .M„ ae so B SHEET 35E -202 -4
Air Terminals Builder 1.09e Page 10 of 17
Performance Summary For S2 -2
Project: - Untitledl0 09/29/2010
Prepared By: 11:05AM
Unit Parameters
Tag Name S2 -2
Quantity: 1
Model Type* VAV - CCN
Model 35E Single Duct Terminals
Control Type* 4141: CCN 1 -2 Stage Electric Heat
Unit and Inlet Size: 16 Inch
Part Number: 35EC1300L160414100000S000000E4213 .0K0000194007500750
Reheat Option: Electric Reheat
Outlet 24x18
Unit Performance
Altitude: 0 ft
Max. Primary Airflow* 1,940.0 CFM
Min. Primary Airflow* 750.0 CFM
Inlet Static Pressure: 1.00 in wg
Downstream Static Pressure: 20 in wg
Minimum Static Pressure Drop* 06 in wg
Motor Voltage: 4141: CCN 1 -2 Stage Electric Heat
Note* Inlet Static Pressure includes downstream pressure drop.
Electric Heating Coil Insulation:
Coil Airflow: 750.0 CFM Lining:...Standard (1/2 inch dual density f/g liner)
Capacity: 44.37 MBH Attenuator• Yes
Entering Air Temp: 55.00 F
Leaving Air Temp: 109.78 F
Coil PD: 007 in wg
Error: ... Query for txtReheatVoltage not resolved
kW: 13.0 kW
Steps: 2
MCA: 58.66
MOCP• N/A
Other Information: Acoustic Summary:
Maximum Airflow: 3,706.0 CFM Sound Power Levels, dB re 10E - 12 watts
Design Airflow: 1,940.0 CFM Primary Airflow* 1,940.0 CFM
Safety Factor: 48
Unit LxWxH: 39.5 x 24 x 18
Octave Bands (dB)
Radiated Sound 2 3 4 5 6 7 NC
Primary Sound (Pwl) 52 48 44 41 38 32 •
Total Attenuation 17 18 20 23 25 26
Room Sound Level (Spl) 35 30 24 18 13 < 10 18
Discharge Sound
Primary Sound (Pwl) 57 52 46 41 39 39 *
Total Attenuation 29 30 41 53 55 41 •
Room Sound Level (Spl) 28 22 < 10 < 10 < 10 < 10 7
Notes:
1. Room sound levels shown Include attenuation transfer functions shown above.
2. Data were obtained from tests conducted in accordance with ARI Standard 880 -90.
3. Sound power levels are In decibels, re 10A -12 watts.
4. Dash ( -) in space Indicates sound and/or NC value Is less than 10.
" Sound calculations are based on largest Inlet size.
The results of this program are only an aid to the designer, and are not a substitute for professional services.
Carrier Corporation accepts no liability for the adequacy of any resulting design or installation.
All data subject to change without notice.
Air Terminals Builder 1.09e Page 11 of 17
Acoustics Summary For S2 -2
Project: - Untitledl0 09/29/2010
Prepared By: 11:05AM
Unit Parameters
Tag Name S2 -2
Quantity: 1
Model Type* VAV - CCN
Model 35E Single Duct Terminals
Control Type 4141: CCN 1 -2 Stage Electric Heat
Unit and Inlet Size: 16 Inch
Part Number: 35EC1300L160414100000S000000E4213 .0K0000194007500750
Reheat Option: Electric Reheat
Outlet 24x18
Insulation: Other Information:
Lining:...Standard (1/2 inch dual density f/g liner) Maximum Airflow: 3,706.0 CFM
Attenuator Yes Design Airflow: 1,940.0 CFM
Safety Factor: 48 %
Unit LxWxH• 39.5 x 24 x 18
Acoustic Summary:
Sound Power Levels, dB re 10E - 12 watts
Primary Airflow 1,940.0 CFM
Octave Bands (dB)
Radiated Sound 2 3 4 5 6 7 NC
Primary Sound (Pwl) 52 48 44 41 38 32
Total Attenuation 17 18 20 23 25 26
Room Sound Level (SpI) 35 30 24 18 13 < 10 18
Discharge Sound
Primary Sound (Pwl) 57 52 46 41 39 39 *
Total Attenuation 29 30 41 53 55 41
Room Sound Level (Spl) 28 22 < 10 < 10 < 10 < 10 7
Notes:
1. Room sound levels shown Include attenuation transfer functions shown above.
2. Data were obtained from tests conducted in accordance with ARI Standard 880.90.
3. Sound power levels are in decibels, re 10A -12 watts.
4. Dash ( -) In space indicates sound and /or NC value Is less than 10.
" Sound calculations are based on largest inlet size.
The results of this program are only an aid to the designer, and are not a substitute for professional services.
Carrier Corporation accepts no liability for the adequacy of any resulting design or installation.
All data subject to change without notice.
Air Terminals Builder 1.09e Page 12 of 17
S2 -3
Project: - Untitledl0 09/29/2010
Prepared By: 11:05AM
S2 -3
Tag Cover Sheet
Unit Report
Certified Drawing
Performance Report
Acoustic Summary
Air Terminals Builder 1.09e Page 13 of 17
Unit Report For S2 -3
Project: -Untitledl0 09/29/2010
Prepared By: 11:05AM
r,
Unit Parameters
Tag Name S2 -3
Quantity: 1
Model Type VAV - CCN
Model 35E Single Duct Terminals
Control Type 4141: CCN 1 -2 Stage Electric Heat
Unit and Inlet Size: 16 Inch
Part Number: 35EC1300L1 6041 41 00000S000000E4212 .0K0000164007500750
Reheat Option: Electric Reheat
Insulation Lining: Standard (1/2 inch dual densityf /g liner)
Outlet' 24x18
Dimensions
Unit Depth: 39.5 in
Unit Width' 24.0 in
Unit Height' 18.0 in
Unit Operating Weight : 66 lb
*" Weights and Dimensions are approximate. Weight does not include curbs
and accessories. Approximate dimensions are provided primarily for
shipping purposes. For exact dimensions, refer to certified drawings.
Warranty Information
1 Year Parts Only Warranty
Ordering Information
Part Number Description Quantity
Base Unit
35EC1300L160414100000S0 35E Single Duct Terminals 1
00000E4212.0K0000164007
500750
22 Gauge, Controls Left, No Access Panel
4141: CCN 1 -2 Stage Electric Heat
277v/1 Ph /2S
12.0 kW
Hangers
Door - Interlocking Fused Disconnect
Accessories
Air Terminals Builder 1.09e Page 14 of 17
Certified Drawing for S2 -3
Project: - Untitledl0 09/29/2010
Prepared By: 11:05AM
CODE ,„ „Q„ uNE P CO roe „ OP rreg BASE UNIT WITH
0 Carrier `� m 'no "np« me°A", �.o" ° reB 1 ANALOG OR DIGITAL 35E
THE mnerra wueor ee sec.= Port www
owce
CATALOG a A United Teennologles Company OR USED r, meat r.ce OP Wallin OLS AN D
ELECTRIC REHEAT
CHARTED 'A' DIMENSON INCLUDES INLET
6 1/4 ADAPTER PROVIDED ON SIZES 4 & 5.
W (159) - 39 1/2 (1003) —1/2 (13)
AIR FLOW TYP SUP & DRIVE OUTLET
SENSOR DUCT CONNECTION
INLET DISCHARGE
H 12 (305) TOP VIEW 4•11.
AIR V I I AIR
I 1 FLOW FLOW
DAMPER p - 11
DIGITAL & REHEAT
INLET VIEW- SIZES 6.16 CONTROL ENCLOSURES
SIZE 22 (RECTANGULAR INLET) I
(16 Y 24 ") 1-- 36 5/8 (930) 16 -
I L
PROVIDE 36" MINIMUM ACCESS
PER NEC RF
I
SENSOR - Carrier's standard linear multiple point air flow sensor is standard on all units with digital and pneumatic controls,
or for units with no controls.
LINER - The base unit is lined with standard 1/2" (13mm) thick, dual density insulation, with a body density of 1.5 Ibs/cu. Ft
(24 kg/m 3 ). This lining is coated to prevent erosion, and meets the requirements of UL 181 and NFPA 90A.. Optional: 1"
(25mm) thick insulation meeting same specifications as 1/2". . Optional: Steriliner insulation system, 13/16" thick rigid
insulation, foil faced on air stream -side, edges sealed from air stream with sheet metal z- strips.. Optional: Noliner insulation
system, with no internal insulation. External insulation is recommended to prevent condensation.
. Optional: Cellular insulation system, 3/8" thick thermal insulation consisting of closed -cell elastomeric insulation with a
smooth surface.
. Optional: Sterilwall insulation 1/2" think, blanket type, enclosed between zink - coated sheet metal.
. Optional: Perforated Double wall insulation - 23% perforated Sterilwall.
CASING - The base unit is constructed of 22 Ga. galvanized steel. Seams are mechanically sealed to prevent
leakage (<2% at maximum rated airflow at 6" (1.49kPa) Ps.).. Optional: 20 Ga. galvanized steel casing.
DAMPER ASSEMBLIES - Leakage through the damper is less than 2% of nominal CFM at 6" (1.49Pa) Ps.
Size 4 through 16 - One heavy gage steel damper with polyethylene foam gasketing.
Size 22 - Two aluminum heavy gage opposed blades cross - linked with polyethylene foam gasketing.
ELECTRIC HEATER - . ETL Listed, adherence to UL 429 for electrically operated valves. Automatic reset thermal cutout,
Manual Reset thermal cutout and positive pressure air flow switch are standard. PE switches are standard step controllers
when pneumatic control systems are specified. Magnetic contactors are standard step controllers when electronic control
systems are specified. Control enclosure houses all control components. Available heater voltages:. 120v /1e, . 208v /1e,
. 240v/10, . 277v/1 e, . 208v/3o/3 -wire, . 480v/3o/4 -wire. Optional: . mercury contactors, . fuse block with fuses for primary
overload protection, . disconnect switches, . fused disconnect switches, . dust -tight construction.
UNIT ACCESSORIES - . Optional hanger brackets, . optional control sequences, see submittals.
35E WITH OPTIONAL ELECTRIC HEAT
INLET NOM MAX
SIZE CFM (L/s) W H A B D C
4 230 (109) 12 (305) 8 (203) 5 3/8 (136) 5 15/16 (151) 3 7/8 (98) 2 (51)
5 360 (170) 12 (305) 8 (203) 5 3/8 (136) 5 15/16 (151) 4 7/8 (124) 2 (51)
6 515 (243) 12 (305) 8 (203) 3 3/8 (86) 5 15/16 (151) 5 7/8 (149) 2 (51)
7 700 (330) 12 (305) 10 (254) 3 3/8 (86) 5 15/16 (151) 6 7/8 (175) 1 (25)
NOTE: 8 920 (434) 12 (305) 10 (254) 3 3/8 (86) 5 15/16 (151) 7 7/8 (200) 1 (25)
1. Right nand configuration shown. 9 1160 (547) 14 (356) 12 1/2 (318) 3 3/8 (86) 3 15/16 (100) 8 7/8 (225) -
Left hand is available.
2. Dimensions are given as inches (mm). 10 1430 (675) 14 (356) 12 1/2 (318) 3 3/8 (86) 3 15/16 (100) 9 7/8 (251) •
3. See Drawing 35E-202-1C for basic
unitlnrormatlon. 12 2060 (972) 16 (406) 15 (381) 3 3/8 (86) 3 15/16 (100) 11 7/8 (302) -
4. See Drawing 35E - 202.11 for controls 14 2800 (1321) 20 (508) 17 1/2 (445) 3 3/8 (86) 1 15/16 (49) 13 7/8 (352) -
speci8ca0on data.
5. Size 22 control enclosure 16 3660 (1727) 24 (610) 18 (457) 3 3/8 (86) 1 15/16 (49) 15 7/8 (403) -
32 5/8' (829mm) by 10 1/4' (260mm). 22 7000 (3304) 38 (965) 18 (457) 4 1/4 (108) - See Above 1 1/8 (29)
PRODUCT INFORMATION IS SUBJECT TO CHANGE WITHOUT NOTICE. 06/16/2003
sswwe neru.eeA room oe•we.Mre"
arven. se�oo s Ee 35E-202 -4
B
Air Terminals Builder 1.09e Page 15 of 17
Performance Summary For S2 -3
Project: -Untitled10 09/29/2010
Prepared By: 11:05AM
Unit Parameters
Tag Name* S2 -3
Quantity: 1
Model Type VAV - CCN
Model 35E Single Duct Terminals
Control Type 4141: CCN 1 -2 Stage Electric Heat
Unit and Inlet Size: 16 Inch
Part Number: 35EC1300L1 6041 41 00000S000000E4212 .0K0000164007500750
Reheat Option: Electric Reheat
Outlet 24x18
Unit Performance
Altitude: 0 ft
Max. Primary Airflow 1,640 0 CFM
Min. Primary Airflow 750 0 CFM
Inlet Static Pressure: 1.00 in wg
Downstream Static Pressure: .20 in wg
Minimum Static Pressure Drop* .04 in wg
Motor Voltage: 4141: CCN 1 -2 Stage Electric Heat
Note Inlet Static Pressure includes downstream pressure drop.
Electric Heating Coil Insulation:
Coil Airflow: 750.0 CFM Lining:...Standard (1/2 inch dual density f/g liner)
Capacity: 40.96 MBH Attenuator• Yes
Entering Air Temp: 55.00 F
Leaving Air Temp: 105.56 F
Coil PD: 007 in wg
Voltage: 277 -1 -60
kW: 12.0 kW
Steps: 2
MCA: 54.15
MOCP• N/A
Other Information: Acoustic Summary: •
Maximum Airflow: 3,706.0 CFM Sound Power Levels, dB re 10E - 12 watts
Design Airflow: 1,640.0 CFM Primary Airflow* 1,640.0 CFM
Safety Factor: 56 %
Unit LxWxH: 39.5 x 24 x 18
Octave Bands (dB)
Radiated Sound 2 3 4 5 6 7 NC
Primary Sound (Pwl) 50 46 42 40 36 30 *
Total Attenuation 17 18 20 23 25 26 `
Room Sound Level (Spl) 33 28 22 17 11 < 10 15
Discharge Sound
Primary Sound (Pwl) 54 48 42 38 37 36 *
Total Attenuation 29 30 41 53 55 41 *
Room Sound Level (Spl) 25 . 18 < 10 < 10 < 10 < 10 2
Notes:
1. Room sound levels shown include attenuation transfer functions shown above.
2. Data were obtained from tests conducted in accordance with ARI Standard 880 -90.
3. Sound power levels are In decibels, re 10 ^ -12 watts.
4. Dash ( -) in space Indicates sound and /or NC value Is Tess than 10.
Sound calculations are based on largest Inlet size.
The results of this program are only an aid to the designer, and are not a substitute for professional services.
Carrier Corporation accepts no liability for the adequacy of any resulting design or installation.
All data subject to change without notice.
Air Terminals Builder 1.09e Page 16 of 17
Acoustics Summary For S2 -3
Project: - Untitledl0 09/29/2010
Prepared By: 11:05AM
Unit Parameters
Tag Name S2 -3
Quantity: 1
Model Type VAV - CCN
Model 35E Single Duct Terminals
Control Type: 4141: CCN 1 -2 Stage Electric Heat
Unit and Inlet Size: 16 Inch
Part Number: 35EC1300L160414100000S000000E4212 .0K0000164007500750
Reheat Option: Electric Reheat
Outlet* 24x18
Insulation: Other Information:
Lining:...Standard (1/2 inch dual density f/g liner) Maximum Airflow: 3,706.0 CFM
Attenuator• Yes Design Airflow: 1,640.0 CFM
Safety Factor: 56 %
Unit LxWxH: 39.5 x 24 x 18
Acoustic Summary:
Sound Power Levels, dB re 10E -12 watts
Primary Airflow: 1,640.0 CFM
Octave Bands (dB)
Radiated Sound 2 3 4 5 6 7 NC
Primary Sound (Pwl) 50 46 42 40 36 30
Total Attenuation 17 18 20 23 25 26
Room Sound Level (Spl) 33 28 22 17 11 < 10 15
Discharge Sound
Primary Sound (Pwi) 54 48 42 38 37 36
Total Attenuation 29 30 41 53 55 41
Room Sound Level (Spl) 25 18 < 10 < 10 < 10 < 10 2
Notes:
1. Room sound levels shown Include attenuation transfer functions shown above.
2. Data were obtained from tests conducted In accordance with ARI Standard 880 -90.
3. Sound power levels are In decibels, re 10 ^ -12 watts.
4. Dash ( -) in space indicates sound and /or NC value is less than 10.
•' Sound calculations are based on largest Inlet size.
The results of this program are only an aid to the designer, and are not a substitute for professional services.
Carrier Corporation accepts no liability for the adequacy of any resulting design or installation.
All data subject to change without notice.
Air Terminals Builder 1.09e Page 17 of 17